HDL3000PS250 XP Power 3000W 250VDC Chassis Power Supply

$1,487.91

XP Power HDL3000PS250 3000W 250VDC 12A programmable chassis AC-DC power supply, 90-264VAC input, 0-105% V/I programming, I2C/RS485, and UL/EN 62368-1 approvals.

SKU: HDL3000PS250 Category: Brand:

Description

XP Power HDL3000PS250 is an industrial 3000W high-voltage programmable AC-DC enclosed power supply from the HDL3000 HV series, engineered for precision high-voltage DC bus regulation and automated test architectures. Decoding the OEM part nomenclature, HDL3000 identifies the 3kW high-density fan-cooled platform, PS denotes the standard single-output programmable chassis configuration, and 250 specifies the 250 VDC nominal output voltage. Operating from a universal single-phase 90 to 264 VAC (47–63 Hz) input with active power factor correction (PF 0.98 at 115 VAC / 0.95 at 230 VAC), it delivers 3000 W (12.0 A) at high-line input (180–264 VAC) and 2000 W (8.0 A) at low-line input (90–140 VAC). The multi-stage PFC and variable-frequency PWM topology achieves 91% typical efficiency while supporting full 0 to 105% output voltage (0–262.5 VDC) and current (0–12.6 A) programming via 0–5 VDC analog voltage, 0–5 kΩ resistance, onboard potentiometer trim (±5%), or digital I²C and RS-485 interfaces.

Housed in a rugged 2U-compatible chassis measuring 170.0 mm (W) × 65.0 mm (H) × 301.5 mm (D) (6.69 in × 2.52 in × 11.87 in) including connectors and weighing 3.3 kg (7.26 lbs), the unit integrates load- and temperature-controlled forced-air cooling. System integration is streamlined through a 3-pole AC input barrier block, dual M4 high-current DC output studs, and a 24-pin JST PHDR-24VS (CN5) control header providing remote inhibit (EN+/EN-), open-drain Power OK, selectable 5 VDC / 0.5 A or 9 VDC / 0.3 A auxiliary standby, and active current sharing with an internal ORing diode for up to 8 parallel units. Comprehensive protection encompasses tracking overvoltage protection (OVP with AC recycle reset), 105% constant-current overload protection (OLP), auto-recovering short-circuit protection (SCP), and overtemperature shutdown (OTP), backed by 3000 VAC input-to-output galvanic isolation, a -20 °C to +60 °C operating range (full power to +50 °C), and full UL/EN/IEC 62368-1 and EN 55032 Class A compliance.

Key Features

  • Full 0–105% Voltage & Current Programming: Enables continuous adjustment of output voltage from 0 to 262.5 VDC (±2% tolerance) and current from 0 to 12.6 A (±3% tolerance) via 0–5 VDC analog, 0–5 kΩ resistor, or digital bus.
  • High-Density 3000W High-Voltage Output: Delivers 250 VDC at 12.0 A (3000 W) across 180–264 VAC high-line inputs and 8.0 A (2000 W) at 90–115 VAC low-line inputs with 91% conversion efficiency.
  • Digital I²C & RS-485 Telemetry Interface: Integrates isolated +5VC/GND1 pins, I²C serial clock/data (SCL/SDA), and differential RS-485 (DA+/DA-) lines on connector CN5 for automated PLC or PC supervision.
  • 8-Unit Active Current Sharing & ORing Diode: Supports parallel operation of up to 8 supplies sharing load within 5% accuracy, featuring an internal ORing diode for seamless N+1 redundancy and 24 kW scaling.
  • Selectable Dual-Voltage Standby & Remote Control: Provides a continuous 5 VDC at 0.5 A or user-selectable 9 VDC at 0.3 A auxiliary output alongside remote enable (EN+/EN-) and open-drain Power OK signaling.
  • Comprehensive Protection & 3000 VAC Isolation: Incorporates tracking OVP (7% tolerance, latch-off reset), 105% constant-current OLP, auto-recovery OTP/SCP, and 3000 VAC input-to-output reinforced dielectric insulation.
  • Intelligent Thermal Management & Wide Operating Envelope: Employs variable-speed internal fan cooling to sustain 100% rated power from -20 °C to +50 °C, derating linearly to 50% load at +60 °C ambient.
  • Global ITE Safety & Industrial EMC Compliance: Certified to UL 62368-1, CAN/CSA C22.2 No. 62368-1-14, TÜV EN 62368-1, and CB IEC 62368-1 with EN 55032 Class A emissions and EN 55024 immunity.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) HDL3000PS250
Product Series HDL3000 HV Series
Product Category Chassis Power Supplies
Component Type Programmable High-Voltage Enclosed AC-DC Power Supply
Circuit Topology Active PFC + Variable-Frequency Switched-Mode PWM (SMPS) with Internal ORing Diode
Nominal Output Voltage 250 VDC
Output Voltage Adjustment Range 0 to 262.5 VDC (0 to 105% via external voltage/resistor/digital program); 237.5 to 262.5 VDC (±5% via onboard potentiometer)
Rated Output Current 12.0 A (at 180–264 VAC High Line); 8.0 A (at 90–140 VAC Low Line)
Output Current Range 0 to 12.6 A (0 to 105% programmable at High Line); 0 to 8.4 A (at Low Line)
Minimum Load Current 0 A
Rated Output Power 3000 W (at 180–264 VAC High Line); 2000 W (at 90–140 VAC Low Line)
Number of Outputs 1 Main Output + 1 Auxiliary Standby Output (5 VDC / 0.5 A or 9 VDC / 0.3 A selectable)
Output Ripple & Noise (Max.) 2500 mVp-p (20 MHz bandwidth, 300 mm / 12 in twisted pair terminated with 0.1 µF ceramic and 47 µF electrolytic capacitor at +25 °C)
Output Voltage Tolerance ±2% (of rated output voltage, includes setup, line, and load regulation); ±3% current tolerance
Line Regulation ±1%
Load Regulation ±1% (Main Output V1, 0–100% load); ±3% (Auxiliary Standby Output, 0–100% load)
Transient Recovery Time & Deviation <1% max. deviation (for a 25% step load change)
Setup Time 1100 ms (1.1 s typical start-up delay)
Rise Time 350 ms typical (at full load)
Hold-Up Time (at 230 VAC) 10 ms typical (at 230 VAC and full load)
AC Input Voltage Range 90 to 264 VAC (Single-Phase)
Input Frequency Range 47 to 63 Hz
Efficiency (at 230 VAC) 91% typical (at 230 VAC full load)
AC Input Current (at 115 VAC) 19.7 A typical (at 2000 W load)
AC Input Current (at 230 VAC) 14.5 A typical (at 3000 W load)
Inrush Current (Cold Start at 115 VAC) 43 A max.
Inrush Current (Cold Start at 230 VAC) 85 A max.
Power Factor (PF at 115 VAC) 0.98 typical (at full load)
Power Factor (PF at 230 VAC) 0.95 typical (at full load)
Power Factor Correction (PFC) Active PFC (70 kHz fixed switching frequency)
Switching Frequency 70 kHz (PFC); 55 to 95 kHz variable (Main PWM); 40 to 150 kHz variable (Standby)
Power Density 0.878 W/cm³ (14.4 W/in³)
Mounting Style Chassis Mount (Baseplate and side M4 threaded mounting holes, 3.0 mm / 0.12 in max. screw penetration)
Cooling Method Forced Air Convection (Internal dual fans fitted; fan speed automatically adjusts with load and internal temperature)
Overall Width (W) 170.0 mm (6.69 in)
Overall Height (H) 65.0 mm (2.52 in)
Overall Depth (D) 301.5 mm (11.87 in) including terminals; 280.0 mm (11.02 in) chassis body
Mounting Hole Pitch Baseplate: 78.0 × 237.0 mm (3.07 × 9.33 in); Side Panels: 35.0 × 208.0 mm (1.38 × 8.19 in)
Net Weight 3.3 kg (7.26 lbs)
Termination / Connector Style AC Input: 3-Pole Screw Barrier Terminal Block; DC Output: Dual M4 Busbar Bolt Terminals; Control (CN5): 24-Pin JST PHDR-24VS Header (mates with SPHD-002T-P0.5 contacts)
Input Terminal Pinout AC Mains Terminal Block: Pin 1 = Earth Ground (FG), Pin 2 = AC Line (ACL), Pin 3 = AC Neutral (ACN)
Output & Signal Terminal Pinout DC Output Busbars: POS (+) and NEG (-); Control CN5 (24-Pin): Pins 1, 10, 15 = AUX (+5V/0.5A or +9V/0.3A); Pins 2, 4, 8, 12, 14, 16 = GND; Pin 3 = POK (Power OK); Pin 5 = PAR (Current Share); Pin 6 = VSET (Aux Voltage Select); Pin 7 = EN- (Inhibit -); Pin 9 = EN+ (Inhibit +); Pin 11 = ACI (I Program); Pin 13 = VCI (V Program); Pins 17, 18 = N.C.; Pin 19 = +5VC (Isolated Digital Supply); Pin 20 = GND1 (Isolated Digital GND); Pin 21 = SCL (I²C Clock); Pin 22 = SDA (I²C Data); Pin 23 = DA- (RS-485 -); Pin 24 = DA+ (RS-485 +)
Control & Monitoring Signals Remote Enable (EN+/EN-, shipped with enable links fitted), Voltage Program (VCI: 0–5 VDC / 0–5 kΩ), Current Program (ACI: 0–5 VDC / 0–5 kΩ), Active Current Share (PAR: up to 8 units within 5%), Power OK (POK: open-drain, max. 20 mA sink, max. 40 V), Auxiliary Standby (5 VDC / 0.5 A or 9 VDC / 0.3 A)
Communication Interface Digital I²C (SCL/SDA) and Differential RS-485 (DA+/DA-) with Dedicated Isolated +5VC/GND1 Reference
Status Indicator Multi-State Diagnostic LED: Solid Green (Output OK), Solid Orange (Output OK Remote Mode), Slow Blink Green/Orange (Output Disabled), Fast Blink Red (OVP), Solid Red (OLP), Slow Blink Red (OTP), Intermittent Blink Red (Fan Fail), Short & Long Blink Red (AUX Standby Fail)
Terminal Tightening Torque 1.27 Nm (13.0 kgf·cm) for M4 mounting and terminal screws
Overload Protection (OLP) Threshold 105% of rated output power
Overload Protection (OLP) Mode Constant current limiting
Overvoltage Protection (OVP) Threshold Tracks programmed output voltage (114% to 120% at 100–105% Vout, ±7% tolerance)
Overvoltage Protection (OVP) Mode Latch-off shutdown (Recycle AC input power to reset)
Overtemperature Protection (OTP) Mode Internal thermal sensing; output shuts down and automatically recovers upon cooling
Short Circuit Protection (SCP) Continuous protection with automatic recovery
Withstand Isolation Voltage (I/P to O/P) 3000 VAC
Withstand Isolation Voltage (I/P to FG / Case) 1500 VAC
Withstand Isolation Voltage (O/P to FG / Case) 500 VAC
Earth Leakage Current 1.0 mA max. (at 264 VAC / 60 Hz)
Operating Ambient Temperature Range -20 °C to +60 °C (-4 °F to +140 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F)
High-Temperature Derating Rate Derate linearly at 5.0% per °C from 100% load at +50 °C to 50% load at +60 °C
Low-Line Input Derating 100% load (3000 W / 12.0 A) across 180–264 VAC; derates linearly from 3000 W at 180 VAC to 2000 W (8.0 A) at 140 VAC; holds 2000 W (66.7% load) from 90 to 140 VAC
Operating Altitude Up to 3000 m (9842 ft)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 20% to 90% RH (non-condensing)
Storage Relative Humidity 10% to 95% RH (non-condensing)
Temperature Coefficient ±0.02% / °C (from 0 °C to +50 °C)
Vibration Resistance 2 g (10 to 500 Hz, 10 min/cycle, 60 min per axis across X, Y, Z axes per IEC 60068-2-16 and IEC 60068-2-64)
Safety Approvals (UL / North America) UL 62368-1, CAN/CSA C22.2 No. 62368-1-14
Safety Approvals (IEC / EN / TÜV) CB Report IEC 62368-1:2014, TÜV EN 62368-1:2014/A11:2017
Safety Approvals (Regional / Global) CE Mark, UKCA
EMC Conducted & Radiated Emissions EN 55032 Class A (Conducted and Radiated)
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker)
EMC Immunity Standards EN 55024, EN 61000-4-2 (ESD Level 2/3: ±4 kV contact / ±8 kV air, Criteria A), EN 61000-4-3 (Radiated: 3 V/m, Criteria A), EN 61000-4-4 (EFT: ±1 kV, Criteria A), EN 61000-4-5 (Surge: Installation Class 3, Criteria A), EN 61000-4-6 (Conducted RF: 3 Vrms, Criteria A), Voltage Dips & Interruptions (>95% 10 ms Criteria A, >95% 5000 ms Criteria B)
MTBF (MIL-HDBK-217F) 495,000 hours (at +25 °C Ground Benign)
Environmental Compliance RoHS, REACH, 3-Year OEM Warranty

Industrial Applications & Compatible Systems

Engineered for high-voltage DC power conversion and automated control, the XP Power HDL3000PS250 serves demanding OEM equipment and industrial MRO installations:

  • EV Battery Simulation & Automated Test Equipment (ATE): Provides 0–262.5 VDC programmable voltage and 0–12.6 A current-limited profiles via I²C/RS-485 or 0–5 V analog signals for battery pack cyclers, burn-in racks, and component validation rigs.
  • Industrial Laser & Specialist UV/IR LED Curing Systems: Powers high-voltage diode laser arrays, plasma excitation stages, and industrial LED heating/curing heads requiring tight ±1% regulation and constant-current overload protection.
  • Electro-Plating, Anodizing & Cathodic Protection Rectifiers: Delivers continuous, programmable constant-current or constant-voltage DC excitation for electrochemical surface treatment baths and marine/pipeline corrosion prevention.
  • High-Voltage Robotics & Factory Automation Drives: Supplies regulated 250 VDC bus power for multi-axis servo amplifiers, automated guided vehicle (AGV) fast-charging stations, and centralized industrial control cabinets.

Installation, Thermal Management & MRO Guidelines

Follow these engineering best practices when integrating the unit into high-power enclosures:

  • Parallel Current Sharing & N+1 Redundancy Wiring: Up to 8 units can be connected in parallel via the PAR pin (Pin 5 on CN5) with built-in ORing diodes; calibrate individual no-load voltages within <0.2 VDC and limit total load to 90% of combined rated current.
  • High-Line vs. Low-Line Input & Upstream Breaker Sizing: To extract the full 3000 W (12.0 A) rating, supply 180–264 VAC high-line power; when operating at 90–140 VAC, derate maximum load to 2000 W (8.0 A) and size D-curve breakers for the 19.7 A RMS current and 85 A cold-start inrush.
  • Forced-Air Clearance & Fastener Penetration Limits: Maintain unobstructed clearance around the front/rear ventilation grilles for the variable-speed cooling fans, and ensure M4 mounting screws do not penetrate more than 3.0 mm (0.12 in) into the chassis at 1.27 Nm torque.
  • Isolated Control Reference & Remote Enable Links: Always reference analog control signals (EN+, EN-, VCI, ACI, POK) to CN5 signal ground (GND) and digital I²C/RS-485 lines to isolated GND1 (Pin 20), never to the main high-voltage NEG (-) busbar.