HWS3000GT-24 TDK-Lambda 3000W 24VDC 3-Phase Power Supply

$1,344.43

TDK-Lambda HWS3000GT-24 (HWS3000GT24) 3000W 24VDC 125A 3-phase programmable AC-DC power supply, 170-265VAC input, 91% efficiency, RS-485 Modbus RTU and UL 62368-1.

SKU: HWS3000GT-24 Category: Brand:

Description

TDK-Lambda HWS3000GT-24 (also known as HWS3000GT24) is a 3,000W programmable chassis-mount AC-DC power supply from the HWS3000GT Series, where the -24 suffix denotes a 24 VDC nominal output rail and the blank option code indicates standard commercial cooling without /HD ruggedization or /RF reverse airflow. Engineered with a high-frequency switching topology operating at 120 kHz primary and 240 kHz secondary frequencies, it accepts a three-phase 170 to 265 VAC input (200–240 VAC nominal, 0.95 power factor) and delivers 0 to 125 A at 91% conversion efficiency. Output voltage is adjustable from 19.2 to 28.8 VDC via onboard potentiometer or fully programmable across 0 to 28.8 VDC and 0 to 125 A in constant-voltage/constant-current (CV/CC) mode via RS-485 Modbus RTU or 1–5 V / 4–20 mA analog control, maintaining 96 mV line regulation, 192 mV load regulation, and 300 mVp-p ripple and noise.

Comprehensive system protection includes constant-current overload protection (>131.2 A with automatic recovery and 30-second shutdown latch) and overvoltage protection (30.4 to 31.5 VDC), backed by 3,000 VAC input-to-output, 2,000 VAC input-to-ground, and 1,500 VAC output-to-ground galvanic isolation. Housed in a low-profile 270 × 150 × 61 mm (10.63 × 5.91 × 2.4 in) chassis with variable-speed rear-exhaust fan cooling and user-configurable vertical or horizontal output screw terminals, the unit supports -40 °C cold start-up and full-load operation up to +50 °C (+122 °F) before linear derating to 50% at +70 °C (+158 °F). The power supply carries IEC/EN/UL/CSA 62368-1, IEC/EN 62477-1 (OVC III up to 2,000 m), SEMI F47, CE, and UKCA approvals, alongside a 7-year manufacturer warranty in the Americas and EMEA.

Key Features

  • High-Density 3-Phase 3,000W Output: Delivers 24 VDC nominal at 0 to 125 A (3,000 W continuous) from a 3-phase 170–265 VAC input at 91% efficiency and 0.95 power factor.
  • Full Digital & Analog CV/CC Programmability: Adjusts output voltage from 0 to 28.8 VDC and current from 0 to 125 A via RS-485 Modbus RTU (4,000-step resolution) or 1–5 V / 4–20 mA signals.
  • Scalable Series & Parallel Architecture: Connects up to 10 units in parallel for 30 kW high-current bus expansion or up to 3 units in series for higher system voltages.
  • Integrated Telemetry, Auxiliary Rail & Control I/O: Provides an always-on 5 V / 2 A standby output, 0.3 V remote sense compensation, Remote ON/OFF, 1–5 V V/I monitors, and AC Fail / V&I Good / Fan Fail signals.
  • 3-Zone Reinforced Isolation & Protection Suite: Features 3,000 VAC I/P-O/P, 2,000 VAC I/P-FG, and 1,500 VAC O/P-FG isolation alongside 30.4–31.5 V OVP and >131.2 A CC overload protection.
  • Wide Thermal Envelope with -40 °C Cold Start: Starts reliably at -40 °C (-40 °F) and operates from -20 °C to +70 °C (-4 °F to +158 °F) with full 3,000 W output up to +50 °C (+122 °F).
  • Ultra-Compact 61 mm Chassis & Flexible Terminals: Measures just 270 × 150 × 61 mm (10.63 × 5.91 × 2.4 in) at 2.3 kg (5.07 lbs) with reversible vertical/horizontal output busbars.
  • Global Industrial & Semiconductor Compliance: Certified to IEC/EN/UL/CSA 62368-1, IEC/EN 62477-1 OVC III, EN 55032/55011 Class A, IEC 61000-6-2, and SEMI F47 line-dip immunity.

Technical Specifications

Manufacturer TDK-Lambda
Manufacturer Part Number (MPN) HWS3000GT-24
Alternate Part Number HWS3000GT24
Product Series HWS3000GT Series
Product Category Chassis Power Supplies
Component Type Three-Phase Programmable CV/CC Chassis-Mount Power Supply
Option Code Configuration Standard (Blank — No /HD Conformal Coating or /RF Reverse Fan)
Circuit Topology & Switching Frequency Active PFC + Isolated High-Frequency Switching (Primary: 120 kHz, Secondary: 240 kHz)
Nominal Output Voltage 24 VDC
Output Voltage Adjustment Range (Potentiometer) 19.2 to 28.8 VDC
Output Voltage Programming Range (Digital / Analog) 0 to 28.8 VDC
Rated Output Current 125 A
Output Current Programming Range 0 to 125 A
Rated Output Power 3,000 W (at 3-phase 170–265 VAC input)
Minimum Load Requirement No minimum load required (0 A)
Output Ripple & Noise (Max) 300 mVp-p
Constant Voltage (CV) Line Regulation 96 mV
Constant Voltage (CV) Load Regulation 192 mV
Constant Current (CC) Line Regulation 500 mA
Constant Current (CC) Load Regulation 1,000 mA
Temperature Coefficient ±0.02 %/°C
Hold-Up Time (at 1,500 W / 50% Load) 20 ms (typical)
Hold-Up Time (at 3,000 W / 100% Load) 10 ms (typical)
Auxiliary Standby Output 5 VDC at 2 A
Remote Voltage Sense Compensation Up to 0.3 V per load line
Parallel Operation Capability Up to 10 units in parallel (up to 30 kW total)
Series Operation Capability Up to 3 units in series
Operating Input Voltage Range (AC) 3-Phase 170 to 265 VAC
Nominal Input Voltage Range (AC) 3-Phase 200 to 240 VAC (Safety certified for 180 to 264 VAC)
Input Frequency Range 47 to 63 Hz (Safety certified for 50 to 60 Hz)
Efficiency (at 220 / 230 VAC Input) 91 % (typical)
AC Input Current (at 200 / 230 VAC Input) 10 A per phase
Inrush Current (Cold Start at 200 VAC) 80 A (at 2nd inrush)
Power Factor (at 200 VAC Input) 0.95 (Active PFC)
Overcurrent Protection (OCP) Threshold > 131.2 A (> 105% of rated current)
Overcurrent Protection (OCP) Mode Constant current limiting with automatic recovery; shuts down output if overload exceeds 30 seconds
Overvoltage Protection (OVP) Threshold 30.4 to 31.5 VDC
Insulation Class Class I (Protective Earth Grounded)
Withstand Isolation Voltage (Input to Output) 3,000 VAC (for 1 minute)
Withstand Isolation Voltage (Input to Ground / FG) 2,000 VAC (for 1 minute)
Withstand Isolation Voltage (Output to Ground / FG) 1,500 VAC (for 1 minute)
Isolation Resistance (at 500 VDC) > 100 MΩ (at 25 °C, 70% RH)
Earth Leakage Current < 3 mA (at 240 VAC, 60 Hz)
Operating Ambient Temperature Range -20 °C to +70 °C (-4 °F to +158 °F); supports -40 °C (-40 °F) cold start-up
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 100% load (3,000 W)
High-Temperature Derating Rate Linear derating of 2.5 %/°C from +50 °C to +70 °C (50% / 1,500 W load at +70 °C)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Humidity Range 20% to 90% RH (non-condensing)
Storage Humidity Range 10% to 95% RH (non-condensing)
Maximum Operating & Storage Altitude 5,000 m / 16,404 ft (2,000 m / 6,562 ft for IEC/EN 62477-1 OVC III)
Vibration Resistance (Non-Operating) 10 to 55 Hz (1 min sweep), max 19.6 m/s² (2 G), 1 hour per axis
Shock Resistance < 196 m/s² (< 20 G)
MTBF (Telcordia SR-332 at +25 °C) 825,678 hours (at 24V, 125A, 230 VAC input)
MTBF (Telcordia SR-332 at +40 °C) 527,785 hours (at 24V, 125A, 230 VAC input)
Safety Certifications & Standards IEC/EN/UL/CSA 62368-1, IEC/EN 62477-1 (OVC III, 2,000 m), CE Mark, UKCA Mark
Conducted & Radiated EMI Emissions EN 55032 Class A, EN 55011 Class A, FCC Part 15 Class A
Harmonic Current Compliance IEC 61000-3-2
EMC Immunity Overview Standard IEC 61000-6-2 (Industrial Environment)
Electrostatic Discharge (ESD) Immunity EN 61000-4-2: Contact Discharge Levels 1, 2 (Criteria B); Air Discharge Levels 1, 2, 3 (Criteria B)
Radiated RF Immunity EN 61000-4-3: Level 3 at 80 MHz–1.0 GHz (Criteria A); Level 2 at 1.4–6.0 GHz (Criteria A)
Electrical Fast Transient / Burst (EFT) Immunity EN 61000-4-4: Levels 1, 2, 3 (Criteria B)
Surge Immunity EN 61000-4-5: Common Mode Levels 1, 2, 3 (Criteria B); Normal Mode Levels 1, 2 (Criteria B)
Conducted RF Susceptibility EN 61000-4-6: Levels 1, 2, 3 (Criteria A)
Power Frequency Magnetic Field Immunity EN 61000-4-8: Levels 1, 2, 3, 4 (Criteria A)
Voltage Dips & Short Interruptions Immunity EN 61000-4-11: 30% 500 ms (Criteria A), 60% 200 ms (Criteria A), 100% 20 ms (Criteria A), 100% 5,000 ms (Criteria C on L1-L2/L2-L3, Criteria A on L3-L1)
Semiconductor Line Dip Compliance SEMI F47 (at input voltages > 200 VAC)
Digital Communication Interface RS-485 Modbus RTU (controls Vout/Iout 0–4,000 counts, status, product life, OCP/OVP/AC Fail logs)
Analog Voltage & Current Programming (CV / CC) External 1–5 VDC or 4–20 mA applied to CV and CC terminals (0% to 100% output scaling)
Analog Voltage & Current Monitor Outputs VB terminal (1–5 VDC for 0–100% Vout); CB terminal (1–5 VDC for 0–100% Iout)
Status & Control Signals Remote ON/OFF, AC Fail, Voltage & Current Good, Fan Fail (Open-collector outputs)
Input & Output Terminal Configuration Screw terminals with protective covers (Output busbars user-configurable for vertical or horizontal orientation)
Cooling Method & Acoustic Noise Internal variable-speed fan (rear air exhaust); 45 dBA typical at +25 °C and 70% load
Mounting Style & Chassis Fasteners Chassis Mount via 9-M4 bottom/side mounting holes (6 mm max screw penetration depth)
Overall Width (W) 150 mm (5.91 in)
Overall Height (H) 61 mm (2.40 in)
Overall Length / Depth (L) 270 mm (10.63 in)
Overall Dimensions (L × W × H) 270 × 150 × 61 mm (10.63 × 5.91 × 2.40 in)
Net Weight 2,300 g / 2.30 kg (5.07 lbs)
Manufacturer Warranty 7 Years ( and EMEA regions; 5 years in other regions)

Industrial Applications & Compatible Systems

TDK-Lambda HWS3000GT-24 provides high-current, programmable 24 VDC power across demanding three-phase industrial automation, test, and process systems:

  • Semiconductor Fabrication & Wafer Processing Equipment: Supplies SEMI F47-compliant 24 VDC bulk power for chamber heaters, robot handlers, and load-port actuators in 200–240 VAC three-phase fab tools.
  • Automated Test Equipment (ATE) & Burn-In Racks: Enables closed-loop voltage (0–28.8 VDC) and constant-current (0–125 A) sweeps via RS-485 Modbus RTU or 4–20 mA PLC analog outputs.
  • Industrial Laser & Additive Manufacturing Systems: Drives high-wattage 24 VDC diode laser drivers, galvanometer scanners, and motion stages with parallel scalability up to 30 kW (10 units).
  • Electroplating, Electrolysis & Battery Formation Lines: Operates in constant-current mode with real-time 1–5 V VB/CB telemetry and fault logging for repeatable electrochemical processing.
  • Heavy Factory Automation & Robotic Welding Cells: Powers high-current 24 VDC valve manifolds, servo brakes, and industrial controllers inside compact 3-phase 200/208 VAC machine cabinets.

Installation, Thermal Management & MRO Guidelines

Installation & Engineering Guidelines: Verify that the incoming three-phase supply falls within 180–264 VAC (50/60 Hz) for UL/IEC safety compliance, and protect each phase with a 15 A to 20 A industrial thermal-magnetic breaker (D-curve recommended to ride through the 80 A second cold-start inrush). Maintain unobstructed front-to-rear airflow across the variable-speed cooling fan and derate output load linearly at 2.5%/°C above +50 °C (+122 °F) down to 1,500 W at +70 °C (+158 °F). When mounting to an equipment chassis via the 9-M4 mounting holes, limit screw penetration strictly to 6 mm maximum to prevent internal PCB clearance violations, and keep factory shorting jumpers installed on CN41 (-R to AG) and CN61 (+L to +S, -L to -S) unless wiring external Remote ON/OFF or 0.3 V remote sense lines.