Description
XP Power CU20-00 (also known as CU2000) is an ultra-compact, low-profile 15W open-frame AC-DC power supply from the CU20 series, where the -00 suffix designates the 3.3 VDC single-output configuration. Operating across a universal 85–264 VAC (120–370 VDC) input range at 67 kHz typical switching frequency, it delivers a continuous rated output of 3.3 VDC at 4.40 A with a 6.60 A peak load capability for up to 30 seconds at a 10% maximum duty cycle. Achieving 70% typical efficiency at 230 VAC full load, the module maintains tight regulation with ±0.5% maximum line regulation, ±1.0% maximum load regulation, ±5% output voltage trim adjustment, and low 50 mV pk-pk maximum ripple and noise without requiring any minimum load.
Engineered for space-constrained embedded electronics, the CU20-00 features a compact PCB footprint measuring 88.90 × 50.80 × 20.32 mm (3.50 × 2.00 × 0.80 in) and weighing just 60 g (0.220 lb), utilizing Molex 09-50-3031 input and 90-50-3041 output friction-lock headers. Comprehensive built-in protection includes hiccup-mode short-circuit protection with automatic recovery, latching 130–150% overvoltage protection, an integrated 2 A input fuse, and reinforced 3000 VAC input-to-output galvanic isolation. Convection-cooled across a 0 °C to +65 °C operating temperature range (full load up to +45 °C) and 3000 m operating altitude, it carries full UL 62368-1, EN 62368-1, CE, UKCA, and EN 55032 Class B conducted emissions compliance.
Key Features
- Precision 3.3 VDC Output & Peak Current: Delivers 15W continuous output at 3.3 VDC (4.40 A) with 6.60 A peak load capability for up to 30 seconds at 10% duty cycle.
- Universal AC & High-Voltage DC Input: Accepts 85–264 VAC (47–63 Hz) or 120–370 VDC inputs with 0.25 A rms input current at 230 VAC and integrated 2 A input fuse protection.
- Low-Noise & Tightly Regulated Output: Restricts output ripple and noise to 50 mV pk-pk maximum (20 MHz bandwidth) alongside ±0.5% line regulation, ±1.0% load regulation, and ±5% voltage trim.
- Ultra-Compact Low-Profile Footprint: Fits dense chassis and OEM enclosures with a 88.90 × 50.80 × 20.32 mm (3.50 × 2.00 × 0.80 in) open-frame PCB achieving 3.91 W/in³ power density.
- 3000 VAC Reinforced Galvanic Isolation: Provides 3000 VAC input-to-output, 1500 VAC input-to-ground, and 500 VAC output-to-ground dielectric withstand isolation with less than 1.5 mA earth leakage current.
- Hiccup Short-Circuit & Overvoltage Protection: Safeguards downstream 3.3 V logic rails via automatic trip-and-restart hiccup short-circuit protection and latching 130–150% overvoltage shutdown.
- Global ITE Safety & Class B EMC Compliance: Certified to UL 62368-1, EN 62368-1, CE, and UKCA standards with EN 55032 Class B and FCC Part 15 Level B conducted emissions.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | CU20-00 |
| Alternate Part Number | CU2000 |
| Product Series | CU20 Series |
| Product Category | Open Frame PSUs |
| Component Type | Open-Frame AC-DC Power Supply |
| Nominal Output Voltage | 3.3 VDC |
| Output Voltage Adjustment Range | ±5% (via onboard V Adj. potentiometer) |
| Rated Output Current | 4.40 A |
| Peak / Surge Output Current | 6.60 A (<30 s duration, max. 10% duty cycle) |
| Rated Output Power | 15 W |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 50 mV pk-pk (measured at 20 MHz bandwidth) |
| Output Voltage Tolerance | ±1% (initial set accuracy); ±0.6% drift |
| Line Regulation | ±0.5% max. |
| Load Regulation | ±1.0% max. |
| Transient Recovery Time & Deviation | 500 µs (to within 1% for 25% load step; 4% max. deviation) |
| Setup Time | 1.5 s max. (start-up delay) |
| Rise Time | 14 ms max. |
| Hold-Up Time (at 115 VAC) | 16 ms typical (at full load) |
| AC Input Voltage Range | 85–264 VAC |
| DC Input Voltage Range | 120–370 VDC |
| Input Frequency Range | 47–63 Hz |
| Efficiency | 70% typical (measured at 230 VAC & 100% load) |
| AC Input Current (at 230 VAC) | 0.25 A rms |
| Inrush Current (Cold Start at 115 VAC) | 20 A (at +25 °C) |
| Inrush Current (Cold Start at 230 VAC) | 40 A (at +25 °C) |
| Switching Frequency | 67 kHz typical |
| Mounting Style | Chassis / PCB Standoff Mount (4 × Ø 3.30 mm / 0.13 in mounting holes) |
| Cooling Method | Free Air Convection |
| Overall Width (W) | 50.80 mm (2.00 in) |
| Overall Height (H) | 20.32 mm (0.80 in) |
| Overall Depth (D) | 88.90 mm (3.50 in) |
| Mounting Hole Pitch | 81.28 × 43.18 mm (3.20 × 1.70 in) |
| Net Weight | 60 g (0.220 lb) |
| Termination / Connector Style | Molex PCB Friction-Lock Headers (0.150 in / 3.81 mm pitch) |
| Input Terminal Pinout | Input Header (mates with Molex 09-50-3031 & 2878 crimp terminals): Pin 1 = Line (L), Pin 2 = No Pin, Pin 3 = Neutral (N) |
| Output & Signal Terminal Pinout | Output Header (mates with Molex 90-50-3041 & 2878 crimp terminals): Pins 1–2 = +Vout, Pins 3–4 = -Vout |
| Overvoltage Protection (OVP) Threshold | 130%–150% of Vnom |
| Overvoltage Protection (OVP) Mode | Latching shutdown (recycle AC input to reset) |
| Short Circuit Protection (SCP) | Trip and restart (Hiccup mode, auto-recovery) |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC |
| Withstand Isolation Voltage (I/P to FG / Case) | 1500 VAC |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VAC |
| Earth Leakage Current | < 1.5 mA |
| Operating Ambient Temperature Range | 0 °C to +65 °C (+32 °F to +149 °F) |
| Full-Load Operating Temperature Limit | +45 °C (+113 °F) |
| High-Temperature Derating Rate | Linearly derate from 100% load at +45 °C to 0% load at +65 °C (5.0%/°C) |
| Storage Temperature Range | -20 °C to +85 °C (-4 °F to +185 °F) |
| Operating Relative Humidity | 95% RH max. (non-condensing) |
| Temperature Coefficient | ±0.05%/°C |
| Vibration Resistance | 10 Hz to 500 Hz, 2 g for 10 mins/cycle (60 min each axis) |
| Safety Approvals (UL / North America) | UL 62368-1 |
| Safety Approvals (IEC / EN / TÜV) | EN 62368-1 |
| Safety Approvals (Regional / Global) | CE, UKCA |
| EMC Conducted & Radiated Emissions | EN 55032 Class B (Conducted), FCC 20780 Level B |
| EMC Immunity Standards | EN 61000-4-2 Level 3 (Perf. Criteria A), EN 61000-4-3 Level 3 (Perf. Criteria A), EN 61000-4-4 Level 2 (Perf. Criteria A), EN 61000-4-5 Level 3 (Perf. Criteria A), EN 61000-4-6 10 V (Perf. Criteria A), EN 61000-4-11 (30% 10 ms, 60% 1000 ms, 100% 5000 ms; Perf. Criteria A, B, B) |
| MTBF (MIL-HDBK-217F) | > 500,000 hours |
Industrial Applications & Compatible Systems
The XP Power CU20-00 provides a low-profile, low-noise 3.3 VDC auxiliary and logic supply tailored for compact industrial and commercial electronics:
- Embedded Microcontroller & FPGA Systems: Powers 3.3 VDC processor cores, digital I/O logic banks, and industrial communication transceivers inside space-restricted control enclosures.
- Test, Measurement & Bench Instrumentation: Supplies clean, tightly regulated 3.3 VDC rails with 50 mV pk-pk ripple limits for sensitive data acquisition boards and sensor front-ends.
- Point-of-Sale & Self-Service Kiosks: Delivers 4.40 A continuous and 6.60 A peak current for barcode scanners, thermal receipt printers, and embedded payment terminals.
- Building Automation & Security Panels: Integrates directly into access control controllers, HVAC gateways, and alarm panels requiring Class B conducted emissions and universal AC input.
Installation, Thermal Management & MRO Guidelines
Follow these mechanical, thermal, and wiring guidelines when integrating the open-frame module into end equipment:
- Thermal Derating & Airflow Clearance: Maintain unobstructed natural convection around the PCB and derate output load linearly from 100% (15 W) at +45 °C down to 0% at +65 °C; note that adding the optional CU20 COVER (102 × 64 × 34 mm, suffix -C) encloses the unit for touch safety.
- Chassis Standoff & Creepage Spacing: Mount the board using all four 3.30 mm (0.13 in) corner holes on insulating or grounded standoffs while preserving mandatory primary-to-secondary creepage and clearance distances to adjacent metal chassis walls.
- Mating Harness & Connector Assembly: Terminate input wiring with Molex housing 09-50-3031 and output wiring with Molex housing 90-50-3041 using Molex 2878 series crimp terminals, or order XP Power accessory kits CU20-60 CONKIT (connectors) or CU20 LOOM KIT (300 mm pre-wired harnesses).
- Upstream Circuit Protection: Although the unit includes an internal 2 A input fuse, size upstream branch circuit breakers to tolerate 20 A (at 115 VAC) or 40 A (at 230 VAC) cold-start inrush currents without nuisance tripping.