HLG-480H-C2100A Mean Well 481W 2100mA LED Driver

$143.12

Mean Well HLG-480H-C2100A (HLG480HC2100A) 481W 2100mA constant current LED driver, 90-305VAC input, 114-229VDC output, IP65 chassis, Io pot & UL8750 Type HL.

SKU: HLG-480H-C2100A Category: Brand:

Description

Mean Well HLG-480H-C2100A (also known as HLG480HC2100A) is an industrial-grade 481W constant current LED driver from the HLG-480H-C series engineered for high-voltage outdoor and harsh-environment solid-state lighting. Decoding its OEM nomenclature, the 480H denotes a 480W-class high-input-voltage architecture operating across 90 to 305 VAC (127 to 431 VDC), C2100 specifies a 2100 mA rated constant current output across a 114 to 229 VDC compliance voltage region (280 V max open-circuit voltage), and the A-Type suffix designates an IP65-rated enclosure with an integrated potentiometer for on-chassis current adjustment from 1050 to 2100 mA. Utilizing an interleaved active PFC stage (45 kHz) and PWM switching topology (55 kHz), this unit achieves 95% typical efficiency, power factor up to 0.98 at 115 VAC, and total harmonic distortion below 20%. It also integrates Mean Well’s innovative Environment-Adaptive function, which temporarily boosts output voltage up to 120% Vo at 80% Io during cold ignition before settling into steady-state regulation with 5.0% maximum current ripple.

Housed in a ruggedized Case No. 251 corrosion-resistant aluminum enclosure measuring 262 mm (10.31 in) in length, 125 mm (4.92 in) in width, and 43.8 mm (1.72 in) in height, the fanless design dissipates heat via free air convection across a -40 °C to +90 °C (-40 °F to +194 °F) case temperature range. Field wiring is simplified via pre-stripped 300 ± 20 mm (11.81 ± 0.79 in) weatherproof 17 AWG rubber-jacketed input and output flying leads. Comprehensive fault protection includes auto-recovering constant-current short-circuit protection (SCP) alongside latch-off overvoltage protection (289 to 322 V) and overtemperature protection (OTP) that reset upon AC power cycling. Engineered for global infrastructure deployment, the driver provides 3.75 kVAC input-to-output galvanic isolation, 4 kV line-to-earth / 2 kV line-to-line surge immunity, and full UL 8750 Type HL (Class I, Division 2 hazardous locations) and ENEC EN 61347-2-13 safety certifications.

Key Features

  • High-Voltage Constant Current Output: Delivers a regulated 2100 mA constant current across a wide 114 to 229 VDC compliance window (481 W rated power, 280 V max open-circuit voltage) with ±5% tolerance and 5.0% max ripple.
  • On-Chassis Current Adjustment (A-Type): Features a sealed internal potentiometer accessible via an IP65 weatherproof plug, allowing field technicians to fine-tune output current between 1050 mA (50%) and 2100 mA (100%).
  • Environment-Adaptive Cold Ignition: Automatically detects high forward-voltage LED string impedance in freezing environments, temporarily boosting output up to 120% Vo at 80% Io until the luminaire warms into steady-state operation.
  • Wide 90-305 VAC Universal & 277 VAC Input: Operates across 90 to 305 VAC (47 to 63 Hz) or 127 to 431 VDC with built-in active PFC (PF >= 0.98 at 115 VAC, >= 0.95 at 277 VAC) and THD below 20%.
  • 95% Peak Efficiency & Fanless Thermal Design: Eliminates failure-prone cooling fans while sustaining 100% full-load output up to +75 °C (+167 °F) case temperature (+60 °C ambient at 230 VAC) with >62,000-hour rated service life.
  • Industrial Surge & Fault Protection Suite: Integrates 4 kV common-mode (Line-Earth) and 2 kV differential-mode (Line-Line) surge immunity, continuous short-circuit current limiting, and latch-off overvoltage (289-322 V) and overtemperature shutdown.
  • UL 8750 Type HL & Global Lighting Approvals: Certified to UL 8750 Type HL for Class I, Division 2 hazardous locations, CSA C22.2 No. 250.13-12, ENEC EN 61347-2-13, EN 62384, and EN 55015 EMI compliance.

Technical Specifications

Manufacturer Mean Well
Manufacturer Part Number (MPN) HLG-480H-C2100A
Alternate Part Number HLG480HC2100A
Product Series HLG-480H-C Series
Product Category Constant Current Drivers
Component Type Enclosed Outdoor Constant Current LED Driver
Circuit Topology Two-Stage Active PFC (45 kHz) + Isolated PWM Switching (55 kHz)
LED Operation Mode Constant Current (CC) with Environment-Adaptive Cold-Start Boost (up to 120% Vo at 80% Io)
Constant Current Region Voltage Range 114 to 229 VDC
Max. Open Circuit Voltage 280 VDC
Rated Output Current 2100 mA (2.1 A)
Current Adjustment Range 1050 to 2100 mA (Adjustable via built-in potentiometer, A-Type)
Rated Output Power 481 W
Output Ripple & Noise (Max.) 5.0% max. Current Ripple (at rated current)
Output Current Tolerance ±5.0%
Setup Time 500 ms (at 115 / 230 VAC cold start)
AC Input Voltage Range 90 to 305 VAC (180 to 305 VAC for 100% full load)
DC Input Voltage Range 127 to 431 VDC
Input Frequency Range 47 to 63 Hz
Efficiency 95.0% typ. (at 230 VAC full load)
AC Input Current (at 115 VAC) 5.0 A typ.
AC Input Current (at 230 VAC) 2.45 A typ. (2.0 A typ. at 277 VAC)
Inrush Current (Cold Start at 230 VAC) 35 A (twidth = 1800 µs measured at 50% Ipeak per NEMA 410)
Max. Units per 16A Circuit Breaker 2 units (Type B MCB) / 3 units (Type C MCB) at 230 VAC
Power Factor (PF at 115 VAC) >= 0.98 (at full load)
Power Factor (PF at 230 VAC) >= 0.97 at 230 VAC / >= 0.95 at 277 VAC (at full load)
Power Factor Correction (PFC) Built-in Active PFC (THD = 40% load across 115 / 230 / 277 VAC)
Switching Frequency PFC: 45 kHz; PWM: 55 kHz
Mounting Style Chassis / Surface Mount (4 x Ø4.5 mm mounting slots)
Cooling Method Free Air Convection (Fanless)
Enclosure Case Number 251
Overall Width (W) 125.0 mm (4.92 in)
Overall Height (H) 43.8 mm (1.72 in)
Overall Depth (D) 262.0 mm (10.31 in)
Dimensional Tolerance ±1.0 mm (±0.04 in)
Mounting Hole Pitch 235.2 x 113.8 mm (9.26 x 4.48 in) center-to-center
Net Weight 2.80 kg (6.17 lbs)
Termination / Connector Style Pre-Wired Weatherproof Rubber Flying Leads
Input Terminal Pinout 3-Core Cable (SJOW 17 AWG x 3C & H05RN-F 3 x 1.0 mm²): AC/L (Brown), AC/N (Blue), FG (Green/Yellow)
Output & Signal Terminal Pinout 2-Core Cable (SOOW 17 AWG x 2C & H07RN-F 2 x 1.0 mm²): Vo+ (Brown), Vo- (Blue)
Lead Wire Length Input & Output Leads: 300 ± 20 mm (11.81 ± 0.79 in)
Enclosure / Potting Material Extruded Aluminum Metal Housing (Class I Design) with Internal Thermal Potting
Overvoltage Protection (OVP) Threshold 289 to 322 VDC
Overvoltage Protection (OVP) Mode Shut down output voltage, re-power on to recover (Latch-Off)
Overtemperature Protection (OTP) Mode Shut down output voltage, re-power on to recover (Latch-Off)
Short Circuit Protection (SCP) Constant current limiting, recovers automatically after fault condition is removed
Withstand Isolation Voltage (I/P to O/P) 3.75 kVAC (3750 VAC)
Withstand Isolation Voltage (I/P to FG / Case) 2.0 kVAC (2000 VAC)
Withstand Isolation Voltage (O/P to FG / Case) 1.5 kVAC (1500 VAC)
Isolation Resistance (at 500 VDC) 100 MΩ min. (I/P-O/P, I/P-FG, O/P-FG at 25 °C / 70% RH)
Earth Leakage Current < 0.75 mA (at 277 VAC)
Operating Case Temperature Range (Tcase) -40 °C to +90 °C (-40 °F to +194 °F)
Operating Ambient Temperature Range -40 °C to +70 °C (-40 °F to +158 °F) horizontal with derating
Full-Load Operating Temperature Limit Tcase up to +75 °C (+167 °F) / Ambient Ta up to +60 °C (+140 °F) at >= 230 VAC (+50 °C at 110 VAC)
High-Temperature Derating Rate Linearly derate load from 100% at Tcase +75 °C to 50% at Tcase +90 °C (or 100% at Ta +60 °C to 60% at Ta +70 °C)
Low-Line Input Derating Linearly derate from 100% load at 180 VAC to 80% at 110 VAC and 50% at 90 VAC
Altitude Derating 3.5 °C per 1000 m (3280 ft) for operating altitudes above 2000 m (6560 ft)
Storage Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Operating Relative Humidity 20% to 95% RH (non-condensing)
Storage Relative Humidity 10% to 95% RH (non-condensing)
Temperature Coefficient ±0.02% / °C (0 °C to +60 °C)
Vibration Resistance 10 to 500 Hz, 5G (12 min/cycle, 72 min per X, Y, Z axis)
Ingress Protection (IP) IP65 (Dust-tight and protected against water jets)
Safety Approvals (UL / North America) UL 8750 Type HL (Class I, Division 2 Hazardous Locations), CSA C22.2 No. 250.13-12
Safety Approvals (IEC / EN / TÜV) ENEC BS EN/EN 61347-1, BS EN/EN 61347-2-13 Independent, BS EN/EN 62384
Safety Approvals (Regional / Global) AS/NZS IEC 61347.2.13:2013, AS/NZS 61347.1:2016, GB/T 19510.1, GB/T 19510.213, EAC TP TC 004
EMC Conducted & Radiated Emissions Compliance to BS EN/EN 55015, GB/T 17743, EAC TP TC 020
EMC Harmonic & Flicker Compliance BS EN/EN 61000-3-2 Class C (at >= 50% load), BS EN/EN 61000-3-3, GB 17625.1
EMC Immunity Standards BS EN/EN 61547, BS EN/EN 61000-4-2, -3, -4, -5 (Surge: 4 kV Line-Earth / 2 kV Line-Line), -6, -8, -11 (Light Industry Level)
MTBF (Telcordia SR-332 / Bellcore) 1,350,900 hours min. (at 25 °C)
MTBF (MIL-HDBK-217F) 110,500 hours min. (at 25 °C)
Typical Service Lifetime & Warranty >62,000 hours (at Tcase <= 75 °C) / 7-Year Manufacturer Warranty

Industrial Applications & Compatible Systems

Engineered for high-power solid-state luminaires, the Mean Well HLG-480H-C2100A provides rugged constant-current regulation across demanding industrial and outdoor lighting installations:

  • High-Mast Stadium & Arena Floodlighting: Drives high-voltage series LED arrays requiring 2100 mA between 114 V and 229 V with low current ripple (=0.95 at 277 VAC).
  • Marine Port, Container Terminal & Harbor Cranes: Withstands salt-air moisture, 5G mechanical crane vibration, and 4 kV common-mode lightning surges via its potted IP65 aluminum chassis.
  • Commercial Horticultural & Greenhouse Grow Lights: Allows facility engineers to trim photosynthetic photon flux density (PPFD) across 1050 to 2100 mA using the onboard Io potentiometer.
  • Mining & Class I Division 2 Hazardous Locations: Carries UL 8750 Type HL recognition for integration into hazardous-location luminaires deployed in petrochemical, grain, and mining facilities.

Installation, Thermal Management & MRO Guidelines

To maximize driver longevity and ensure nuisance-free branch circuit operation, observe these critical engineering and installation guidelines:

  • Low-Line AC Voltage Derating: While the driver delivers 100% power (481 W) across 180 to 305 VAC, installations operating on 115 VAC nominal mains must derate output load to 80% at 110 VAC (and 50% at 90 VAC) per the static characteristic curve.
  • Thermal Management & Case Temperature Point (tc): Monitor the designated case hotspot (78 mm from the input edge); keep Tcase at or below +75 °C (+167 °F) to preserve full-load capability and achieve the rated >62,000-hour operational lifetime.
  • Upstream MCB Inrush Sizing: Account for the 35 A (1800 µs pulse width) cold-start inrush current at 230 VAC by limiting branch circuits to a maximum of 2 drivers per 16 A Type B breaker or 3 drivers per 16 A Type C breaker.
  • Weatherproof Cable Gland & Stopper Sealing: After adjusting the internal current potentiometer, firmly reseat the rubber access stopper and use IP67/IP68-rated waterproof junction boxes on the 17 AWG SJOW/SOOW flying leads to prevent moisture ingress.