ECL10US24-T XP Power 10W 24VDC Open Frame Power Supply

$28.21

XP Power ECL10US24-T (ECL10US24T) 10W 24VDC 0.42A chassis-mount open-frame AC-DC power supply, 85–264VAC input, 3000VAC isolation, EN55032 Class B, UL 62368-1.

SKU: ECL10US24-T Category: Brand:

Description

XP Power ECL10US24-T (also known as ECL10US24T) is an ultra-compact 10W single-output AC-DC power supply from the ECL10 series, where the US24 code designates a universal-input 24VDC single output and the -T suffix specifies the chassis-mount open-frame configuration with JST pin headers. Operating across a wide 85–264VAC (120–370VDC) universal input range at 47–63Hz, this Class II double-insulated unit delivers 24.0VDC at 0.42A continuous (0.55A peak for under 30 seconds at 10% duty cycle) with 82% efficiency and less than 0.3W no-load power draw. Integrated ±5% output voltage trim allows precise rail calibration, while tight ±0.5% line regulation, 1% load regulation, and 200mV pk-pk maximum ripple ensure clean power delivery for sensitive industrial control electronics.

Housed on an open-frame chassis-mount PCB measuring 65.0 × 25.4 × 21.6mm (2.56 × 1.00 × 0.85in) and weighing just 26g (0.057lbs), the ECL10US24-T interfaces via industry-standard JST PHR-3 AC input and JST PHR-2 DC output headers. Built-in protection circuits include 115–140% Vnom overvoltage protection, 120–150% overload protection, hiccup-mode short-circuit protection with automatic recovery, and an internal T1A/250VAC input fuse. Reinforced 3000VAC input-to-output galvanic isolation, convection-cooled operation from -20°C to +70°C (full load to +50°C), EN55032 Level B EMI compliance, and UL/IEC/EN 62368-1 safety approvals make it ready for global OEM industrial deployment.

Key Features

  • Universal AC/DC Input & Standby Efficiency: Accepts 85–264VAC (47–63Hz) or 120–370VDC inputs with 82% operating efficiency and under 0.3W no-load power consumption to meet strict standby energy regulations.
  • Peak Load Capability & Trim Adjustment: Delivers 24.0VDC at 0.42A nominal (10.0W) and supports 0.55A peak bursts for under 30 seconds (10% duty cycle), plus ±5% manual Vout trim.
  • Compact Chassis-Mount Open-Frame Footprint: Measures 65.0 × 25.4 × 21.6mm (2.56 × 1.00 × 0.85in) with four 3.20mm mounting holes and JST PHR-3/PHR-2 mating headers for fast harness integration.
  • Class II Double-Insulated Architecture: Engineered with 3000VAC input-to-output reinforced galvanic isolation and Class II construction requiring no protective earth ground connection in space-constrained enclosures.
  • Comprehensive Fault & Input Protection: Integrates an internal T1A/250VAC fuse, 115–140% Vnom overvoltage protection, 120–150% overload protection, and auto-recovering hiccup-mode short-circuit protection.
  • Industrial Thermal & Altitude Resilience: Operates reliably via natural convection from -20°C to +70°C (100% load up to +50°C, linear derating to 50% at +70°C) and up to 3000m altitude.
  • Global Safety & Class B EMC Compliance: Certified to UL 62368-1, CSA C22.2 No. 62368-1-14, and IEC/EN 62368-1, meeting EN55032 Level B conducted and radiated emissions without external filtering.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) ECL10US24-T
Alternate Part Number ECL10US24T
Compatible Equipment / Series JST PHR-3 / PHR-2 Connectors, SPH-002T-P0.5S Crimps, XP Power ECL10 LOOM KIT
Product Series ECL10 Series
Product Category Open Frame PSUs
Component Type Chassis-Mount Open-Frame AC-DC Power Supply
Nominal Output Voltage 24.0 VDC
Output Voltage Adjustment Range ±5% (22.8 to 25.2 VDC via V Adj. trim potentiometer)
Rated Output Current 0.42 A
Output Current Range 0 to 0.42 A (no minimum load required)
Peak / Surge Output Current 0.55 A (<30 s duration, max. 10% duty cycle; average power ≤ 10.0 W)
Rated Output Power 10.0 W
Peak Output Power 13.2 W (<30 s duration, max. 10% duty cycle)
Number of Outputs 1 (Single Output)
Output Ripple & Noise (Max.) 200 mV pk-pk (20 MHz bandwidth)
Output Voltage Tolerance ±1% (initial set accuracy)
Line Regulation ±0.5% max.
Load Regulation 1.0% max.
Transient Recovery Time & Deviation 4% max. deviation, recovery to within 1% in 500 µs (for 25% load change)
Setup Time 3 s max. (Start-Up Delay)
Rise Time 14 ms max.
Hold-Up Time (at 115 VAC) 16 ms typical (at full load)
AC Input Voltage Range 85 to 264 VAC
DC Input Voltage Range 120 to 370 VDC
Input Frequency Range 47 to 63 Hz
Efficiency 82% typical
AC Input Current (at 230 VAC) 0.2 A rms
Inrush Current (Cold Start at 115 VAC) 20 A (at 25 °C)
Inrush Current (Cold Start at 230 VAC) 40 A (at 25 °C)
Power Factor Correction (PFC) EN 61000-3-2 Class A compliant
No-Load Power Consumption <0.3 W
Switching Frequency 70 kHz typical
Input Fuse Protection Internal T1 A / 250 VAC slow-blow fuse
Mounting Style Chassis Mount (Open Frame PCB with 4 Mounting Holes)
Cooling Method Natural Convection Cooled
Overall Width (W) 65.0 mm (2.56 in)
Overall Height (H) 21.6 mm (0.85 in)
Overall Depth (D) 25.4 mm (1.00 in)
Dimensional Tolerance ±0.5 mm (±0.02 in) for x.x mm / x.xx in; ±0.25 mm (±0.01 in) for x.xx mm / x.xxx in
Mounting Hole Pitch 58.0 × 17.4 mm (2.28 × 0.68 in), 4 × Ø3.20 mm (Ø0.126 in) holes
Net Weight 26 g (0.057 lbs / 0.92 oz)
Termination / Connector Style JST Pin Headers (Mates with Input JST PHR-3 & Output JST PHR-2 using SPH-002T-P0.5S crimps)
Input Terminal Pinout JST PHR-3 Header — Pin 1: ACL (AC Line), Pin 2: NP (No Pin / Creepage Key), Pin 3: ACN (AC Neutral)
Output & Signal Terminal Pinout JST PHR-2 Header — Pin 1: +Vo (+24 VDC), Pin 2: -Vo (0 VDC Return)
Overload Protection (OLP) Threshold 120% to 150% of rated total power
Overvoltage Protection (OVP) Threshold 115% to 140% Vnom
Short Circuit Protection (SCP) Trip and restart (hiccup mode with automatic recovery)
Withstand Isolation Voltage (I/P to O/P) 3000 VAC
Safety Protection Class Class II Construction (Double Insulated, No Earth Ground Required)
Operating Ambient Temperature Range -20 °C to +70 °C (-4 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F)
High-Temperature Derating Rate Linear derating from 100% load at +50 °C to 50% load at +70 °C (2.5% / °C)
Operating Altitude Up to 3000 m (9842 ft)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity Up to 95% RH, non-condensing
Temperature Coefficient ±0.05% / °C
Vibration Resistance 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins each axis
Safety Approvals (UL / North America) UL 62368-1, CAN/CSA C22.2 No. 62368-1-14
Safety Approvals (IEC / EN / TÜV) IEC 60950-1:2005 Ed 2, IEC 62368-1:2014, EN 62368-1:2014/A11:2017
EMC Conducted & Radiated Emissions EN 55032 Level B Conducted & Radiated
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A, EN 61000-3-3
EMC Immunity Standards EN 61000-4-2 Level 3 (Perf. Criteria A), EN 61000-4-3 10 V/m (Perf. Criteria A), EN 61000-4-4 Level 3 (Perf. Criteria A), EN 61000-4-5 Class 3 (Perf. Criteria A), EN 61000-4-6 10 Vrms (Perf. Criteria A), EN 61000-4-8 10 A/m (Perf. Criteria A), EN 61000-4-11 Dips & Interruptions (Perf. Criteria A, B, B)
MTBF (MIL-HDBK-217F) >450,000 hours (at 25 °C, Ground Benign)

Industrial Applications & Compatible Systems

The XP Power ECL10US24-T is engineered as a compact auxiliary or primary 24VDC power source for space-constrained industrial, instrumentation, and commercial OEM enclosures:

  • Industrial Process Control & Sensors: Powers 24VDC discrete proximity sensors, photoelectric switches, compact micro-PLCs, and 4–20mA loop transmitters inside tight machine junction boxes.
  • Building Automation & HVAC Controls: Supplies isolated low-standby (<0.3W) 24VDC rail power for smart thermostats, damper actuators, access control readers, and BACnet/Modbus gateways.
  • Test, Measurement & Lab Instrumentation: Provides low-noise regulated 24VDC bias rails for benchtop diagnostic analyzers, portable calibration instruments, and data acquisition front-ends.
  • Solenoid Valves & Small Actuators: Leverages its 0.55A (13.2W) 30-second peak current rating to energize 24VDC pneumatic solenoid coils and miniature relays without oversizing the base supply.

Installation, Thermal Management & MRO Guidelines

Follow these mechanical, thermal, and wiring practices during chassis integration and MRO replacement:

  • Chassis Standoff & Creepage Clearance: Mount the open-frame PCB using insulated or grounded metal standoffs through the four Ø3.20mm mounting holes while maintaining ≥4mm creepage/clearance from the solder-side primary traces to adjacent conductive walls.
  • JST Mating Harness Assembly: Terminate input and output wiring using genuine JST PHR-3 (AC line/neutral) and JST PHR-2 (+24V/-V) housings with SPH-002T-P0.5S crimp contacts, or deploy the pre-wired XP Power ECL10 LOOM KIT.
  • High-Temperature Convection Derating: Ensure unobstructed natural airflow around the 65.0 × 25.4 × 21.6mm board; above +50°C ambient, derate continuous output load linearly at 2.5%/°C down to 5.0W (0.21A) at +70°C.
  • Upstream Branch Protection: Because the internal T1A/250VAC fuse is non-serviceable and cold-start inrush reaches 40A at 230VAC, protect AC feed lines with a slow-blow fuse or Type-C miniature circuit breaker.