Description
TDK-Lambda TPS4500-92/184 (also known as TPS450092184) is a high-density, 2U industrial chassis-mount AC-DC power supply engineered for global 3-phase Delta or Wye installations operating across 360–528 VAC (400/440/480 VAC nominal). Within the TPS4500 series nomenclature, the -92/184 suffix specifies dual-output voltage rails configurable for simultaneous or proportional load sharing at 92 VDC (49 A rated, 50 A maximum) and 184 VDC (24.5 A rated, 25 A maximum), delivering 4500 W continuous rated power and up to 4600 W peak output at nominal line voltage. Achieving 93% typical conversion efficiency and a 0.92 typical power factor, the unit supports flexible constant-voltage and constant-current (CV/CC) operation with wide output adjustment via onboard trim potentiometers, external 0–5 V analog programming, or digital PMBus/I2C communication, while holding ripple and noise below 2% peak-to-peak and total regulation within 1.75%.
Built for harsh industrial environments, the TPS4500-92/184 integrates comprehensive fault protection including adjustable constant-current overload limiting (65% to >100% rated current), 115% tracking overvoltage protection with AC-cycle or remote-inhibit reset, automatic-recovery overtemperature protection, and fan-failure monitoring. Reinforced galvanic isolation provides 3000 VAC withstand strength from input to output, 2000 VAC from input to ground, and 500 VDC from output to ground. Variable-speed internal fan cooling supports full-load operation up to +50 °C (+122 °F) and cold start-up down to -40 °C (-40 °F), with linear power derating to 55% at +70 °C (+158 °F). Housed in a rugged 107 × 85 × 335 mm (4.21 × 3.35 × 13.2 in) 2U chassis meeting MIL-STD-810H shock and vibration standards, the supply carries IEC/UL/CSA/EN 62368-1, CE, and UKCA approvals.
Key Features
- Global 3-Phase Input Architecture: Operates directly from 360 to 528 VAC (400/440/480 VAC nominal) 3-phase Delta or Wye mains at 47–63 Hz with 0.92 typical power factor and 93% efficiency.
- Dual-Output 92V / 184V Flexibility: Delivers 4500 W continuous (4600 W max at nominal line) across 92 VDC (49 A) and 184 VDC (24.5 A) outputs with arbitrary proportional load sharing.
- Wide CV/CC Digital & Analog Programming: Adjusts output voltage down to 30–96.5 V (92V rail) or 60–193 V (184V rail) via PMBus, 0–5 V external analog signals, or trim potentiometers.
- Comprehensive Protection & Telemetry Suite: Features adjustable constant-current OLP, 115% tracking OVP, auto-reset OTP, fan-fail detection, 12 V / 0.3 A standby rail, and open-collector DC Good, AC Fail, and Dropped Phase signals.
- High-Reliability 3-Zone Isolation: Certified to IEC/UL/CSA/EN 62368-1 with 3000 VAC input-to-output, 2000 VAC input-to-ground, and 500 VDC output-to-ground dielectric withstand ratings.
- Ruggedized -40 °C to +70 °C Thermal Envelope: Supports -40 °C (-40 °F) cold startup, full 4500 W output to +50 °C (+122 °F), 4000 m altitude operation, and MIL-STD-810H shock and vibration compliance.
- Scalable Parallel & Series Expansion: Supports single-wire active current sharing for up to 8 units in parallel (derated to 90% power) or series connection for higher system bus voltages.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | TPS4500-92/184 |
| Alternate Part Number | TPS450092184 |
| Product Series | TPS4500 Series |
| Product Category | Chassis Power Supplies |
| Component Type | 3-Phase Industrial Chassis-Mount AC-DC Power Supply |
| Circuit Topology | 3-Phase Active PFC Switching AC-DC Converter (CV / CC Mode) |
| Nominal Output Voltage (Channel 1 / Channel 2) | 92 VDC / 184 VDC (Dual Output or Single Output Proportional Load Sharing) |
| Output Voltage Adjustment Range (Trim Potentiometer) | 57 to 99 VDC (92V Output) / 114 to 198 VDC (184V Output) |
| Output Voltage Adjustment Range (0–5V Analog Programming) | 56 to 96.5 VDC (92V Output) / 112 to 193 VDC (184V Output) |
| Output Voltage Adjustment Range (PMBus Digital) | 30 to 96.5 VDC (92V Output) / 60 to 193 VDC (184V Output) |
| Rated Output Current | 49 A (at 92 VDC) / 24.5 A (at 184 VDC) |
| Maximum Output Current (at Nominal Input) | 50 A (at 92 VDC) / 25 A (at 184 VDC) |
| Minimum Output Load Requirement | 0.5 A (required to maintain regulation and ripple specifications) |
| Rated Output Power | 4500 W |
| Maximum Output Power (at Nominal Line Voltage) | 4600 W |
| Dropped Phase Output Power Capacity | 2250 W (at 400 VAC) / 2925 W (at 480 VAC) |
| Output Ripple & Noise (Peak-to-Peak Max) | 2% pk-pk maximum |
| Line Regulation | < 0.25% |
| Load Regulation | < 0.5% (< 3% on unregulated output) |
| Total Output Regulation | < 1.75% |
| Cross Regulation | < 3% |
| Warm-Up Drift | < 0.25% |
| Temperature Stability | 0.05% of rated Vout over 8 hours (after 30-minute warm-up) |
| Temperature Coefficient | 200 ppm/°C |
| Hold-Up Time (at 400–480 VAC Nominal) | > 10 ms (at 80% of rated current, nominal input/output voltage) |
| Standby Auxiliary Output | 11.2 to 12.5 VDC, 0.3 A |
| Operating Input Voltage Range (3-Phase AC) | 360 to 528 VAC, 3-Phase Delta or Wye |
| Nominal Input Voltage Range | 400 to 480 VAC, 3-Phase Delta or Wye (Safety certified for 360–528 VAC) |
| Input Line Frequency | 47 to 63 Hz (Safety certified for 50 to 60 Hz) |
| AC Input Current (at Nominal 400–480 VAC) | 9 A per phase (steady state) |
| Inrush Current (Cold Start at 400–480 VAC) | < 25 A per phase (excluding initial filter capacitor charging < 2 ms) |
| Power Factor (at 400–480 VAC Nominal) | 0.92 typical (at rated load, nominal Vin) |
| Conversion Efficiency (Typical) | 93% |
| Overload / Overcurrent Protection (OLP) Threshold | Adjustable from 65% to > 100% of maximum rated current |
| Overload / Overcurrent Protection (OLP) Mode | Constant current limiting style (optional time-delayed shutdown with auto-restart available) |
| Overvoltage Protection (OVP) Threshold | 115% of output voltage set point (tracking) |
| Overvoltage Protection (OVP) Mode | Latched shutdown (cycle AC input or toggle remote on/off to reset) |
| Overtemperature Protection (OTP) Mode | Internal thermostat shutdown with automatic recovery |
| Fan Failure Protection | Blocked rotor or fan failure detection |
| Withstand Isolation Voltage (Input to Output) | 3000 VAC (1 minute) |
| Withstand Isolation Voltage (Input to Ground / Case) | 2000 VAC (1 minute) |
| Withstand Isolation Voltage (Output to Ground / Case) | 500 VDC (1 minute) |
| Isolation Resistance (at 500 VDC) | > 100 MΩ (at 25 °C, 70% RH) |
| Earth Leakage Current (RMS) | < 3 mA |
| Operating Ambient Temperature Range | -10 °C to +70 °C / +14 °F to +158 °F (-40 °C / -40 °F cold start-up with 10-min warm-up at 80% load) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% rated load |
| High-Temperature Derating Rate | Linear derating from 100% to 80% load (+50 °C to +60 °C), and 80% to 55% load (+60 °C to +70 °C) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 10% to 95% RH (non-condensing) |
| Pollution Degree | PD 2 |
| Maximum Operating Altitude | 4,000 m (13,123 ft) |
| Operating Vibration Compliance | Designed to meet MIL-STD-810H, Method 514.8, Procedure I, Category 1 & 10 |
| Mechanical Shock Compliance | Designed to meet MIL-STD-810H, Method 516.8, Procedures I, IV (Logistics) & VI |
| MTBF (Telcordia SR-332 Issue 3) | 250,000 hours (Method 1, Ground Benign, 25 °C, nominal input) |
| Safety Certifications (UL / CSA) | UL 62368-1, CSA C22.2 No. 62368-1 |
| Safety Certifications (IEC / EN / Regional) | IEC 62368-1, EN 62368-1, CE Mark, UKCA Mark |
| EMC Conducted & Radiated Emissions | EN 55032 Class A (conducted and radiated in end system; pair with RTMN-5020 filter) |
| EMC Line Dip Compliance | SEMI F47-0706 at 480 VAC nominal (Criteria B) |
| EMC Immunity — ESD (EN 61000-4-2) | ±8 kV air discharge, ±4 kV contact discharge |
| EMC Immunity — Radiated RF (EN 61000-4-3) | 3 V/m, 80 MHz to 1000 MHz (80% AM at 1 kHz) |
| EMC Immunity — EFT / Burst (EN 61000-4-4) | ±1 kV on AC power lines, ±0.5 kV on I/O signal lines |
| EMC Immunity — Surge (EN 61000-4-5) | ±2 kV common mode (3-phase), ±1 kV differential mode |
| EMC Immunity — Conducted RF (EN 61000-4-6) | 3 Vrms, 150 kHz to 80 MHz (1 kHz, 80% AM) |
| EMC Immunity — Magnetic Field (EN 61000-4-8) | 30 A/m and 300 A/m inductive loop at 50 Hz |
| EMC Immunity — Voltage Dips & Interruptions (EN 61000-4-11) | 30% voltage dip and >95% voltage dip/interruption |
| Communication & Telemetry Interface | PMBus / I2C (Vout, Iout, Temp monitoring; Remote On/Off, V/I programming, fault clearing, manufacturing data) |
| Analog Control Signals | 0–5 V external Voltage Programming (VADJ), 0–5 V Overcurrent Programming (IADJ), Remote On/Off (Enable/Inhibit selectable) |
| Status & Alarm Signals | Open Collector: DC Good (>90% Vout tracking), AC Fail (>340 VAC at >30% load), Dropped Phase Warning, OTW1/OTW2 |
| Parallel & Series Operation | Single-wire active current share up to 8 units (derate to 90% output power); series connection supported |
| LED Status Indicators | Green LEDs for AC ON and DC OK; blinking Red/Green during dropped phase (>30% load) |
| Input Terminal Pinout | 4-Pole Barrier Terminal Block: L1, L2, L3, GND |
| Output Terminal Pinout | Busbar / Terminal Block: V2 (184V), V1 (92V), RTN (0V) |
| Signal & PMBus Mating Connectors | Signal: JST PHDR-20VS housing with SPHD-001T-P0.5 crimp terminals; PMBus jumper: Samtec 2SN-BK-G |
| Cooling Method | Forced-air cooling via internal variable-speed fan |
| Form Factor & Mounting Style | 2U Low-Profile Enclosed Chassis Mount |
| Overall Width (W) | 107 mm (4.21 in) |
| Overall Height (H) | 85 mm (3.35 in) — 2U height |
| Overall Depth / Length (D/L) | 335 mm (13.2 in) excluding output connectors |
| Overall Dimensions (W × H × D) | 107 × 85 × 335 mm (4.21 × 3.35 × 13.2 in) |
| Net Weight | 4,000 g / 4.0 kg (8.82 lbs) |
| Manufacturer Warranty | 3 Years |
Industrial Applications & Compatible Systems
TDK-Lambda TPS4500-92/184 is purpose-built for high-power industrial automation, semiconductor processing, and distributed DC bus architectures requiring programmable constant-voltage/constant-current 92 VDC or 184 VDC power from 400–480 VAC 3-phase mains:
- Semiconductor Wafer Fabrication & Plasma Equipment: SEMI F47-0706 line-dip immunity and PMBus digital telemetry support RF generators, ion implanters, and vacuum chamber power stages.
- Industrial Laser Cutting, Additive Manufacturing & UV Curing: Fast 0–5 V analog or I2C/PMBus current-limit programming drives high-power diode laser arrays and solid-state curing banks.
- Automated Battery Formation, Cell Testing & EV Subsystems: Wide 30–193 VDC programmable CV/CC output enables precision multi-channel battery module charging and cycling racks.
- High-Voltage DC Microgrids & Industrial Robotics: Arbitrary dual-output load sharing across 92 V and 184 V buses powers multi-axis servo drives, electroplating baths, and test benches.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: Mount the 2U chassis (107 × 85 × 335 mm) with unobstructed airflow at the front and rear fan vents, maintaining at least 50 mm clearance so internal variable-speed cooling sustains 4500 W output up to +50 °C (+122 °F); above +50 °C, derate total load linearly at 2.0%/°C to 80% at +60 °C and 2.5%/°C to 55% at +70 °C. For sub-zero cold starts down to -40 °C, apply nominal 3-phase input and allow a 10-minute warm-up at 80% load before demanding full regulation. Protect each 3-phase leg (L1, L2, L3) with a D-curve 15 A–20 A 3-pole circuit breaker to accommodate 9 A steady-state current and <25 A cold-start inrush, and install a TDK-Lambda RTMN-5020 3-phase two-stage EMC filter upstream when EN 55032 Class A system compliance is required.