Description
TDK-Lambda D1SE480-72-A4 (also known as D1SE48072A4) is a high-efficiency 480W single-phase DIN rail AC-DC power supply engineered for residential, commercial, and light-industrial automation systems. Within the D1SE480 nomenclature, the -72 designator specifies a nominal 72VDC output adjustable from 70VDC to 85VDC at 6.7A continuous rated current, while the -A4 option code equips the unit with a front-panel green DC-OK status LED and an isolated DC-OK relay contact without conformal board coating. Operating across a universal 85–264VAC (90–264VAC safety certified) or 110–250VDC nominal input with active power factor correction (0.95 PF at 230VAC), it achieves up to 95.1% conversion efficiency at 240VAC and delivers a 125% peak boost rating of 8.3A (600W) for up to 200 seconds to energize high-capacitance and inductive loads without nuisance breaker tripping.
To protect downstream electronics and control panels, the D1SE480-72-A4 integrates automatic-recovery overcurrent, overvoltage, and overtemperature protection alongside a low-inrush front end (< 0.6 A²s peak energy; 20A cold start at 240VAC). Reinforced galvanic isolation withstands 5,000VDC input-to-output, 3,100VDC input-to-ground, and 750VDC output-to-ground, supported by conservatively rated electrolytic capacitors for extended field service life.
Housed in a compact 60mm × 125mm × 129mm (2.36 in × 4.92 in × 5.08 in) convection-cooled aluminum chassis for TS-35/7.5 or TS-35/15 DIN rails with tool-less push-in terminals, it operates from -25 °C to +70 °C (-40 °C start-up, full load up to +55 °C) and carries IEC/UL/EN 61010-2-201, IEC/UL/EN 62368-1 Ed.3, SEMI F47-0706, BIS, CE, and UKCA approvals.
Key Features
- 72VDC Output with 200-Second Peak Boost: Delivers 480W continuous power at 72VDC (6.7A, adjustable 70–85VDC) plus 600W (8.3A) peak boost capability for 200 seconds to handle capacitive and inductive surge loads.
- Up to 95.1% Conversion Efficiency: Achieves 92.0% efficiency at 100VAC, 93.3% at 120VAC, and 95.1% at 240VAC with 0.8W no-load power consumption, minimizing cabinet heat dissipation and energy losses.
- Universal AC and High-Voltage DC Input: Accepts 85–264VAC (90–264VAC safety certified, 50/60Hz) and 110–250VDC nominal (+20% / -15%) inputs while withstanding 300VAC input surges for up to 30 seconds.
- Ultra-Low Inrush Energy < 0.6 A²s: Limits cold-start inrush current to 9A at 100VAC, 11A at 120VAC, and 20A at 240VAC, preventing nuisance tripping on upstream miniature circuit breakers.
- 5,000VDC Reinforced I/O Isolation & Full Protection: Provides 5,000VDC input-to-output and 3,100VDC input-to-ground dielectric withstand alongside auto-recovery overcurrent, overvoltage, and overtemperature protection.
- Slim 60mm Aluminum Chassis with Push-In Terminals: Measures 60 × 125 × 129mm (2.36 × 4.92 × 5.08 in) at 900g with tool-less push-in wire terminations, front DC-OK green LED, and isolated DC-OK relay contact.
- Global Industrial Safety & SEMI F47 Compliance: Certified to IEC/UL/EN 61010-2-201, IEC/UL/EN 62368-1 Ed.3, SEMI F47-0706 voltage sag immunity, BIS, CE, and UKCA for industrial control equipment.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | D1SE480-72-A4 |
| Alternate Part Number | D1SE48072A4 |
| Product Series | D1SE Series (D1SE120 – D1SE480) |
| Product Category | Redundancy Modules |
| Component Type | AC-DC Single-Phase DIN Rail Power Supply |
| Option Code Suffix | -A4 (DC-OK Status LED & Relay, Standard Uncoated PCB) |
| Nominal Output Voltage | 72 VDC |
| Output Voltage Adjustment Range | 70 VDC to 85 VDC (via front potentiometer) |
| Rated Output Current | 6.7 A |
| Rated Output Power | 480 W |
| Peak (Boost) Output Current | 8.3 A (for 200 seconds max) |
| Peak (Boost) Output Power | 600 W (125% boost for 200 seconds max) |
| Output Ripple & Noise | 45 mVp-p max (-10 °C to +70 °C ambient) |
| Line Regulation | ±0.02% |
| Load Regulation | ±0.25% |
| Minimum Load Requirement | 0 A (No minimum load required) |
| Hold-Up Time (at 230 VAC) | 25 ms min |
| Parallel Operation Capability | Not supported (Use external redundancy module such as DRM40) |
| Nominal AC Input Voltage Range | 100 VAC to 240 VAC (Safety certified for 90 VAC to 264 VAC) |
| Operating AC Input Voltage Range | 85 VAC to 264 VAC |
| Input Surge Withstand Voltage | 300 VAC for 30 seconds |
| AC Input Frequency | 50 / 60 Hz (Safety certified) |
| DC Input Voltage Range | 110 VDC to 250 VDC nominal (+20% / -15% tolerance; external DC fuse required) |
| Maximum Input Current | 5.6 A max |
| Inrush Current (Cold Start at 100 VAC) | 9 A |
| Inrush Current (Cold Start at 120 VAC) | 11 A |
| Inrush Current (Cold Start at 240 VAC) | 20 A |
| Peak Inrush Energy (I²t) | < 0.6 A²s |
| Efficiency (at 100 VAC, Full Load) | 92.0% |
| Efficiency (at 120 VAC, Full Load) | 93.3% |
| Efficiency (at 240 VAC, Full Load) | 95.1% |
| Power Factor (at 230 VAC) | 0.95 |
| No-Load Power Consumption | 0.8 W |
| Internal Switching Frequency | 114 kHz to 209 kHz (load dependent) |
| Overcurrent Protection (OCP) Mode | Automatic recovery |
| Overvoltage Protection (OVP) Mode | Automatic recovery |
| Overtemperature Protection (OTP) Mode | Automatic recovery |
| Insulation Class | Class I (with Protective Earth) |
| Withstand Isolation Voltage (I/P to O/P) | 5,000 VDC (1 minute) |
| Withstand Isolation Voltage (I/P to GND) | 3,100 VDC (1 minute) |
| Withstand Isolation Voltage (O/P & Signals to GND) | 750 VDC (1 minute) |
| Earth Leakage Current | 0.55 mA max |
| Operating Ambient Temperature Range | -25 °C to +70 °C / -13 °F to +158 °F (-40 °C / -40 °F cold start-up) |
| Full-Load Operating Temperature Limit | +55 °C (+131 °F) at > 108 VAC input |
| High-Temperature & Low-Line Derating | Derate output power above +55 °C (+131 °F) and below 108 VAC |
| Storage Temperature Range | -40 °C to +85 °C / -40 °F to +185 °F |
| Operating & Storage Humidity | 95% RH max (non-condensing) |
| Operating Altitude | 3,000 m (9,842 ft) nominal; up to 6,000 m (19,685 ft) without UL certification |
| Vibration Resistance (Non-Operating) | IEC 60068-2-6: 2g, 10–500 Hz, 1 hour per axis (X, Y, Z) |
| Shock Resistance (Non-Operating) | 30g, 11 ms ±5 ms, 3 bumps per direction (9 bumps total) |
| Safety Certifications & Markings | IEC/UL/EN 61010-2-201, IEC/UL/EN 62368-1 Ed.3, BIS, CE, UKCA |
| Conducted & Radiated EMI Environment | Residential, commercial, and light-industrial environments |
| Harmonic Current Emissions | EN 61000-3-2 Class A |
| EMC Immunity – ESD (EN 61000-4-2) | 4 kV contact, 8 kV air discharge (Criterion A) |
| EMC Immunity – Radiated RF (EN 61000-4-3) | 10 V/m (80 MHz–1 GHz), 3 V/m (1.4–6 GHz) (Criterion A) |
| EMC Immunity – EFT/Burst (EN 61000-4-4) | 2 kV input, 1 kV output, 1 kV signal (Criterion A) |
| EMC Immunity – Surge (EN 61000-4-5) | 2 kV L-L / 4 kV L-PE (input & output), 1 kV Signal-PE (Criterion A) |
| EMC Immunity – Conducted RF (EN 61000-4-6) | 10 V/m, 80 MHz–1 GHz (Criterion A) |
| EMC Immunity – Magnetic Field (EN 61000-4-8) | 30 A/m, 50 Hz, 60 s each axis X, Y, Z (Criterion A) |
| EMC Immunity – Voltage Dips (EN 61000-4-11 / -34) | Criterion A (20 ms, 200 ms, 500 ms); Criterion C (5,000 ms) |
| Voltage Sag Immunity (SEMI F47-0706) | Criterion A (20 ms, 200 ms, 500 ms, 1,000 ms) |
| DC-OK Status Indicator | Front-panel Green LED (lit when DC output is OK) |
| DC-OK Control Signal Output | Isolated normally-open/closed relay contact (24 VDC / 1 A max rating) |
| Terminal Connection Type | Push-in spring-clamp wire terminations |
| Input Terminal Pinout | Bottom block: L/+ (Line / +DC), N/- (Neutral / -DC), PE (Protective Earth) |
| Output & Signal Terminal Pinout | Top block: +V, -V, and DC OK relay pins (13, 14) |
| Cooling Method | Natural air convection |
| Mounting Style | DIN Rail Mount (TS-35/7.5 or TS-35/15 standard rails) |
| Ingress Protection Rating | IP20 |
| Enclosure Material | Aluminum chassis |
| Overall Width (W) | 60 mm (2.36 in) |
| Overall Height (H) | 125 mm (4.92 in) |
| Overall Depth (D) | 129 mm / 129.2 mm max (5.08 in / 5.09 in) |
| Overall Dimensions (W × H × D) | 60 × 125 × 129 mm (2.36 × 4.92 × 5.08 in) |
| Net Weight | 900 g (1.98 lbs) |
| Manufacturer Warranty | 3 Years |
Industrial Applications & Compatible Systems
TDK-Lambda D1SE480-72-A4 provides a high-efficiency, compact 72VDC bulk power rail for industrial, commercial, and infrastructure control enclosures:
- 72V Servo, Stepper & DC Brushless Motor Drives: Supplies 480W continuous and 600W (8.3A) 200-second boost power to absorb regenerative and inductive acceleration peaks in automated material handling and packaging machinery.
- Telecom, PoE++ & Industrial Networking Cabinets: Powers high-voltage 72VDC distribution buses, remote base-station auxiliaries, and DC-DC point-of-load converters with 5,000VDC reinforced isolation.
- Battery Charging & Redundant DC Bus Systems: Pairs with 48V/60V battery charging regulators (using its 70–85VDC trim range) or external DIN-rail redundancy and buffer modules for uninterrupted control power.
- Building Automation, HVAC & Test Equipment: Fits tightly spaced TS-35 DIN rail panels in commercial building controllers and semiconductor test stands requiring SEMI F47-0706 voltage sag immunity.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: Mount the D1SE480-72-A4 vertically on a standard TS-35/7.5 or TS-35/15 DIN rail with terminals oriented at top and bottom to maintain unobstructed natural convection airflow across its aluminum housing. Maintain full 480W output up to +55 °C (+131 °F) at line voltages above 108VAC, applying linear thermal derating up to +70 °C (+158 °F) and under low-line AC conditions. When powering the unit from a 110–250VDC bus, install an appropriately rated external DC-approved fuse in series with the positive input line as mandated by TDK-Lambda safety guidelines; for N+1 redundant configurations, wire outputs through an external ORing module such as the TDK-Lambda DRM40 rather than direct paralleling.