HEP-240-24 Mean Well 240W 24VDC Waterproof Power Supply

$80.00

Mean Well HEP-240-24 (HEP24024) 240W 24VDC 10A enclosed waterproof power supply, 90-264VAC input, featuring IP68 silicone-potted aluminum case and 10G vibration.

SKU: HEP-240-24 Category: Brand:

Description

Mean Well HEP-240-24 (also known as HEP24024) is an industrial 240W harsh-environment AC-DC switching power supply from the HEP-240 series. In Mean Well’s nomenclature, the blank suffix designates the factory-sealed IP68 waterproof configuration with fixed output voltage and current settings, distinguishing it from the IP65 potentiometer-adjustable A-type variant. Engineered with an active power factor correction (PFC) stage and a 100 kHz PWM switching topology, the unit accepts a universal 90 to 264 VAC (277 VAC operational) or 128 to 370 VDC input to deliver a tightly regulated 24 VDC at 10 A output. It achieves up to 92.5% conversion efficiency, 150 mVp-p maximum ripple and noise, ±1.0% voltage tolerance, and ±0.5% line and load regulation.

Housed in a rugged Case No. 994H anodized aluminum chassis measuring 244.2 × 68.0 × 38.8 mm (9.61 × 2.68 × 1.53 in) and fully encapsulated with thermally conductive silicone, the fanless supply dissipates heat via free air convection and withstands 10G vibration across 20 to 500 Hz. Pre-wired 300 mm SJTW input (18 AWG × 3C) and output (14 AWG × 2C) flying leads provide hermetic connectivity verified to 1,000 mm water submersion for one month. Comprehensive protection circuits cover 105% to 125% constant-current overload limiting, short-circuit auto-recovery, 27 to 34 V latch-off overvoltage protection, and auto-recovering overtemperature shutdown. The unit features 3.75 kVAC input-to-output galvanic isolation, operates across an extreme -55 °C to +70 °C (-67 °F to +158 °F) ambient window, and holds UL 62368-1, IEC 62368-1, CE, EAC TP TC 004, and 6 kV surge immunity approvals.

Key Features

  • Full IP68 Hermetic Encapsulation: Extruded aluminum Case 994H enclosure completely potted with heat-conductive silicone meets IP68 submersible standards (tested 1000 mm underwater for 1 month) while resisting extreme dust, moisture, and corrosive atmospheres.
  • Wide-Range AC/DC Input & Active PFC: Accepts 90 to 264 VAC (277 VAC operational) at 47 to 63 Hz or 128 to 370 VDC (390 VDC operational) with built-in active PFC achieving PF > 0.98 at 115 VAC and PF > 0.95 at 230 VAC.
  • High-Efficiency 24VDC / 10A Output: Delivers 240 W continuous output power at 92.5% typical efficiency with ±0.5% line and load regulation, ±1.0% total voltage tolerance, and low 150 mVp-p maximum ripple and noise.
  • Extreme -55°C to +70°C Thermal Window: Fanless free-air convection architecture operates from -55 °C to +70 °C (-67 °F to +158 °F), delivering 100% full-load power up to +50 °C at 230 VAC and operating up to 5,000 m altitude.
  • 10G Vibration & 6kV Surge Immunity: Engineered for petroleum plants, mine shafts, and outdoor telecom towers with 10G three-axis vibration endurance (20 to 500 Hz) and 6 kV line surge immunity per EN 61000-4-5.
  • Comprehensive Multi-Stage Protections: Integrates constant-current overload limiting (105% to 125% with auto-recovery), continuous short-circuit protection, latch-off overvoltage protection (27 to 34 V), and auto-recovering overtemperature shutdown.
  • Reinforced 3.75 kVAC Galvanic Isolation: Provides 3,750 VAC input-to-output, 2,000 VAC input-to-ground, and 1,500 VAC output-to-ground dielectric withstand strength alongside >100 MΩ isolation resistance and <0.75 mA earth leakage current.

Technical Specifications

Manufacturer Mean Well
Manufacturer Part Number (MPN) HEP-240-24
Alternate Part Number HEP24024
Compatible Equipment / Series Outdoor Telecommunication Equipment, Electronic Signage & Billboards, Petroleum Plant & Mine Shaft Facilities, Harsh Industrial Control Systems
Product Series HEP-240 Series
Product Category Waterproof Power Supplies
Component Type Harsh-Environment Enclosed Waterproof AC-DC Switching Power Supply (Blank-Type Fixed Output IP68 Version)
Circuit Topology Active PFC + PWM Switching Topology (100 kHz Fixed Switching Frequency)
Nominal Output Voltage 24 VDC (Fixed output on Blank-Type IP68 model; 22.4 to 25.6 VDC adjustable on A-Type IP65 model)
Rated Output Current 10 A (Fixed constant-current limit on Blank-Type IP68 model; 5 to 10 A adjustable on A-Type IP65 model)
Rated Output Power 240 W
Number of Outputs 1 Output (Single Channel)
Output Ripple & Noise (Max.) 150 mVp-p (measured at 20 MHz bandwidth with 0.1 µF & 47 µF parallel capacitor)
Output Voltage Tolerance ±1.0% (includes setup tolerance, line regulation, and load regulation)
Line Regulation ±0.5%
Load Regulation ±0.5%
Setup Time (at 115 VAC) 1000 ms (at full load, cold start)
Setup Time (at 230 VAC) 500 ms (at full load, cold start)
Rise Time 80 ms (at 115 / 230 VAC full load)
Hold-Up Time 15 ms typ. (at 115 / 230 VAC full load)
AC Input Voltage Range 90 to 264 VAC (277 VAC operational)
DC Input Voltage Range 128 to 370 VDC (390 VDC operational)
Input Frequency Range 47 to 63 Hz
Efficiency 92.5% typ. (at 230 VAC full load)
AC Input Current (at 115 VAC) 2.5 A typ.
AC Input Current (at 230 VAC) 1.3 A typ. (1.1 A typ. at 277 VAC)
Inrush Current (Cold Start at 230 VAC) 75 A typ.
Power Factor (PF at 115 VAC) > 0.98 (at full load)
Power Factor (PF at 230 VAC) > 0.95 at 230 VAC (> 0.92 at 277 VAC, full load)
Power Factor Correction (PFC) Built-in Active PFC Function
Switching Frequency 100 kHz
Mounting Style Chassis / Baseplate Mount (4 × Ø4.2 mm mounting slots on integrated aluminum flanges)
Cooling Method Fanless, Cooling by Free Air Convection
Enclosure Case Number 994H
Overall Width (W) 68.0 mm (2.68 in)
Overall Height (H) 38.8 mm (1.53 in)
Overall Depth (D) 244.2 mm (9.61 in)
Dimensional Tolerance ±1.0 mm (±0.04 in)
Mounting Hole Pitch 220.2 × 34.0 / 34.2 mm (8.67 × 1.34 / 1.35 in) center-to-center; 4 × Ø4.2 mm slots
Net Weight 1.30 kg (2.87 lbs / 45.86 oz)
Termination / Connector Style Pre-Wired Waterproof Flying Lead Cables (SJTW jacketed)
Input Terminal Pinout SJTW 18 AWG × 3C Cable: AC/L (Brown), AC/N (Blue), FG (Green/Yellow)
Output & Signal Terminal Pinout SJTW 14 AWG × 2C Cable: +V (Red), -V (Black)
Lead Wire Length Input Cable: 300 ± 20 mm (11.81 ± 0.79 in); Output Cable: 300 ± 20 mm (11.81 ± 0.79 in)
Terminal Wire Gauge Range Input: 18 AWG × 3C SJTW; Output: 14 AWG × 2C SJTW
Enclosure / Potting Material Anodized Aluminum Case Fully Potted with Heat-Conducted Silicone
Overload Protection (OLP) Threshold 105% to 125% of rated output power
Overload Protection (OLP) Mode Constant current limiting, recovers automatically after fault condition is removed
Overvoltage Protection (OVP) Threshold 27 to 34 VDC
Overvoltage Protection (OVP) Mode Shut down and latch off output voltage, re-power on to recover
Overtemperature Protection (OTP) Mode Shut down output voltage, recovers automatically after temperature goes down
Short Circuit Protection (SCP) Constant current limiting, recovers automatically after fault condition is removed
Withstand Isolation Voltage (I/P to O/P) 3.75 kVAC (3,750 VAC)
Withstand Isolation Voltage (I/P to FG / Case) 2.0 kVAC (2,000 VAC)
Withstand Isolation Voltage (O/P to FG / Case) 1.5 kVAC (1,500 VAC)
Isolation Resistance (at 500 VDC) > 100 MΩ (I/P-O/P, I/P-FG, O/P-FG at 500 VDC, 25 °C, 70% RH)
Earth Leakage Current < 0.75 mA (at 277 VAC)
Operating Ambient Temperature Range -55 °C to +70 °C (-67 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 230 VAC horizontal mounting; +40 °C (+104 °F) at 110 VAC
High-Temperature Derating Rate 2.5% / °C from +50 °C to +70 °C at 230 VAC (50% load at +70 °C); derates to 60% load from -40 °C down to -55 °C
Low-Line Input Derating Derates linearly from 100% load at 100 VAC down to 80% load at 90 VAC
Altitude Derating Operating altitude up to 5,000 m (16,404 ft); ambient temperature derating of 3.5 °C / 1,000 m above 2,000 m (6,500 ft)
Storage Temperature Range -60 °C to +80 °C (-76 °F to +176 °F)
Operating Relative Humidity 20% to 95% RH (non-condensing)
Storage Relative Humidity 10% to 95% RH (non-condensing)
Temperature Coefficient ±0.03% / °C (0 °C to 60 °C)
Vibration Resistance 10G (20 to 500 Hz, 12 min/cycle, 72 min each along X, Y, Z axes)
Ingress Protection (IP) IP68 (Blank-Type HEP-240-24 tested 1,000 mm below water surface for 1 month; A-Type is IP65)
Safety Approvals (UL / North America) UL 62368-1, cULus Recognized
Safety Approvals (IEC / EN / TÜV) IEC 62368-1 (CB Scheme), Design refers to BS EN / EN 62368-1
Safety Approvals (Regional / Global) CE, UKCA, EAC TP TC 004
EMC Conducted & Radiated Emissions Compliance to BS EN / EN 55032 (CISPR 32) Class B, EAC TP TC 020
EMC Harmonic & Flicker Compliance Compliance to BS EN / EN 61000-3-2, BS EN / EN 61000-3-3
EMC Immunity Standards Compliance to BS EN / EN 61000-4-2, 3, 4, 5 (6 kV surge immunity level), 6, 8, 11, BS EN / EN 55035 Light Industry Level, EAC TP TC 020
MTBF (Telcordia SR-332 / Bellcore) 2,008,700 hours min. (at 25 °C)
MTBF (MIL-HDBK-217F) 171,300 hours min. (at 25 °C)
Environmental Compliance RoHS Compliant, 6-Year Manufacturer Warranty

Industrial Applications & Compatible Systems

Engineered for extreme industrial deployments, the Mean Well HEP-240-24 delivers reliable 24 VDC power across unconditioned outdoor and heavy-duty facilities:

  • Outdoor Telecommunication Base Stations: Powers 24 VDC remote radio heads (RRHs), microwave backhaul transceivers, and tower-mounted network switches exposed to sub-zero winters (-55 °C) and 6 kV lightning-induced line surges.
  • Mining & Petroleum Processing Facilities: Supplies intrinsically isolated 24 VDC instrumentation, gas detection arrays, and valve actuators in high-humidity mine shafts and petrochemical plants requiring 10G vibration endurance and IP68 washdown protection.
  • Outdoor Electronic Signage & Transportation Displays: Drives highway variable message signs (VMS), outdoor commercial billboards, and railway platform displays where conductive dust and heavy rain compromise standard ventilated enclosures.
  • Harsh-Environment Factory Automation & Marine Equipment: Supports washdown food-processing machinery, automated car washes, and deck-mounted marine control boxes requiring sealed silicone-potted power architecture.

Installation, Thermal Management & MRO Guidelines

To maximize service life and preserve waterproof integrity during field installation, observe these engineering practices:

  • Blank-Type IP68 vs. A-Type IP65 Selection: The standard HEP-240-24 (Blank-Type) features a completely sealed housing rated to IP68 with fixed 24 VDC / 10 A output, whereas the HEP-240-24A variant is rated IP65 and includes rubber-stoppered internal potentiometers for trimming voltage (22.4–25.6 V) and current (5–10 A).
  • Thermal & Low-Line Derating Management: Mount the aluminum baseplate horizontally onto a metallic surface with adequate free-air convection; derate continuous output load by 2.5% per °C above +50 °C (at 230 VAC) or above +40 °C (at 110 VAC), and limit load to 80% when operating at 90 VAC low-line input.
  • Upstream Breaker Sizing for 75A Inrush: Account for the 75 A cold-start inrush current at 230 VAC by selecting an upstream C-curve or D-curve miniature circuit breaker (MCB) and using IP68-rated waterproof junction boxes or gel-filled splices when terminating the 300 mm SJTW flying leads.