GST60A12-P1M Mean Well 60W 12VDC Desktop Power Adapter

$60.00

Mean Well GST60A12-P1M (GST60A12P1M) 60W 12VDC 5A desktop power adapter, 90-264VAC IEC320-C14 Class I input, featuring 5.5×2.5mm P1M plug, DoE Level VI.

SKU: GST60A12-P1M Category: Brand:

Description

Mean Well GST60A12-P1M (also known as GST60A12P1M) is an industrial-grade 60W single-output green desktop power adapter from the GST60A series (safety model GST60A12). Decoding its nomenclature, GST60 denotes the 60W reliable green desktop family, A specifies the Class I 3-pole IEC320-C14 AC inlet with functional ground (FG), 12 indicates the 12 VDC nominal output, and the -P1M suffix designates the factory-terminated 5.5 × 2.5 × 11.0 mm straight tuning-fork DC coaxial plug (center positive). Operating across a universal 90 to 264 VAC (47–63 Hz) input range, the unit delivers 0 to 5 A continuous current with 89.5% typical efficiency and ultra-low no-load power consumption below 0.075 W. Output stability is strictly maintained within ±3.0% voltage tolerance, ±1.0% line regulation, ±3.0% load regulation, and a maximum ripple and noise floor of 120 mVp-p.

Housed in a fully enclosed UL 94V-0 flame-retardant plastic case (Case No. GS60A) measuring 50 × 31.5 × 125 mm (1.97 × 1.24 × 4.92 in), this 0.305 kg (0.67 lbs) adapter incorporates an integrated power-on LED indicator and a 1000 ± 50 mm (39.37 in) UL1185 16 AWG output cord. Comprehensive protection circuitry safeguards connected loads against short circuit, overload (105–150% hiccup auto-recovery), overvoltage (12.6–16.2 VDC latch-off), and overtemperature (latch-off shutdown) conditions, alongside Limited Power Source (LPS) qualification. Engineered with 3,000 VAC input-to-output, 2,000 VAC input-to-FG, and 500 VAC output-to-FG galvanic isolation (with -V floating from AC FG), the unit operates from -30 °C to +70 °C (-22 °F to +158 °F) with full 60W output up to +40 °C (+104 °F). Global compliance spans UL/EN/IEC 62368-1, DoE Level VI, EU ErP / CoC Version 5, and EN 55032 / FCC Part 15 Class B emissions.

Key Features

  • Regulated 12VDC 5A LPS Output: Delivers 60W continuous power (0–5A range) with ±3.0% voltage tolerance, ±1.0% line regulation, ±3.0% load regulation, and 120 mVp-p max ripple and noise under Limited Power Source (LPS) limits.
  • Factory P1M 2.5mm ID Coaxial Plug: Terminated with a heavy-duty 1000±50mm UL1185 16AWG DC cord and a straight 5.5mm OD × 2.5mm ID × 11.0mm center-positive tuning-fork plug rated up to 7.5A.
  • Level VI & CoC V5 Eco-Efficiency: Achieves 89.5% typical conversion efficiency and ultra-low standby power draw below 0.075W, satisfying USA EISA 2007/DoE Level VI, NRCan, EU ErP, and Code of Conduct (CoC) Version 5.
  • Universal Class I IEC320-C14 Input: Accepts 90 to 264VAC (47–63Hz) via a standard 3-pole IEC320-C14 inlet with earth ground (FG), providing 50ms hold-up time at 230VAC and 15ms at 115VAC full load.
  • 4-Stage Fault Protection Architecture: Combines 105–150% hiccup-mode overload auto-recovery with continuous short-circuit protection, plus 12.6–16.2VDC overvoltage and overtemperature latch-off shutdowns that require AC re-powering to reset.
  • 3kVAC Reinforced Isolation & Floating -V: Provides 3,000VAC input-to-output, 2,000VAC input-to-FG, and 500VAC output-to-FG dielectric strength (>100MΩ at 500VDC), keeping DC negative (-Vo) electrically isolated from AC functional ground.
  • Wide -30°C to +70°C Industrial Thermal Range: Operates via natural free-air convection inside a UL 94V-0 plastic enclosure, supporting 100% full-load 60W delivery up to +40°C and derating linearly to 50% load at +70°C.
  • Global ICT Safety & Class B EMC: Certified to UL 62368-1, CSA C22.2 No. 62368-1, TÜV EN 62368-1, BSMI, CCC, PSE, BIS, KC, and EAC, alongside EN 55032 / FCC Class B and Level 4 15kV/8kV ESD immunity.

Technical Specifications

Manufacturer Mean Well
Manufacturer Part Number (MPN) GST60A12-P1M
Alternate Part Number GST60A12P1M
OEM Cross-Reference / Replaced Part Safety Model: GST60A12 (Base Standard Model: GST60A12-P1J configured with optional P1M 5.5×2.5mm plug)
Product Series GST60A Series (60W AC-DC Reliable Green Industrial Adaptor)
Product Category Desktop Power Adapters
Component Type External AC-DC Desktop Power Supply / Industrial Green Adapter
Circuit Topology Switched-Mode Power Supply (SMPS), Class I with Functional Ground (FG), Limited Power Source (LPS)
Nominal Output Voltage 12 VDC
Rated Output Current 5 A
Output Current Range 0 to 5 A
Rated Output Power 60 W
Number of Outputs 1 (Single Output, -V not connected to AC FG)
Output Ripple & Noise (Max.) 120 mVp-p (measured at 20 MHz bandwidth with 12-inch twisted pair terminated with 0.1 µF & 47 µF parallel capacitors)
Output Voltage Tolerance ±3.0% (includes setup tolerance, line regulation, and load regulation)
Line Regulation ±1.0% (measured from low line to high line at rated load)
Load Regulation ±3.0%
Setup Time 1000 ms (at 115 / 230 VAC full load, cold start)
Rise Time 50 ms (at 115 / 230 VAC full load)
Hold-Up Time (at 115 VAC) 15 ms typ. (at full load)
Hold-Up Time (at 230 VAC) 50 ms typ. (at full load)
AC Input Voltage Range 90 to 264 VAC (Universal Full Range)
Input Frequency Range 47 to 63 Hz
Efficiency 89.5% typ. (at 230 VAC full load); Energy Efficiency Level VI
AC Input Current (at 115 VAC) 1.4 A typ.
AC Input Current (at 230 VAC) 1.0 A typ.
Inrush Current (Cold Start at 115 VAC) 35 A max.
Inrush Current (Cold Start at 230 VAC) 65 A max.
No-Load Power Consumption < 0.075 W
Mounting Style Desktop / External Inline Table-Top
Cooling Method Free Air Convection (Fanless)
Enclosure Case Number GS60A
Overall Width (W) 50 mm (1.97 in)
Overall Height (H) 31.5 mm (1.24 in)
Overall Depth (D) 125 mm (4.92 in)
Dimensional Tolerance ±1.0 mm (±0.04 in)
Net Weight 0.305 kg / 305 g (0.67 lbs / 10.76 oz)
Termination / Connector Style AC Input: 3-Pole IEC320-C14 Inlet; DC Output: P1M Straight Coaxial Tuning-Fork Barrel Plug (5.5 mm OD × 2.5 mm ID × 11.0 mm Length)
Input Terminal Pinout IEC320-C14 3-Prong Male Inlet: Line (L), Neutral (N), Functional/Earth Ground (FG)
Output & Signal Terminal Pinout P1M Coaxial Plug: Inside (Center) = +V (Positive), Outside (Barrel) = -V (Negative); Center Positive (C+), -V not connected to AC FG
Status Indicator Green LED Indicator for Power On
Lead Wire Length 1000 ± 50 mm (39.37 ± 1.97 in)
Terminal Wire Gauge Range UL1185 16 AWG DC Output Cord
Enclosure / Potting Material Fully Enclosed Flame-Retardant Plastic Case (UL 94V-0)
Overload Protection (OLP) Threshold 105% to 150% rated output power (Pass LPS)
Overload Protection (OLP) Mode Hiccup mode, recovers automatically after fault condition is removed
Overvoltage Protection (OVP) Threshold 12.6 to 16.2 VDC
Overvoltage Protection (OVP) Mode Shut down output voltage, re-power on to recover
Overtemperature Protection (OTP) Mode Shut down output voltage, re-power on to recover
Short Circuit Protection (SCP) Continuous, hiccup mode with automatic recovery
Withstand Isolation Voltage (I/P to O/P) 3,000 VAC (3 kVAC)
Withstand Isolation Voltage (I/P to FG / Case) 2,000 VAC (2 kVAC)
Withstand Isolation Voltage (O/P to FG / Case) 500 VAC (0.5 kVAC)
Isolation Resistance (at 500 VDC) ≥ 100 MΩ (I/P-O/P, I/P-FG, O/P-FG at 25 °C / 77 °F, 70% RH)
Earth Leakage Current 0.75 mA max. (at 240 VAC)
Operating Ambient Temperature Range -30 °C to +70 °C (-22 °F to +158 °F)
Full-Load Operating Temperature Limit +40 °C (+104 °F) at 100% load (60 W) horizontal mounting
High-Temperature Derating Rate Linearly derates from 100% load at +40 °C (+104 °F) to 50% load at +70 °C (+158 °F) (approx. 1.67% / °C)
Low-Line Input Derating 100% load from 100 to 264 VAC; derates linearly from 100% load at 100 VAC to 80% load at 90 VAC (60 Hz)
Altitude Derating 3.5 °C / 1,000 m (3,280 ft) ambient temperature derating for operating altitudes above 2,000 m (6,500 ft)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 20% to 90% RH (non-condensing)
Storage Relative Humidity 10% to 95% RH (non-condensing)
Temperature Coefficient ±0.03% / °C (0 °C to +50 °C / +32 °F to +122 °F)
Vibration Resistance 10 to 500 Hz, 2G, 10 min./1 cycle, period of 60 min. each along X, Y, and Z axes
Flammability Rating UL 94V-0
Safety Approvals (UL / North America) UL 62368-1, CSA C22.2 No. 62368-1 (cULus), Limited Power Source (LPS)
Safety Approvals (IEC / EN / TÜV) TÜV BS EN / EN 62368-1, CB IEC 62368-1, UKCA, CE
Safety Approvals (Regional / Global) BSMI CNS 15598-1 (Taiwan), CCC GB 4943.1 (China), PSE J62368-1 (Japan), AS/NZS 62368.1 (Australia/NZ), BIS IS 13252 (India), KC K60950-1 (Korea), EAC TP TC 004
EMC Conducted & Radiated Emissions BS EN/EN 55032 (CISPR 32) Class B, FCC Part 15 / CISPR 22 Class B, CAN ICES-3(B)/NMB-3(B), CNS 15936, GB 17625.1, EAC TP TC 020, MSIP KN32 Class B
EMC Harmonic & Flicker Compliance BS EN/EN 61000-3-2, GB 9254 Class A; BS EN/EN 61000-3-3
EMC Immunity Standards BS EN/EN 55035: EN 61000-4-2 ESD (Level 4: 15 kV air, 8 kV contact), EN 61000-4-3 Radiated RF (Level 2: 3 V/m), EN 61000-4-4 EFT/Burst (Level 2: 1 kV), EN 61000-4-5 Surge (Level 3: 1 kV L-L, 2 kV L-FG), EN 61000-4-6 Conducted RF (Level 2: 3 V), EN 61000-4-8 Magnetic Field (Level 2: 3 A/m), EN 61000-4-11 Voltage Dips (>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods)
MTBF (Telcordia SR-332 / Bellcore) 3,620,000 hours min. (3620.0K hrs at 25 °C / 77 °F)
MTBF (MIL-HDBK-217F) 709,700 hours min. (709.7K hrs at 25 °C / 77 °F)
Environmental Compliance EISA 2007 / DoE Level VI, NRCan, Korea K-MEPS, AU/NZ MEPS, EU ErP, CoC Version 5, RoHS

Industrial Applications & Compatible Systems

The Mean Well GST60A12-P1M is engineered for industrial, commercial, and OEM subsystems requiring a tightly regulated 12 VDC 5 A power source terminated with a 5.5 × 2.5 mm center-positive barrel plug:

  • Industrial Automation & Edge Computing: Powers fanless box PCs, HMIs, barcode/vision inspection cameras, and benchtop test instruments equipped with 2.5 mm ID high-current DC jacks.
  • Telecommunications & Networking Hardware: Supplies low-noise 12 VDC power (120 mVp-p max) to enterprise VoIP gateways, fiber media converters, cellular routers, and wireless base stations.
  • Office & Commercial POS Peripherals: Drives thermal receipt/label printers, point-of-sale terminals, document scanners, and kiosk sub-assemblies requiring Class B EMI compliance and DoE Level VI standby efficiency.
  • Portable Laboratory & Diagnostic Instruments: Provides floating-output (-V isolated from FG) Class I power with 3 kVAC dielectric isolation for analytical scales, optical sensors, and portable measurement gear.

Installation, Thermal Management & MRO Guidelines

Follow these engineering best practices to maximize adapter service life and ensure seamless integration:

  • Verify 2.5 mm vs. 2.1 mm Mating Jack Pin Diameter: The -P1M suffix features a 2.5 mm inner diameter (ID) tuning-fork barrel plug; mating it with a 2.1 mm center pin will result in loose contact and resistive heating at 5 A—use the standard GST60A12-P1J if your equipment uses a 2.1 mm pin.
  • Thermal & Low-Line Derating Envelope: Mount horizontally with unobstructed airflow to maintain 100% 60 W output up to +40 °C (+104 °F); derate load linearly at 1.67%/°C above +40 °C (down to 30 W at +70 °C) and cap output at 80% (48 W) when AC line voltage drops to 90 VAC.
  • AC Mains Cord & Inrush Breaker Sizing: Pair the IEC320-C14 inlet with a regionally certified 3-conductor IEC320-C13 power cord (minimum 18 AWG) to maintain Class I grounding and 2 kV line-to-FG surge immunity, and size upstream Type C/D circuit breakers to accommodate the 65 A cold-start inrush peak at 230 VAC.