ECL25US15-T XP Power 25W 15VDC Open Frame Power Supply

$42.91

XP Power ECL25US15-T (ECL25US15T) 25W 15VDC 1.67A open-frame chassis-mount AC-DC power supply, 85-264VAC input, featuring 2.17A peak load and UL/IEC 62368-1.

SKU: ECL25US15-T Category: Brand:

Description

XP Power ECL25US15-T (also known as ECL25US15T) is an ultra-compact 25 W single-output AC-DC power supply from the industrial ECL25 series, where the US15 nomenclature denotes a universal-input single 15.0 VDC output and the -T suffix specifies the open-frame chassis-mount mechanical configuration with onboard JST header connectors. Operating across a universal 85–264 VAC (47–63 Hz) or 120–370 VDC input range with a 70 kHz typical switching topology, it delivers a continuous 1.67 A nominal output current alongside a 2.17 A peak current capability (up to 32.5 W for <30 s at a maximum 10% duty cycle) to handle inductive startup surges. The unit achieves an 80% typical conversion efficiency and maintains eco-friendly standby performance with <0.3 W no-load power consumption. Output voltage is factory-set to ±1% initial accuracy with an onboard potentiometer allowing ±5% voltage trim (14.25–15.75 VDC), while holding line regulation within ±0.5% max, load regulation within 1% max without requiring a minimum load, and output ripple and noise below 120 mV pk-pk across a 20 MHz bandwidth.

Engineered for space-constrained OEM instrumentation and industrial control assemblies, the -T chassis-mount frame measures just 34.6 mm × 22.4 mm × 87.9 mm (1.36 in × 0.88 in × 3.46 in), weighs 66 g (0.14 lbs), and secures via four Ø3.81 mm (Ø0.15 in) corner mounting holes spaced at 81.3 mm × 27.9 mm (3.20 in × 1.10 in). Wire-to-board termination is streamlined via polarized headers that mate with a JST XHP-3 input housing and a JST XHP-6 output housing (compatible with SXH-002T-P0.6 crimps or the pre-assembled ECL25 LOOM KIT). Comprehensive internal safeguards include an integral T2 A / 250 VAC slow-blow input fuse, 115–140% Vnom overvoltage protection (OVP), 120–170% overload protection (OLP), and continuous hiccup-mode short-circuit protection (SCP) with automatic recovery. Built with Class II double-insulated construction (requiring no earth ground) and reinforced 3000 VAC input-to-output galvanic isolation, the convection-cooled supply operates from -20 °C to +70 °C (-4 °F to +158 °F)—delivering 100% rated power up to +50 °C (+122 °F)—and carries full UL/IEC/EN 62368-1, IEC 60950-1, and EN 55032 Class B certifications.

Key Features

  • Continuous & Peak Power Delivery: Supplies 25 W continuous power (15.0 VDC at 1.67 A) and up to 2.17 A peak current (<30 s duration, 10% max duty cycle) to start solenoids, relays, and capacitive loads without over-sizing.
  • Universal AC/DC Input & Eco Standby: Accepts 85–264 VAC (47–63 Hz) or 120–370 VDC worldwide inputs with 80% typical efficiency, drawing <0.3 W no-load standby power and only 0.4 A rms at 230 VAC.
  • Precision Output & Fast Transient Recovery: Features ±1% initial voltage accuracy, ±5% onboard potentiometer trim (14.25–15.75 VDC), ±0.5% line regulation, 1% load regulation, 120 mV pk-pk max ripple, and <500 µs recovery for 25% load steps.
  • Ultra-Compact Chassis-Mount Footprint: Open-frame -T configuration measures 34.6 × 22.4 × 87.9 mm (1.36 × 0.88 × 3.46 in) and weighs 66 g (0.14 lbs), integrating polarized headers for JST XHP-3 input and JST XHP-6 output plugs.
  • 3000 VAC Class II Double Insulation: Eliminates safety earth wiring via Class II unearthed architecture while providing 3000 VAC input-to-output dielectric isolation and an onboard T2 A / 250 VAC slow-blow primary fuse.
  • Self-Recovering Fault Protection Suite: Protects downstream electronics with 115–140% Vnom overvoltage protection, 120–170% total power overload limiting, and trip-and-restart hiccup-mode short-circuit protection.
  • Wide Convection Thermal Envelope: Operates via natural air convection from -20 °C to +70 °C (-4 °F to +158 °F), sustaining 100% full-load output up to +50 °C (+122 °F) and derating linearly to 50% load at +70 °C.
  • Global Safety & Class B EMC Compliance: Certified to UL 62368-1, CAN/CSA C22.2 No. 62368-1-14, IEC/EN 62368-1, and IEC 60950-1, while meeting EN 55032 Level B conducted/radiated emissions and EN 61000-4 immunity standards.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) ECL25US15-T
Alternate Part Number ECL25US15T
Compatible Equipment / Series XP Power ECL25 LOOM KIT (300 mm Wire Harness), ECL25/30 Series Industrial & ITE Subsystems
Product Series ECL25 Series
Product Category Open Frame PSUs
Component Type Open-Frame Chassis-Mount AC-DC Switching Power Supply
Circuit Topology Switched-Mode Power Supply (SMPS), Class II Double Insulated (No Earth Required)
Nominal Output Voltage 15.0 VDC
Output Voltage Adjustment Range 14.25 to 15.75 VDC (±5% via onboard V Adj. potentiometer)
Rated Output Current 1.67 A
Output Current Range 0 to 1.67 A (No minimum load required)
Peak / Surge Output Current 2.17 A (130% nominal current for <30 s, max. 10% duty cycle, average power not to exceed 25 W)
Rated Output Power 25 W
Peak Output Power 32.5 W (<30 s duration, max. 10% duty cycle)
Number of Outputs 1 (Single Output)
Output Ripple & Noise (Max.) 120 mV pk-pk (20 MHz bandwidth)
Output Voltage Tolerance ±1% max. (Initial set accuracy)
Line Regulation ±0.5% max.
Load Regulation ±1.0% max. (0% to 100% load)
Transient Recovery Time & Deviation 4% max. deviation, recovery to within 1% in 500 µs for a 25% load step change
Setup Time 3 s max. (Start-up delay)
Rise Time 14 ms max. (Start-up rise time)
Hold-Up Time (at 115 VAC) 16 ms typical (at full load)
AC Input Voltage Range 85 to 264 VAC
DC Input Voltage Range 120 to 370 VDC
Input Frequency Range 47 to 63 Hz
Efficiency 80% typical
AC Input Current (at 230 VAC) 0.4 A rms
Inrush Current (Cold Start at 115 VAC) 20 A (at +25 °C)
Inrush Current (Cold Start at 230 VAC) 40 A (at +25 °C)
Power Factor Correction (PFC) Passive compliance to EN 61000-3-2 Class A
No-Load Power Consumption < 0.3 W
Switching Frequency 70 kHz typical
Internal Input Fuse T2 A / 250 VAC (Internal slow-blow fuse)
Mounting Style Chassis Mount (Open-Frame PCB with 4 Corner Mounting Holes)
Cooling Method Natural Air Convection (Free Air)
Overall Width (W) 34.6 mm (1.36 in)
Overall Height (H) 22.4 mm (0.88 in) max.
Overall Depth (D) 87.9 mm (3.46 in)
Dimensional Tolerance ±0.5 mm (±0.02 in) for 2-decimal inch / 1-decimal mm; ±0.25 mm (±0.01 in) for 3-decimal inch / 2-decimal mm
Mounting Hole Pitch 81.3 × 27.9 mm (3.20 × 1.10 in) center-to-center; 4 × Ø3.81 mm (Ø0.15 in) mounting holes
Net Weight 66 g (0.066 kg / 0.14 lbs / 2.33 oz)
Termination / Connector Style Polarized Male Friction-Lock Pin Headers (Mates with JST XHP-3 Input & JST XHP-6 Output Housings using SXH-002T-P0.6 Crimps)
Input Terminal Pinout 3-Position Input Header (Mates with JST XHP-3): ACL (AC Line), Center Key/Blank Spacing, ACN (AC Neutral)
Output & Signal Terminal Pinout 6-Position Output Header (Mates with JST XHP-6): +Vo (Positive DC Output), -Vo (Negative DC Return); Onboard V Adj. Trim Potentiometer
Overload Protection (OLP) Threshold 120% to 170% of rated total output power
Overload Protection (OLP) Mode Trip and restart (Hiccup mode) with automatic recovery
Overvoltage Protection (OVP) Threshold 115% to 140% of nominal output voltage (17.25 to 21.0 VDC)
Short Circuit Protection (SCP) Continuous trip and restart (Hiccup mode) with automatic recovery upon fault removal
Withstand Isolation Voltage (I/P to O/P) 3000 VAC
Earth Leakage Current None (Class II double-insulated construction with no earth connection)
Operating Ambient Temperature Range -20 °C to +70 °C (-4 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 100% rated load (25 W)
High-Temperature Derating Rate 2.5% per °C linear derating from 100% load at +50 °C (+122 °F) to 50% load (12.5 W) at +70 °C (+158 °F)
Altitude Derating Up to 3000 m (9842 ft) max. operating altitude
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity Up to 95% RH (Non-condensing)
Temperature Coefficient ±0.05% / °C
Vibration Resistance 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins per axis
Safety Approvals (UL / North America) UL 62368-1, CAN/CSA C22.2 No. 62368-1-14
Safety Approvals (IEC / EN / TÜV) IEC 62368-1:2014, EN 62368-1:2014/A11:2017, IEC 60950-1:2005 Ed 2, CE Marked
EMC Conducted & Radiated Emissions EN 55032 Level B (Conducted and Radiated)
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker)
EMC Immunity Standards EN 61000-4-2 (ESD Level 3, Criteria A), EN 61000-4-3 (Radiated 10 V/m 80% mod, Criteria A), EN 61000-4-4 (EFT/Burst Level 3, Criteria A), EN 61000-4-5 (Surge Installation Class 3, Criteria A), EN 61000-4-6 (Conducted 10 Vrms, Criteria A), EN 61000-4-8 (Magnetic Field 10 A/m, Criteria A), EN 61000-4-11 (Voltage Dips & Interruptions: 30% 10 ms Criteria A, 60% 100 ms Criteria B, 100% 5000 ms Criteria B)
MTBF (MIL-HDBK-217F) > 400,000 Hours (at +25 °C / +77 °F, Ground Benign)
Environmental Compliance RoHS Compliant, ErP / Eco-Design (<0.3 W No-Load Input Power)
Manufacturer Warranty 3 Years

Industrial Applications & Compatible Systems

The XP Power ECL25US15-T is engineered for space-critical industrial, commercial, and instrumentation architectures requiring a low-profile 15 VDC auxiliary power rail:

  • Industrial Automation & Sensor Networks: Powers 15 V analog signal conditioners, 4–20 mA loop transmitters, optical encoders, and PLC expansion modules inside shallow control enclosures.
  • Test, Measurement & Laboratory Instrumentation: Provides a tightly regulated, low-ripple (120 mV pk-pk) 15 VDC rail for operational amplifiers, data acquisition (DAQ) front-ends, and benchtop analyzers.
  • Building Management & Security Systems: Supplies continuous 25 W power with 2.17 A peak surge capacity to drive motorized HVAC dampers, access control strikes, and environmental telemetry panels.
  • Point-of-Sale (POS) & Kiosk Subsystems: Fits directly into non-metallic or unearthed enclosures thanks to Class II double-insulated construction and <0.3 W standby power consumption.

Installation, Thermal Management & MRO Guidelines

Follow these critical mechanical, electrical, and thermal engineering practices when integrating the ECL25US15-T into OEM equipment or MRO replacements:

  • Wire Harness & JST Connector Mating: Terminate AC input wiring using a JST XHP-3 housing and DC output wiring using a JST XHP-6 housing fitted with SXH-002T-P0.6 crimp terminals, or order the factory-assembled ECL25 LOOM KIT (300 mm wire harness) for rapid plug-and-play installation.
  • Chassis Clearance & Class II Creepage: Secure the PCB using the four Ø3.81 mm corner holes (81.3 × 27.9 mm pitch) on insulating standoffs; maintain adequate primary-to-chassis creepage and clearance beneath the open-frame board to preserve the 3000 VAC Class II isolation barrier.
  • Convection Thermal Derating & Peak Duty Control: Allow unobstructed airflow around the open-frame components; apply the 2.5%/°C linear derating slope above +50 °C (+122 °F) down to 12.5 W max at +70 °C (+158 °F), and restrict 2.17 A peak load excursions to under 30 seconds at a maximum 10% duty cycle.