Description
XP Power ECL25US15-T (also known as ECL25US15T) is an ultra-compact 25 W single-output AC-DC power supply from the industrial ECL25 series, where the US15 nomenclature denotes a universal-input single 15.0 VDC output and the -T suffix specifies the open-frame chassis-mount mechanical configuration with onboard JST header connectors. Operating across a universal 85–264 VAC (47–63 Hz) or 120–370 VDC input range with a 70 kHz typical switching topology, it delivers a continuous 1.67 A nominal output current alongside a 2.17 A peak current capability (up to 32.5 W for <30 s at a maximum 10% duty cycle) to handle inductive startup surges. The unit achieves an 80% typical conversion efficiency and maintains eco-friendly standby performance with <0.3 W no-load power consumption. Output voltage is factory-set to ±1% initial accuracy with an onboard potentiometer allowing ±5% voltage trim (14.25–15.75 VDC), while holding line regulation within ±0.5% max, load regulation within 1% max without requiring a minimum load, and output ripple and noise below 120 mV pk-pk across a 20 MHz bandwidth.
Engineered for space-constrained OEM instrumentation and industrial control assemblies, the -T chassis-mount frame measures just 34.6 mm × 22.4 mm × 87.9 mm (1.36 in × 0.88 in × 3.46 in), weighs 66 g (0.14 lbs), and secures via four Ø3.81 mm (Ø0.15 in) corner mounting holes spaced at 81.3 mm × 27.9 mm (3.20 in × 1.10 in). Wire-to-board termination is streamlined via polarized headers that mate with a JST XHP-3 input housing and a JST XHP-6 output housing (compatible with SXH-002T-P0.6 crimps or the pre-assembled ECL25 LOOM KIT). Comprehensive internal safeguards include an integral T2 A / 250 VAC slow-blow input fuse, 115–140% Vnom overvoltage protection (OVP), 120–170% overload protection (OLP), and continuous hiccup-mode short-circuit protection (SCP) with automatic recovery. Built with Class II double-insulated construction (requiring no earth ground) and reinforced 3000 VAC input-to-output galvanic isolation, the convection-cooled supply operates from -20 °C to +70 °C (-4 °F to +158 °F)—delivering 100% rated power up to +50 °C (+122 °F)—and carries full UL/IEC/EN 62368-1, IEC 60950-1, and EN 55032 Class B certifications.
Key Features
- Continuous & Peak Power Delivery: Supplies 25 W continuous power (15.0 VDC at 1.67 A) and up to 2.17 A peak current (<30 s duration, 10% max duty cycle) to start solenoids, relays, and capacitive loads without over-sizing.
- Universal AC/DC Input & Eco Standby: Accepts 85–264 VAC (47–63 Hz) or 120–370 VDC worldwide inputs with 80% typical efficiency, drawing <0.3 W no-load standby power and only 0.4 A rms at 230 VAC.
- Precision Output & Fast Transient Recovery: Features ±1% initial voltage accuracy, ±5% onboard potentiometer trim (14.25–15.75 VDC), ±0.5% line regulation, 1% load regulation, 120 mV pk-pk max ripple, and <500 µs recovery for 25% load steps.
- Ultra-Compact Chassis-Mount Footprint: Open-frame -T configuration measures 34.6 × 22.4 × 87.9 mm (1.36 × 0.88 × 3.46 in) and weighs 66 g (0.14 lbs), integrating polarized headers for JST XHP-3 input and JST XHP-6 output plugs.
- 3000 VAC Class II Double Insulation: Eliminates safety earth wiring via Class II unearthed architecture while providing 3000 VAC input-to-output dielectric isolation and an onboard T2 A / 250 VAC slow-blow primary fuse.
- Self-Recovering Fault Protection Suite: Protects downstream electronics with 115–140% Vnom overvoltage protection, 120–170% total power overload limiting, and trip-and-restart hiccup-mode short-circuit protection.
- Wide Convection Thermal Envelope: Operates via natural air convection from -20 °C to +70 °C (-4 °F to +158 °F), sustaining 100% full-load output up to +50 °C (+122 °F) and derating linearly to 50% load at +70 °C.
- Global Safety & Class B EMC Compliance: Certified to UL 62368-1, CAN/CSA C22.2 No. 62368-1-14, IEC/EN 62368-1, and IEC 60950-1, while meeting EN 55032 Level B conducted/radiated emissions and EN 61000-4 immunity standards.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | ECL25US15-T |
| Alternate Part Number | ECL25US15T |
| Compatible Equipment / Series | XP Power ECL25 LOOM KIT (300 mm Wire Harness), ECL25/30 Series Industrial & ITE Subsystems |
| Product Series | ECL25 Series |
| Product Category | Open Frame PSUs |
| Component Type | Open-Frame Chassis-Mount AC-DC Switching Power Supply |
| Circuit Topology | Switched-Mode Power Supply (SMPS), Class II Double Insulated (No Earth Required) |
| Nominal Output Voltage | 15.0 VDC |
| Output Voltage Adjustment Range | 14.25 to 15.75 VDC (±5% via onboard V Adj. potentiometer) |
| Rated Output Current | 1.67 A |
| Output Current Range | 0 to 1.67 A (No minimum load required) |
| Peak / Surge Output Current | 2.17 A (130% nominal current for <30 s, max. 10% duty cycle, average power not to exceed 25 W) |
| Rated Output Power | 25 W |
| Peak Output Power | 32.5 W (<30 s duration, max. 10% duty cycle) |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 120 mV pk-pk (20 MHz bandwidth) |
| Output Voltage Tolerance | ±1% max. (Initial set accuracy) |
| Line Regulation | ±0.5% max. |
| Load Regulation | ±1.0% max. (0% to 100% load) |
| Transient Recovery Time & Deviation | 4% max. deviation, recovery to within 1% in 500 µs for a 25% load step change |
| Setup Time | 3 s max. (Start-up delay) |
| Rise Time | 14 ms max. (Start-up rise time) |
| Hold-Up Time (at 115 VAC) | 16 ms typical (at full load) |
| AC Input Voltage Range | 85 to 264 VAC |
| DC Input Voltage Range | 120 to 370 VDC |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency | 80% typical |
| AC Input Current (at 230 VAC) | 0.4 A rms |
| Inrush Current (Cold Start at 115 VAC) | 20 A (at +25 °C) |
| Inrush Current (Cold Start at 230 VAC) | 40 A (at +25 °C) |
| Power Factor Correction (PFC) | Passive compliance to EN 61000-3-2 Class A |
| No-Load Power Consumption | < 0.3 W |
| Switching Frequency | 70 kHz typical |
| Internal Input Fuse | T2 A / 250 VAC (Internal slow-blow fuse) |
| Mounting Style | Chassis Mount (Open-Frame PCB with 4 Corner Mounting Holes) |
| Cooling Method | Natural Air Convection (Free Air) |
| Overall Width (W) | 34.6 mm (1.36 in) |
| Overall Height (H) | 22.4 mm (0.88 in) max. |
| Overall Depth (D) | 87.9 mm (3.46 in) |
| Dimensional Tolerance | ±0.5 mm (±0.02 in) for 2-decimal inch / 1-decimal mm; ±0.25 mm (±0.01 in) for 3-decimal inch / 2-decimal mm |
| Mounting Hole Pitch | 81.3 × 27.9 mm (3.20 × 1.10 in) center-to-center; 4 × Ø3.81 mm (Ø0.15 in) mounting holes |
| Net Weight | 66 g (0.066 kg / 0.14 lbs / 2.33 oz) |
| Termination / Connector Style | Polarized Male Friction-Lock Pin Headers (Mates with JST XHP-3 Input & JST XHP-6 Output Housings using SXH-002T-P0.6 Crimps) |
| Input Terminal Pinout | 3-Position Input Header (Mates with JST XHP-3): ACL (AC Line), Center Key/Blank Spacing, ACN (AC Neutral) |
| Output & Signal Terminal Pinout | 6-Position Output Header (Mates with JST XHP-6): +Vo (Positive DC Output), -Vo (Negative DC Return); Onboard V Adj. Trim Potentiometer |
| Overload Protection (OLP) Threshold | 120% to 170% of rated total output power |
| Overload Protection (OLP) Mode | Trip and restart (Hiccup mode) with automatic recovery |
| Overvoltage Protection (OVP) Threshold | 115% to 140% of nominal output voltage (17.25 to 21.0 VDC) |
| Short Circuit Protection (SCP) | Continuous trip and restart (Hiccup mode) with automatic recovery upon fault removal |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC |
| Earth Leakage Current | None (Class II double-insulated construction with no earth connection) |
| Operating Ambient Temperature Range | -20 °C to +70 °C (-4 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% rated load (25 W) |
| High-Temperature Derating Rate | 2.5% per °C linear derating from 100% load at +50 °C (+122 °F) to 50% load (12.5 W) at +70 °C (+158 °F) |
| Altitude Derating | Up to 3000 m (9842 ft) max. operating altitude |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | Up to 95% RH (Non-condensing) |
| Temperature Coefficient | ±0.05% / °C |
| Vibration Resistance | 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins per axis |
| Safety Approvals (UL / North America) | UL 62368-1, CAN/CSA C22.2 No. 62368-1-14 |
| Safety Approvals (IEC / EN / TÜV) | IEC 62368-1:2014, EN 62368-1:2014/A11:2017, IEC 60950-1:2005 Ed 2, CE Marked |
| EMC Conducted & Radiated Emissions | EN 55032 Level B (Conducted and Radiated) |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker) |
| EMC Immunity Standards | EN 61000-4-2 (ESD Level 3, Criteria A), EN 61000-4-3 (Radiated 10 V/m 80% mod, Criteria A), EN 61000-4-4 (EFT/Burst Level 3, Criteria A), EN 61000-4-5 (Surge Installation Class 3, Criteria A), EN 61000-4-6 (Conducted 10 Vrms, Criteria A), EN 61000-4-8 (Magnetic Field 10 A/m, Criteria A), EN 61000-4-11 (Voltage Dips & Interruptions: 30% 10 ms Criteria A, 60% 100 ms Criteria B, 100% 5000 ms Criteria B) |
| MTBF (MIL-HDBK-217F) | > 400,000 Hours (at +25 °C / +77 °F, Ground Benign) |
| Environmental Compliance | RoHS Compliant, ErP / Eco-Design (<0.3 W No-Load Input Power) |
| Manufacturer Warranty | 3 Years |
Industrial Applications & Compatible Systems
The XP Power ECL25US15-T is engineered for space-critical industrial, commercial, and instrumentation architectures requiring a low-profile 15 VDC auxiliary power rail:
- Industrial Automation & Sensor Networks: Powers 15 V analog signal conditioners, 4–20 mA loop transmitters, optical encoders, and PLC expansion modules inside shallow control enclosures.
- Test, Measurement & Laboratory Instrumentation: Provides a tightly regulated, low-ripple (120 mV pk-pk) 15 VDC rail for operational amplifiers, data acquisition (DAQ) front-ends, and benchtop analyzers.
- Building Management & Security Systems: Supplies continuous 25 W power with 2.17 A peak surge capacity to drive motorized HVAC dampers, access control strikes, and environmental telemetry panels.
- Point-of-Sale (POS) & Kiosk Subsystems: Fits directly into non-metallic or unearthed enclosures thanks to Class II double-insulated construction and <0.3 W standby power consumption.
Installation, Thermal Management & MRO Guidelines
Follow these critical mechanical, electrical, and thermal engineering practices when integrating the ECL25US15-T into OEM equipment or MRO replacements:
- Wire Harness & JST Connector Mating: Terminate AC input wiring using a JST XHP-3 housing and DC output wiring using a JST XHP-6 housing fitted with SXH-002T-P0.6 crimp terminals, or order the factory-assembled ECL25 LOOM KIT (300 mm wire harness) for rapid plug-and-play installation.
- Chassis Clearance & Class II Creepage: Secure the PCB using the four Ø3.81 mm corner holes (81.3 × 27.9 mm pitch) on insulating standoffs; maintain adequate primary-to-chassis creepage and clearance beneath the open-frame board to preserve the 3000 VAC Class II isolation barrier.
- Convection Thermal Derating & Peak Duty Control: Allow unobstructed airflow around the open-frame components; apply the 2.5%/°C linear derating slope above +50 °C (+122 °F) down to 12.5 W max at +70 °C (+158 °F), and restrict 2.17 A peak load excursions to under 30 seconds at a maximum 10% duty cycle.