S8VK-G03005-400 Omron 25W 5VDC 5A DIN Rail Power Supply

$139.15

Omron S8VK-G03005-400 (S8VKG03005400) 25W 5VDC 5A coated DIN rail power supply, 85-264VAC/90-350VDC input, featuring 6A power boost, UL 508 & Class 2.

SKU: S8VK-G03005-400 Category: Brand:

Description

Omron S8VK-G03005-400 (also known as S8VKG03005400) is an industrial single-phase DIN rail switch-mode power supply from the compact S8VK-G Series. Built on the 30W mechanical frame (`030`), its model nomenclature specifies a single-phase input (`G`), a regulated 5 VDC nominal output (`05`) delivering 5 A rated continuous current (25 W), and factory-applied conformal PCB coating (`-400`) for enhanced resistance against humidity, dust, and corrosive industrial atmospheres. It accepts a universal 85 to 264 VAC (47 to 450 Hz) or 90 to 350 VDC input, provides a 120% Power Boost function (6 A / 30 W for up to 10 seconds) to handle transient startup loads, and achieves 79% typical efficiency with ultra-low output ripple and noise of 30 mVp-p maximum.

Housed in a space-saving 32 x 90 x 90 mm (1.26 x 3.54 x 3.54 in) IP20 enclosure weighing 195 g (6.88 oz) max., the unit snaps directly onto standard TS-35 DIN rails and supports front or side bracket mounting. Front-accessible M3.5 screw terminals accommodate input, protective earth, and dual-pole DC output wiring alongside a green DC ON LED and a -10% to +15% (4.5 to 5.75 VDC) output voltage adjuster. Comprehensive protection includes automatic-recovery overload limiting above 121%, latch-off overvoltage protection at 130% or higher, and 3.0 kVAC input-to-output galvanic isolation. Engineered for harsh environments from -40 °C to +70 °C (-40 °F to +158 °F), it holds UL 508 Listed, UL 1310 Class 2, UL/EN 62368-1, EN 61558-2-16, Lloyd’s Register, and SEMI F47-0706 approvals.

Key Features

  • Conformal Coated 5VDC Output & 120% Power Boost: Delivers 5 VDC at 5 A continuous (25 W) and 6 A boost current (30 W for 10 s) with factory conformal coating (-400 suffix) for harsh cabinet environments.
  • Wide Universal AC/DC & Two-Phase Input: Operates seamlessly from 85 to 264 VAC (47 to 450 Hz), 90 to 350 VDC, or two phases of a 240 VAC three-phase system for global machinery standardization.
  • Tight Regulation & Low 30 mVp-p Ripple: Maintains 0.4% max. line regulation and 0.8% max. load regulation with 30 mVp-p max. ripple and noise (20 MHz bandwidth) to protect sensitive 5V logic controllers.
  • Extended -40°C to +70°C Thermal Window: Supports cold startup down to -40 °C (-40 °F) and full-load convection operation up to +55 °C (+131 °F) in standard vertical mounting with a 10-year minimum design life.
  • Series, Parallel & Redundant Operation Ready: Floating secondary output permits 2-unit series wiring for higher or split +/- voltages, 2-unit parallel current sharing (-25 to +40 °C), and N+1 backup with S8VK-R.
  • Robust 3.0 kVAC Isolation & Comprehensive Protections: Provides 3.0 kVAC primary-to-secondary dielectric strength, intermittent auto-reset overload protection (>121%), and latch-off overvoltage shutdown (>=130%) with an internal 250 VAC 4.0 A HBC fuse.
  • UL Class 2, Marine & Semiconductor Certifications: Certified to UL 508 Listed, UL 1310 Class 2 output, UL/EN 62368-1, EN 50178, EN 60204-1 PELV, Lloyd’s Register marine standards, and SEMI F47-0706 sag immunity.

Technical Specifications

Manufacturer Omron
Manufacturer Part Number (MPN) S8VK-G03005-400
Alternate Part Number S8VKG03005400
OEM Cross-Reference / Replaced Part S8VK-G03005 (Standard uncoated base model)
Compatible Equipment / Series Omron S8V-NF Noise Filter, S8V-CP DC Electronic Circuit Protector, S8VK-R Redundancy Unit, S82Y-VS10F / S82Y-VS10S Mounting Brackets
Product Series S8VK-G Series (30W Frame Class with -400 Conformal Coating Option)
Product Category Single-Phase DIN Rail
Component Type Industrial Single-Phase AC-DC DIN Rail Switch-Mode Power Supply (Conformal Coated)
Circuit Topology Isolated Switch-Mode Power Supply (SMPS) with Photocoupler Feedback
Nominal Output Voltage 5 VDC
Output Voltage Adjustment Range 4.5 to 5.75 VDC (-10% to +15% guaranteed via front V.ADJ potentiometer)
Rated Output Current 5 A
Output Current Range 0 to 5 A continuous
Peak / Surge Output Current 6 A (120% Power Boost function for up to 10 s max., max. 30% duty cycle, average current <= 5 A)
Rated Output Power 25 W continuous (30 W frame class)
Peak Output Power 30 W (at 6 A Power Boost)
Number of Outputs 1 (Single Output with dual +V and dual -V terminal poles)
Output Ripple & Noise (Max.) 30 mVp-p max. (at 20 MHz bandwidth, 100 to 240 VAC input, 100% load, -25 to +70 °C)
Line Regulation 0.4% max. (Input variation influence across allowable input voltage range at rated output)
Load Regulation 0.8% max. (Load variation influence from 0 A to rated output current at 100 to 240 VAC)
Setup Time (at 115 VAC) 550 ms typ. (Startup time to 90% output voltage, cold start at 25 °C, rated load)
Setup Time (at 230 VAC) 430 ms typ. (Startup time to 90% output voltage, cold start at 25 °C, rated load)
Hold-Up Time (at 115 VAC) 33 ms typ. (at 25 °C, rated output voltage and current)
Hold-Up Time (at 230 VAC) 177 ms typ. (at 25 °C, rated output voltage and current)
AC Input Voltage Range 85 to 264 VAC (Single-phase or 2-phase input up to 240 VAC +10%)
DC Input Voltage Range 90 to 350 VDC (Requires external 350 VDC min., 4 A safety fuse on DC input)
Nominal Input Voltage 100 to 240 VAC
Input Frequency Range 47 to 450 Hz (Nominal 50/60 Hz)
Efficiency (at 230 VAC) 79% typ. (at rated 5 VDC / 5 A load)
AC Input Current (at 115 VAC) 0.5 A typ. (at rated load)
AC Input Current (at 230 VAC) 0.32 A typ. (at rated load)
Inrush Current (Cold Start at 115 VAC) 16 A typ. (at 25 °C cold start)
Inrush Current (Cold Start at 230 VAC) 32 A typ. (at 25 °C cold start)
Power Factor (PF at 230 VAC) 0.43 min. (at 100% load)
Mounting Style DIN Rail TS-35 (PFP-100N / PFP-50N / PFP-100N2); optional Front/Side chassis mounting via S82Y-VS10F or S82Y-VS10S
Cooling Method Natural air convection (Fanless)
Overall Width (W) 32 mm (1.26 in)
Overall Height (H) 90 mm (3.54 in)
Overall Depth (D) 90 mm (3.54 in) excluding 5 mm terminal projection and 4.7 mm rail stopper
Dimensional Tolerance ±1 mm (±0.039 in) on overall W, H, D dimensions
Net Weight 195 g max. (0.43 lbs / 6.88 oz)
Termination / Connector Style Screw terminal block (7.62 mm pitch, 2.7 x 2.9 mm wire insertion hole, #1 Phillips / 3.5 mm max. blade driver)
Input Terminal Pinout Bottom Terminal Block: Input (L), Input (N), Protective Earth (PE); internal 250 VAC 4.0 A HBC fuse on (L) side
Output & Signal Terminal Pinout Top Terminal Block: DC Output (-V, -V, +V, +V)
Status Indicator Green LED (DC ON), illuminates at 80% to 90% or more of rated voltage; flashes during overload protection
Terminal Wire Gauge Range Input: AWG 24 to 12 (0.25 to 4 mm² solid / 0.25 to 2.5 mm² stranded); Output: AWG 18 to 12 (0.75 to 4 mm² solid / 0.75 to 2.5 mm² stranded); PE: AWG 14 to 12 (2.5 to 4 mm²); Stripping length: 8 to 10 mm
Terminal Tightening Torque 0.5 to 0.6 N·m (4.43 to 5.31 lb-in); max. terminal block force 75 N
Enclosure / Potting Material Conformal coated internal PCB assembly (-400 suffix) in ventilated industrial housing
Overload Protection (OLP) Threshold Above 121% of rated output current (> 6.05 A)
Overload Protection (OLP) Mode Intermittent operation with automatic reset when output current returns within rated range
Overvoltage Protection (OVP) Threshold 130% or higher of rated output voltage (approx. >= 6.5 VDC)
Overvoltage Protection (OVP) Mode Output shut off; manual reset by turning off AC input power for at least 3 minutes and re-applying
Short Circuit Protection (SCP) Protected via intermittent current limiting with automatic recovery
Withstand Isolation Voltage (I/P to O/P) 3.0 kVAC for 1 min (cutoff current 20 mA)
Withstand Isolation Voltage (I/P to FG / Case) 2.0 kVAC for 1 min (between all input terminals and PE, cutoff current 20 mA)
Withstand Isolation Voltage (O/P to FG / Case) 1.0 kVAC for 1 min (between all output terminals and PE, cutoff current 20 mA)
Isolation Resistance (at 500 VDC) 100 MΩ min. (between all output terminals and all input/PE terminals)
Earth Leakage Current 0.13 mA typ. (at 115 VAC) / 0.24 mA typ. (at 230 VAC)
Operating Ambient Temperature Range -40 °C to +70 °C (-40 °F to +158 °F) with no condensation or icing
Full-Load Operating Temperature Limit +55 °C (+131 °F) in standard vertical mounting; +40 °C (+104 °F) in face-up mounting
High-Temperature Derating Rate Standard vertical mounting: 2.5%/°C from +55 °C to +70 °C (62.5% load at 70 °C); Face-up mounting: 2.5%/°C from +40 °C to +60 °C (50% load at 60 °C)
Low-Line Input Derating 2.5%/V below 90 VAC input; multiply derating curve load by 0.9x coefficient when operating from DC power input
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F) with no condensation or icing
Operating Relative Humidity 0% to 95% RH (non-condensing)
Storage Relative Humidity 0% to 95% RH (non-condensing)
Temperature Coefficient 0.05%/°C max. (115 to 230 VAC input)
Vibration Resistance 10 to 55 Hz, 0.375 mm half-amplitude for 2 hours each in X, Y, and Z directions; Shock resistance: 150 m/s² (3 times each in ±X, ±Y, ±Z)
Ingress Protection (IP) IP20 (per EN/IEC 60529)
Safety Approvals (UL / North America) UL 508 Listed, UL 1310 Class 2 Output, UL 62368-1 Recognized (UR), cUL CSA C22.2 No. 107.1 (Class 2 per CSA C22.2 No. 223), cUR CSA C22.2 No. 62368-1
Safety Approvals (IEC / EN / TÜV) EN 50178, EN 62368-1, EN 60204-1 PELV, EN 61558-2-16 (Safety of Power Transformers)
Safety Approvals (Regional / Global) Lloyd’s Register Marine Standard, SEMI F47-0706 (200 to 240 VAC), EAC (TR CU 004/2011, TR CU 020/2011), RCM (EN 61000-6-4)
EMC Conducted & Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B (Conducted & Radiated)
EMC Harmonic & Flicker Compliance Conforms to EN 61000-3-2 (Harmonic Current Emissions)
EMC Immunity Standards Conforms to EN 61204-3 High Severity Levels (EMS), SEMI F47-0706 Voltage Sag Immunity (at 200 to 240 VAC)
MTBF (MIL-HDBK-217F) 135,000 hours min. (580,000 hours reference MTBF value; 10 years min. expected service life at 40 °C, 50% load)

Industrial Applications & Compatible Systems

The Omron S8VK-G03005-400 is purpose-built for 5 VDC industrial electronics requiring high reliability and environmental protection against moisture or airborne contaminants:

  • 5V Logic Controllers, Single-Board Computers & Gateways: Supplies tightly regulated 5 VDC (up to 5 A continuous, 6 A boost) with UL 1310 Class 2 safety compliance for embedded industrial PCs, IIoT edge gateways, barcode readers, and TTL/CMOS logic boards.
  • Harsh & Humid Industrial Control Cabinets: The `-400` conformal PCB coating shields internal circuitry against high humidity (up to 95% RH), fine dust, and mild chemical vapors in food and beverage, water treatment, and outdoor kiosk enclosures.
  • Semiconductor Processing & Automated Inspection Tools: Meets SEMI F47-0706 voltage sag immunity requirements (200 to 240 VAC) and Class B EMI limits to prevent nuisance resets on wafer handling and vision inspection systems.
  • Marine Vessel & Shipboard Bridge Instrumentation: Certified to Lloyd’s Register marine standards (when paired with a Schaffner FN2080-10-06 input noise filter and TDK ZCAT2035-0930 clamp filter) for shipboard automation panels.

Installation, Thermal Management & MRO Guidelines

Follow these OEM engineering guidelines during installation and preventive maintenance to maximize power supply service life:

  • Convection Clearance & Orientation Derating: Maintain at least 20 mm vertical clearance above and below the unit for natural air convection; derate output load linearly by 2.5%/°C above +55 °C in standard vertical mounting or above +40 °C in face-up mounting.
  • DC Input & Two-Phase External Fusing: Because the internal 250 VAC 4.0 A HBC fuse is located strictly on the (L) terminal, install an external fuse or breaker on the (N) line for two-phase AC applications, or a 350 VDC min., 4 A external fuse when operating from a 90 to 350 VDC bus.
  • Parallel, Series & Marine Mounting Precautions: When paralleling two units (-25 °C to +40 °C), match output voltages within 50 mV and use equal wire lengths or an S8VK-R redundancy module; for high-vibration or marine installations, use a steel DIN rail with PFP-M end plates on both sides.