Description
TDK-Lambda DPP120-24-3 (also known as DPP120243) is a rugged 120W three-phase DIN rail AC-DC power supply engineered for industrial automation and process control cabinets. Within TDK-Lambda’s DPP120–960 series nomenclature, “DPP” identifies the DIN rail industrial family, “120” denotes the 120W rated output capacity, “24” specifies the nominal 24VDC output rail (adjustable from 22.5V to 28.5V via front potentiometer), and “-3” designates a three-phase 340 to 575VAC input architecture (also supporting bi-phase operation with 75% load derating). Operating at a 70kHz switching frequency, this convection-cooled supply delivers 5A continuous output current with 89% typical conversion efficiency, tight -0% to +1% initial voltage accuracy, ±1% line/load regulation, and low 100mVp-p ripple and noise across a 20MHz bandwidth.
Comprehensive fault protection includes overcurrent limiting at 115% to 135% of rated load, overvoltage shutdown between 30V and 33V, and auto-recovering overtemperature protection, paired with a 0.3A normally open DC Good relay (closing above 17.6V to 19.4V) and bi-color diagnostic LEDs. Galvanic isolation is rated at 3kVAC input-to-output and 1.5kVAC input-to-ground, while wide-temperature components enable cold-start operation down to -40°C (-40°F) and full-load performance up to +61°C (+141.8°F) before linear derating to +71°C (+159.8°F). Housed in a compact 74.3mm-wide metal enclosure for tool-free TS35/7.5 or TS35/15 DIN rail mounting, the unit carries UL508 Listed, UL60950-1, EN60950-1, and CE certifications alongside EN55022 Class B EMI compliance.
Key Features
- Wide-Range 3-Phase AC Input: Accepts 340 to 575VAC (47–63Hz) across three phases with passive EN61000-3-2 harmonic compliance, plus bi-phase input capability when derated to 75% load.
- Precision 24VDC / 5A Regulated Output: Delivers 120W continuous output power adjustable from 22.5V to 28.5VDC with ±1% line and load regulation and 100mVp-p maximum ripple and noise.
- High 89% Conversion Efficiency & Low Inrush: Achieves 89% typical efficiency at 70kHz switching frequency while limiting typical cold-start inrush current to just 10A across 380–480VAC lines.
- Integrated DC Good Relay & Status LEDs: Includes a 0.3A normally open dry-contact DC Good relay closing above 17.6V–19.4V alongside green power-on and red low-output LEDs.
- Industrial Protection & 3kVAC Isolation: Safeguards downstream loads with 115–135% overcurrent protection, 30–33V overvoltage shutdown, auto-recovery thermal protection, and 3kVAC input-to-output dielectric isolation.
- Extreme -40°C to +71°C Thermal Envelope: Supports full 120W convection-cooled operation from -40°C to +61°C (-40°F to +141.8°F), derating linearly at 2.5%/°C up to +71°C (+159.8°F).
- UL508 Listed & EN55022 Class B Certified: Meets UL508 industrial control equipment standards, UL/EN60950-1 safety, IEC 60068-2-6 2G vibration, and EN55022 Class B conducted/radiated EMI.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | DPP120-24-3 |
| Alternate Part Number | DPP120243 |
| Product Series | DPP120 – 960 Series |
| Product Category | Three-Phase DIN Rail |
| Component Type | Three-Phase Industrial DIN Rail AC-DC Power Supply |
| Circuit Topology | Switched-Mode AC-DC Converter (70 kHz Fixed-Frequency, Passive PFC) |
| Nominal Output Voltage | 24 VDC |
| Output Voltage Adjustment Range | 22.5 VDC to 28.5 VDC (via front-panel potentiometer) |
| Output Voltage Initial Accuracy | -0%, +1% of Nominal Output Voltage |
| Rated Output Current | 5.0 A |
| Output Current Range | 0 A to 5.0 A |
| Rated Output Power | 120 W |
| Ripple and Noise (20 MHz Bandwidth) | 100 mVp-p max. |
| Line Regulation | ±1% |
| Load Regulation | ±1% |
| Hold-Up Time (at 380–480 VAC) | > 20 ms |
| Parallel Operation Capability | Not supported on 120W model (parallel droop mode available on DPP240/480/960 only) |
| AC Input Voltage Range | 340 VAC to 575 VAC, Three-Phase (Bi-phase permissible with 75% load derating) |
| Input Line Frequency | 47 Hz to 63 Hz |
| Conversion Efficiency (Typical) | 89% |
| AC Input Current (at 400 VAC, Typical) | 0.36 A |
| Inrush Current (Cold Start at 380–480 VAC, Typical) | 10 A |
| Power Factor (Typical) | 0.55 (Passive PFC, compliant with EN 61000-3-2) |
| Switching Frequency | 70 kHz |
| Overcurrent / Overload Protection (OCP / OLP) Threshold | 115% to 135% of rated output current (Typical) |
| Overcurrent / Overload Protection (OCP / OLP) Mode | Current limiting / foldback protection with automatic recovery upon fault removal |
| Overvoltage Protection (OVP) Threshold | 30 VDC to 33 VDC |
| Overvoltage Protection (OVP) Mode | Output shutdown; recycle AC input power to reset |
| Overtemperature Protection (OTP) Mode | Thermal shutdown with automatic recovery after cooling |
| Withstand Isolation Voltage (Input to Output) | 3 kVAC (3,000 VAC) for 1 minute |
| Withstand Isolation Voltage (Input to Ground / FG) | 1.5 kVAC (1,500 VAC) for 1 minute |
| Isolation Resistance (Output to Ground at 500 VDC) | > 100 MΩ (at 25 °C and 70% RH) |
| Operating Ambient Temperature Range | -40 °C to +71 °C (-40 °F to +159.8 °F) |
| Full-Load Operating Temperature Limit | +61 °C (+141.8 °F) at 100% rated load (120 W) |
| High-Temperature Derating Rate | Linear derating at 2.5% / °C from +61 °C to +71 °C (+141.8 °F to +159.8 °F) |
| Two-Phase (Bi-Phase) Input Derating | Derate maximum output load to 75% (90 W) when operated on two phases |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Humidity Range | 20% to 95% RH (non-condensing) |
| Sinusoidal Vibration Resistance | IEC 60068-2-6: 10 Hz to 500 Hz, 2G acceleration along X, Y, and Z axes |
| Mechanical Shock Resistance | IEC 60068-2-27: Half-sine wave, 4G peak, 22 ms duration, 3 shocks per face |
| MTBF (Bellcore / Telcordia Issue 6 at 40 °C, Ground Benign) | 527,000 Hours |
| North American Safety Approvals | UL 508 Listed (Industrial Control Equipment), UL 60950-1 |
| European & International Safety Approvals | EN 60950-1, CE Marked |
| Conducted & Radiated EMI Emissions | EN 55022 Class B |
| Harmonic Current Emissions | EN 61000-3-2 Compliant (Passive PFC) |
| Electrostatic Discharge (ESD) Immunity | IEC 61000-4-2 Compliant |
| Radiated RF Electromagnetic Field Immunity | IEC 61000-4-3 Compliant |
| Electrical Fast Transient (EFT / Burst) Immunity | IEC 61000-4-4 Compliant |
| Surge Immunity | IEC 61000-4-5 Compliant |
| Conducted RF Disturbances Immunity | IEC 61000-4-6 Compliant |
| Power Frequency Magnetic Field Immunity | IEC 61000-4-8 Compliant |
| Voltage Dips & Short Interruptions Immunity | IEC 61000-4-11 Compliant |
| DC Good Relay Contact Rating | 0.3 A Rated Normally Open (NO) Relay Contacts (24V models only) |
| DC Good Relay Switching Threshold | Contacts close when DC output voltage is above 17.6 VDC to 19.4 VDC |
| Front-Panel Diagnostic LED Indicators | Green LED = DC Output On; Red LED = DC Output Low |
| Input Terminal Configuration | Screw Terminal Block: L1, L2, L3, FG (Protective Earth) |
| Output & Signal Terminal Configuration | Screw Terminal Block: +V, +V, -V, -V, and DC Good Relay Contacts (2-pin) |
| Cooling Method | Natural Free-Air Convection (Fanless) |
| Mounting Style | Tool-Free Snap-On Mounting for TS35/7.5 or TS35/15 DIN Rail |
| Recommended Installation Clearance | 25 mm (0.98 in) minimum free-air clearance on all sides |
| Overall Width (W) | 74.3 mm (2.92 in) |
| Overall Height (H) | 124.0 mm (4.88 in) |
| Overall Depth (D) | 111.9 mm (4.41 in) |
| Overall Dimensions (W × H × D) | 74.3 × 124.0 × 111.9 mm (2.92 × 4.88 × 4.41 in) |
| Net Weight (Typical) | 800 g (0.80 kg / 1.76 lbs / 28.22 oz) |
| Enclosure / Case Material | Rugged Metal Housing |
| Manufacturer Warranty | 3 Years |
Industrial Applications & Compatible Systems
TDK-Lambda DPP120-24-3 provides direct 380–480VAC three-phase to 24VDC auxiliary control power inside heavy industrial electrical cabinets without requiring a step-down control transformer:
- UL508A Motor Control Centers (MCCs) & VFD Panels: Supplies 24VDC control power directly from 400VAC or 480VAC three-phase main busbars for contactor coils, safety relays, and drive logic boards.
- Factory Automation & PLC / Distributed I/O Racks: Powers programmable logic controllers, remote fieldbus couplers, proximity sensors, and solenoid valve manifolds in automotive assembly lines.
- Chemical Processing & Continuous Process Control: Delivers 89% efficient, fanless 24VDC power with dry-contact DC Good health monitoring for SCADA telemetry, transmitters, and alarm annunciators.
- Burn-In Systems, Test Benches & Industrial Instrumentation: Provides low-ripple 24VDC bias power with wide -40°C cold-start capability for automated test equipment and outdoor utility enclosures.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: Mount the DPP120-24-3 vertically onto a standard TS35/7.5 or TS35/15 DIN rail and maintain at least 25mm (0.98 in) of unobstructed clearance on all sides to ensure proper natural convection cooling. For ambient temperatures between +61°C (+141.8°F) and +71°C (+159.8°F), linearly derate the maximum continuous load at 2.5%/°C; if operating from a bi-phase (two-phase) AC input instead of balanced three-phase lines, cap continuous output loading at 75% (90W). Protect upstream L1/L2/L3 input phases with a 3-pole thermal-magnetic circuit breaker or industrial time-delay fuses rated for 480VAC/600VAC operation.