2838450000 Weidmüller 120W 12VDC DIN Rail Power Supply

$109.34

Weidmüller 2838450000 PRO BAS 120W 12VDC 10A DIN rail power supply, 85–264VAC input, 90% efficiency, featuring 3.5kV isolation, DC OK relay.

SKU: 2838450000 Category: Brand:

Description

Weidmüller 2838450000 (Type: PRO BAS 120W 12V 10A) is a single-phase switch-mode DIN rail power supply engineered for compact industrial control cabinets requiring stable 12 V DC bus power. Delivering 120 W continuous output power and 10 A rated current up to +55 °C, the unit accepts a wide universal input of 85–264 V AC (45–65 Hz) or 110–370 V DC while maintaining 90% conversion efficiency at 230 V AC. Its front-panel potentiometer allows precise output voltage adjustment from 9 V to 16 V DC to compensate for cable voltage drops, while residual ripple and breaking spikes stay tightly suppressed below 50 mVpp at full load.

Comprehensive internal protection safeguards against short circuits, overloads, over-temperature conditions, and inverse output voltages, complemented by a floating normally-open (NO) DC OK relay contact rated up to 30 V DC / 1 A and a green status LED. Reinforced 3.5 kV galvanic isolation between input-to-output and input-to-earth ensures high dielectric safety across a -25 °C to +70 °C operating temperature window with cold start-up capability down to -40 °C. Housed in a slim 40 mm (1.575 in) wide protective-insulated plastic enclosure for snap-on TS35 DIN rail mounting with zero side-by-side clearance, the supply complies with IEC 61010-1, IEC 61010-2-201, EN 61558-2-16, EN 50178, and EN 55032 Class B EMC standards.

Key Features

  • High-Density 120 W Output & Wide Adjustment: Delivers 12 V DC nominal at 10 A (120 W) up to +55 °C, with an adjustable 9–16 V DC output range and ultra-low ≤ 50 mVpp residual ripple.
  • Universal AC & DC Input Compatibility: Operates across 85–264 V AC (45–65 Hz) and 110–370 V DC with an internal input fuse and 90% efficiency at 230 V AC to minimize cabinet heat dissipation.
  • Ultra-Slim 40 mm Zero-Spacing Footprint: Compact 40 × 130 × 100 mm (1.575 × 5.118 × 3.937 in) housing mounts directly on TS35 DIN rails with 0 mm side-by-side spacing to maximize panel density.
  • Comprehensive Fault Protection & Parallel Capability: Integrates automatic short-circuit, overload, over-temperature, and inverse-voltage protection, plus parallel operation support for up to 3 power supplies.
  • Remote Status Signalling & Diagnostics: Equipped with a front green LED indicator and a potential-free floating NO relay contact (max 30 V DC / 1 A) for PLC monitoring of output voltage OK status.
  • Reinforced 3.5 kV Isolation & Cold Start: Features 3.5 kV input-to-output and input-to-earth insulation coordination, -40 °C cold start-up capability, and 30 g mechanical shock resistance per IEC 60068-2-27.
  • Industrial Safety & Class B EMC Compliance: Certified to IEC 61010-1, IEC 61010-2-201, EN 61558-2-16, EN 50178, CE, UKCA, and EN 55032 Class B conducted and radiated noise emission limits.

Technical Specifications

Manufacturer Weidmüller
Manufacturer Part Number (MPN) 2838450000
Type Designation PRO BAS 120W 12V 10A
GTIN / EAN 4064675444145
Product Series PRObas Series
Product Category Single-Phase DIN Rail
Component Type Switch-Mode DIN Rail Power Supply Unit (AC-DC / DC-DC)
ETIM Classification EC002540 (ETIM 6.0 / 7.0 / 8.0)
eCl@ss Classification 27-04-07-01 (eCl@ss 9.0 / 9.1 / 10.0 / 11.0 / 12.0)
Nominal Output Voltage 12 V DC
Output Voltage Adjustment Range 9 V DC to 16 V DC (Front Potentiometer)
Rated Output Current (at +55 °C) 10 A
Derated Continuous Output Current (at +70 °C) 6.25 A
Rated Output Power 120 W
Residual Ripple & Breaking Spikes ≤ 50 mVpp (at Full Load)
Max. Capacitive Load 5.5 mF (5,500 µF)
Parallel Operation Capability Yes, up to 3 Units Maximum
Mains Failure Bridge-Over / Hold-Up Time (at 115/120 VAC) Min. 20 ms (> 20 ms at 115 V AC, 10 A)
Mains Failure Bridge-Over / Hold-Up Time (at 230 VAC) Min. 40 ms (> 80 ms typical at 230 V AC, 10 A)
Rated Input Voltage (AC) 110 V AC to 240 V AC
Operating Input Voltage Range (AC) 85 V AC to 264 V AC (Derating below 100 V AC)
Rated Input Voltage (DC) 120 V DC to 340 V DC
Operating Input Voltage Range (DC) 110 V DC to 370 V DC (Derating below 120 V DC)
Input AC Frequency Range 45 Hz to 65 Hz
Degree of Efficiency (at 230 VAC) 90%
AC Input Current (at 115 VAC) 2.04 A
AC Input Current (at 230 VAC) 1.14 A
DC Input Current (at 120 VDC) 1.12 A
Cold-Start Inrush Current (at 230 VAC, +25 °C) 40 A
Power Factor (at 120 VAC) Approx. 0.50
Power Factor (at 230 VAC) Approx. 0.51
No-Load / Idling Power Loss 1.2 W
Nominal Load Power Loss 15.4 W
Internal Input Fuse Yes (Integrated)
Recommended Upstream Back-Up Fuse / Breaker 4 A DI Safety Fuse / 6 A Char. B MCB / 2–4 A Char. C MCB
Overload Protection (OLP) Yes (Integrated Electronic Current Limiting)
Short-Circuit Protection (SCP) Yes (Continuous Short-Circuit Proof)
Over-Temperature Protection (OTP) Yes (Thermal Shutdown Protection)
Reverse / Inverse Voltage Protection Yes (Integrated Output Back-Feed Protection)
Protection Class Class I (with PE Protective Earth Connection)
Withstand Isolation Voltage (Input to Output) 3.5 kV
Withstand Isolation Voltage (Input to Earth / PE) 3.5 kV
Withstand Isolation Voltage (Output to Earth / PE) 0.5 kV (500 V)
Earth Leakage Current (Max.) 3.5 mA
Pollution Degree 2
Operating Ambient Temperature Range -25 °C to +70 °C (-13 °F to +158 °F)
Minimum Cold Start-Up Temperature ≥ -40 °C (-40 °F)
Full-Load Operating Temperature Limit +55 °C (+131 °F) at 100% Rated Load (10 A)
High-Temperature Derating Rate 2.5% / °C above +55 °C (Down to 62.5% / 6.25 A at +70 °C)
Low-Line AC Input Derating Linear Derating from 100% at 100 V AC down to 80% at 85 V AC
Low-Line DC Input Derating Linear Derating from 100% at 120 V DC down to 90% at 110 V DC
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating & Storage Relative Humidity 5% to 95% RH (Non-Condensing)
Shock Resistance (IEC 60068-2-27) 30 g in All Directions
Vibration Resistance (IEC 60068-2-6 / EN 50178) 0.7 g
EMC Noise Emission Standard (EN 55032) EN 55032 Class B (Conducted & Radiated Emissions)
Safety Standard — Control Equipment (IEC 61010) IEC 61010-1, IEC 61010-2-201
Safety Standard — Switch-Mode Transformers (EN 61558) EN 61558-2-16 (Safety Extra-Low Voltage / SELV)
Safety Standard — Electronic Equipment (EN 50178) EN 50178
Regional Conformity Declarations CE (EU Declaration of Conformity), UKCA
Status Indication LED Green LED (Operating Voltage OK)
DC OK Signalling Output Type Potential-Free Floating Normally-Open (NO) Relay Contact
DC OK Relay Contact Rating Max. 30 V DC / 1 A
Input Connection System Screw Connection Terminals
Output Connection System & Terminal Count Screw Connection, 4 Output Terminals (++ / –)
Conductor Cross-Section (Rigid Solid) 0.5 mm² to 6 mm² (Input & Output)
Conductor Cross-Section (Flexible Stranded) 0.5 mm² to 6 mm² (Input & Output)
Wire Gauge Range (AWG / kcmil) 26 AWG to 12 AWG (Input & Output)
Cooling Method Natural Free Air Convection (Fanless)
Mounting Style & Orientation Horizontal Snap-On Mounting on TS35 DIN Rail
Required Ventilation Clearance 50 mm (1.97 in) Top & Bottom; 0 mm Side-by-Side
Overall Width (W) 40 mm (1.575 in)
Overall Height (H) 130 mm (5.118 in)
Overall Depth (D) 100 mm (3.937 in)
Overall Dimensions (W × H × D) 40 × 130 × 100 mm (1.575 × 5.118 × 3.937 in)
Net Weight 490 g (1.08 lbs / 17.28 oz)
Housing Material & Insulation Industrial Plastic Enclosure, Protective Insulation
Environmental Compliance RoHS Compliant

Industrial Applications & Compatible Systems

Weidmüller 2838450000 provides a rugged, space-saving 12 V DC / 10 A power bus for industrial automation panels, electronic fuse systems, and distributed control architectures:

  • Industrial Control Cabinets & PLC Subsystems: Supplies low-ripple 12 V DC power to programmable logic controllers, remote I/O racks, HMIs, and industrial sensors in high-density TS35 DIN rail enclosures.
  • Intelligent Power Management & Redundancy Systems: Seamlessly pairs with Weidmüller electronic circuit breakers, diode redundancy modules, and DC UPS backup units to build fault-tolerant 12 V DC distribution networks.
  • Factory Automation & Packaging Machinery: Endures 30 g mechanical shock and 0.7 g vibration on assembly lines, conveyor drives, and automated material-handling equipment.
  • Building Management, HVAC & Security Controls: Fits narrow 40 mm wall-mounted sub-panels for access control systems, fire/alarm panels, solenoid valves, and telemetry gateways.

Installation, Thermal Management & MRO Guidelines

Installation & Engineering Guidelines: Mount the unit horizontally onto a standard 35 mm TS35 DIN rail and maintain at least 50 mm (1.97 in) of unobstructed vertical clearance above and below the housing for natural convection cooling; adjacent PRObas supplies may be mounted with 0 mm side-by-side gap. For ambient temperatures exceeding +55 °C (+131 °F), derate the continuous output load linearly at 2.5% per °C down to 6.25 A (75 W) at +70 °C (+158 °F), and apply low-line derating below 100 V AC or 120 V DC. Protect the AC mains feed with a 6 A Characteristic B or 2–4 A Characteristic C miniature circuit breaker (or 4 A DI safety fuse) to accommodate the 40 A cold-start inrush current, and terminate input/output conductors using 0.5–6 mm² (26–12 AWG) copper wire.