Description
TDK-Lambda RWS1500B-36/S (also known as RWS1500B36S) is a high-density, single-output enclosed AC-DC chassis power supply from the general-purpose RWS1000/1500-B Series. The -36 model code designates a nominal 36 VDC output adjustable across 30.6 to 43.2 VDC at up to 42 A continuous current for a maximum rated power of 1512 W, while the /S option suffix integrates an isolated, always-on 5 V 1 A auxiliary standby rail. Engineered with an active power factor correction stage (65 kHz) driving an 85 kHz main switching converter, the unit accepts a universal 85 to 265 VAC input (plus 120 to 340 VDC) and delivers 85% efficiency at 115 VAC and 88% efficiency at 230 VAC with 250 mVp-p maximum ripple and noise.
Comprehensive fault protection includes constant-current overload limiting above 105% (shutting down if sustained beyond 5 seconds), alongside latching overvoltage and overtemperature shutdowns requiring an AC input cycle to reset. Galvanic isolation is rated at 4,000 VAC (input-to-output), 2,000 VAC (input-to-ground), and 1,500 VAC (output-to-ground) for 1 minute, supporting Overvoltage Category III (EN 62477-1) and IEC/UL/CSA/EN 62368-1 compliance. Housed in a compact 127 × 63 × 261 mm (5.00 × 2.48 × 10.28 in) forced-air cooled metal chassis weighing 3.0 kg (6.61 lbs), it operates reliably from -20 °C to +60 °C (full load up to +50 °C) and meets Class B conducted and radiated EMI standards.
Key Features
- High-Power 36 VDC Output & Standby Rail: Delivers 36 VDC (30.6–43.2 VDC trim range) at 42 A (1512 W) with an integrated always-on 5 V 1 A (/S) auxiliary standby supply.
- Universal AC Input with Active PFC: Operates across 85–265 VAC (47–63 Hz) and 120–340 VDC with active power factor correction achieving 0.98 PF at 100 VAC and 0.95 PF at 200 VAC.
- High Conversion Efficiency & Low Ripple: Achieves 85% typical efficiency at 115 VAC and 88% at 230 VAC while maintaining 144 mV line regulation, 216 mV load regulation, and 250 mVp-p ripple.
- 4 kVAC Reinforced 3-Zone Isolation: Provides 4,000 VAC input-to-output, 2,000 VAC input-to-ground, and 1,500 VAC output-to-ground dielectric withstand ratings with under 1.2 mA earth leakage current.
- Class B EMI & Industrial Line Immunity: Complies with EN 55011/EN 55032 Class B, FCC Class B, VCCI-B, IEC 61000-3-2 harmonics, SEMI F47 line dips, and EN 61000-4-2 through -4-11 immunity.
- Comprehensive Fault Protection & Remote Sense: Features constant-current overload protection above 105% (5-second shutdown timer), latching OVP and OTP, remote voltage sensing, and a green DC OK indicator LED.
- Compact Chassis & Long Service Reliability: Measures 127 × 63 × 261 mm (5.00 × 2.48 × 10.28 in) with configurable screw terminal orientation, 1,222,361-hour Telcordia MTBF, and 7-year regional warranty.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | RWS1500B-36/S |
| Alternate Part Number | RWS1500B36S |
| Product Series | RWS1000/1500-B Series |
| Product Category | Chassis Power Supplies |
| Component Type | Enclosed Single-Output Industrial AC-DC Power Supply |
| Circuit Topology | Active PFC Boost + Isolated Switching Converter |
| Nominal Output Voltage | 36 VDC |
| Output Voltage Adjustment Range | 30.6 to 43.2 VDC |
| Rated Output Current | 42 A |
| Output Current Range | 0 to 42 A (No minimum load required) |
| Rated Output Power | 1512 W |
| Auxiliary Standby Output (/S Option) | 5 VDC at 1 A (Isolated, always-on) |
| Output Ripple & Noise (Max) | 250 mVp-p |
| Line Regulation (Max) | 144 mV |
| Load Regulation (Max) | 216 mV |
| Hold-Up Time (at 115 VAC) | 20 ms |
| Hold-Up Time (at 230 VAC) | 20 ms |
| Maximum External Capacitive Load | 100,000 µF |
| Temperature Coefficient | ±0.02 %/°C |
| Series Operation Capability | Supported (external blocking diodes required) |
| Operating AC Input Voltage Range | 85 to 265 VAC (Derate linearly to 80% load below 90 VAC) |
| Safety-Certified AC Input Voltage Range | 90 to 264 VAC |
| Nominal AC Input Voltage Range | 100 to 240 VAC |
| Input Frequency Range | 47 to 63 Hz (Safety certified for 50 / 60 Hz) |
| DC Input Voltage Range | 120 to 340 VDC (Not safety certified for DC input) |
| Efficiency (Typical at 115 VAC) | 85% |
| Efficiency (Typical at 230 VAC) | 88% |
| AC Input Current (Typical at 110 VAC) | 19 A |
| AC Input Current (Typical at 230 VAC) | 10 A |
| Inrush Current (Cold Start at 100 VAC) | 60 A |
| Inrush Current (Cold Start at 200 VAC) | 60 A |
| Power Factor (Typical at 100 VAC) | 0.98 |
| Power Factor (Typical at 200 VAC) | 0.95 |
| Switching Frequency | 85 kHz (Main Converter) / 65 kHz (PFC Stage) |
| Overload Protection (OLP) Threshold | > 105% of rated output current |
| Overload Protection (OLP) Mode | Constant current limiting with auto-recovery; shuts down if overload exceeds 5 seconds |
| Overvoltage Protection (OVP) Mode | Latching shutdown (Recycle AC input power to reset) |
| Overtemperature Protection (OTP) Mode | Latching shutdown (Recycle AC input power to reset) |
| Withstand Isolation Voltage (I/P to O/P) | 4,000 VAC (1 minute) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2,000 VAC (1 minute) |
| Withstand Isolation Voltage (O/P to FG / Case) | 1,500 VAC (1 minute) |
| Earth Leakage Current | < 1.2 mA |
| Overvoltage Category | OVC III (per EN 62477-1) |
| Operating Ambient Temperature | -20 °C to +60 °C (-4 °F to +140 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% rated load |
| High-Temperature Derating Rate | Linear derating at 4.0 %/°C from +50 °C to +60 °C (60% load at +60 °C) |
| Low-Line Input Derating | Linear derating from 100% load at 90 VAC to 80% load at 85 VAC |
| Storage Temperature Range | -30 °C to +75 °C (-22 °F to +167 °F) |
| Operating Humidity Range | 20% to 90% RH (Non-condensing) |
| Storage Humidity Range | 10% to 90% RH (Non-condensing) |
| Operating Altitude | Up to 3,000 m (9,842 ft) |
| Vibration Resistance (Non-Operating) | 10 to 55 Hz (1 min sweep), 19.6 m/s² (2G) constant along X, Y, Z axes for 1 hour each |
| Shock Resistance (Non-Operating) | < 196 m/s² (20G), 11 ms half-sine, ±X, ±Y, ±Z 3 times each |
| MTBF (Telcordia SR-332 Issue 3) | 1,222,361 hours (at +25 °C ambient, full load) |
| Safety Certifications (North America) | UL 62368-1, CSA C22.2 No. 62368-1, UL 60950-1 |
| Safety Certifications (International & Europe) | IEC 62368-1, EN 62368-1, IEC/EN 60950-1, EN 62477-1 (OVC III) |
| Regional Compliance Markings | CE Mark, UKCA Mark |
| Conducted & Radiated EMI Emissions | EN 55011 Class B, EN 55032 Class B, FCC Part 15 Class B, VCCI Class B |
| Harmonic Current Emissions (EN 61000-3-2) | Complies with IEC / EN 61000-3-2 |
| ESD Immunity (EN 61000-4-2) | Air discharge ±8 kV, Contact discharge ±4 kV (Performance Criteria B) |
| Radiated RF Immunity (EN 61000-4-3) | 80 MHz–1 GHz: 10 V/m; 1.4–2.0 GHz: 3 V/m; 2.0–2.7 GHz: 1 V/m (Criteria A) |
| EFT / Burst Immunity (EN 61000-4-4) | ±2 kV (Performance Criteria B) |
| Surge Immunity (EN 61000-4-5) | Normal mode ±2 kV, Common mode ±4 kV (Performance Criteria B) |
| Conducted RF Immunity (EN 61000-4-6) | 10 Vrms (Performance Criteria A) |
| Power Frequency Magnetic Immunity (EN 61000-4-8) | 30 A/m (Performance Criteria A) |
| Voltage Dips & Interruptions (EN 61000-4-11) | 30% 500ms (B), 60% 10ms (B), 100% 20ms (A), 100% 5000ms (B) |
| Medical Voltage Dips Compliance (EN 60601-1-2 Ed. 4) | 30% 500ms (B), 100% 10ms (A), 100% 20ms (A), 100% 5000ms (B) |
| Semiconductor Voltage Sag Immunity | SEMI F47 compliant (at input voltages > 200 VAC) |
| Remote Sense Function | Included (+S / -S terminals compensate for load lead voltage drop) |
| Local Status Indicator | Green LED (Illuminates when DC output is OK) |
| Input & Output Power Connectors | Screw terminal blocks (Configurable output terminal block orientation) |
| Signal & Auxiliary Standby Connector | JST S12B-PHDSS 12-pin header (Provides 5V 1A standby & remote sense pins) |
| Cooling Method | Internal forced-air cooling (Standard airflow enters over input/output terminals) |
| Mounting Style & Fasteners | Chassis mount via 8× M4 tapped holes (5 mm maximum screw penetration depth) |
| Overall Width (W) | 127 mm (5.00 in) |
| Overall Height (H) | 63 mm (2.48 in) |
| Overall Depth / Length (D/L) | 261 mm (10.28 in) |
| Overall Dimensions (W × H × D) | 127 × 63 × 261 mm (5.00 × 2.48 × 10.28 in) |
| Net Weight | 3,000 g / 3.00 kg (6.61 lbs) |
| Manufacturer Warranty | 7 Years ( & EMEA regions; 5 years in other regions) |
Industrial Applications & Compatible Systems
TDK-Lambda RWS1500B-36/S delivers regulated 36 VDC high-current power alongside an always-on 5 V 1 A standby rail for demanding industrial automation and test infrastructure:
- Industrial Robotics & Automated Material Handling: Powers 36 VDC brushless DC servo actuators, AGV/AMR onboard charging docks, and gantry drives with up to 100,000 µF capacitive load startup capability.
- Semiconductor Wafer Fabrication & Test Equipment: Meets SEMI F47 line-sag immunity above 200 VAC and Class B EMI limits to prevent interference in sensitive metrology, burn-in racks, and ATE fixtures.
- Laser Processing, UV Curing & Industrial Printing: Provides low-ripple 36 VDC bulk power for high-power LED curing arrays, industrial inkjet printhead banks, and laser diode drivers.
- Process Control & Factory Automation Cabinets: Satisfies EN 62477-1 Overvoltage Category III requirements for direct distribution-panel installation while keeping supervisory logic alive via the isolated 5 V standby output.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: Mount the chassis securely using the 8× M4 tapped mounting holes, ensuring screw penetration never exceeds 5 mm to avoid damaging internal PCB clearances. Maintain unobstructed airflow clearance in front of the input/output terminals and rear exhaust vents, as standard airflow enters over the terminal end; derate maximum output load linearly by 4.0 %/°C above +50 °C (down to 60% at +60 °C) and by 20% between 90 VAC and 85 VAC. Size upstream AC branch protection for the 19 A (110 VAC) / 10 A (230 VAC) steady-state input current and 60 A cold-start inrush, and route remote sense (+S/-S) wires as a twisted pair directly to the load terminals.