Description
XP Power HDL3000PS250 is an industrial 3000W high-voltage programmable AC-DC enclosed power supply from the HDL3000 HV series, engineered for precision high-voltage DC bus regulation and automated test architectures. Decoding the OEM part nomenclature, HDL3000 identifies the 3kW high-density fan-cooled platform, PS denotes the standard single-output programmable chassis configuration, and 250 specifies the 250 VDC nominal output voltage. Operating from a universal single-phase 90 to 264 VAC (47–63 Hz) input with active power factor correction (PF 0.98 at 115 VAC / 0.95 at 230 VAC), it delivers 3000 W (12.0 A) at high-line input (180–264 VAC) and 2000 W (8.0 A) at low-line input (90–140 VAC). The multi-stage PFC and variable-frequency PWM topology achieves 91% typical efficiency while supporting full 0 to 105% output voltage (0–262.5 VDC) and current (0–12.6 A) programming via 0–5 VDC analog voltage, 0–5 kΩ resistance, onboard potentiometer trim (±5%), or digital I²C and RS-485 interfaces.
Housed in a rugged 2U-compatible chassis measuring 170.0 mm (W) × 65.0 mm (H) × 301.5 mm (D) (6.69 in × 2.52 in × 11.87 in) including connectors and weighing 3.3 kg (7.26 lbs), the unit integrates load- and temperature-controlled forced-air cooling. System integration is streamlined through a 3-pole AC input barrier block, dual M4 high-current DC output studs, and a 24-pin JST PHDR-24VS (CN5) control header providing remote inhibit (EN+/EN-), open-drain Power OK, selectable 5 VDC / 0.5 A or 9 VDC / 0.3 A auxiliary standby, and active current sharing with an internal ORing diode for up to 8 parallel units. Comprehensive protection encompasses tracking overvoltage protection (OVP with AC recycle reset), 105% constant-current overload protection (OLP), auto-recovering short-circuit protection (SCP), and overtemperature shutdown (OTP), backed by 3000 VAC input-to-output galvanic isolation, a -20 °C to +60 °C operating range (full power to +50 °C), and full UL/EN/IEC 62368-1 and EN 55032 Class A compliance.
Key Features
- Full 0–105% Voltage & Current Programming: Enables continuous adjustment of output voltage from 0 to 262.5 VDC (±2% tolerance) and current from 0 to 12.6 A (±3% tolerance) via 0–5 VDC analog, 0–5 kΩ resistor, or digital bus.
- High-Density 3000W High-Voltage Output: Delivers 250 VDC at 12.0 A (3000 W) across 180–264 VAC high-line inputs and 8.0 A (2000 W) at 90–115 VAC low-line inputs with 91% conversion efficiency.
- Digital I²C & RS-485 Telemetry Interface: Integrates isolated +5VC/GND1 pins, I²C serial clock/data (SCL/SDA), and differential RS-485 (DA+/DA-) lines on connector CN5 for automated PLC or PC supervision.
- 8-Unit Active Current Sharing & ORing Diode: Supports parallel operation of up to 8 supplies sharing load within 5% accuracy, featuring an internal ORing diode for seamless N+1 redundancy and 24 kW scaling.
- Selectable Dual-Voltage Standby & Remote Control: Provides a continuous 5 VDC at 0.5 A or user-selectable 9 VDC at 0.3 A auxiliary output alongside remote enable (EN+/EN-) and open-drain Power OK signaling.
- Comprehensive Protection & 3000 VAC Isolation: Incorporates tracking OVP (7% tolerance, latch-off reset), 105% constant-current OLP, auto-recovery OTP/SCP, and 3000 VAC input-to-output reinforced dielectric insulation.
- Intelligent Thermal Management & Wide Operating Envelope: Employs variable-speed internal fan cooling to sustain 100% rated power from -20 °C to +50 °C, derating linearly to 50% load at +60 °C ambient.
- Global ITE Safety & Industrial EMC Compliance: Certified to UL 62368-1, CAN/CSA C22.2 No. 62368-1-14, TÜV EN 62368-1, and CB IEC 62368-1 with EN 55032 Class A emissions and EN 55024 immunity.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | HDL3000PS250 |
| Product Series | HDL3000 HV Series |
| Product Category | Chassis Power Supplies |
| Component Type | Programmable High-Voltage Enclosed AC-DC Power Supply |
| Circuit Topology | Active PFC + Variable-Frequency Switched-Mode PWM (SMPS) with Internal ORing Diode |
| Nominal Output Voltage | 250 VDC |
| Output Voltage Adjustment Range | 0 to 262.5 VDC (0 to 105% via external voltage/resistor/digital program); 237.5 to 262.5 VDC (±5% via onboard potentiometer) |
| Rated Output Current | 12.0 A (at 180–264 VAC High Line); 8.0 A (at 90–140 VAC Low Line) |
| Output Current Range | 0 to 12.6 A (0 to 105% programmable at High Line); 0 to 8.4 A (at Low Line) |
| Minimum Load Current | 0 A |
| Rated Output Power | 3000 W (at 180–264 VAC High Line); 2000 W (at 90–140 VAC Low Line) |
| Number of Outputs | 1 Main Output + 1 Auxiliary Standby Output (5 VDC / 0.5 A or 9 VDC / 0.3 A selectable) |
| Output Ripple & Noise (Max.) | 2500 mVp-p (20 MHz bandwidth, 300 mm / 12 in twisted pair terminated with 0.1 µF ceramic and 47 µF electrolytic capacitor at +25 °C) |
| Output Voltage Tolerance | ±2% (of rated output voltage, includes setup, line, and load regulation); ±3% current tolerance |
| Line Regulation | ±1% |
| Load Regulation | ±1% (Main Output V1, 0–100% load); ±3% (Auxiliary Standby Output, 0–100% load) |
| Transient Recovery Time & Deviation | <1% max. deviation (for a 25% step load change) |
| Setup Time | 1100 ms (1.1 s typical start-up delay) |
| Rise Time | 350 ms typical (at full load) |
| Hold-Up Time (at 230 VAC) | 10 ms typical (at 230 VAC and full load) |
| AC Input Voltage Range | 90 to 264 VAC (Single-Phase) |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency (at 230 VAC) | 91% typical (at 230 VAC full load) |
| AC Input Current (at 115 VAC) | 19.7 A typical (at 2000 W load) |
| AC Input Current (at 230 VAC) | 14.5 A typical (at 3000 W load) |
| Inrush Current (Cold Start at 115 VAC) | 43 A max. |
| Inrush Current (Cold Start at 230 VAC) | 85 A max. |
| Power Factor (PF at 115 VAC) | 0.98 typical (at full load) |
| Power Factor (PF at 230 VAC) | 0.95 typical (at full load) |
| Power Factor Correction (PFC) | Active PFC (70 kHz fixed switching frequency) |
| Switching Frequency | 70 kHz (PFC); 55 to 95 kHz variable (Main PWM); 40 to 150 kHz variable (Standby) |
| Power Density | 0.878 W/cm³ (14.4 W/in³) |
| Mounting Style | Chassis Mount (Baseplate and side M4 threaded mounting holes, 3.0 mm / 0.12 in max. screw penetration) |
| Cooling Method | Forced Air Convection (Internal dual fans fitted; fan speed automatically adjusts with load and internal temperature) |
| Overall Width (W) | 170.0 mm (6.69 in) |
| Overall Height (H) | 65.0 mm (2.52 in) |
| Overall Depth (D) | 301.5 mm (11.87 in) including terminals; 280.0 mm (11.02 in) chassis body |
| Mounting Hole Pitch | Baseplate: 78.0 × 237.0 mm (3.07 × 9.33 in); Side Panels: 35.0 × 208.0 mm (1.38 × 8.19 in) |
| Net Weight | 3.3 kg (7.26 lbs) |
| Termination / Connector Style | AC Input: 3-Pole Screw Barrier Terminal Block; DC Output: Dual M4 Busbar Bolt Terminals; Control (CN5): 24-Pin JST PHDR-24VS Header (mates with SPHD-002T-P0.5 contacts) |
| Input Terminal Pinout | AC Mains Terminal Block: Pin 1 = Earth Ground (FG), Pin 2 = AC Line (ACL), Pin 3 = AC Neutral (ACN) |
| Output & Signal Terminal Pinout | DC Output Busbars: POS (+) and NEG (-); Control CN5 (24-Pin): Pins 1, 10, 15 = AUX (+5V/0.5A or +9V/0.3A); Pins 2, 4, 8, 12, 14, 16 = GND; Pin 3 = POK (Power OK); Pin 5 = PAR (Current Share); Pin 6 = VSET (Aux Voltage Select); Pin 7 = EN- (Inhibit -); Pin 9 = EN+ (Inhibit +); Pin 11 = ACI (I Program); Pin 13 = VCI (V Program); Pins 17, 18 = N.C.; Pin 19 = +5VC (Isolated Digital Supply); Pin 20 = GND1 (Isolated Digital GND); Pin 21 = SCL (I²C Clock); Pin 22 = SDA (I²C Data); Pin 23 = DA- (RS-485 -); Pin 24 = DA+ (RS-485 +) |
| Control & Monitoring Signals | Remote Enable (EN+/EN-, shipped with enable links fitted), Voltage Program (VCI: 0–5 VDC / 0–5 kΩ), Current Program (ACI: 0–5 VDC / 0–5 kΩ), Active Current Share (PAR: up to 8 units within 5%), Power OK (POK: open-drain, max. 20 mA sink, max. 40 V), Auxiliary Standby (5 VDC / 0.5 A or 9 VDC / 0.3 A) |
| Communication Interface | Digital I²C (SCL/SDA) and Differential RS-485 (DA+/DA-) with Dedicated Isolated +5VC/GND1 Reference |
| Status Indicator | Multi-State Diagnostic LED: Solid Green (Output OK), Solid Orange (Output OK Remote Mode), Slow Blink Green/Orange (Output Disabled), Fast Blink Red (OVP), Solid Red (OLP), Slow Blink Red (OTP), Intermittent Blink Red (Fan Fail), Short & Long Blink Red (AUX Standby Fail) |
| Terminal Tightening Torque | 1.27 Nm (13.0 kgf·cm) for M4 mounting and terminal screws |
| Overload Protection (OLP) Threshold | 105% of rated output power |
| Overload Protection (OLP) Mode | Constant current limiting |
| Overvoltage Protection (OVP) Threshold | Tracks programmed output voltage (114% to 120% at 100–105% Vout, ±7% tolerance) |
| Overvoltage Protection (OVP) Mode | Latch-off shutdown (Recycle AC input power to reset) |
| Overtemperature Protection (OTP) Mode | Internal thermal sensing; output shuts down and automatically recovers upon cooling |
| Short Circuit Protection (SCP) | Continuous protection with automatic recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC |
| Withstand Isolation Voltage (I/P to FG / Case) | 1500 VAC |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VAC |
| Earth Leakage Current | 1.0 mA max. (at 264 VAC / 60 Hz) |
| Operating Ambient Temperature Range | -20 °C to +60 °C (-4 °F to +140 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) |
| High-Temperature Derating Rate | Derate linearly at 5.0% per °C from 100% load at +50 °C to 50% load at +60 °C |
| Low-Line Input Derating | 100% load (3000 W / 12.0 A) across 180–264 VAC; derates linearly from 3000 W at 180 VAC to 2000 W (8.0 A) at 140 VAC; holds 2000 W (66.7% load) from 90 to 140 VAC |
| Operating Altitude | Up to 3000 m (9842 ft) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 20% to 90% RH (non-condensing) |
| Storage Relative Humidity | 10% to 95% RH (non-condensing) |
| Temperature Coefficient | ±0.02% / °C (from 0 °C to +50 °C) |
| Vibration Resistance | 2 g (10 to 500 Hz, 10 min/cycle, 60 min per axis across X, Y, Z axes per IEC 60068-2-16 and IEC 60068-2-64) |
| Safety Approvals (UL / North America) | UL 62368-1, CAN/CSA C22.2 No. 62368-1-14 |
| Safety Approvals (IEC / EN / TÜV) | CB Report IEC 62368-1:2014, TÜV EN 62368-1:2014/A11:2017 |
| Safety Approvals (Regional / Global) | CE Mark, UKCA |
| EMC Conducted & Radiated Emissions | EN 55032 Class A (Conducted and Radiated) |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker) |
| EMC Immunity Standards | EN 55024, EN 61000-4-2 (ESD Level 2/3: ±4 kV contact / ±8 kV air, Criteria A), EN 61000-4-3 (Radiated: 3 V/m, Criteria A), EN 61000-4-4 (EFT: ±1 kV, Criteria A), EN 61000-4-5 (Surge: Installation Class 3, Criteria A), EN 61000-4-6 (Conducted RF: 3 Vrms, Criteria A), Voltage Dips & Interruptions (>95% 10 ms Criteria A, >95% 5000 ms Criteria B) |
| MTBF (MIL-HDBK-217F) | 495,000 hours (at +25 °C Ground Benign) |
| Environmental Compliance | RoHS, REACH, 3-Year OEM Warranty |
Industrial Applications & Compatible Systems
Engineered for high-voltage DC power conversion and automated control, the XP Power HDL3000PS250 serves demanding OEM equipment and industrial MRO installations:
- EV Battery Simulation & Automated Test Equipment (ATE): Provides 0–262.5 VDC programmable voltage and 0–12.6 A current-limited profiles via I²C/RS-485 or 0–5 V analog signals for battery pack cyclers, burn-in racks, and component validation rigs.
- Industrial Laser & Specialist UV/IR LED Curing Systems: Powers high-voltage diode laser arrays, plasma excitation stages, and industrial LED heating/curing heads requiring tight ±1% regulation and constant-current overload protection.
- Electro-Plating, Anodizing & Cathodic Protection Rectifiers: Delivers continuous, programmable constant-current or constant-voltage DC excitation for electrochemical surface treatment baths and marine/pipeline corrosion prevention.
- High-Voltage Robotics & Factory Automation Drives: Supplies regulated 250 VDC bus power for multi-axis servo amplifiers, automated guided vehicle (AGV) fast-charging stations, and centralized industrial control cabinets.
Installation, Thermal Management & MRO Guidelines
Follow these engineering best practices when integrating the unit into high-power enclosures:
- Parallel Current Sharing & N+1 Redundancy Wiring: Up to 8 units can be connected in parallel via the PAR pin (Pin 5 on CN5) with built-in ORing diodes; calibrate individual no-load voltages within <0.2 VDC and limit total load to 90% of combined rated current.
- High-Line vs. Low-Line Input & Upstream Breaker Sizing: To extract the full 3000 W (12.0 A) rating, supply 180–264 VAC high-line power; when operating at 90–140 VAC, derate maximum load to 2000 W (8.0 A) and size D-curve breakers for the 19.7 A RMS current and 85 A cold-start inrush.
- Forced-Air Clearance & Fastener Penetration Limits: Maintain unobstructed clearance around the front/rear ventilation grilles for the variable-speed cooling fans, and ensure M4 mounting screws do not penetrate more than 3.0 mm (0.12 in) into the chassis at 1.27 Nm torque.
- Isolated Control Reference & Remote Enable Links: Always reference analog control signals (EN+, EN-, VCI, ACI, POK) to CN5 signal ground (GND) and digital I²C/RS-485 lines to isolated GND1 (Pin 20), never to the main high-voltage NEG (-) busbar.