Description
Triad Magnetics F-279U (also known as F279U) is an industrial-grade step-down power and control transformer from Triad’s proven F-Series, where the “U” suffix denotes an open-frame steel bracket chassis-mount construction equipped with flexible flying wire leads. Engineered for high-reliability AC step-down conversion and galvanic line isolation, this unit accepts a nominal 115 VAC 50/60 Hz primary input and delivers a center-tapped 60.0 VCT secondary output at 1.00 A (configurable as 60 VAC end-to-end or dual 30 VAC-0-30 VAC split-phase outputs) with a continuous apparent power rating of 60.0 VA. Wound on a rugged single-channel nylon bobbin, the transformer achieves a typical 10% voltage regulation from full load to no load and maintains a low 35 °C typical temperature rise (45 °C maximum allowed) at a 25 °C ambient baseline.
Mechanically, the F-279U features a compact four-slot steel mounting bracket measuring 63.5 mm (2.50 in) in width, 76.2 mm (3.00 in) in height, and 66.7 mm (2.625 in) in depth, with a solid 1.54 kg (3.40 lbs) core mass and 50.8 × 60.3 mm (2.00 × 2.375 in) mounting slot centers. Pre-stripped and tinned 178 mm (7.0 in) 22 AWG UL 1015 stranded leads simplify cabinet wiring, utilizing Black-to-Black leads for the 115 VAC primary and Green-to-Green leads with a Green/Yellow center tap for the 60 VCT secondary. Every unit is constructed with UL-recognized Class B (130 °C / 266 °F) insulation materials, 100% factory hipot tested to 1500 VAC between primary-to-secondary and windings-to-core, and fully compliant with RoHS 3 (2015/863/EU) directives.
Key Features
- 60.0 VA Center-Tapped Secondary Output: Delivers a continuous 60.0 VCT output rated at 1.00 A full-load current, supporting either 60 VAC single-output or 30V-0-30V split-phase full-wave rectifier and control topologies.
- Standard 115 VAC 50/60 Hz Primary Operation: Optimized for North American and industrial 115 VAC single-phase control buses across 50 Hz and 60 Hz line frequencies with tight 10% typical full-load to no-load regulation.
- 100% 1500 VAC Dielectric Hipot Testing: Every transformer undergoes factory production hipot testing at 1500 VAC between primary and secondary windings as well as between windings and the laminated steel core.
- UL Class B (130 °C) Insulation System: Precision-wound on a single-channel nylon bobbin using UL-recognized Class B thermal materials, maintaining a conservative 35 °C typical temperature rise (45 °C maximum allowed).
- Color-Coded 22 AWG UL 1015 Flying Leads: Supplied with 178 mm (7.0 in) stranded 22 AWG UL 1015 wire leads pre-stripped and tinned to 6.0 mm (0.25 in) for rapid terminal block or solder integration.
- Heavy-Duty 4-Slot Chassis Bracket: Rugged stamped steel mounting frame incorporates four 5.16 × 9.53 mm (0.203 × 0.375 in) mounting slots on 50.8 × 60.3 mm (2.00 × 2.375 in) centers for vibration-resistant sub-panel installation.
Technical Specifications
| Manufacturer | Triad Magnetics |
|---|---|
| Manufacturer Part Number (MPN) | F-279U |
| Alternate Part Number | F279U |
| Product Series | F-Series (Open-Frame Chassis Mount Power Transformers) |
| Product Category | Control Transformers |
| Component Type | Single-Secondary Center-Tapped Step-Down Power & Control Transformer |
| Circuit Topology | Galvanically Isolated Laminated Core Transformer (Single-Channel Nylon Bobbin) |
| Rated Power / Capacity (VA) | 60.0 VA |
| Secondary Output Voltage | 60.0 VCT (30 VAC – 0 – 30 VAC Center-Tapped) |
| Rated Output Current | 1.00 A (at 60.0 VCT Full Load) |
| Number of Outputs | 1 Secondary Winding with Center Tap (3 Secondary Leads) |
| Load Regulation | 10% Typical (Full Load to No Load) |
| Rated Operating Voltage | 115 VAC (Single-Phase Primary) |
| Operating Frequency Range | 50 / 60 Hz |
| Mounting Style | Chassis Mount (4-Slot Steel Foot Bracket) |
| Cooling Method | Free Air Convection |
| Package / Footprint Standard | U-Style Open-Frame Laminated Core with Flying Leads |
| Overall Width (W) | 63.5 mm (2.50 in) [Dimension B] |
| Overall Height (H) | 76.2 mm (3.00 in) [Dimension A] |
| Overall Depth (D) | 66.7 mm (2.625 in) [Dimension C] |
| Mounting Hole Pitch | 50.8 × 60.3 mm (2.00 × 2.375 in) [Dimensions D × E]; 4 Slots: 5.16 × 9.53 mm (0.203 × 0.375 in) |
| Net Weight | 1.54 kg (3.40 lbs / 54.4 oz) |
| Termination / Connector Style | Stranded Flying Wire Leads (UL 1015, Stripped and Tinned 6.0 mm / 0.25 in) |
| Input Terminal Pinout | Primary (115 VAC, 50/60 Hz): Black Lead to Black Lead |
| Output & Signal Terminal Pinout | Secondary (60.0 VCT @ 1.00 A): Green Lead to Green Lead; Center Tap: Green/Yellow Lead |
| Lead Wire Length | 178 mm (7.0 in) |
| Terminal Wire Gauge Range | 22 AWG Stranded (UL 1015 Rated) |
| Enclosure / Potting Material | Single-Channel Nylon Bobbin with Laminated Silicon Steel Core and Steel Mounting Bracket |
| Withstand Isolation Voltage (I/P to O/P) | 1500 VAC (100% Factory Hipot Tested) |
| Withstand Isolation Voltage (I/P to FG / Case) | 1500 VAC (Primary Winding to Core) |
| Withstand Isolation Voltage (O/P to FG / Case) | 1500 VAC (Secondary Winding to Core) |
| Operating Ambient Temperature Range | Rated at 25 °C (77 °F) Ambient; Class B Insulation System Rated to 130 °C (266 °F) Max. Winding Temperature |
| Full-Load Operating Temperature Limit | 35 °C (63 °F) Typical Temperature Rise; 45 °C (81 °F) Maximum Allowed Rise |
| Safety Approvals (UL / North America) | Constructed with UL-Recognized Class B (130 °C) Materials and UL 1015 Lead Wires |
| Environmental Compliance | RoHS 3 Compliant (Directive 2015/863/EU) |
Industrial Applications & Compatible Systems
The Triad Magnetics F-279U is widely deployed across industrial control cabinets, linear power stages, and factory automation equipment requiring dependable 115 VAC to 60 VCT step-down isolation:
- Linear Dual-Rail & Single-Rail DC Power Supplies: Ideal front-end step-down transformer for full-wave center-tapped rectifiers (producing ±42 VDC unregulated rails) or full-wave bridge rectifiers in test benches and analog instrumentation.
- Industrial Control Panels & Relay Logic: Supplies isolated 60 VAC or dual 30 VAC control power for machine tool contactors, solenoid actuators, HVAC damper controls, and legacy relay automation panels.
- Audio, Broadcast & Telecom Amplifiers: Provides low-noise 50/60 Hz galvanic isolation and bipolar power supply feeding for professional audio preamplifiers, intercom trunks, and telecom ring/bias circuits.
- OEM Machinery & Legacy MRO Retrofits: Direct drop-in mechanical and electrical replacement for aging 60 VA 60 VCT chassis-mount transformers in packaging machinery, elevators, and laboratory equipment.
Installation, Thermal Management & MRO Guidelines
Follow these engineering best practices when integrating the F-279U into enclosure layouts:
- Primary & Secondary Overcurrent Protection: Install an appropriately sized time-delay primary fuse (typically 0.75 A to 1.0 A slow-blow at 115 VAC) and a 1.0 A secondary fuse to protect the single-channel nylon bobbin against downstream short circuits and magnetizing inrush currents.
- Center-Tap & Split-Phase Wiring Configuration: Connect across the two Green leads for full 60.0 VAC @ 1.00 A operation while insulating the unused Green/Yellow center tap, or reference the Green/Yellow lead to circuit ground for symmetrical 30 VAC-0-30 VAC split-phase operation.
- Chassis Grounding & Thermal Clearance: Bolt all four 0.203 × 0.375 in mounting slots securely to a grounded metal sub-panel using M5 or #10 hardware, and maintain adequate airflow around the open core so total ambient plus 35 °C–45 °C temperature rise remains well below the 130 °C Class B insulation limit.