DRB240-24-3-A0 TDK-Lambda 240W 24VDC Three-Phase PSU

$215.28

TDK-Lambda DRB240-24-3-A0 (DRB240243A0) 240W 24VDC 10A 3-phase DIN rail power supply, 380-500VAC input, 93.2% efficiency, 360W peak boost, UL/IEC 61010-1.

SKU: DRB240-24-3-A0 Category: Brand:

Description

TDK-Lambda DRB240-24-3-A0 (also known as DRB240243A0) is an industrial three-phase DIN rail AC-DC power supply from the DRB120-3 to DRB960-3 series, where the -3 denotes three-phase operation and the -A0 suffix specifies screw-clamp terminal blocks with standard uncoated PCBs. Accepting a wide nominal input of 380 to 500 VAC three-phase (342 to 575 VAC maximum continuous range) as well as 450 to 810 VDC, it delivers a tightly regulated 24 VDC output (adjustable from 22.5 to 29 VDC) at 10 A continuous (240 W) and up to 15 A (360 W, 150% boost) for 60 seconds to start heavy capacitive or inductive loads. Operating with a variable 50 to 135 kHz switching topology, it achieves 93.1% / 93.2% efficiency at 400 / 500 VAC, 0.05% line regulation, 0.2% single-unit load regulation, and 40 mV ripple and noise at room-to-elevated ambient temperatures.

Engineered for harsh automation cabinets, the unit incorporates >142% constant-current and hiccup overcurrent protection, auto-recovery overvoltage protection below 32.7 V, auto-recovery overtemperature protection, a DC Good relay contact, remote on/off inhibit input, and a front-panel DIP switch for parallel droop-mode current sharing. Reinforced three-zone galvanic isolation provides 6,400 VAC input-to-output, 2,210 VAC input-to-ground, and 1,390 VAC output-to-ground withstand ratings. Housed in a slim 55 × 129 × 138.2 mm (2.17 × 5.08 × 5.44 in) convection-cooled aluminum enclosure for TS-35/7.5 or TS-35/15 DIN rails, it operates at full load from -25 °C to +55 °C (-40 °C cold start-up) with linear derating up to +70 °C and holds IEC/EN/UL/CSA 61010-1, 61010-2-201, and 62368-1 approvals.

Key Features

  • Wide Three-Phase AC & High-Voltage DC Input: Operates across 380 to 500 VAC nominal three-phase (342 to 575 VAC maximum, 620 VAC 5 s surge) and 450 to 810 VDC with 240 W single-phase dropped-phase capability.
  • 150% Peak Boost Power for 60 Seconds: Delivers 10 A (240 W) continuous and 15 A (360 W) peak output for up to 60 seconds into 20,000 µF max capacitive loads without nuisance breaker tripping.
  • High Conversion Efficiency & Low Standby Draw: Achieves 93.1% efficiency at 400 VAC and 93.2% at 500 VAC with 1.6 W to 1.9 W maximum no-load power consumption and 10-year typical electrolytic capacitor life.
  • Reinforced 6,400 VAC Input-to-Output Isolation: Provides 6,400 VAC (1 min) input-to-output, 2,210 VAC input-to-ground, and 1,390 VAC output-to-ground/signal dielectric strength with under 1 mA leakage at 575 VAC.
  • Built-In Control Signals & Parallel Droop Mode: Includes a >95% DC Good relay contact, remote on/off enable (<4 V or closed contact), green DC OK LED, and front DIP switch for N+1 or capacity paralleling.
  • Industrial Immunity & Global Safety Certifications: Certified to IEC/EN/UL/CSA 61010-1, 61010-2-201, and 62368-1 with Class B EN 55011 emissions and EN 61000-4-2 through -4-11 industrial EMC immunity.
  • Ultra-Slim 55 mm Aluminum DIN Rail Chassis: Measures 55 × 129 × 138.2 mm (2.17 × 5.08 × 5.44 in) at 780 g, supporting -40 °C cold start-up and full-load convection cooling up to +55 °C.

Technical Specifications

Manufacturer TDK-Lambda
Manufacturer Part Number (MPN) DRB240-24-3-A0
Alternate Part Number DRB240243A0
Product Series DRB120-3 – DRB960-3 Series (DRB240-3)
Product Category Redundancy Modules
Component Type Three-Phase AC-DC Industrial DIN Rail Power Supply
Termination & Coating Option Code -A0 (Screw Terminals, Standard Uncoated PCB)
Circuit Topology Variable-Frequency Switching Converter (50–135 kHz) with Parallel Droop Mode
Nominal Output Voltage 24 VDC
Output Voltage Adjustment Range 22.5 to 29 VDC (via Front-Panel Trimmer)
Output Voltage Tolerance ±3% Maximum
Rated Continuous Output Current 10 A
Peak Boost Output Current 15 A (for up to 60 seconds)
Rated Continuous Output Power 240 W
Peak Boost Output Power 360 W (150% Boost for up to 60 seconds)
Dropped-Phase Output Power 240 W (Continuous Operation on 2 Phases)
Minimum Load Requirement No Minimum Load Required (0 A)
Maximum Capacitive Load 20,000 µF
Output Ripple & Noise (+25 to +70 °C Ambient) 40 mVp-p Maximum
Output Ripple & Noise (-25 to 120 mVp-p Maximum
Line Regulation 0.05%
Load Regulation (Single-Unit / Non-Parallel Mode) 0.2%
Load Regulation (Parallel Droop Mode) 2.7%
Hold-Up Time (Minimum at 400 VAC) 20 ms
Hold-Up Time (Minimum at 500 VAC) 40 ms
Nominal AC Input Voltage Range 3-Phase 380 to 500 VAC (Safety Certified Range)
Maximum Operating AC Input Voltage Range 3-Phase 342 to 575 VAC
Input Surge Voltage Withstand 620 VAC (for 5 seconds)
DC Input Voltage Range 450 to 810 VDC (External DC Fuse Required)
Input Frequency Range 47 to 63 Hz
AC Input Current (Per Phase Maximum) 0.8 A max
DC Input Current (Maximum) 0.8 A max
Inrush Current (Typical Cold Start at 400 VAC) 25 A typical
Inrush Current (Typical Cold Start at 500 VAC) 30 A typical
Efficiency (Minimum at 400 VAC, 100% Load) 93.1%
Efficiency (Minimum at 500 VAC, 100% Load) 93.2%
Average Efficiency (at 400 VAC, EU 2019/1782) 92.8% (25%, 50%, 75%, 100% Load Average)
Average Efficiency (at 500 VAC, EU 2019/1782) 92.3% (25%, 50%, 75%, 100% Load Average)
Power Factor (Typical at 400 / 500 VAC) 0.6 typical
No-Load Power Consumption (Standby at 400 VAC) 1.6 W maximum
No-Load Power Consumption (Standby at 500 VAC) 1.9 W maximum
Internal Switching Frequency 50 to 135 kHz (Variable with Line and Load)
Overcurrent Protection (OCP / OLP) Threshold >142% of Rated Output Current
Overcurrent Protection (OCP / OLP) Mode Constant Current Limiting & Hiccup Mode (Auto-Recovery)
Overvoltage Protection (OVP) Threshold <32.7 VDC
Overvoltage Protection (OVP) Mode Auto-Recovery
Overtemperature Protection (OTP) Mode Built-In Thermal Shutdown with Auto-Recovery
Withstand Isolation Voltage (Input to Output) 6,400 VAC (1 Minute)
Withstand Isolation Voltage (Input to Ground / PE) 2,210 VAC (1 Minute)
Withstand Isolation Voltage (Output to Ground & Signals) 1,390 VAC (1 Minute)
Earth Leakage Current (at 575 VAC, 60 Hz) <1 mA
Touch Current (at 575 VAC, 60 Hz) <50 µA
Operating Ambient Temperature Range -25 °C to +70 °C (-13 °F to +158 °F)
Cold Start-Up Temperature Capability -40 °C (-40 °F)
Full-Load Operating Temperature Limit +55 °C (+131 °F) at 100% Load
High-Temperature Derating Rate (Above +55 °C) 2.4 W/°C Linear Derating (+55 °C to +70 °C)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating & Storage Humidity 95% RH Maximum (Non-Condensing)
Operating Altitude 3,000 m Nominal (Up to 6,000 m Maximum without UL Certification)
Vibration Resistance (Non-Operating on DIN Rail) IEC 60068-2-6: 2g, 10 to 500 Hz, 1 Hour per Axis (X, Y, Z)
Shock Resistance (Non-Operating on DIN Rail) IEC 60068-2-27: 30g, 11 ms ±5 ms, 3 Shocks per Axis
Expected Electrolytic Capacitor Field Life 10 Years Typical (Conservatively Rated)
MTBF (Telcordia SR-332 Issue 4) 1,100,000 Hours (at +25 °C Ambient, Full Load)
Safety Certifications & Approvals IEC/EN/UL/CSA 61010-1, IEC/EN/UL/CSA 61010-2-201, IEC/EN/UL/CSA 62368-1, CE, UKCA
Additional Design Compliance Standards Designed to meet IEC 60950-1, EN 60204-1, IEC/EN 62477-1, IEC/EN 61204-7, IEC/EN 61558-2-16, IEC 60068-2-60, IEC 60068-2-11
EMC Conducted & Radiated Emissions EN 55011 Class B, CISPR 11 Class B
EMC Harmonic Current Emissions EN 61000-3-2 Class A
EMC Electrostatic Discharge (ESD) Immunity EN 61000-4-2: ±4 kV Contact, ±8 kV Air Discharge (Criteria A)
EMC Radiated RF Susceptibility EN 61000-4-3: 10 V/m (80 MHz–1 GHz), 3 V/m (1.4–2 GHz), 1 V/m (2–2.7 GHz) (Criteria A)
EMC Electrical Fast Transient (EFT / Burst) EN 61000-4-4: Input ±4 kV (5 kHz), Output ±2 kV (5 kHz), Signal ±2 kV (5 kHz) (Criteria A)
EMC Surge Immunity EN 61000-4-5: Input L-L ±2 kV, Input L-PE ±4 kV; Output L-L ±0.5 kV, Output L-PE ±1 kV (Criteria A)
EMC Conducted RF Susceptibility EN 61000-4-6: 10 Vrms (150 kHz to 80 MHz) (Criteria A)
EMC Power Frequency Magnetic Field Immunity EN 61000-4-8: 30 A/m at 50 Hz, 60 s per Axis (X, Y, Z) (Criteria A)
EMC Voltage Dips & Interruptions Immunity EN 61000-4-11 / EN 61000-4-34 (400 VAC, 50 Hz): 70% for 500 ms (Crit A), 40% for 200 ms (Crit A), 0% for 20 ms (Crit A), 0% for 5000 ms (Crit C)
DC Good Status Relay Output Closed Contact Relay when Output Voltage >95% of Nominal
Remote On/Off Control Input Closed Contact or <4 VDC Enables Output (INHIBIT +/-)
Parallel Operation Control Front-Panel DIP Switch for Parallel Droop Mode Current Sharing
Visual Status Indicator Front-Panel Green LED (DC OK)
Input Terminal Pinout L1, L2, L3, PE (Earth) Screw Terminals
Output & Signal Terminal Pinout +V, +V, -V, -V, DC OK Relay (2 Pins), INHIBIT +/- Screw Terminals
Cooling Method Free-Air Natural Convection
Mounting Style & DIN Rail Compatibility Standard TS-35/7.5 or TS-35/15 DIN Rail Mount
Overall Width (W) 55 mm (2.17 in)
Overall Height (H) 129 mm (5.08 in)
Overall Depth (D) 138.2 mm (5.44 in)
Overall Dimensions (W × H × D) 55 × 129 × 138.2 mm (2.17 × 5.08 × 5.44 in)
Net Weight 780 g (1.72 lbs / 27.51 oz)
Enclosure Material Aluminum Housing
Manufacturer Warranty 3 Years

Industrial Applications & Compatible Systems

TDK-Lambda DRB240-24-3-A0 provides high-efficiency, three-phase 24 VDC bus power for space-constrained industrial machinery and automated control cabinets:

  • Industrial Control Cabinets & PLC/SCADA Racks: Powers programmable logic controllers, distributed I/O modules, HMI panels, and industrial Ethernet switches directly from 400 VAC or 480 VAC three-phase mains without requiring a step-down control transformer.
  • Packaging, Material Handling & Conveyor Automation: Supplies 150% peak boost power (15 A / 360 W for up to 60 seconds) to energize DC solenoid valves, pneumatic manifolds, electromagnetic brakes, and stepper/brushless DC drives.
  • Process Control & Chemical/Water Treatment Instrumentation: Delivers low-ripple (40 mVp-p) 24 VDC power with 6,400 VAC input-to-output isolation and EN 55011 Class B EMC compliance for sensitive analog transmitters, flow meters, and actuator loops.
  • Redundant & High-Availability 24 VDC Bus Systems: Parallels multiple units via the front-panel droop-mode DIP switch or pairs with TDK-Lambda DRM40 redundancy modules and DBM20 buffer modules for fault-tolerant N+1 machine power.

Installation, Thermal Management & MRO Guidelines

Installation & Engineering Guidelines: Mount the DRB240-24-3-A0 vertically onto a standard TS-35/7.5 or TS-35/15 DIN rail with unobstructed top and bottom ventilation clearances so natural convection cooling maintains full 240 W output up to +55 °C (+131 °F); above +55 °C, linearly derate output power by 2.4 W/°C up to +70 °C (maximum 204 W at +70 °C). Because cold-start inrush current is limited to 25 A at 400 VAC and 30 A at 500 VAC with 0.8 A maximum steady-state phase current, standard 3-pole C-curve or D-curve miniature circuit breakers can be used without nuisance tripping. When operating from a 450 to 810 VDC bus, install an appropriately rated external DC fuse in series with the input lines, and set the front-panel DIP switch to parallel mode before wiring multiple units together.