Description
Cosel PBA30F-5-N (also known as PBA30F5N) is a compact 30W single-output chassis-mount AC-DC switching power supply from the industrial PBA series, where the -5 suffix specifies a regulated 5VDC / 6A output and the -N option designates the factory-installed protective metal cover. Engineered with an active power factor correction (PFC) front-end stage and high-frequency flyback conversion topology, it accepts a universal 85 to 264 VAC single-phase input (or 120 to 370 VDC) while maintaining a power factor of 0.98 typical at 100 VAC. The unit delivers tight line regulation within 20 mV, load regulation within 40 mV, low output ripple and noise capped at 80 mVp-p maximum across 0 to +70 °C, and a front-accessible potentiometer allowing voltage trimming from 4.50 to 5.50 VDC.
Housed in a rugged galvanized steel chassis enclosure measuring 39 × 78 × 103 mm (1.54 × 3.07 × 4.06 in) and weighing 230 g (8.11 oz), the PBA30F-5-N relies on silent natural convection cooling and features an accessible 5-position M3 screw terminal block. Built-in protection circuits include automatic-recovery overcurrent/short-circuit protection starting above 105% rated load and latching overvoltage protection triggered between 5.75 and 7.0 VDC, backed by 3,000 VAC input-to-output reinforced galvanic isolation. Certified to UL 62368-1, CSA C22.2 No. 62368-1, EN 62368-1, and DENAN standards alongside CISPR32/EN55032 Class B emissions compliance, it operates reliably from -10 to +70 °C (14 to 158 °F) with full 30W output up to +40 °C under standard horizontal chassis mounting.
Key Features
- Regulated 5VDC 6A Output with Trim Adjustment: Delivers 30W continuous output power with tight 20 mV line regulation, 40 mV load regulation, and an onboard potentiometer adjustable from 4.50 to 5.50 VDC.
- Universal AC/DC Input & Active PFC Stage: Operates across 85 to 264 VAC (47–63 Hz) or 120 to 370 VDC with built-in active power factor correction achieving 0.98 typical PF and IEC 61000-3-2 Class A compliance.
- Factory-Installed Protective Metal Cover (-N Option): Fully enclosed galvanized steel chassis measuring 39 × 78 × 103 mm shields internal high-voltage circuitry from accidental contact and debris in industrial cabinets.
- Comprehensive Fault Protection Suite: Integrates auto-recovery overcurrent and short-circuit protection above 105% rated current alongside latching overvoltage shutdown between 5.75 and 7.0 VDC (115–140% nominal).
- 3,000 VAC Reinforced Isolation & Low Leakage: Provides 3,000 VAC input-to-output and 2,000 VAC input-to-ground dielectric withstand voltage with earth leakage current strictly below 0.75 mA at 240 VAC.
- Global Industrial Safety & Class B EMC Compliance: Certified to UL 62368-1, C-UL, EN 62368-1, and DENAN, meeting FCC-B, CISPR32-B, EN 55032-B, and VCCI-B conducted and radiated emission limits without external filters.
- Fanless Convection Cooling & High Vibration Tolerance: Operates silently without cooling fans across -10 to +70 °C (14 to 158 °F) and withstands 2G (19.6 m/s²) vibration and 20G mechanical shock.
Technical Specifications
| Manufacturer | Cosel |
|---|---|
| Manufacturer Part Number (MPN) | PBA30F-5-N |
| Alternate Part Number | PBA30F5N |
| Product Series | PBA Series (PBA30F) |
| Product Category | Chassis Power Supplies |
| Component Type | Enclosed AC-DC Switching Power Supply (with Metal Cover) |
| Circuit Topology | Active PFC + High-Frequency Flyback Switching |
| Nominal Output Voltage | 5 VDC |
| Output Voltage Adjustment Range | 4.50 to 5.50 VDC (via built-in potentiometer V.ADJ) |
| Rated Output Current | 6 A |
| Output Current Range | 0 to 6 A |
| Rated Output Power | 30 W |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 80 mVp-p (0 to +70 °C); 120 mVp-p (-10 to 0 °C) at 20 MHz BW |
| Output Voltage Tolerance | ±1.0% (factory set at 100/200 VAC, full load, 25 °C) |
| Line Regulation | 20 mV max. (across 85 to 264 VAC input) |
| Load Regulation | 40 mV max. (0 to 100% load change) |
| Setup Time (at 115 VAC) | 300 ms typ. (at 100 VAC, 100% load) |
| Setup Time (at 230 VAC) | 200 ms typ. (at 200 VAC, 100% load) |
| Hold-Up Time (at 115 VAC) | 20 ms typ. (at 100 VAC, 100% load) |
| Hold-Up Time (at 230 VAC) | 20 ms typ. (at 200 VAC, 100% load) |
| AC Input Voltage Range | 85 to 264 VAC (Single-Phase) |
| DC Input Voltage Range | 120 to 370 VDC |
| Nominal Input Voltage | 100 to 240 VAC |
| Input Frequency Range | 47 to 63 Hz (50/60 Hz nominal) |
| Efficiency (at 115 VAC) | 81% typ. (at 100 VAC, 100% load) |
| Efficiency (at 230 VAC) | 83% typ. (at 200 VAC, 100% load) |
| AC Input Current (at 115 VAC) | 0.45 A typ. (at 100 VAC, 100% load) |
| AC Input Current (at 230 VAC) | 0.25 A typ. (at 200 VAC, 100% load) |
| Inrush Current (Cold Start at 115 VAC) | 15 A typ. (at 100 VAC, Ta = 25 °C) |
| Inrush Current (Cold Start at 230 VAC) | 30 A typ. (at 200 VAC, Ta = 25 °C) |
| Power Factor (PF at 115 VAC) | 0.98 typ. (at 100 VAC, 100% load) |
| Power Factor (PF at 230 VAC) | 0.90 typ. (at 200 VAC, 100% load) |
| Power Factor Correction (PFC) | Built-In Active PFC (EN 61000-3-2 Class A) |
| Mounting Style | Chassis Mount (Bottom & Side M3 Threaded Mounting Holes; Optional DIN Rail Bracket) |
| Cooling Method | Natural Air Convection (Fanless) |
| Overall Width (W) | 39 mm (1.54 in) |
| Overall Height (H) | 78 mm (3.07 in) |
| Overall Depth (D) | 103 mm (4.06 in) |
| Dimensional Tolerance | ±1.0 mm (±0.04 in) |
| Net Weight | 230 g max. (0.23 kg / 8.11 oz) |
| Termination / Connector Style | 5-Position M3 Screw Terminal Block with Barrier |
| Input Terminal Pinout | TB1 Pins 1–3: Pin 1 = AC(L), Pin 2 = AC(N), Pin 3 = FG (Frame Ground) |
| Output & Signal Terminal Pinout | TB1 Pins 4–5: Pin 4 = -V (DC Return), Pin 5 = +V (+5 VDC) |
| Status Indicator | Green LED (DC Output On) |
| Enclosure / Potting Material | Galvanized Steel Chassis with Perforated Metal Cover (-N Option) |
| Overload Protection (OLP) Threshold | 105% min. of rated output current (> 6.3 A) |
| Overload Protection (OLP) Mode | Constant Current Limiting / Intermittent Hiccup Mode (Auto-Recovery) |
| Overvoltage Protection (OVP) Threshold | 115% to 140% of nominal output voltage (5.75 to 7.0 VDC) |
| Overvoltage Protection (OVP) Mode | Latching Output Shutdown (Requires AC Input Power Recycle to Reset) |
| Short Circuit Protection (SCP) | Continuous Intermittent Hiccup Protection (Auto-Recovery upon Fault Removal) |
| Withstand Isolation Voltage (I/P to O/P) | 3,000 VAC for 1 minute (10 mA cut-off current) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2,000 VAC for 1 minute (10 mA cut-off current) |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VAC for 1 minute (20 mA cut-off current) |
| Isolation Resistance (at 500 VDC) | 100 MΩ min. (I/P-O/P, I/P-FG, O/P-FG at 25 °C, 70% RH) |
| Earth Leakage Current | 0.45 mA max. (at 100 VAC, 60 Hz); 0.75 mA max. (at 240 VAC, 60 Hz) |
| Operating Ambient Temperature Range | -10 to +70 °C (14 to 158 °F) |
| Full-Load Operating Temperature Limit | +40 °C (104 °F) at 100% load with -N cover in standard horizontal mounting |
| High-Temperature Derating Rate | Linear derating from 100% load at +40 °C to 50% at +60 °C and 20% at +70 °C (-N cover) |
| Low-Line Input Derating | Linear derating from 100% load at 100 VAC down to 80% load at 85 VAC |
| Storage Temperature Range | -20 to +75 °C (-4 to 167 °F) |
| Operating Relative Humidity | 20% to 90% RH (Non-Condensing) |
| Storage Relative Humidity | 20% to 90% RH (Non-Condensing) |
| Temperature Coefficient | ±0.02%/°C max. (across 0 to +50 °C) |
| Vibration Resistance | 10 to 55 Hz, 19.6 m/s² (2G), 3 minutes period, 60 minutes each along X, Y, Z axes |
| Safety Approvals (UL / North America) | UL 60950-1, UL 62368-1, C-UL (CSA C22.2 No. 60950-1 / 62368-1) |
| Safety Approvals (IEC / EN / TÜV) | EN 60950-1, EN 62368-1, CE, UKCA |
| Safety Approvals (Regional / Global) | DENAN (PSE Japan) |
| EMC Conducted & Radiated Emissions | FCC Part 15 Class B, CISPR 22 Class B, CISPR 32 Class B, EN 55011 Class B, EN 55032 Class B, VCCI Class B |
| EMC Harmonic & Flicker Compliance | IEC 61000-3-2 Class A, IEC 61000-3-3 |
| EMC Immunity Standards | IEC 61000-4-2 (ESD), IEC 61000-4-3 (Radiated RF), IEC 61000-4-4 (EFT/Burst), IEC 61000-4-5 (Surge), IEC 61000-4-6 (Conducted RF), IEC 61000-4-8 (Magnetic Field), IEC 61000-4-11 (Voltage Dips) |
| Environmental Compliance | RoHS Compliant |
Industrial Applications & Compatible Systems
The Cosel PBA30F-5-N provides a reliable, noise-suppressed 5 VDC logic and peripheral rail across industrial automation, test instrumentation, and embedded machinery:
- Factory Automation & PLC Logic Rails: Powers 5 VDC TTL/CMOS logic backplanes, rotary encoders, optical sensors, and digital I/O interface cards inside industrial control panels.
- Semiconductor & PCB Test Instrumentation: Supplies low-ripple 5 VDC bias rails for automated test equipment (ATE), benchtop analyzers, and precision data acquisition modules.
- Communications & Embedded Kiosk Hardware: Drives single-board computers (SBCs), industrial HMI touchscreens, barcode scanners, and thermal receipt printers in rugged enclosures.
- MRO Replacement for Legacy Cosel PBA Installations: Serves as an exact drop-in replacement for existing PBA30F-5-N chassis units in Japanese and global CNC, packaging, and molding machinery.
Installation, Thermal Management & MRO Guidelines
Follow these thermal, mechanical, and electrical integration practices to ensure long-term reliability:
- Convection Clearance & Cover Derating (-N Option): Maintain at least 15 mm (0.6 in) of unobstructed airflow clearance around the perforated metal cover and derate continuous load linearly above +40 °C (104 °F) down to 50% at +60 °C (140 °F).
- Chassis Mounting Screw Depth Control: Use M3 mounting screws on the bottom or side chassis holes with a maximum penetration depth of 6 mm (0.24 in) to avoid damaging internal PCB traces or violating isolation clearances.
- Protective Earth (FG) & Surge Immunity Bonding: Always connect the FG terminal to a low-impedance chassis earth ground to ensure proper operation of the internal Class B Y-capacitors and IEC 61000-4-5 surge suppression network.
- Upstream Circuit Breaker & Inrush Coordination: Size upstream thermal-magnetic breakers (Type C or D curve) to tolerate the 30 A cold-start inrush peak at 230 VAC without nuisance tripping.