Description
Delta DRL-24V240W1AA (also known as DRL24V240W1AA) is an industrial 240W single-phase AC-DC DIN rail power supply from the convection-cooled LYTE Series. Within Delta’s factory model numbering structure, the 1AA suffix designates a single-phase Delta standard configuration built with a 4-pin output terminal block without the optional DC OK relay contact (distinguishing it from the 6-pin DRL-24V240W1AS variant). Engineered around an active Power Factor Correction (PFC) front end (`PF > 0.95`) and a PWM converter stage operating in constant voltage and constant current (`CC & CV`) modes, the unit accepts a universal 85–264 VAC (`47–63 Hz`) or 120–375 VDC input and delivers a tightly regulated 24 VDC output at 10.0 A (front-panel adjustable from 22 to 28 VDC). It achieves up to 90.0% conversion efficiency at 230 VAC (`88.0% at 115 VAC`), `< 0.5%` line regulation, `< 1.0%` load regulation, and low output ripple and noise (`< 120 mVpp` from `0 °C to +70 °C`) while starting smoothly into reactive loads up to 8,000 µF.
Housed in a rugged SGCC steel cover and aluminum chassis measuring 60.0 mm W × 123.6 mm H × 117.6 mm D (`2.36 in × 4.87 in × 4.63 in`) and weighing 0.80 kg (`1.76 lbs`), the supply snaps directly onto standard EN 60715 TS-35 DIN rails. Its printed circuit board assemblies feature factory-dipped conformal coating to shield precision circuit nodes against conductive dust, humidity, and industrial chemical pollutants. Comprehensive protection circuitry includes continuous current (constant-current droop) overload protection (`105–150%` rated load), non-latching hiccup-mode short-circuit protection, and latch-mode overvoltage (`28.8–35.2 V` SELV) and overtemperature safeguards alongside 3.0 kVAC input-to-output galvanic isolation. Operating across an ambient range of -20 °C to +70 °C (`-4 °F to +158 °F`) with full rated output up to +50 °C at 230 VAC and up to 5,000 m (`16,400 ft`) altitude, it carries full UL 508, IEC/EN/UL 62368-1, EN 55032 Class B, and SEMI F47 certifications.
Key Features
- Regulated 240W / 10A Output with Constant-Current Drive: Delivers 24 VDC at 10.0 A (adjustable 22–28 VDC via front potentiometer) with built-in constant-current overload limiting for reliable startup into inductive motors, solenoids, and 8,000 µF capacitive loads.
- Universal AC/DC Input & Active Power Factor Correction: Operates seamlessly across 85–264 VAC (47–63 Hz) and 120–375 VDC bus inputs with integrated active PFC achieving a power factor above 0.95 at both 115 VAC and 230 VAC.
- High 90.0% Efficiency & Low Thermal Dissipation: Reaches 90.0% typical efficiency at 230 VAC (88.0% at 115 VAC), limiting full-load cabinet heat dissipation to 25.44 W and no-load standby consumption to just 2.14 W.
- Conformal Coated PCBAs for Harsh Environments: Dip-coated internal circuit boards protect electronic nodes against ionizable salt, moisture, and chemical contaminants in demanding factory automation and process control enclosures.
- Wide -20°C to +70°C Operation & 5,000m Altitude Rating: Convection-cooled chassis delivers 100% full-rated 240W power up to +50 °C at 230 VAC (+40 °C at 115 VAC) at altitudes up to 5,000 meters (16,400 feet).
- Multi-Stage Industrial Fault Protection Suite: Combines 105–150% continuous-current overload protection, auto-recovering hiccup short-circuit protection, latch-mode overvoltage (28.8–35.2 V) and overtemperature shutdown, and an internal T6.3AH/250V AC line fuse.
- 3.0 kVAC Galvanic Isolation & SEMI F47 Sag Immunity: Provides 3.0 kVAC input-to-output and 2.0 kVAC input-to-ground isolation alongside SEMI F47-0706 voltage sag immunity at 200 VAC for semiconductor and precision manufacturing tools.
- Global UL 508 & Class B EMC Compliance: Certified to UL 508 Industrial Control Equipment, IEC/EN/UL 62368-1, and EN 55032 Class B emissions with >700,000 hours Telcordia SR-332 MTBF and a 10-year expected electrolytic capacitor lifetime.
Technical Specifications
| Manufacturer | Delta |
|---|---|
| Manufacturer Part Number (MPN) | DRL-24V240W1AA |
| Alternate Part Number | DRL24V240W1AA |
| Compatible Equipment / Series | Delta DRR-20N / DRR-20A Redundancy Modules, Industrial PLCs, HMIs, Sensors, and 24 VDC Control Panels |
| Product Series | LYTE Series (DRL-24V240W1A) |
| Product Category | PSU Mounting Brackets |
| Component Type | AC-DC Industrial DIN Rail Power Supply (Standard Version without DC OK Relay) |
| Circuit Topology | Switched-Mode Power Supply (SMPS) with Active PFC + PWM Converter (CC & CV Mode) |
| Nominal Output Voltage | 24 VDC |
| Output Voltage Adjustment Range | 22 to 28 VDC (via front-panel potentiometer) |
| Rated Output Current | 10.0 A |
| Rated Output Power | 240 W |
| Number of Outputs | 1 Output (Single Channel) |
| Output Ripple & Noise (Max.) | < 120 mVpp (0 °C to +70 °C) / < 240 mVpp (< 0 °C to -10 °C) / < 360 mVpp (< -10 °C to -20 °C) at 20 MHz BW |
| Output Voltage Tolerance | ±2.0% (Factory Set Point Tolerance) |
| Line Regulation | < 0.5% (at 85–264 VAC input, 100% load) |
| Load Regulation | -10 °C to +70 °C) / < 1.5% (0–100% load at ≤ -10 °C to -20 °C) |
| Setup Time | 1,000 ms typ. (at 115 / 230 VAC full load) |
| Rise Time | 100 ms typ. (at nominal input, 100% load) |
| Hold-Up Time (at 115 VAC) | 10 ms typ. (at 100% load) |
| Hold-Up Time (at 230 VAC) | 16 ms typ. (at 100% load) |
| Dynamic Load Response | ±10% (±2,400 mVpp max. overshoot/undershoot at 0–100% load step, 0.1 A/µs slew rate, 5–100 Hz 50% duty cycle) |
| Max. Capacitive Load | 8,000 µF |
| AC Input Voltage Range | 85 to 264 VAC |
| DC Input Voltage Range | 120 to 375 VDC (Fulfills test conditions for DC input) |
| Nominal Input Voltage | 100 to 240 VAC (Single-Phase) |
| Input Frequency Range | 47 to 63 Hz (50/60 Hz Nominal) |
| Efficiency (at 115 VAC) | 88.0% typ. (at 100% load) |
| Efficiency (at 230 VAC) | 90.0% typ. (at 100% load) |
| AC Input Current (at 115 VAC) | 2.8 A typ. (at 100% load) |
| AC Input Current (at 230 VAC) | 1.4 A typ. (at 100% load) |
| Inrush Current (Cold Start at 115 VAC) | 20 A typ. |
| Inrush Current (Cold Start at 230 VAC) | 40 A typ. |
| Power Factor (PF at 115 VAC) | > 0.95 (at 100% load) |
| Power Factor (PF at 230 VAC) | > 0.95 (at 100% load) |
| Power Factor Correction (PFC) | Active PFC (EN 61000-3-2 Class A Compliant) |
| No-Load Power Consumption | 4.62 W max. (at 115 VAC) / 2.14 W max. (at 230 VAC) |
| Full-Load Power Dissipation | 31.53 W max. (at 115 VAC) / 25.44 W max. (at 230 VAC) |
| Internal Input Fuse | T 6.3 A H / 250 V (Internal Slow-Blow Fuse at Line L Pin) |
| Mounting Style | DIN Rail TS-35 (Standard 35 mm DIN Rail per EN 60715) |
| Cooling Method | Free Air Convection (Natural Convection; Acoustic Noise < 25 dBA at 1 m) |
| Overall Width (W) | 60.0 mm (2.36 in) |
| Overall Height (H) | 123.6 mm (4.87 in) |
| Overall Depth (D) | 117.6 mm (4.63 in) |
| Net Weight | 0.80 kg (1.76 lbs / 28.22 oz) |
| Termination / Connector Style | Screw Terminal Blocks (Flexible cables require ferrules per EN/UL 62368-1) |
| Input Terminal Pinout | Bottom Terminal Block (3 Pins, Rated 600 V / 35 A): Pin 1 = L (Line), Pin 2 = N (Neutral), Pin 3 = PE (Protective Earth) |
| Output & Signal Terminal Pinout | Top Terminal Block (4 Pins, Rated 300 V / 28 A): Pins 1–2 = +V (Positive Output), Pins 3–4 = -V (Negative Output); No DC OK Relay on 1AA |
| Status Indicator | Green LED (DC OK) |
| Terminal Wire Gauge Range | 16 to 12 AWG (Input & Output Terminals, Min. 60 °C / 75 °C Copper Wire) |
| Enclosure / Potting Material | SGCC Sheet Steel Case Cover / Aluminum Chassis with Conformal Coated PCBAs |
| Overload Protection (OLP) Threshold | 105% to 150% of rated output current |
| Overload Protection (OLP) Mode | Continuous Current Mode (Constant Current voltage droop; auto-recovery upon fault removal) |
| Overvoltage Protection (OVP) Threshold | 28.8 to 35.2 VDC (SELV Output) |
| Overvoltage Protection (OVP) Mode | Latch Mode (Shut down output; recycle AC input power to restart) |
| Overtemperature Protection (OTP) Mode | Latch Mode (Shut down output; lower ambient temperature/load and recycle AC input to restart) |
| Short Circuit Protection (SCP) | Hiccup Mode, Non-Latching (Auto-recovery when short circuit fault is removed) |
| Redundant & Parallel Operation | Supported (Redundant 1+1 via external DRR-20N/20A module with 0.45–0.50 V delta; Parallel power boost within 25 mV balance) |
| Withstand Isolation Voltage (I/P to O/P) | 3.0 kVAC (3,000 VAC, Reinforced SELV Isolation) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2.0 kVAC (2,000 VAC, Class I with PE Connection) |
| Withstand Isolation Voltage (O/P to FG / Case) | 0.5 kVAC (500 VAC) |
| Earth Leakage Current | < 1.0 mA (at 264 VAC) |
| Operating Ambient Temperature Range | -20 °C to +70 °C (-4 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 230 VAC / +40 °C (+104 °F) at 115 VAC |
| High-Temperature Derating Rate | 2.5% / °C above +50 °C (at 230 VAC) / 1.67% / °C above +40 °C (at 115 VAC) |
| Low-Line Input Derating | 1.0% / VAC below 100 VAC (Down to 85% load at 85 VAC; 0% derating from 100 to 264 VAC) |
| Altitude Derating | 0 to 5,000 m (0 to 16,400 ft) Operating Altitude |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 5% to 95% RH (Non-Condensing, Pollution Degree 2) |
| Vibration Resistance | Operating: IEC 60068-2-6 Sine 10–500 Hz, 2 G peak (19.6 m/s²), 0.35 mm, 60 min X-axis; Non-Operating: Random 5–500 Hz, 2.09 Grms |
| Shock Resistance | Operating: IEC 60068-2-27 Half-Sine 10 G, 11 ms (1 time X-axis); Non-Operating: 50 G, 11 ms (3 times/axis, 9 total) |
| Ingress Protection (IP) | IP20 |
| Safety Approvals (UL / North America) | UL 508 & CSA C22.2 No. 107.1-01 Listed (File E338991), cULus UL 62368-1 & UL 60950-1 Recognized (File E131881) |
| Safety Approvals (IEC / EN / TÜV) | TÜV Bauart EN 62368-1 & EN 60950-1, CB Scheme IEC 62368-1 & IEC 60950-1, SELV |
| Safety Approvals (Regional / Global) | CE (LVD 2014/35/EU, EMC 2014/30/EU), UKCA, SEMI F47-0706 (@ 200 VAC) |
| EMC Conducted & Radiated Emissions | CISPR 32, EN/BS EN 55032 Class B, EN/BS EN 55011 Class B, FCC Title 47 Class B, GB 9254.1, EN 61000-6-3, EN 61000-6-4, EN 61204-3 |
| EMC Harmonic & Flicker Compliance | IEC/EN/BS EN 61000-3-2 Class A (GB 17625.1), IEC/EN/BS EN 61000-3-3 |
| EMC Immunity Standards | EN 61000-6-1, EN 61000-6-2, EN 55024, IEC 61000-4-2 (ESD Level 4: 15 kV Air / 8 kV Contact), IEC 61000-4-3 (RF 10 V/m Level 3), IEC 61000-4-4 (EFT 2 kV Level 3), IEC 61000-4-5 (Surge Level 4: 4 kV CM / 2 kV DM), IEC 61000-4-6 (Conducted 10 Vrms Level 3), IEC 61000-4-8 (Magnetic 30 A/m Level 4), IEC 61000-4-11 (Voltage Dips), IEC 61000-4-12 (Ring Wave Level 3: 2 kV CM / 1 kV DM), SEMI F47-0706 |
| MTBF (Telcordia SR-332 / Bellcore) | > 700,000 Hours (at 100 VAC input, 100% load, +25 °C ambient; 10-Year Expected Capacitor Lifetime at 50% load, +40 °C) |
| Environmental Compliance | RoHS Compliant |
Industrial Applications & Compatible Systems
The Delta DRL-24V240W1AA is engineered for cost-effective, high-reliability 24 VDC power distribution across industrial automation and machinery applications:
- Factory Automation & PLC Control Cabinets: Powers programmable logic controllers (PLCs), distributed I/O racks, HMI touch panels, and industrial Ethernet switches requiring clean `< 120 mVpp` SELV power.
- Inductive & Capacitive Actuator Loads: Drives 24 VDC solenoid valves, pneumatic manifolds, contactor coils, DC relays, and motor starters using its constant-current overload characteristic and `8,000 µF` capacitive startup capability.
- Semiconductor & Process Equipment: Meets `SEMI F47-0706` voltage sag immunity at `200 VAC` and features conformal-coated PCBAs to withstand corrosive air and dust in semiconductor fabrication, wastewater, and chemical dosing skids.
- Material Handling, Packaging & Building Automation: Supplies 240W continuous DC power for conveyor sensor arrays, barcode scanners, automated bottling lines, and commercial HVAC control panels.
Installation, Thermal Management & MRO Guidelines
Ensure optimal thermal performance, protection coordination, and electrical safety during cabinet integration by following these engineering practices:
- Convection Cooling Clearance Zones: Mount vertically on a standard `TS-35` DIN rail with the input terminal block at the bottom, maintaining at least `50 mm` (`1.97 in`) top clearance, `180 mm` (`7.09 in`) bottom clearance, and `10 mm` (`0.39 in`) lateral spacing to adjacent heat-generating devices.
- High-Temperature & Low-Line Derating: Apply a linear thermal derating of `2.5% / °C` above `+50 °C` at `230 VAC` (down to `50%` load / `120W` at `+70 °C`) or `1.67% / °C` above `+40 °C` at `115 VAC`, and derate output load by `1.0% / VAC` when operating below `100 VAC`.
- Upstream Breaker Sizing & Wiring Termination: Account for the `40 A` (`230 VAC`) / `20 A` (`115 VAC`) cold-start inrush peak by selecting a Type C or D circuit breaker, and terminate `16–12 AWG` copper conductors (`60 °C / 75 °C` rated) with insulated ferrules on flexible wires.
- 1+1 Redundant & Parallel Bus Balancing: For redundant operation with an external `DRR-20N` or `DRR-20A` module, stagger the master and slave output voltages by `0.45 to 0.50 V`; for direct parallel load sharing, match both supplies within `25 mV` under identical independent load.