Description
TDK-Lambda HWS100A-48/A (also known as HWS100A48A) is an ultra-reliable 101W (100.8W) single-output enclosed AC-DC chassis power supply from the flagship industrial HWS-A Series, engineered with conservatively rated electrolytic capacitors to support an industry-unique Limited Lifetime Warranty. Decoding the manufacturer nomenclature, HWS100A denotes the fourth-generation 100W high-reliability industrial platform, -48 specifies the nominal 48 VDC output delivering up to 2.1 A continuous current (front-panel potentiometer adjustable from 38.4 to 52.8 VDC), and the /A suffix designates the factory-installed protective perforated metal cover. Powered by a dual-stage active PFC converter switching at 65 kHz (PFC) / 120 kHz (DC-DC), it accepts a universal 85 to 265 VAC (47–63 Hz) or 120 to 370 VDC input with 300 VAC 5-second surge withstand. The supply achieves up to 90% efficiency at 230 VAC (88% at 115 VAC), tight 192 mV line regulation, 200 mV load regulation, and low 200 mVp-p maximum ripple and noise.
Housed in a slim, convection-cooled aluminum chassis measuring 33.5 × 83 × 160.5 mm (1.32 × 3.27 × 6.32 in) and weighing 470 g (1.04 lbs), the HWS100A-48/A integrates a 7-position M3.5 screw terminal block with dedicated +S / -S remote sense terminals and a green DC OK LED indicator. Comprehensive protection circuits safeguard automation buses via constant-current plus hiccup overload protection (>105% rating) with automatic recovery and latching overvoltage protection (55.2 to 64.8 VDC). Reinforced galvanic isolation withstands 3,000 VAC input-to-output, 2,000 VAC input-to-ground, and 500 VAC output-to-ground while maintaining earth leakage current below 0.5 mA. Certified to UL 508, IEC/EN/UL/CSA 62368-1, SEMI F47, and EN 55011 / EN 55032 Class B EMI, it operates across -10 °C to +70 °C (+14 °F to +158 °F) with 100% full-load output up to +50 °C (+122 °F).
Key Features
- Precision 48 VDC / 2.1 A Regulated Output: Delivers 100.8 W (101 W rated) continuous power with a wide 38.4 to 52.8 VDC potentiometer trim range, 192 mV line regulation, 200 mV load regulation, and 200 mVp-p max ripple.
- Active PFC & High Conversion Efficiency: Built-in active power factor correction achieves 0.98 PF at 100 VAC and 0.93 PF at 200 VAC per IEC 61000-3-2 Class A, reaching 88% efficiency at 115 VAC and 90% at 230 VAC.
- Universal AC/DC Input & Surge Resilience: Operates across 85 to 265 VAC (47–63 Hz) or 120 to 370 VDC, surviving 300 VAC line surges for 5 seconds and delivering a 20 ms typical hold-up time.
- Remote Voltage Sensing & CC/Hiccup Protection: Standard +S and -S remote sense terminals compensate for cable voltage drops, paired with >105% constant-current/hiccup overload recovery and 55.2–64.8 VDC latching OVP.
- 3,000 VAC Galvanic Isolation & Industrial Approvals: Provides 3,000 VAC input-to-output and 2,000 VAC input-to-ground dielectric strength, certified to UL 508 industrial control, IEC/EN/UL 62368-1, and SEMI F47 voltage dip standards.
- Class B EMI Filtering & High-Immunity Design: Meets EN 55011, EN 55032, FCC, and VCCI Class B conducted and radiated emissions without external filters, alongside EN 61000-4-5 ±4 kV surge immunity.
- Slim 33.5 mm Aluminum Chassis & Lifetime Warranty: Compact 33.5 × 83 × 160.5 mm (1.32 × 3.27 × 6.32 in) enclosed package features side and base M3 mounting points, 2,963,512-hour Telcordia MTBF, and a Limited Lifetime Warranty.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | HWS100A-48/A |
| Alternate Part Number | HWS100A48A |
| OEM Cross-Reference / Replaced Part | HWS100-48/A (Legacy HWS Series Direct Drop-In Replacement) |
| Product Series | HWS-A Series (HWS15A–150A Family) |
| Product Category | Chassis Power Supplies |
| Component Type | Enclosed Single-Output Industrial AC-DC Power Supply (with Cover /A) |
| Circuit Topology | Active PFC Boost + PWM Switching Mode (SMPS) |
| Nominal Output Voltage | 48 VDC |
| Output Voltage Adjustment Range | 38.4 to 52.8 VDC (-20% to +10% via Front Potentiometer) |
| Rated Output Current | 2.1 A |
| Output Current Range | 0 to 2.1 A (No Minimum Load Required) |
| Rated Output Power | 101 W (100.8 W Continuous) |
| Number of Outputs | 1 Output (Single Channel) |
| Output Ripple & Noise (Max.) | 200 mVp-p |
| Line Regulation | 192 mV max. (85 to 265 VAC input variation) |
| Load Regulation | 200 mV max. (0% to 100% load variation) |
| Hold-Up Time | 20 ms typ. (at 115 / 230 VAC) |
| Max. Capacitive Load | 1,000 µF |
| AC Input Voltage Range | 85 to 265 VAC (300 VAC surge withstand for 5 seconds; Safety certified for 90 to 264 VAC) |
| DC Input Voltage Range | 120 to 370 VDC (Safety certified for AC input only) |
| Nominal Input Voltage | 100 to 240 VAC |
| Input Frequency Range | 47 to 63 Hz (Safety certified for 50 to 60 Hz) |
| Efficiency (at 115 VAC) | 88% typ. |
| Efficiency (at 230 VAC) | 90% typ. |
| AC Input Current (at 115 VAC) | 1.3 A typ. (at 100 VAC full load) |
| AC Input Current (at 230 VAC) | 0.65 A typ. (at 200 VAC full load) |
| Inrush Current (Cold Start at 115 VAC) | 14 A typ. (at 100 VAC cold start) |
| Inrush Current (Cold Start at 230 VAC) | 28 A typ. (at 200 VAC cold start) |
| Power Factor (PF at 115 VAC) | 0.98 typ. (at 100 VAC full load) |
| Power Factor (PF at 230 VAC) | 0.93 typ. (at 200 VAC full load) |
| Power Factor Correction (PFC) | Active PFC (Meets IEC/EN 61000-3-2 Class A) |
| No-Load Power Consumption | 0.3 to 4.6 W (Model Dependent) |
| Switching Frequency | 120 kHz typ. (Main DC-DC Converter) / 65 kHz typ. (Active PFC Converter) |
| Mounting Style | Chassis Mount (4x M3 Embossed, Tapped & Countersunk Holes on Base and Side; Max. 6 mm Screw Penetration) |
| Cooling Method | Free Air Convection |
| Overall Width (W) | 33.5 mm (1.32 in) |
| Overall Height (H) | 83.0 mm (3.27 in) |
| Overall Depth (D) | 160.5 mm (6.32 in) (Excluding 10 mm max. terminal block projection) |
| Dimensional Tolerance | ±1.0 mm (±0.039 in) outer envelope; ±0.5 mm (±0.020 in) mounting hole pitch |
| Mounting Hole Pitch | Side Mounting: 125.0 × 20.5 mm (4.92 × 0.81 in); Base Mounting: 135.0 mm (5.31 in) length pitch |
| Net Weight | 470 g (0.47 kg / 1.04 lbs / 16.58 oz) |
| Termination / Connector Style | 7x M3.5 Screw Terminals with Captive Washer Plates (9.5 mm pitch) |
| Input Terminal Pinout | Front Terminal Block (Bottom Pins): FG (Frame Ground), AC(L) (Live), AC(N) (Neutral) |
| Output & Signal Terminal Pinout | Front Terminal Block (Top Pins): +S (+Remote Sense), +V (+DC Output), -V (-DC Output), -S (-Remote Sense); Shipped with +S to +V and -S to -V shorting bars installed |
| Control & Monitoring Signals | Remote Sense (+S / -S standard); Optional Remote On/Off via JST B2B-XH-AM header on /R suffix models |
| Status Indicator | Green LED (DC OK) |
| Enclosure / Potting Material | Perforated Aluminum Chassis and Protective Cover (/A) |
| Overload Protection (OLP) Threshold | >105% of Rated Output Current |
| Overload Protection (OLP) Mode | Constant Current Limiting combined with Hiccup Mode; Automatic Recovery upon fault removal |
| Overvoltage Protection (OVP) Threshold | 55.2 to 64.8 VDC |
| Overvoltage Protection (OVP) Mode | Latching Shutdown (Cycle AC input power to reset) |
| Short Circuit Protection (SCP) | Continuous Constant Current & Hiccup Mode with Automatic Recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3,000 VAC for 1 minute |
| Withstand Isolation Voltage (I/P to FG / Case) | 2,000 VAC for 1 minute |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VAC for 1 minute |
| Isolation Resistance (at 500 VDC) | >100 MΩ at 25 °C (77 °F) and 70% RH |
| Earth Leakage Current | <0.5 mA max. (0.2 mA typ. at 100 VAC, 0.4 mA typ. at 230 VAC) |
| Operating Ambient Temperature Range | -10 °C to +70 °C (+14 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% Load (with /A cover) |
| High-Temperature Derating Rate | Derate linearly at 4.0% per °C from 100% load at +50 °C (+122 °F) to 20% load at +70 °C (+158 °F) |
| Altitude Derating | Up to 4,000 m (13,123 ft) maximum operating altitude |
| Storage Temperature Range | -30 °C to +85 °C (-22 °F to +185 °F) |
| Operating Relative Humidity | 30% to 90% RH (Non-condensing) |
| Storage Relative Humidity | 10% to 95% RH (Non-condensing) |
| Temperature Coefficient | ±0.02% / °C |
| Vibration Resistance | 10 to 55 Hz (1 min sweep), 19.6 m/s² (2G) constant acceleration along X, Y, Z axes for 1 hour each (Non-operating); Shock <196 m/s² (20G) |
| Safety Approvals (UL / North America) | UL 508 (Industrial Control Equipment), UL 62368-1, CSA C22.2 No. 62368-1 |
| Safety Approvals (IEC / EN / TÜV) | IEC/EN 62368-1 |
| Safety Approvals (Regional / Global) | CE Mark, UKCA Mark, SEMI F47 Line Dip Compliant (at >200 VAC input) |
| EMC Conducted & Radiated Emissions | EN 55011 Class B, EN 55032 Class B, FCC Part 15 Class B, VCCI Class B |
| EMC Harmonic & Flicker Compliance | IEC/EN 61000-3-2 Class A |
| EMC Immunity Standards | EN 61000-4-2 (ESD: ±8 kV Air, ±6 kV Contact, Criteria B), EN 61000-4-3 (Radiated RF: 10 V/m 80M–1GHz, Criteria A), EN 61000-4-4 (EFT/Burst: ±2 kV, Criteria B), EN 61000-4-5 (Surge: ±4 kV Common Mode, ±2 kV Normal Mode, Criteria B), EN 61000-4-6 (Conducted RF: 10 Vrms, Criteria A), EN 61000-4-8 (Magnetic Field: 30 A/m, Criteria A), EN 61000-4-11 (Voltage Dips), SEMI F47 |
| MTBF (Telcordia SR-332 / Bellcore) | 2,963,512 Hours (Telcordia SR-332 Issue 3, 24V reference model at +55 °C ambient, full load, 230 VAC input) |
| Environmental Compliance | RoHS Compliant, Limited Lifetime Warranty (Americas & EMEA) / 5-Year Warranty (APAC) |
Industrial Applications & Compatible Systems
The TDK-Lambda HWS100A-48/A is purpose-built for continuous-duty 48 VDC industrial, semiconductor, and telecom subsystems requiring ultra-long capacitor service life and Class B EMI performance:
- Factory Automation & UL 508 Control Panels: Powers 48 VDC stepper and brushless DC servo drives, distributed I/O blocks, and PLC backplanes inside high-density industrial machinery cabinets.
- Semiconductor Fabrication & Wafer Processing Equipment: Certified to SEMI F47 line-dip ride-through standards (at >200 VAC), safeguarding cleanroom metrology, lithography, and robotic wafer-handling controllers against AC grid sags.
- Telecommunications, PoE & Optical Networking: Provides a low-noise 48 VDC (adjustable 38.4–52.8 VDC) bus for industrial Power-over-Ethernet (PoE) switches, base station transceivers, and fiber-optic distribution frames.
- Test, Measurement & Automated Inspection Systems: Supplies tightly regulated power with remote voltage sensing to precision ATE racks, vision inspection illuminators, and laboratory instrumentation.
Installation, Thermal Management & MRO Guidelines
Follow these engineering best practices during cabinet integration and MRO replacement of the HWS100A-48/A:
- Chassis Screw Penetration & Mounting Clearance: Secure the aluminum chassis using the embossed M3 tapped holes on the side (125 × 20.5 mm pitch) or bottom (135 mm pitch), ensuring customer M3 mounting screws never protrude more than 6.0 mm (0.24 in) into the power supply enclosure.
- Convection Thermal Derating Above +50 °C: Maintain unrestricted airflow around the perforated /A cover for 100% full-load operation (2.1 A / 101 W) up to +50 °C (+122 °F); above +50 °C, derate continuous output load linearly at 4.0% per °C down to 20% load (0.42 A) at +70 °C (+158 °F).
- Remote Sense Wiring & Parallel Prohibition: Leave the factory-mounted shorting links between +S/+V and -S/-V installed for local voltage regulation, or remove them to connect twisted-pair sense leads directly at the load terminals; never wire multiple HWS100A-48/A outputs directly in parallel without external ORing diodes.