3146450000 Weidmüller 72W 24VDC DIN Rail Power Supply

$136.50

Weidmüller 3146450000 PROeco II 72W 24VDC 3A DIN rail power supply, 85-264VAC/110-370VDC input, featuring SNAP IN terminals, 3-color LED, and cULus approvals.

SKU: 3146450000 Category: Brand:

Description

Weidmüller 3146450000 is a second-generation PROeco II industrial single-phase DIN rail switch-mode power supply engineered for high-availability factory automation and process control systems. Identified by its OEM type designation PRO ECO 72W 24V 3A II SI (GTIN 4099987579391), the nomenclature decodes directly to a 72 W rated power core, a regulated 24 VDC nominal output at 3 A continuous current up to 55 °C, Second Generation (II) architecture, and lever-actuated SNAP IN (SI) spring connection technology. It accepts a universal 85 to 264 VAC (45–65 Hz) or 110 to 370 VDC wide-range input and achieves up to 87.5% typical efficiency at 230 VAC with only 3 W idling power loss and 12 W full-load dissipation. Output voltage is front-panel adjustable from 22 to 28 VDC via an integrated potentiometer, maintaining tight 1% line regulation, 2% load regulation, and low residual ripple below 50 mVpp (20 MHz bandwidth) while supporting unrestricted capacitive loads and parallel operation of up to 3 units.

Housed in a slim, corrosion-resistant metal enclosure measuring 32 mm (1.26 in) wide, 130 mm (5.12 in) high, and 100 mm (3.94 in) deep for TS 35 DIN rail mounting, the unit streamlines cabinet wiring with tool-free SNAP IN terminals on the 3-pole input (L, N, PE) and 4-pole output (++ / –) alongside a 2-pole PUSH IN floating relay contact (terminals 13/14). Visual diagnostics and proactive maintenance are supported by a three-color status LED (green for healthy output >90%, yellow for >90% current overload pre-warning, and red for fault <=85% Vout) synchronized with the dry NO status relay. Comprehensive protection covers overload, short-circuit, over-temperature, internal input fuse, varistor surge suppression, and 30–35 VDC reverse voltage feedback immunity, backed by reinforced 4 kV AC input-to-output galvanic isolation. Operating reliably across -25 °C to +70 °C (-13 °F to +158 °F) with cold start-up down to -40 °C and linear derating above 55 °C (delivering 1.875 A at 70 °C), it holds full cULus (E258476), cURus (E255651), IEC/EN 61010-1 SELV/PELV, EN 61558-2-16, and EN 55032 Class B compliance.

Key Features

  • Ultra-Fast SNAP IN & PUSH IN Termination: Equipped with innovative SNAP IN spring terminals for 20–12 AWG (0.5–4.0 mm²) input/output power wiring and PUSH IN terminals for 28–14 AWG signal wiring, slashing cabinet installation time and resisting vibration.
  • Regulated 24 VDC / 3 A Output with Parallel Capability: Delivers 72 W continuous power (3 A up to 55 °C; 1.875 A at 70 °C) with a 22–28 VDC potentiometer adjustment range, <50 mVpp ripple, unrestricted capacitive load drive, and parallel support up to 3 units.
  • Wide Universal AC & DC Input Range: Operates seamlessly from 85 to 264 VAC (45–65 Hz) or 110 to 370 VDC supply buses, achieving 87.5% typical efficiency at 230 VAC and >124 ms mains failure hold-up time.
  • Three-Color Diagnostic LED & Status Relay: Combines a tri-state visual indicator (Green OK >90% Vout, Yellow overload pre-warning >90% Inom, Red fault <=85% Vout) with a floating NO relay contact (terminals 13/14, 30 VDC / 1 A) for PLC telemetry.
  • Compact 32 mm Corrosion-Resistant Metal Housing: Space-saving 32 x 130 x 100 mm (1.26 x 5.12 x 3.94 in) IP20 metal chassis mounts directly onto TS 35 DIN rails and fits shallow decentralized field enclosures.
  • Reinforced 4 kV Isolation & Comprehensive Protection: Provides 4 kV I/P-to-O/P and 3 kV I/P-to-PE dielectric strength, Class I PE grounding, overload, short-circuit, over-temperature protection, and 30–35 VDC reverse feedback voltage immunity.
  • Wide Industrial Thermal & Mechanical Resilience: Engineered for -25 °C to +70 °C operation with cold start-up from -40 °C, tested to 30 g shock (IEC 60068-2-27) and 0.7 g vibration (IEC 60068-2-6) for heavy industrial machinery.
  • Global Safety & Class B EMC Certifications: Certified to cULus (E258476), cURus (E255651), IEC 61010-1/2-201 (SELV/PELV), EN 60204, EN 61558-2-16, EN 55032 Class B emissions, and full EN 61000-4 industrial immunity suites.

Technical Specifications

Manufacturer Weidmüller
Manufacturer Part Number (MPN) 3146450000
OEM Cross-Reference / Replaced Part PRO ECO 72W 24V 3A II SI (Type Designation) / GTIN (EAN): 4099987579391
Compatible Equipment / Series Weidmüller PROeco DC UPS, Electronic Load Monitoring (PRO MAX / maxGUARD), Diode Redundancy Modules, TS 35 End Brackets WEW 35/1 (1478990000) & WEW 35/2 (1479000000), Mounting Flange MTA 30 BK (1168970000)
Product Series PROeco II (2nd Generation)
Product Category Single-Phase DIN Rail
Component Type Industrial AC-DC DIN Rail Switch-Mode Power Supply
Circuit Topology Switched-Mode Power Supply (SMPS), Regulated Primary-Switched Flyback/Forward Architecture
Nominal Output Voltage 24 VDC
Output Voltage Adjustment Range 22 to 28 VDC (adjustable via front-panel potentiometer)
Rated Output Current 3 A (at 24 VDC up to 55 °C) / 1.875 A (continuous at 70 °C)
Rated Output Power 72 W
Number of Outputs 1 Output (4 Output Terminals: ++ / –)
Output Ripple & Noise (Max.) < 50 mVpp (20 MHz bandwidth)
Line Regulation 1% (typical)
Load Regulation 2% (typical)
Setup Time <= 1000 ms (1 s max. start-up time)
Rise Time <= 100 ms (ramp-up time)
Hold-Up Time (at 115 VAC) Min. 27 ms (> 25 ms typical at 120 VAC, 24 VDC / 3 A full load)
Hold-Up Time (at 230 VAC) Min. 124 ms (> 120 ms typical at 230 VAC, 24 VDC / 3 A full load)
Max. Capacitive Load Unrestricted
AC Input Voltage Range 85 to 264 VAC (derating below 100 VAC)
DC Input Voltage Range 110 to 370 VDC (derating below 120 VDC)
Nominal Input Voltage 100 to 240 VAC / 120 to 340 VDC (Apparent Power Consumption: 82.8 VA)
Input Frequency Range 45 to 65 Hz
Efficiency (at 115 VAC) 83.5% (typical at 120 VAC)
Efficiency (at 230 VAC) 87.5% (typical at 230 VAC, 12 W nominal load power loss)
AC Input Current (at 115 VAC) 1.33 A (at 100 VAC)
AC Input Current (at 230 VAC) 0.69 A (at 240 VAC)
DC Input Current (Full Load / No Load) 0.73 A (at 120 VDC) / 0.26 A (at 370 VDC)
Inrush Current 35 A (typical, 115 / 230 VAC)
Power Factor (PF at 115 VAC) 0.50 (typical at 120 VAC, 25 °C, 72 W)
Power Factor (PF at 230 VAC) 0.45 (typical at 230 VAC, 25 °C, 72 W)
No-Load Power Consumption 3 W (idling power loss)
Mounting Style DIN Rail TS 35 (EN 60715)
Cooling Method Free Air Natural Convection
Overall Width (W) 32 mm (1.26 in / 1.2598 in)
Overall Height (H) 130 mm (5.12 in / 5.1181 in)
Overall Depth (D) 100 mm (3.94 in / 3.937 in)
Net Weight 420 g (0.93 lbs / 14.82 oz)
Termination / Connector Style SNAP IN Lever-Actuated Spring Connection (Input & Output) / PUSH IN Spring Connection (Status Relay Signal)
Input Terminal Pinout 3-Pole SNAP IN Terminal Block: L (Line / +), N (Neutral / -), PE (Protective Earth); Recommended External Backup Fuse: 2 A DI Safety Fuse, 6 A Char. B MCB, or 2–4 A Char. C MCB
Output & Signal Terminal Pinout Output (4-Pole SNAP IN): ++ (Positive 24 VDC), — (Negative GND), Parallelizable up to 3 units; Signal (2-Pole PUSH IN): Terminals 13 & 14 (Floating NO Relay Contact)
Control & Monitoring Signals Floating Status Relay (NO Contact, Terminals 13–14, Max. 30 VDC / 1 A): Closed when Vout > 90% of set voltage; Opened on Fault when Vout <= 85% of set voltage
Status Indicator Three-Color Front LED: Green (Fault-free operation, Vout > 90%), Yellow (Overload pre-warning, Iout > 90% Inom ±5% & Vout > 90%), Red (Fault, Vout <= 85%)
Terminal Wire Gauge Range Input & Output (SNAP IN): 20–12 AWG (0.5–4.0 mm² flexible, 0.5–2.5 mm² rigid, 9 mm strip length); Signal (PUSH IN): 28–14 AWG (0.2–1.5 mm² solid/flexible, 8 mm strip length)
Enclosure / Potting Material Corrosion-Resistant Sheet Metal Housing
Overload Protection (OLP) Mode Yes (Continuous current limiting with Yellow LED pre-warning at > 90% Inom)
Overvoltage Protection (OVP) Threshold 30 to 35 VDC (Protection against reverse voltages from the load)
Overtemperature Protection (OTP) Mode Yes (Automatic thermal shutdown and recovery)
Short Circuit Protection (SCP) Yes (Continuous short-circuit proof)
Reverse Polarity Protection Yes (Protection against inverse voltage and 30–35 VDC load backfeed)
Withstand Isolation Voltage (I/P to O/P) 4.0 kV AC (4000 VAC, Protection Class I with PE, Overvoltage Category II, Pollution Severity 2)
Withstand Isolation Voltage (I/P to FG / Case) 3.0 kV AC (3000 VAC Input to Earth)
Withstand Isolation Voltage (O/P to FG / Case) 0.5 kV AC (500 VAC Output to Earth)
Earth Leakage Current Max. 3.5 mA
Operating Ambient Temperature Range -25 °C to +70 °C (-13 °F to +158 °F), Cold Start-Up >= -40 °C (-40 °F)
Full-Load Operating Temperature Limit +55 °C (+131 °F) at full 3 A / 72 W load
High-Temperature Derating Rate 2.5% per °C (0.075 A/°C) linear derating from +55 °C to +70 °C (1.875 A / 45 W continuous at +70 °C)
Low-Line Input Derating Derating required below 100 VAC (down to 85 VAC) and below 120 VDC (down to 110 VDC) per datasheet curve
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 5% to 95% RH (non-condensing)
Vibration Resistance 0.7 g Vibration (acc. to IEC 60068-2-6) / 30 g Shock in all directions (acc. to IEC 60068-2-27)
Ingress Protection (IP) IP20
Safety Approvals (UL / North America) cULus Listed (File E258476), cURus Recognized (File E255651)
Safety Approvals (IEC / EN / TÜV) IEC/EN 61010-1 (SELV), IEC/EN 61010-2-201 (PELV), EN 61558-2-16 (Safety Transformers for SMPS), EN 60204 (Electrical Machine Equipment)
EMC Conducted & Radiated Emissions EN 55032 Class B, IEC 61000-6-3, IEC 61000-6-4
EMC Harmonic & Flicker Compliance EN 61000-3-2 (Harmonic Current Emissions)
EMC Immunity Standards EN 61000-4-2 (ESD), EN 61000-4-3 (Radiated RF), EN 61000-4-4 (EFT/Burst), EN 61000-4-5 (Surge, Internal Varistor), EN 61000-4-6 (Conducted RF), EN 61000-4-8 (Magnetic Fields), EN 61000-4-11 (Voltage Dips & Interruptions), IEC 61000-6-1, IEC 61000-6-2
Environmental Compliance RoHS Compliant (with Exemption 6c, 7a, 7cI), REACH SVHC Declared (SCIP: cc530c6d-a7ac-41ec-a2b4-caa3b47dbe25), ETIM 8.0/9.0/10.0: EC002540, ECLASS 14.0/15.0: 27-04-07-01

Industrial Applications & Compatible Systems

The Weidmüller 3146450000 (PRO ECO 72W 24V 3A II SI) is purpose-built for decentralized industrial automation, compact machine control cabinets, and high-reliability 24 VDC power distribution architectures.

  • PLC, Distributed I/O & Fieldbus Cabinets: Supplies tightly regulated 24 VDC (up to 3 A) with <50 mVpp ripple to programmable logic controllers, remote I/O islands (Weidmüller u-remote), industrial Ethernet switches, and HMI panels in shallow field enclosures.
  • High-Vibration Automated Machinery & Robotics: Leverages tool-free SNAP IN spring clamping and 30 g shock / 0.7 g vibration resistance to maintain gas-tight electrical connections on packaging lines, CNC machinery, and material handling conveyors.
  • Redundant & Buffered 24 VDC Power Management Systems: Integrates directly with Weidmüller DC UPS modules, diode redundancy blocks, and electronic load monitoring (maxGUARD) with up to 3 power supplies connected in parallel for N+1 availability or 216 W capacity.
  • Process Telemetry & Predictive Maintenance Panels: Utilizes the built-in three-color status LED (with >90% load yellow pre-warning) and floating NO relay contact (terminals 13/14) to feed real-time power health diagnostics into SCADA and plant monitoring systems.

Installation, Thermal Management & MRO Guidelines

To maximize service life and operational reliability of the PROeco II 72 W power supply, observe the following engineering and installation best practices.

  • SNAP IN & PUSH IN Conductor Preparation: Strip input and output power conductors (20–12 AWG / 0.5–4.0 mm² flexible or 0.5–2.5 mm² rigid) to exactly 9 mm before inserting into the SNAP IN ports until the lever clicks shut; strip signal wires (28–14 AWG / 0.2–1.5 mm²) to 8 mm for the PUSH IN relay terminal.
  • Upstream Branch Protection & Inrush Coordination: Protect the AC input line using an external 2 A DI safety fuse, a 6 A Characteristic B circuit breaker, or a 2–4 A Characteristic C circuit breaker sized to ride through the 35 A typical cold-start inrush pulse.
  • Thermal Convection & High-Temperature Derating: Mount vertically on a horizontal TS 35 DIN rail secured with Weidmüller WEW 35/1 or WEW 35/2 end brackets; provide adequate top/bottom convection clearance and derate continuous load current linearly from 3.0 A at +55 °C down to 1.875 A at +70 °C (and derate below 100 VAC or 120 VDC input).