Description
Omron S8VK-G03024-400 (also known as S8VKG03024400) is an industrial 30W single-phase DIN rail switch-mode power supply from the globally recognized S8VK-G series. Decoded directly from Omron factory nomenclature, the G designates single-phase universal input, 030 specifies the 30W power rating, 24 indicates the 24 VDC nominal output, and the -400 suffix denotes factory-applied PCB conformal coating for enhanced resistance against humidity, dust, and corrosive industrial atmospheres. It accepts a wide 85 to 264 VAC (47 to 450 Hz) or 90 to 350 VDC input (plus two-phase operation up to 240 VAC +10%) to deliver a tightly regulated 24 VDC at 1.3 A continuous current and a 1.56 A (120%) Power Boost current for transient motor or solenoid startups. Operating at a high 86% typical efficiency (at 230 VAC), the unit maintains an ultra-low output ripple and noise floor of 30 mVp-p max. (20 MHz bandwidth) alongside tight 0.4% max. line regulation and 0.8% max. load regulation.
Housed in an ultra-slim 32 x 90 x 90 mm (1.26 x 3.54 x 3.54 in) IP20 convection-cooled enclosure weighing just 195 g (6.88 oz) max., the unit snaps directly onto standard TS-35 DIN rails and wires via reliable screw terminals with a front-panel V.ADJ potentiometer (-10% to +15%) and green DC ON status LED. Comprehensive self-protection includes automatic-reset overload protection (>121% intermittent mode) and latching overvoltage shut-off (>=130% of Vout). It provides reinforced three-zone dielectric isolation rated at 3.0 kVAC (input to output), 2.0 kVAC (input to PE), and 1.0 kVAC (output to PE), and operates across an extended -40 °C to +70 °C (-40 °F to +158 °F) ambient temperature window. The power supply carries full UL 508 Listed (UL 1310 Class 2 output), UL/EN 62368-1, EN 50178, EN 60204-1 PELV, SEMI F47-0706, Lloyd’s Register marine, and EN 61204-3 / EN 55011 Class B EMI approvals.
Key Features
- Conformal Coated -400 Variant: Factory-applied protective PCB coating shields internal circuitry against moisture condensation, airborne particulates, and harsh industrial contaminants in demanding control cabinet environments.
- 120% Dynamic Power Boost: Delivers 1.3 A continuous current at 24 VDC with 1.56 A (37.4 W) peak boost capacity for up to 10 seconds (30% max. duty cycle) to handle inductive inrush loads.
- Universal AC, DC & 2-Phase Input: Operates seamlessly across 85 to 264 VAC (47 to 450 Hz), 90 to 350 VDC backup buses, and two-phase 200 to 240 VAC industrial distribution networks.
- Ultra-Low 30 mVp-p Output Ripple: Precision switching regulation restricts output ripple and noise to 30 mVp-p maximum across a 20 MHz bandwidth, ensuring clean power for sensitive analog PLC I/O and sensors.
- Wide -40 °C to +70 °C Thermal Window: Supports cold startups down to -40 °C and continuous full-load operation up to +55 °C in standard vertical DIN rail mounting before high-temperature derating.
- UL 1310 Class 2 & SEMI F47 Certified: Meets NEC Class 2 limited-energy safety requirements alongside UL 508, UL/EN 62368-1, EN 61558-2-16, Lloyd’s Register marine standards, and SEMI F47 voltage sag immunity.
- Flexible Series, Parallel & Redundant Modes: Supports series connection for dual/bipolar rails and parallel operation up to two units (or N+1 redundancy with Omron S8VK-R redundancy modules).
- 3.0 kVAC Galvanic Isolation & 10-Year Life: Engineered with 3.0 kVAC primary-to-secondary dielectric strength, >100 mΩ insulation resistance, 580,000-hour reference MTBF, and a 10-year minimum electrolytic capacitor design life.
Technical Specifications
| Manufacturer | Omron |
|---|---|
| Manufacturer Part Number (MPN) | S8VK-G03024-400 |
| Alternate Part Number | S8VKG03024400 |
| OEM Cross-Reference / Replaced Part | S8VK-G03024 (Standard Uncoated Base Version) |
| Compatible Equipment / Series | Omron S8V-CP Electronic Circuit Protectors, S8VK-R Redundancy Modules, S8V-NF Noise Filters, PFP-100N / PFP-50N DIN Rails, S82Y-VS10F / S82Y-VS10S Mounting Brackets |
| Product Series | S8VK-G Series |
| Product Category | Single-Phase DIN Rail |
| Component Type | Industrial AC-DC DIN Rail Switch-Mode Power Supply (Conformal Coated) |
| Circuit Topology | Isolated Switch-Mode Power Supply (SMPS) |
| Nominal Output Voltage | 24 VDC |
| Output Voltage Adjustment Range | 21.6 to 27.6 VDC (-10% to +15% guaranteed via front-panel V.ADJ trimmer) |
| Rated Output Current | 1.3 A |
| Output Current Range | 0 to 1.3 A continuous (up to 1.56 A boost) |
| Peak / Surge Output Current | 1.56 A (120% Power Boost for <= 10 s max., <= 30% duty cycle, average current <= 1.3 A) |
| Rated Output Power | 30 W (31.2 W continuous at 24 VDC / 1.3 A) |
| Peak Output Power | 37.4 W (120% Power Boost at 24 VDC / 1.56 A) |
| Number of Outputs | 1 (Single Output; dual +V and -V terminal pairs) |
| Output Ripple & Noise (Max.) | 30 mVp-p max. (at 20 MHz bandwidth, 100 to 240 VAC input, 100% load, -25 to +70 °C) |
| Line Regulation | 0.4% max. (Input variation influence across allowable input voltage range at rated output) |
| Load Regulation | 0.8% max. (Load variation influence from 0 A to 1.3 A rated output current at 100 to 240 VAC) |
| Setup Time (at 115 VAC) | 600 ms typ. (Cold start at 25 °C, full load) |
| Setup Time (at 230 VAC) | 480 ms typ. (Cold start at 25 °C, full load) |
| Hold-Up Time (at 115 VAC) | 23 ms typ. (at 25 °C, full load) |
| Hold-Up Time (at 230 VAC) | 154 ms typ. (at 25 °C, full load) |
| AC Input Voltage Range | 85 to 264 VAC (Single-phase or 2-phase up to 240 VAC +10% with external N-line fuse/breaker) |
| DC Input Voltage Range | 90 to 350 VDC (Requires external 350 VDC min., 4 A DC safety fuse) |
| Nominal Input Voltage | 100 to 240 VAC |
| Input Frequency Range | 47 to 450 Hz (50 / 60 Hz nominal) |
| Efficiency (at 230 VAC) | 86% typ. (at rated 24 VDC / 1.3 A load) |
| AC Input Current (at 115 VAC) | 0.58 A typ. (at 100% rated load) |
| AC Input Current (at 230 VAC) | 0.36 A typ. (at 100% rated load) |
| Inrush Current (Cold Start at 115 VAC) | 16 A typ. (at 25 °C cold start) |
| Inrush Current (Cold Start at 230 VAC) | 32 A typ. (at 25 °C cold start) |
| Power Factor (PF at 230 VAC) | 0.43 min. (at 100% rated load) |
| Mounting Style | DIN Rail TS-35 (Standard Vertical or Face-Up Horizontal; Optional Chassis Front/Side Brackets S82Y-VS10F / S82Y-VS10S) |
| Cooling Method | Natural Free Air Convection (Fanless) |
| Overall Width (W) | 32 mm (1.26 in) |
| Overall Height (H) | 90 mm (3.54 in) |
| Overall Depth (D) | 90 mm (3.54 in) |
| Dimensional Tolerance | ±1 mm (±0.039 in) |
| Net Weight | 195 g max. (0.43 lbs / 6.88 oz max.) |
| Termination / Connector Style | Finger-Safe Screw Terminal Blocks with Hinged Terminal Cover (7.62 mm pitch; 2.7 x 2.9 mm wire insertion hole) |
| Input Terminal Pinout | Bottom Terminal Block: AC(L) [Positive for DC Input, Internal 250 VAC 4.0 A HBC Fuse], AC(N), PE (Protective Earth) |
| Output & Signal Terminal Pinout | Top Terminal Block: 2x (+V) Positive DC Output Terminals, 2x (-V) Negative DC Output Terminals |
| Status Indicator | Green LED (DC ON: illuminates at >= 80% to 90% of rated output voltage; flashes during overload protection) |
| Terminal Wire Gauge Range | Input: AWG 24 to 12 (0.25 to 4 mm² solid / 0.25 to 2.5 mm² stranded); Output: AWG 22 to 12 (0.35 to 4 mm² solid / 0.35 to 2.5 mm² stranded); PE: AWG 14 to 12 (2.5 to 4 mm²); Strip Length: 8 to 10 mm |
| Terminal Tightening Torque | 0.5 to 0.6 N·m (4.43 to 5.31 lb-in) using #1 Phillips/Slotted screwdriver (3.5 mm max. shaft diameter) |
| Enclosure / Potting Material | Vented Industrial Enclosure with Factory Conformal Coated PCB (-400 Option) |
| Overload Protection (OLP) Threshold | > 121% of rated output current |
| Overload Protection (OLP) Mode | Intermittent operation (hiccup mode) with automatic recovery upon fault removal |
| Overvoltage Protection (OVP) Threshold | >= 130% of rated output voltage (approx. 31.2 VDC) |
| Overvoltage Protection (OVP) Mode | Output shut-off latch mode (recycle AC/DC input power OFF for at least 3 minutes to reset) |
| Short Circuit Protection (SCP) | Continuous intermittent current limiting with automatic recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3.0 kVAC for 1 minute (20 mA cutoff current) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2.0 kVAC for 1 minute (20 mA cutoff current) |
| Withstand Isolation Voltage (O/P to FG / Case) | 1.0 kVAC for 1 minute (20 mA cutoff current) |
| Isolation Resistance (at 500 VDC) | 100 mΩ min. (between all output terminals and all input/PE terminals) |
| Earth Leakage Current | 0.13 mA typ. (at 115 VAC) / 0.24 mA typ. (at 230 VAC) |
| Operating Ambient Temperature Range | -40 °C to +70 °C (-40 °F to +158 °F) with no condensation or icing |
| Full-Load Operating Temperature Limit | +55 °C (+131 °F) in Standard Vertical Mounting; +40 °C (+104 °F) in Face-Up Mounting |
| High-Temperature Derating Rate | Standard Vertical Mounting: Derates linearly from 100% load at +55 °C to 60% load at +70 °C (2.67%/°C); Face-Up Mounting: Derates from 80% load at +40 °C to 50% load at +55 °C; DC Input: Multiply load curve by 0.9 coefficient |
| Low-Line Input Derating | 2.5% per Volt below 90 VAC (85 to 90 VAC input range) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) with no condensation or icing |
| Operating Relative Humidity | 0% to 95% RH (non-condensing) |
| Storage Relative Humidity | 0% to 95% RH (non-condensing) |
| Temperature Coefficient | 0.05%/°C max. (115 to 230 VAC input) |
| Vibration Resistance | 10 to 55 Hz, 0.375 mm half-amplitude for 2 hours each in X, Y, and Z directions; Shock: 150 m/s², 3 times each in ±X, ±Y, ±Z |
| Ingress Protection (IP) | IP20 (per EN / IEC 60529) |
| Safety Approvals (UL / North America) | UL 508 Listed (Class 2 Output per UL 1310), UL 62368-1 Recognized (UR), cUL CSA C22.2 No. 107.1 (Class 2 Output per CSA C22.2 No. 223), cUR CSA C22.2 No. 62368-1 |
| Safety Approvals (IEC / EN / TÜV) | EN/VDE: EN 50178, EN 62368-1, EN 60204-1 (PELV), EN 61558-2-16 (Safety of Power Transformers) |
| Safety Approvals (Regional / Global) | Lloyd’s Register Marine Approved (with TDK ZCAT2035-0930 clamp filter & Schaffner FN2080-10-06 input filter), SEMI F47-0706 (200 to 240 VAC), EAC (TR CU 004/2011, TR CU 020/2011), RCM (EN 61000-6-4) |
| EMC Conducted & Radiated Emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B |
| EMC Harmonic & Flicker Compliance | Conforms to EN 61000-3-2 |
| EMC Immunity Standards | Conforms to EN 61204-3 High Severity Industrial Immunity Levels & SEMI F47-0706 Voltage Sag Immunity |
| MTBF (MIL-HDBK-217F) | 135,000 hours min. guaranteed (580,000 hours reference value; 10-year min. design life expectancy at 40 °C and 50% load) |
| Environmental Compliance | CE Marked, Conformal Coated PCB (-400 Suffix), 5-Year Factory Warranty |
Industrial Applications & Compatible Systems
The Omron S8VK-G03024-400 is purpose-built for harsh industrial automation panels, marine switchboards, and NEC Class 2 control circuits requiring moisture-resistant 24 VDC power.
- Harsh Environment PLC & Remote I/O Cabinets: Powers compact PLCs, distributed EtherCAT/PROFINET I/O slices, and HMIs in humid, dusty, or corrosive wastewater, food-processing, and chemical plants utilizing its -400 conformal coated PCB.
- UL 1310 Class 2 Sensor & Actuator Networks: Supplies NEC Class 2 current-limited 24 VDC power to photoelectric sensors, proximity switches, barcode readers, and pneumatic solenoid manifolds without requiring secondary branch fuses.
- Semiconductor Fab & Process Tooling: Certified to SEMI F47-0706 (at 200 to 240 VAC) with a 154 ms typical hold-up time at 230 VAC to ride through AC line voltage sags on wafer-handling and cleanroom automation equipment.
- Marine & Shipboard Control Consoles: Approved to Lloyd’s Register marine standards (when paired with specified Schaffner FN2080-10-06 line filter and TDK ZCAT2035-0930 ferrite clamp) for vessel bridge and engine-room instrumentation.
Installation, Thermal Management & MRO Guidelines
Ensure optimal service life and thermal stability by following Omron factory mounting, wiring, and protection guidelines during cabinet integration.
- Convection Clearance & Derating Management: Maintain at least 20 mm (0.79 in) vertical clearance above and below the power supply for natural air convection, derating output load above +55 °C (+131 °F) in standard vertical mounting or multiplying load capacity by 0.9x when operating from a 90 to 350 VDC input bus.
- Power Boost & Parallel/Redundant Wiring: Limit 120% (1.56 A) Power Boost events to 10 seconds maximum at a 30% duty cycle while keeping average current at or below 1.3 A; when paralleling two units for increased current or N+1 backup, match output voltages within 50 mV and decouple via an Omron S8VK-R redundancy module.
- Two-Phase & DC Input Fuse Protection: Because the internal 250 VAC 4.0 A HBC fuse is located exclusively on the AC(L) line, always install an external fuse or circuit breaker on the AC(N) terminal when operating across two phases of a 200 to 240 VAC three-phase system, or fit an external 350 VDC min. 4 A fuse for DC inputs.