Description
Weidmüller 2838450000 (Type: PRO BAS 120W 12V 10A) is a single-phase switch-mode DIN rail power supply engineered for compact industrial control cabinets requiring stable 12 V DC bus power. Delivering 120 W continuous output power and 10 A rated current up to +55 °C, the unit accepts a wide universal input of 85–264 V AC (45–65 Hz) or 110–370 V DC while maintaining 90% conversion efficiency at 230 V AC. Its front-panel potentiometer allows precise output voltage adjustment from 9 V to 16 V DC to compensate for cable voltage drops, while residual ripple and breaking spikes stay tightly suppressed below 50 mVpp at full load.
Comprehensive internal protection safeguards against short circuits, overloads, over-temperature conditions, and inverse output voltages, complemented by a floating normally-open (NO) DC OK relay contact rated up to 30 V DC / 1 A and a green status LED. Reinforced 3.5 kV galvanic isolation between input-to-output and input-to-earth ensures high dielectric safety across a -25 °C to +70 °C operating temperature window with cold start-up capability down to -40 °C. Housed in a slim 40 mm (1.575 in) wide protective-insulated plastic enclosure for snap-on TS35 DIN rail mounting with zero side-by-side clearance, the supply complies with IEC 61010-1, IEC 61010-2-201, EN 61558-2-16, EN 50178, and EN 55032 Class B EMC standards.
Key Features
- High-Density 120 W Output & Wide Adjustment: Delivers 12 V DC nominal at 10 A (120 W) up to +55 °C, with an adjustable 9–16 V DC output range and ultra-low ≤ 50 mVpp residual ripple.
- Universal AC & DC Input Compatibility: Operates across 85–264 V AC (45–65 Hz) and 110–370 V DC with an internal input fuse and 90% efficiency at 230 V AC to minimize cabinet heat dissipation.
- Ultra-Slim 40 mm Zero-Spacing Footprint: Compact 40 × 130 × 100 mm (1.575 × 5.118 × 3.937 in) housing mounts directly on TS35 DIN rails with 0 mm side-by-side spacing to maximize panel density.
- Comprehensive Fault Protection & Parallel Capability: Integrates automatic short-circuit, overload, over-temperature, and inverse-voltage protection, plus parallel operation support for up to 3 power supplies.
- Remote Status Signalling & Diagnostics: Equipped with a front green LED indicator and a potential-free floating NO relay contact (max 30 V DC / 1 A) for PLC monitoring of output voltage OK status.
- Reinforced 3.5 kV Isolation & Cold Start: Features 3.5 kV input-to-output and input-to-earth insulation coordination, -40 °C cold start-up capability, and 30 g mechanical shock resistance per IEC 60068-2-27.
- Industrial Safety & Class B EMC Compliance: Certified to IEC 61010-1, IEC 61010-2-201, EN 61558-2-16, EN 50178, CE, UKCA, and EN 55032 Class B conducted and radiated noise emission limits.
Technical Specifications
| Manufacturer | Weidmüller |
|---|---|
| Manufacturer Part Number (MPN) | 2838450000 |
| Type Designation | PRO BAS 120W 12V 10A |
| GTIN / EAN | 4064675444145 |
| Product Series | PRObas Series |
| Product Category | Single-Phase DIN Rail |
| Component Type | Switch-Mode DIN Rail Power Supply Unit (AC-DC / DC-DC) |
| ETIM Classification | EC002540 (ETIM 6.0 / 7.0 / 8.0) |
| eCl@ss Classification | 27-04-07-01 (eCl@ss 9.0 / 9.1 / 10.0 / 11.0 / 12.0) |
| Nominal Output Voltage | 12 V DC |
| Output Voltage Adjustment Range | 9 V DC to 16 V DC (Front Potentiometer) |
| Rated Output Current (at +55 °C) | 10 A |
| Derated Continuous Output Current (at +70 °C) | 6.25 A |
| Rated Output Power | 120 W |
| Residual Ripple & Breaking Spikes | ≤ 50 mVpp (at Full Load) |
| Max. Capacitive Load | 5.5 mF (5,500 µF) |
| Parallel Operation Capability | Yes, up to 3 Units Maximum |
| Mains Failure Bridge-Over / Hold-Up Time (at 115/120 VAC) | Min. 20 ms (> 20 ms at 115 V AC, 10 A) |
| Mains Failure Bridge-Over / Hold-Up Time (at 230 VAC) | Min. 40 ms (> 80 ms typical at 230 V AC, 10 A) |
| Rated Input Voltage (AC) | 110 V AC to 240 V AC |
| Operating Input Voltage Range (AC) | 85 V AC to 264 V AC (Derating below 100 V AC) |
| Rated Input Voltage (DC) | 120 V DC to 340 V DC |
| Operating Input Voltage Range (DC) | 110 V DC to 370 V DC (Derating below 120 V DC) |
| Input AC Frequency Range | 45 Hz to 65 Hz |
| Degree of Efficiency (at 230 VAC) | 90% |
| AC Input Current (at 115 VAC) | 2.04 A |
| AC Input Current (at 230 VAC) | 1.14 A |
| DC Input Current (at 120 VDC) | 1.12 A |
| Cold-Start Inrush Current (at 230 VAC, +25 °C) | 40 A |
| Power Factor (at 120 VAC) | Approx. 0.50 |
| Power Factor (at 230 VAC) | Approx. 0.51 |
| No-Load / Idling Power Loss | 1.2 W |
| Nominal Load Power Loss | 15.4 W |
| Internal Input Fuse | Yes (Integrated) |
| Recommended Upstream Back-Up Fuse / Breaker | 4 A DI Safety Fuse / 6 A Char. B MCB / 2–4 A Char. C MCB |
| Overload Protection (OLP) | Yes (Integrated Electronic Current Limiting) |
| Short-Circuit Protection (SCP) | Yes (Continuous Short-Circuit Proof) |
| Over-Temperature Protection (OTP) | Yes (Thermal Shutdown Protection) |
| Reverse / Inverse Voltage Protection | Yes (Integrated Output Back-Feed Protection) |
| Protection Class | Class I (with PE Protective Earth Connection) |
| Withstand Isolation Voltage (Input to Output) | 3.5 kV |
| Withstand Isolation Voltage (Input to Earth / PE) | 3.5 kV |
| Withstand Isolation Voltage (Output to Earth / PE) | 0.5 kV (500 V) |
| Earth Leakage Current (Max.) | 3.5 mA |
| Pollution Degree | 2 |
| Operating Ambient Temperature Range | -25 °C to +70 °C (-13 °F to +158 °F) |
| Minimum Cold Start-Up Temperature | ≥ -40 °C (-40 °F) |
| Full-Load Operating Temperature Limit | +55 °C (+131 °F) at 100% Rated Load (10 A) |
| High-Temperature Derating Rate | 2.5% / °C above +55 °C (Down to 62.5% / 6.25 A at +70 °C) |
| Low-Line AC Input Derating | Linear Derating from 100% at 100 V AC down to 80% at 85 V AC |
| Low-Line DC Input Derating | Linear Derating from 100% at 120 V DC down to 90% at 110 V DC |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating & Storage Relative Humidity | 5% to 95% RH (Non-Condensing) |
| Shock Resistance (IEC 60068-2-27) | 30 g in All Directions |
| Vibration Resistance (IEC 60068-2-6 / EN 50178) | 0.7 g |
| EMC Noise Emission Standard (EN 55032) | EN 55032 Class B (Conducted & Radiated Emissions) |
| Safety Standard — Control Equipment (IEC 61010) | IEC 61010-1, IEC 61010-2-201 |
| Safety Standard — Switch-Mode Transformers (EN 61558) | EN 61558-2-16 (Safety Extra-Low Voltage / SELV) |
| Safety Standard — Electronic Equipment (EN 50178) | EN 50178 |
| Regional Conformity Declarations | CE (EU Declaration of Conformity), UKCA |
| Status Indication LED | Green LED (Operating Voltage OK) |
| DC OK Signalling Output Type | Potential-Free Floating Normally-Open (NO) Relay Contact |
| DC OK Relay Contact Rating | Max. 30 V DC / 1 A |
| Input Connection System | Screw Connection Terminals |
| Output Connection System & Terminal Count | Screw Connection, 4 Output Terminals (++ / –) |
| Conductor Cross-Section (Rigid Solid) | 0.5 mm² to 6 mm² (Input & Output) |
| Conductor Cross-Section (Flexible Stranded) | 0.5 mm² to 6 mm² (Input & Output) |
| Wire Gauge Range (AWG / kcmil) | 26 AWG to 12 AWG (Input & Output) |
| Cooling Method | Natural Free Air Convection (Fanless) |
| Mounting Style & Orientation | Horizontal Snap-On Mounting on TS35 DIN Rail |
| Required Ventilation Clearance | 50 mm (1.97 in) Top & Bottom; 0 mm Side-by-Side |
| Overall Width (W) | 40 mm (1.575 in) |
| Overall Height (H) | 130 mm (5.118 in) |
| Overall Depth (D) | 100 mm (3.937 in) |
| Overall Dimensions (W × H × D) | 40 × 130 × 100 mm (1.575 × 5.118 × 3.937 in) |
| Net Weight | 490 g (1.08 lbs / 17.28 oz) |
| Housing Material & Insulation | Industrial Plastic Enclosure, Protective Insulation |
| Environmental Compliance | RoHS Compliant |
Industrial Applications & Compatible Systems
Weidmüller 2838450000 provides a rugged, space-saving 12 V DC / 10 A power bus for industrial automation panels, electronic fuse systems, and distributed control architectures:
- Industrial Control Cabinets & PLC Subsystems: Supplies low-ripple 12 V DC power to programmable logic controllers, remote I/O racks, HMIs, and industrial sensors in high-density TS35 DIN rail enclosures.
- Intelligent Power Management & Redundancy Systems: Seamlessly pairs with Weidmüller electronic circuit breakers, diode redundancy modules, and DC UPS backup units to build fault-tolerant 12 V DC distribution networks.
- Factory Automation & Packaging Machinery: Endures 30 g mechanical shock and 0.7 g vibration on assembly lines, conveyor drives, and automated material-handling equipment.
- Building Management, HVAC & Security Controls: Fits narrow 40 mm wall-mounted sub-panels for access control systems, fire/alarm panels, solenoid valves, and telemetry gateways.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: Mount the unit horizontally onto a standard 35 mm TS35 DIN rail and maintain at least 50 mm (1.97 in) of unobstructed vertical clearance above and below the housing for natural convection cooling; adjacent PRObas supplies may be mounted with 0 mm side-by-side gap. For ambient temperatures exceeding +55 °C (+131 °F), derate the continuous output load linearly at 2.5% per °C down to 6.25 A (75 W) at +70 °C (+158 °F), and apply low-line derating below 100 V AC or 120 V DC. Protect the AC mains feed with a 6 A Characteristic B or 2–4 A Characteristic C miniature circuit breaker (or 4 A DI safety fuse) to accommodate the 40 A cold-start inrush current, and terminate input/output conductors using 0.5–6 mm² (26–12 AWG) copper wire.