D1SE480-72-A4 TDK-Lambda 480W 72VDC DIN Rail Power Supply

$259.45

TDK-Lambda D1SE480-72-A4 (D1SE48072A4) 480W 72VDC 6.7A single-phase DIN rail power supply, 85-264VAC / 110-250VDC input, 95.1% efficiency, 600W peak boost & UL/IEC.

SKU: D1SE480-72-A4 Category: Brand:

Description

TDK-Lambda D1SE480-72-A4 (also known as D1SE48072A4) is a high-efficiency 480W single-phase DIN rail AC-DC power supply engineered for residential, commercial, and light-industrial automation systems. Within the D1SE480 nomenclature, the -72 designator specifies a nominal 72VDC output adjustable from 70VDC to 85VDC at 6.7A continuous rated current, while the -A4 option code equips the unit with a front-panel green DC-OK status LED and an isolated DC-OK relay contact without conformal board coating. Operating across a universal 85–264VAC (90–264VAC safety certified) or 110–250VDC nominal input with active power factor correction (0.95 PF at 230VAC), it achieves up to 95.1% conversion efficiency at 240VAC and delivers a 125% peak boost rating of 8.3A (600W) for up to 200 seconds to energize high-capacitance and inductive loads without nuisance breaker tripping.

To protect downstream electronics and control panels, the D1SE480-72-A4 integrates automatic-recovery overcurrent, overvoltage, and overtemperature protection alongside a low-inrush front end (< 0.6 A²s peak energy; 20A cold start at 240VAC). Reinforced galvanic isolation withstands 5,000VDC input-to-output, 3,100VDC input-to-ground, and 750VDC output-to-ground, supported by conservatively rated electrolytic capacitors for extended field service life.

Housed in a compact 60mm × 125mm × 129mm (2.36 in × 4.92 in × 5.08 in) convection-cooled aluminum chassis for TS-35/7.5 or TS-35/15 DIN rails with tool-less push-in terminals, it operates from -25 °C to +70 °C (-40 °C start-up, full load up to +55 °C) and carries IEC/UL/EN 61010-2-201, IEC/UL/EN 62368-1 Ed.3, SEMI F47-0706, BIS, CE, and UKCA approvals.

Key Features

  • 72VDC Output with 200-Second Peak Boost: Delivers 480W continuous power at 72VDC (6.7A, adjustable 70–85VDC) plus 600W (8.3A) peak boost capability for 200 seconds to handle capacitive and inductive surge loads.
  • Up to 95.1% Conversion Efficiency: Achieves 92.0% efficiency at 100VAC, 93.3% at 120VAC, and 95.1% at 240VAC with 0.8W no-load power consumption, minimizing cabinet heat dissipation and energy losses.
  • Universal AC and High-Voltage DC Input: Accepts 85–264VAC (90–264VAC safety certified, 50/60Hz) and 110–250VDC nominal (+20% / -15%) inputs while withstanding 300VAC input surges for up to 30 seconds.
  • Ultra-Low Inrush Energy < 0.6 A²s: Limits cold-start inrush current to 9A at 100VAC, 11A at 120VAC, and 20A at 240VAC, preventing nuisance tripping on upstream miniature circuit breakers.
  • 5,000VDC Reinforced I/O Isolation & Full Protection: Provides 5,000VDC input-to-output and 3,100VDC input-to-ground dielectric withstand alongside auto-recovery overcurrent, overvoltage, and overtemperature protection.
  • Slim 60mm Aluminum Chassis with Push-In Terminals: Measures 60 × 125 × 129mm (2.36 × 4.92 × 5.08 in) at 900g with tool-less push-in wire terminations, front DC-OK green LED, and isolated DC-OK relay contact.
  • Global Industrial Safety & SEMI F47 Compliance: Certified to IEC/UL/EN 61010-2-201, IEC/UL/EN 62368-1 Ed.3, SEMI F47-0706 voltage sag immunity, BIS, CE, and UKCA for industrial control equipment.

Technical Specifications

Manufacturer TDK-Lambda
Manufacturer Part Number (MPN) D1SE480-72-A4
Alternate Part Number D1SE48072A4
Product Series D1SE Series (D1SE120 – D1SE480)
Product Category Redundancy Modules
Component Type AC-DC Single-Phase DIN Rail Power Supply
Option Code Suffix -A4 (DC-OK Status LED & Relay, Standard Uncoated PCB)
Nominal Output Voltage 72 VDC
Output Voltage Adjustment Range 70 VDC to 85 VDC (via front potentiometer)
Rated Output Current 6.7 A
Rated Output Power 480 W
Peak (Boost) Output Current 8.3 A (for 200 seconds max)
Peak (Boost) Output Power 600 W (125% boost for 200 seconds max)
Output Ripple & Noise 45 mVp-p max (-10 °C to +70 °C ambient)
Line Regulation ±0.02%
Load Regulation ±0.25%
Minimum Load Requirement 0 A (No minimum load required)
Hold-Up Time (at 230 VAC) 25 ms min
Parallel Operation Capability Not supported (Use external redundancy module such as DRM40)
Nominal AC Input Voltage Range 100 VAC to 240 VAC (Safety certified for 90 VAC to 264 VAC)
Operating AC Input Voltage Range 85 VAC to 264 VAC
Input Surge Withstand Voltage 300 VAC for 30 seconds
AC Input Frequency 50 / 60 Hz (Safety certified)
DC Input Voltage Range 110 VDC to 250 VDC nominal (+20% / -15% tolerance; external DC fuse required)
Maximum Input Current 5.6 A max
Inrush Current (Cold Start at 100 VAC) 9 A
Inrush Current (Cold Start at 120 VAC) 11 A
Inrush Current (Cold Start at 240 VAC) 20 A
Peak Inrush Energy (I²t) < 0.6 A²s
Efficiency (at 100 VAC, Full Load) 92.0%
Efficiency (at 120 VAC, Full Load) 93.3%
Efficiency (at 240 VAC, Full Load) 95.1%
Power Factor (at 230 VAC) 0.95
No-Load Power Consumption 0.8 W
Internal Switching Frequency 114 kHz to 209 kHz (load dependent)
Overcurrent Protection (OCP) Mode Automatic recovery
Overvoltage Protection (OVP) Mode Automatic recovery
Overtemperature Protection (OTP) Mode Automatic recovery
Insulation Class Class I (with Protective Earth)
Withstand Isolation Voltage (I/P to O/P) 5,000 VDC (1 minute)
Withstand Isolation Voltage (I/P to GND) 3,100 VDC (1 minute)
Withstand Isolation Voltage (O/P & Signals to GND) 750 VDC (1 minute)
Earth Leakage Current 0.55 mA max
Operating Ambient Temperature Range -25 °C to +70 °C / -13 °F to +158 °F (-40 °C / -40 °F cold start-up)
Full-Load Operating Temperature Limit +55 °C (+131 °F) at > 108 VAC input
High-Temperature & Low-Line Derating Derate output power above +55 °C (+131 °F) and below 108 VAC
Storage Temperature Range -40 °C to +85 °C / -40 °F to +185 °F
Operating & Storage Humidity 95% RH max (non-condensing)
Operating Altitude 3,000 m (9,842 ft) nominal; up to 6,000 m (19,685 ft) without UL certification
Vibration Resistance (Non-Operating) IEC 60068-2-6: 2g, 10–500 Hz, 1 hour per axis (X, Y, Z)
Shock Resistance (Non-Operating) 30g, 11 ms ±5 ms, 3 bumps per direction (9 bumps total)
Safety Certifications & Markings IEC/UL/EN 61010-2-201, IEC/UL/EN 62368-1 Ed.3, BIS, CE, UKCA
Conducted & Radiated EMI Environment Residential, commercial, and light-industrial environments
Harmonic Current Emissions EN 61000-3-2 Class A
EMC Immunity – ESD (EN 61000-4-2) 4 kV contact, 8 kV air discharge (Criterion A)
EMC Immunity – Radiated RF (EN 61000-4-3) 10 V/m (80 MHz–1 GHz), 3 V/m (1.4–6 GHz) (Criterion A)
EMC Immunity – EFT/Burst (EN 61000-4-4) 2 kV input, 1 kV output, 1 kV signal (Criterion A)
EMC Immunity – Surge (EN 61000-4-5) 2 kV L-L / 4 kV L-PE (input & output), 1 kV Signal-PE (Criterion A)
EMC Immunity – Conducted RF (EN 61000-4-6) 10 V/m, 80 MHz–1 GHz (Criterion A)
EMC Immunity – Magnetic Field (EN 61000-4-8) 30 A/m, 50 Hz, 60 s each axis X, Y, Z (Criterion A)
EMC Immunity – Voltage Dips (EN 61000-4-11 / -34) Criterion A (20 ms, 200 ms, 500 ms); Criterion C (5,000 ms)
Voltage Sag Immunity (SEMI F47-0706) Criterion A (20 ms, 200 ms, 500 ms, 1,000 ms)
DC-OK Status Indicator Front-panel Green LED (lit when DC output is OK)
DC-OK Control Signal Output Isolated normally-open/closed relay contact (24 VDC / 1 A max rating)
Terminal Connection Type Push-in spring-clamp wire terminations
Input Terminal Pinout Bottom block: L/+ (Line / +DC), N/- (Neutral / -DC), PE (Protective Earth)
Output & Signal Terminal Pinout Top block: +V, -V, and DC OK relay pins (13, 14)
Cooling Method Natural air convection
Mounting Style DIN Rail Mount (TS-35/7.5 or TS-35/15 standard rails)
Ingress Protection Rating IP20
Enclosure Material Aluminum chassis
Overall Width (W) 60 mm (2.36 in)
Overall Height (H) 125 mm (4.92 in)
Overall Depth (D) 129 mm / 129.2 mm max (5.08 in / 5.09 in)
Overall Dimensions (W × H × D) 60 × 125 × 129 mm (2.36 × 4.92 × 5.08 in)
Net Weight 900 g (1.98 lbs)
Manufacturer Warranty 3 Years

Industrial Applications & Compatible Systems

TDK-Lambda D1SE480-72-A4 provides a high-efficiency, compact 72VDC bulk power rail for industrial, commercial, and infrastructure control enclosures:

  • 72V Servo, Stepper & DC Brushless Motor Drives: Supplies 480W continuous and 600W (8.3A) 200-second boost power to absorb regenerative and inductive acceleration peaks in automated material handling and packaging machinery.
  • Telecom, PoE++ & Industrial Networking Cabinets: Powers high-voltage 72VDC distribution buses, remote base-station auxiliaries, and DC-DC point-of-load converters with 5,000VDC reinforced isolation.
  • Battery Charging & Redundant DC Bus Systems: Pairs with 48V/60V battery charging regulators (using its 70–85VDC trim range) or external DIN-rail redundancy and buffer modules for uninterrupted control power.
  • Building Automation, HVAC & Test Equipment: Fits tightly spaced TS-35 DIN rail panels in commercial building controllers and semiconductor test stands requiring SEMI F47-0706 voltage sag immunity.

Installation, Thermal Management & MRO Guidelines

Installation & Engineering Guidelines: Mount the D1SE480-72-A4 vertically on a standard TS-35/7.5 or TS-35/15 DIN rail with terminals oriented at top and bottom to maintain unobstructed natural convection airflow across its aluminum housing. Maintain full 480W output up to +55 °C (+131 °F) at line voltages above 108VAC, applying linear thermal derating up to +70 °C (+158 °F) and under low-line AC conditions. When powering the unit from a 110–250VDC bus, install an appropriately rated external DC-approved fuse in series with the positive input line as mandated by TDK-Lambda safety guidelines; for N+1 redundant configurations, wire outputs through an external ORing module such as the TDK-Lambda DRM40 rather than direct paralleling.