TPS4500-92/184 TDK-Lambda 4500W 92/184V 3-Phase PSU

$2,364.24

TDK-Lambda TPS4500-92/184 (TPS450092184) 4500W 92/184VDC 3-phase chassis PSU, 360-528VAC input, 93% efficiency, featuring PMBus, CV/CC control & UL62368-1.

SKU: TPS4500-92/184 Category: Brand:

Description

TDK-Lambda TPS4500-92/184 (also known as TPS450092184) is a high-density, 2U industrial chassis-mount AC-DC power supply engineered for global 3-phase Delta or Wye installations operating across 360–528 VAC (400/440/480 VAC nominal). Within the TPS4500 series nomenclature, the -92/184 suffix specifies dual-output voltage rails configurable for simultaneous or proportional load sharing at 92 VDC (49 A rated, 50 A maximum) and 184 VDC (24.5 A rated, 25 A maximum), delivering 4500 W continuous rated power and up to 4600 W peak output at nominal line voltage. Achieving 93% typical conversion efficiency and a 0.92 typical power factor, the unit supports flexible constant-voltage and constant-current (CV/CC) operation with wide output adjustment via onboard trim potentiometers, external 0–5 V analog programming, or digital PMBus/I2C communication, while holding ripple and noise below 2% peak-to-peak and total regulation within 1.75%.

Built for harsh industrial environments, the TPS4500-92/184 integrates comprehensive fault protection including adjustable constant-current overload limiting (65% to >100% rated current), 115% tracking overvoltage protection with AC-cycle or remote-inhibit reset, automatic-recovery overtemperature protection, and fan-failure monitoring. Reinforced galvanic isolation provides 3000 VAC withstand strength from input to output, 2000 VAC from input to ground, and 500 VDC from output to ground. Variable-speed internal fan cooling supports full-load operation up to +50 °C (+122 °F) and cold start-up down to -40 °C (-40 °F), with linear power derating to 55% at +70 °C (+158 °F). Housed in a rugged 107 × 85 × 335 mm (4.21 × 3.35 × 13.2 in) 2U chassis meeting MIL-STD-810H shock and vibration standards, the supply carries IEC/UL/CSA/EN 62368-1, CE, and UKCA approvals.

Key Features

  • Global 3-Phase Input Architecture: Operates directly from 360 to 528 VAC (400/440/480 VAC nominal) 3-phase Delta or Wye mains at 47–63 Hz with 0.92 typical power factor and 93% efficiency.
  • Dual-Output 92V / 184V Flexibility: Delivers 4500 W continuous (4600 W max at nominal line) across 92 VDC (49 A) and 184 VDC (24.5 A) outputs with arbitrary proportional load sharing.
  • Wide CV/CC Digital & Analog Programming: Adjusts output voltage down to 30–96.5 V (92V rail) or 60–193 V (184V rail) via PMBus, 0–5 V external analog signals, or trim potentiometers.
  • Comprehensive Protection & Telemetry Suite: Features adjustable constant-current OLP, 115% tracking OVP, auto-reset OTP, fan-fail detection, 12 V / 0.3 A standby rail, and open-collector DC Good, AC Fail, and Dropped Phase signals.
  • High-Reliability 3-Zone Isolation: Certified to IEC/UL/CSA/EN 62368-1 with 3000 VAC input-to-output, 2000 VAC input-to-ground, and 500 VDC output-to-ground dielectric withstand ratings.
  • Ruggedized -40 °C to +70 °C Thermal Envelope: Supports -40 °C (-40 °F) cold startup, full 4500 W output to +50 °C (+122 °F), 4000 m altitude operation, and MIL-STD-810H shock and vibration compliance.
  • Scalable Parallel & Series Expansion: Supports single-wire active current sharing for up to 8 units in parallel (derated to 90% power) or series connection for higher system bus voltages.

Technical Specifications

Manufacturer TDK-Lambda
Manufacturer Part Number (MPN) TPS4500-92/184
Alternate Part Number TPS450092184
Product Series TPS4500 Series
Product Category Chassis Power Supplies
Component Type 3-Phase Industrial Chassis-Mount AC-DC Power Supply
Circuit Topology 3-Phase Active PFC Switching AC-DC Converter (CV / CC Mode)
Nominal Output Voltage (Channel 1 / Channel 2) 92 VDC / 184 VDC (Dual Output or Single Output Proportional Load Sharing)
Output Voltage Adjustment Range (Trim Potentiometer) 57 to 99 VDC (92V Output) / 114 to 198 VDC (184V Output)
Output Voltage Adjustment Range (0–5V Analog Programming) 56 to 96.5 VDC (92V Output) / 112 to 193 VDC (184V Output)
Output Voltage Adjustment Range (PMBus Digital) 30 to 96.5 VDC (92V Output) / 60 to 193 VDC (184V Output)
Rated Output Current 49 A (at 92 VDC) / 24.5 A (at 184 VDC)
Maximum Output Current (at Nominal Input) 50 A (at 92 VDC) / 25 A (at 184 VDC)
Minimum Output Load Requirement 0.5 A (required to maintain regulation and ripple specifications)
Rated Output Power 4500 W
Maximum Output Power (at Nominal Line Voltage) 4600 W
Dropped Phase Output Power Capacity 2250 W (at 400 VAC) / 2925 W (at 480 VAC)
Output Ripple & Noise (Peak-to-Peak Max) 2% pk-pk maximum
Line Regulation < 0.25%
Load Regulation < 0.5% (< 3% on unregulated output)
Total Output Regulation < 1.75%
Cross Regulation < 3%
Warm-Up Drift < 0.25%
Temperature Stability 0.05% of rated Vout over 8 hours (after 30-minute warm-up)
Temperature Coefficient 200 ppm/°C
Hold-Up Time (at 400–480 VAC Nominal) > 10 ms (at 80% of rated current, nominal input/output voltage)
Standby Auxiliary Output 11.2 to 12.5 VDC, 0.3 A
Operating Input Voltage Range (3-Phase AC) 360 to 528 VAC, 3-Phase Delta or Wye
Nominal Input Voltage Range 400 to 480 VAC, 3-Phase Delta or Wye (Safety certified for 360–528 VAC)
Input Line Frequency 47 to 63 Hz (Safety certified for 50 to 60 Hz)
AC Input Current (at Nominal 400–480 VAC) 9 A per phase (steady state)
Inrush Current (Cold Start at 400–480 VAC) < 25 A per phase (excluding initial filter capacitor charging < 2 ms)
Power Factor (at 400–480 VAC Nominal) 0.92 typical (at rated load, nominal Vin)
Conversion Efficiency (Typical) 93%
Overload / Overcurrent Protection (OLP) Threshold Adjustable from 65% to > 100% of maximum rated current
Overload / Overcurrent Protection (OLP) Mode Constant current limiting style (optional time-delayed shutdown with auto-restart available)
Overvoltage Protection (OVP) Threshold 115% of output voltage set point (tracking)
Overvoltage Protection (OVP) Mode Latched shutdown (cycle AC input or toggle remote on/off to reset)
Overtemperature Protection (OTP) Mode Internal thermostat shutdown with automatic recovery
Fan Failure Protection Blocked rotor or fan failure detection
Withstand Isolation Voltage (Input to Output) 3000 VAC (1 minute)
Withstand Isolation Voltage (Input to Ground / Case) 2000 VAC (1 minute)
Withstand Isolation Voltage (Output to Ground / Case) 500 VDC (1 minute)
Isolation Resistance (at 500 VDC) > 100 MΩ (at 25 °C, 70% RH)
Earth Leakage Current (RMS) < 3 mA
Operating Ambient Temperature Range -10 °C to +70 °C / +14 °F to +158 °F (-40 °C / -40 °F cold start-up with 10-min warm-up at 80% load)
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 100% rated load
High-Temperature Derating Rate Linear derating from 100% to 80% load (+50 °C to +60 °C), and 80% to 55% load (+60 °C to +70 °C)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 10% to 95% RH (non-condensing)
Pollution Degree PD 2
Maximum Operating Altitude 4,000 m (13,123 ft)
Operating Vibration Compliance Designed to meet MIL-STD-810H, Method 514.8, Procedure I, Category 1 & 10
Mechanical Shock Compliance Designed to meet MIL-STD-810H, Method 516.8, Procedures I, IV (Logistics) & VI
MTBF (Telcordia SR-332 Issue 3) 250,000 hours (Method 1, Ground Benign, 25 °C, nominal input)
Safety Certifications (UL / CSA) UL 62368-1, CSA C22.2 No. 62368-1
Safety Certifications (IEC / EN / Regional) IEC 62368-1, EN 62368-1, CE Mark, UKCA Mark
EMC Conducted & Radiated Emissions EN 55032 Class A (conducted and radiated in end system; pair with RTMN-5020 filter)
EMC Line Dip Compliance SEMI F47-0706 at 480 VAC nominal (Criteria B)
EMC Immunity — ESD (EN 61000-4-2) ±8 kV air discharge, ±4 kV contact discharge
EMC Immunity — Radiated RF (EN 61000-4-3) 3 V/m, 80 MHz to 1000 MHz (80% AM at 1 kHz)
EMC Immunity — EFT / Burst (EN 61000-4-4) ±1 kV on AC power lines, ±0.5 kV on I/O signal lines
EMC Immunity — Surge (EN 61000-4-5) ±2 kV common mode (3-phase), ±1 kV differential mode
EMC Immunity — Conducted RF (EN 61000-4-6) 3 Vrms, 150 kHz to 80 MHz (1 kHz, 80% AM)
EMC Immunity — Magnetic Field (EN 61000-4-8) 30 A/m and 300 A/m inductive loop at 50 Hz
EMC Immunity — Voltage Dips & Interruptions (EN 61000-4-11) 30% voltage dip and >95% voltage dip/interruption
Communication & Telemetry Interface PMBus / I2C (Vout, Iout, Temp monitoring; Remote On/Off, V/I programming, fault clearing, manufacturing data)
Analog Control Signals 0–5 V external Voltage Programming (VADJ), 0–5 V Overcurrent Programming (IADJ), Remote On/Off (Enable/Inhibit selectable)
Status & Alarm Signals Open Collector: DC Good (>90% Vout tracking), AC Fail (>340 VAC at >30% load), Dropped Phase Warning, OTW1/OTW2
Parallel & Series Operation Single-wire active current share up to 8 units (derate to 90% output power); series connection supported
LED Status Indicators Green LEDs for AC ON and DC OK; blinking Red/Green during dropped phase (>30% load)
Input Terminal Pinout 4-Pole Barrier Terminal Block: L1, L2, L3, GND
Output Terminal Pinout Busbar / Terminal Block: V2 (184V), V1 (92V), RTN (0V)
Signal & PMBus Mating Connectors Signal: JST PHDR-20VS housing with SPHD-001T-P0.5 crimp terminals; PMBus jumper: Samtec 2SN-BK-G
Cooling Method Forced-air cooling via internal variable-speed fan
Form Factor & Mounting Style 2U Low-Profile Enclosed Chassis Mount
Overall Width (W) 107 mm (4.21 in)
Overall Height (H) 85 mm (3.35 in) — 2U height
Overall Depth / Length (D/L) 335 mm (13.2 in) excluding output connectors
Overall Dimensions (W × H × D) 107 × 85 × 335 mm (4.21 × 3.35 × 13.2 in)
Net Weight 4,000 g / 4.0 kg (8.82 lbs)
Manufacturer Warranty 3 Years

Industrial Applications & Compatible Systems

TDK-Lambda TPS4500-92/184 is purpose-built for high-power industrial automation, semiconductor processing, and distributed DC bus architectures requiring programmable constant-voltage/constant-current 92 VDC or 184 VDC power from 400–480 VAC 3-phase mains:

  • Semiconductor Wafer Fabrication & Plasma Equipment: SEMI F47-0706 line-dip immunity and PMBus digital telemetry support RF generators, ion implanters, and vacuum chamber power stages.
  • Industrial Laser Cutting, Additive Manufacturing & UV Curing: Fast 0–5 V analog or I2C/PMBus current-limit programming drives high-power diode laser arrays and solid-state curing banks.
  • Automated Battery Formation, Cell Testing & EV Subsystems: Wide 30–193 VDC programmable CV/CC output enables precision multi-channel battery module charging and cycling racks.
  • High-Voltage DC Microgrids & Industrial Robotics: Arbitrary dual-output load sharing across 92 V and 184 V buses powers multi-axis servo drives, electroplating baths, and test benches.

Installation, Thermal Management & MRO Guidelines

Installation & Engineering Guidelines: Mount the 2U chassis (107 × 85 × 335 mm) with unobstructed airflow at the front and rear fan vents, maintaining at least 50 mm clearance so internal variable-speed cooling sustains 4500 W output up to +50 °C (+122 °F); above +50 °C, derate total load linearly at 2.0%/°C to 80% at +60 °C and 2.5%/°C to 55% at +70 °C. For sub-zero cold starts down to -40 °C, apply nominal 3-phase input and allow a 10-minute warm-up at 80% load before demanding full regulation. Protect each 3-phase leg (L1, L2, L3) with a D-curve 15 A–20 A 3-pole circuit breaker to accommodate 9 A steady-state current and <25 A cold-start inrush, and install a TDK-Lambda RTMN-5020 3-phase two-stage EMC filter upstream when EN 55032 Class A system compliance is required.