ECL10US03-T XP Power 8.6W 3.3VDC Chassis Open Frame PSU

$27.65

XP Power ECL10US03-T (ECL10US03T) 8.6W 3.3VDC 2.6A chassis-mount open-frame AC-DC power supply, 85–264VAC input, 3000VAC isolation, EN55032 Class B & UL 62368-1.

SKU: ECL10US03-T Category: Brand:

Description

XP Power ECL10US03-T (also known as ECL10US03T) is an ultra-compact, single-output open-frame AC-DC power supply from the 10 W ECL10 series, where the US03 code designates a universal-input single 3.3 VDC rail and the -T suffix specifies the chassis-mount open-frame mechanical format with JST connectors. Engineered around a 70 kHz Class II switching topology, it accepts wide-range 85–264 VAC (47–63 Hz) or 120–370 VDC inputs while drawing under 0.3 W at no load and delivering 8.6 W continuous power (2.60 A nominal, 3.38 A peak for up to 30 seconds at 10% duty cycle) at 72% efficiency. Tight voltage regulation is maintained with ±1% initial set accuracy, ±5% output trim capability via onboard potentiometer, ±0.5% maximum line regulation, 1% maximum load regulation, and low 50 mV pk-pk ripple and noise across a 20 MHz bandwidth.

Packaged in a lightweight 26 g (0.057 lbs) open-frame chassis measuring 65.0 × 25.4 × 21.6 mm (2.56 × 1.00 × 0.85 in), the unit mounts securely via four 3.20 mm (0.126 in) corner holes and interfaces through JST PHR-3 (AC input) and JST PHR-2 (DC output) headers. Comprehensive fault protection includes 120–150% overload protection, 195–216% overvoltage protection tailored for 3.3 V models, and auto-recovering hiccup-mode short-circuit protection alongside 3000 VAC input-to-output galvanic isolation. Rated for natural convection cooling across -20 °C to +70 °C (-4 °F to +158 °F) with linear derating above +50 °C and up to 3000 m altitude, it carries full UL 62368-1, IEC/EN 62368-1, and EN 55032 Level B emissions compliance.

Key Features

  • Precision 3.3 VDC Low-Voltage Output: Delivers 8.6 W continuous power at 2.60 A nominal and 3.38 A peak (under 30 seconds, 10% duty cycle) with ±1% initial accuracy and ±5% onboard voltage trim.
  • Universal AC/DC Input & Standby Efficiency: Operates across 85–264 VAC (47–63 Hz) or 120–370 VDC with 0.2 A rms input current at 230 VAC and ultra-low under 0.3 W no-load power consumption.
  • Low Noise & Fast Transient Recovery: Limits output ripple and noise to 50 mV pk-pk (20 MHz bandwidth) while recovering within 1% in 500 µs (4% max deviation) after a 25% load step.
  • Compact Chassis-Mount Open-Frame Footprint: Measures 65.0 × 25.4 × 21.6 mm (2.56 × 1.00 × 0.85 in) and weighs 26 g (0.057 lbs) with four 3.20 mm mounting holes and JST PHR-3/PHR-2 connectors.
  • Class II Construction & 3000 VAC Isolation: Eliminates earth-ground leakage concerns via double-insulated Class II design providing 3000 VAC input-to-output isolation and an internal T1 A / 250 VAC input fuse.
  • Full Fault Protection Suite: Integrates 120–150% overload protection, 195–216% Vnom overvoltage protection, and automatic trip-and-restart hiccup short-circuit protection for continuous industrial reliability.
  • Wide Thermal & Altitude Envelope: Operates under natural convection from -20 °C to +70 °C (-4 °F to +158 °F) with full load up to +50 °C (50% at +70 °C) and 3000 m maximum altitude.
  • Global ITE/AV Safety & Class B EMC: Certified to UL 62368-1, CSA C22.2 No. 62368-1-14, IEC/EN 62368-1, and EN 55032 Level B conducted/radiated emissions without external filtering.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) ECL10US03-T
Alternate Part Number ECL10US03T
Product Series ECL10 Series (ECL 5–30W Family)
Product Category Open Frame PSUs
Component Type Open-Frame Chassis-Mount AC-DC Power Supply
Circuit Topology Single-Output Isolated Switching Converter (Class II, 70 kHz)
Nominal Output Voltage 3.3 VDC
Output Voltage Adjustment Range ±5% (via onboard V Adj. potentiometer)
Rated Output Current 2.60 A
Output Current Range 0 to 2.60 A (No minimum load required)
Peak / Surge Output Current 3.38 A (<30 s duration, max. 10% duty cycle; average power not to exceed nominal)
Rated Output Power 8.6 W (10 W Series Frame)
Number of Outputs 1 (Single Output)
Output Ripple & Noise (Max.) 50 mV pk-pk (20 MHz bandwidth)
Output Voltage Tolerance ±1% (Initial Set Accuracy)
Line Regulation ±0.5% max.
Load Regulation 1% max.
Transient Recovery Time & Deviation 500 µs recovery to within 1% (4% max. deviation for a 25% load change)
Setup Time 3 s max. (Start-Up Delay)
Rise Time 14 ms max. (Start-Up Rise Time)
Hold-Up Time (at 115 VAC) 16 ms typical (at full load)
AC Input Voltage Range 85 to 264 VAC (Single-Phase)
DC Input Voltage Range 120 to 370 VDC
Input Frequency Range 47 to 63 Hz
Efficiency 72% typical
AC Input Current (at 230 VAC) 0.2 A rms max.
Inrush Current (Cold Start at 115 VAC) 20 A (at 25 °C)
Inrush Current (Cold Start at 230 VAC) 40 A (at 25 °C)
Power Factor (PF at 230 VAC) EN 61000-3-2 Class A compliant
No-Load Power Consumption <0.3 W
Input Protection Internal T1 A / 250 VAC Fuse
Switching Frequency 70 kHz typical
Mounting Style Chassis Mount (Open Frame, 4x ø3.20 mm / ø0.126 in mounting holes)
Cooling Method Natural Convection Cooled
Overall Width (W) 65.0 mm (2.56 in)
Overall Height (H) 21.6 mm (0.85 in)
Overall Depth (D) 25.4 mm (1.00 in)
Dimensional Tolerance x.x = ±0.5 mm (x.xx = ±0.02 in); x.xx = ±0.25 mm (x.xxx = ±0.01 in)
Mounting Hole Pitch 58.0 × 17.4 mm (2.28 × 0.68 in)
Net Weight 26 g (0.057 lbs)
Termination / Connector Style Mating JST Wire-to-Board Headers (Optional 300 mm harness: ECL10 LOOM KIT)
Input Terminal Pinout JST PHR-3 Mating Connector (Crimps: SPH-002T-P0.5S) — Pin 1: ACL, Pin 2: NC, Pin 3: ACN
Output & Signal Terminal Pinout JST PHR-2 Mating Connector (Crimps: SPH-002T-P0.5S) — Pin 1: -Vo, Pin 2: +Vo
Overload Protection (OLP) Threshold 120% to 150% of rated total output power
Overvoltage Protection (OVP) Threshold 195% to 216% of nominal output voltage (specific to 3.3 V models)
Short Circuit Protection (SCP) Trip and restart (automatic hiccup mode recovery)
Withstand Isolation Voltage (I/P to O/P) 3000 VAC
Earth Leakage Current Class II construction (no protective earth ground connection)
Operating Ambient Temperature Range -20 °C to +70 °C (-4 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F)
High-Temperature Derating Rate Linear derating from 100% load at +50 °C (+122 °F) to 50% load at +70 °C (+158 °F)
Altitude Derating Rated up to 3000 m maximum operating altitude
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 95% RH max., non-condensing
Temperature Coefficient 0.05% / °C
Vibration Resistance 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins each axis
Safety Approvals (UL / North America) UL 62368-1, CAN/CSA C22.2 No. 62368-1-14
Safety Approvals (IEC / EN / TÜV) IEC 60950-1:2005 Ed. 2, IEC 62368-1:2014, EN 62368-1:2014/A11:2017
EMC Conducted & Radiated Emissions EN 55032 Level B (Conducted & Radiated)
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A, EN 61000-3-3
EMC Immunity Standards EN 61000-4-2 Level 3 (Perf. Criteria A), EN 61000-4-3 10 V/m 80% mod (Perf. Criteria A), EN 61000-4-4 Level 3 (Perf. Criteria A), EN 61000-4-5 Installation Class 3 (Perf. Criteria A), EN 61000-4-6 10 Vrms (Perf. Criteria A), EN 61000-4-8 10 A/m (Perf. Criteria A), EN 61000-4-11 30% 10 ms / 60% 100 ms / 100% 5000 ms (Perf. Criteria A, B, B)
MTBF (MIL-HDBK-217F) >450,000 hours (at 25 °C, Ground Benign)
Environmental Compliance RoHS Compliant

Industrial Applications & Compatible Systems

The XP Power ECL10US03-T provides a compact, double-insulated 3.3 VDC auxiliary rail for space-constrained OEM electronics and industrial control hardware:

  • Embedded Microcontrollers & FPGA Logic Boards: Powers 3.3 VDC digital logic, ARM processors, and communication transceivers inside industrial instrumentation without needing a chassis earth connection.
  • Factory Automation Sensors & Smart Gateways: Supplies low-ripple 3.3 VDC power to IoT edge nodes, protocol converters, and distributed I/O modules mounted inside compact enclosures.
  • Test, Measurement & Benchtop Instrumentation: Supports portable analyzers, data loggers, and diagnostic equipment requiring EN 55032 Level B low-emission power conversion.
  • Access Control & Building Management Panels: Drives RFID readers, smart relays, and security controllers operating directly from universal 85–264 VAC or 120–370 VDC facility buses.

Installation, Thermal Management & MRO Guidelines

Observe these mechanical, thermal, and wiring practices to ensure full isolation and long-term reliability during installation:

  • Chassis Standoff & Creepage Clearance: Mount the open-frame PCB on insulated or metallic standoffs using the four 3.20 mm (0.126 in) corner holes (58.0 × 17.4 mm pitch), maintaining adequate creepage and clearance beneath the solder side.
  • High-Temperature Convection Derating: Allow unobstructed airflow around the 21.6 mm profile; operate at 100% load (8.6 W) up to +50 °C (+122 °F) and derate linearly to 50% load (4.3 W) at +70 °C (+158 °F).
  • Mating JST Connector Assembly: Terminate input wiring with a JST PHR-3 housing (using SPH-002T-P0.5S crimps or XP Power ECL10 LOOM KIT) leaving the center pin unloaded for mains creepage, and use a JST PHR-2 housing for the 3.3 VDC output.
  • Upstream Breaker & Inrush Coordination: Account for the 40 A cold-start inrush current at 230 VAC (20 A at 115 VAC) and internal T1 A / 250 VAC fuse when selecting upstream circuit protection on multi-unit AC branches.