Description
Mean Well HEP-240-24 (also known as HEP24024) is an industrial 240W harsh-environment AC-DC switching power supply from the HEP-240 series. In Mean Well’s nomenclature, the blank suffix designates the factory-sealed IP68 waterproof configuration with fixed output voltage and current settings, distinguishing it from the IP65 potentiometer-adjustable A-type variant. Engineered with an active power factor correction (PFC) stage and a 100 kHz PWM switching topology, the unit accepts a universal 90 to 264 VAC (277 VAC operational) or 128 to 370 VDC input to deliver a tightly regulated 24 VDC at 10 A output. It achieves up to 92.5% conversion efficiency, 150 mVp-p maximum ripple and noise, ±1.0% voltage tolerance, and ±0.5% line and load regulation.
Housed in a rugged Case No. 994H anodized aluminum chassis measuring 244.2 × 68.0 × 38.8 mm (9.61 × 2.68 × 1.53 in) and fully encapsulated with thermally conductive silicone, the fanless supply dissipates heat via free air convection and withstands 10G vibration across 20 to 500 Hz. Pre-wired 300 mm SJTW input (18 AWG × 3C) and output (14 AWG × 2C) flying leads provide hermetic connectivity verified to 1,000 mm water submersion for one month. Comprehensive protection circuits cover 105% to 125% constant-current overload limiting, short-circuit auto-recovery, 27 to 34 V latch-off overvoltage protection, and auto-recovering overtemperature shutdown. The unit features 3.75 kVAC input-to-output galvanic isolation, operates across an extreme -55 °C to +70 °C (-67 °F to +158 °F) ambient window, and holds UL 62368-1, IEC 62368-1, CE, EAC TP TC 004, and 6 kV surge immunity approvals.
Key Features
- Full IP68 Hermetic Encapsulation: Extruded aluminum Case 994H enclosure completely potted with heat-conductive silicone meets IP68 submersible standards (tested 1000 mm underwater for 1 month) while resisting extreme dust, moisture, and corrosive atmospheres.
- Wide-Range AC/DC Input & Active PFC: Accepts 90 to 264 VAC (277 VAC operational) at 47 to 63 Hz or 128 to 370 VDC (390 VDC operational) with built-in active PFC achieving PF > 0.98 at 115 VAC and PF > 0.95 at 230 VAC.
- High-Efficiency 24VDC / 10A Output: Delivers 240 W continuous output power at 92.5% typical efficiency with ±0.5% line and load regulation, ±1.0% total voltage tolerance, and low 150 mVp-p maximum ripple and noise.
- Extreme -55°C to +70°C Thermal Window: Fanless free-air convection architecture operates from -55 °C to +70 °C (-67 °F to +158 °F), delivering 100% full-load power up to +50 °C at 230 VAC and operating up to 5,000 m altitude.
- 10G Vibration & 6kV Surge Immunity: Engineered for petroleum plants, mine shafts, and outdoor telecom towers with 10G three-axis vibration endurance (20 to 500 Hz) and 6 kV line surge immunity per EN 61000-4-5.
- Comprehensive Multi-Stage Protections: Integrates constant-current overload limiting (105% to 125% with auto-recovery), continuous short-circuit protection, latch-off overvoltage protection (27 to 34 V), and auto-recovering overtemperature shutdown.
- Reinforced 3.75 kVAC Galvanic Isolation: Provides 3,750 VAC input-to-output, 2,000 VAC input-to-ground, and 1,500 VAC output-to-ground dielectric withstand strength alongside >100 MΩ isolation resistance and <0.75 mA earth leakage current.
Technical Specifications
| Manufacturer | Mean Well |
|---|---|
| Manufacturer Part Number (MPN) | HEP-240-24 |
| Alternate Part Number | HEP24024 |
| Compatible Equipment / Series | Outdoor Telecommunication Equipment, Electronic Signage & Billboards, Petroleum Plant & Mine Shaft Facilities, Harsh Industrial Control Systems |
| Product Series | HEP-240 Series |
| Product Category | Waterproof Power Supplies |
| Component Type | Harsh-Environment Enclosed Waterproof AC-DC Switching Power Supply (Blank-Type Fixed Output IP68 Version) |
| Circuit Topology | Active PFC + PWM Switching Topology (100 kHz Fixed Switching Frequency) |
| Nominal Output Voltage | 24 VDC (Fixed output on Blank-Type IP68 model; 22.4 to 25.6 VDC adjustable on A-Type IP65 model) |
| Rated Output Current | 10 A (Fixed constant-current limit on Blank-Type IP68 model; 5 to 10 A adjustable on A-Type IP65 model) |
| Rated Output Power | 240 W |
| Number of Outputs | 1 Output (Single Channel) |
| Output Ripple & Noise (Max.) | 150 mVp-p (measured at 20 MHz bandwidth with 0.1 µF & 47 µF parallel capacitor) |
| Output Voltage Tolerance | ±1.0% (includes setup tolerance, line regulation, and load regulation) |
| Line Regulation | ±0.5% |
| Load Regulation | ±0.5% |
| Setup Time (at 115 VAC) | 1000 ms (at full load, cold start) |
| Setup Time (at 230 VAC) | 500 ms (at full load, cold start) |
| Rise Time | 80 ms (at 115 / 230 VAC full load) |
| Hold-Up Time | 15 ms typ. (at 115 / 230 VAC full load) |
| AC Input Voltage Range | 90 to 264 VAC (277 VAC operational) |
| DC Input Voltage Range | 128 to 370 VDC (390 VDC operational) |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency | 92.5% typ. (at 230 VAC full load) |
| AC Input Current (at 115 VAC) | 2.5 A typ. |
| AC Input Current (at 230 VAC) | 1.3 A typ. (1.1 A typ. at 277 VAC) |
| Inrush Current (Cold Start at 230 VAC) | 75 A typ. |
| Power Factor (PF at 115 VAC) | > 0.98 (at full load) |
| Power Factor (PF at 230 VAC) | > 0.95 at 230 VAC (> 0.92 at 277 VAC, full load) |
| Power Factor Correction (PFC) | Built-in Active PFC Function |
| Switching Frequency | 100 kHz |
| Mounting Style | Chassis / Baseplate Mount (4 × Ø4.2 mm mounting slots on integrated aluminum flanges) |
| Cooling Method | Fanless, Cooling by Free Air Convection |
| Enclosure Case Number | 994H |
| Overall Width (W) | 68.0 mm (2.68 in) |
| Overall Height (H) | 38.8 mm (1.53 in) |
| Overall Depth (D) | 244.2 mm (9.61 in) |
| Dimensional Tolerance | ±1.0 mm (±0.04 in) |
| Mounting Hole Pitch | 220.2 × 34.0 / 34.2 mm (8.67 × 1.34 / 1.35 in) center-to-center; 4 × Ø4.2 mm slots |
| Net Weight | 1.30 kg (2.87 lbs / 45.86 oz) |
| Termination / Connector Style | Pre-Wired Waterproof Flying Lead Cables (SJTW jacketed) |
| Input Terminal Pinout | SJTW 18 AWG × 3C Cable: AC/L (Brown), AC/N (Blue), FG (Green/Yellow) |
| Output & Signal Terminal Pinout | SJTW 14 AWG × 2C Cable: +V (Red), -V (Black) |
| Lead Wire Length | Input Cable: 300 ± 20 mm (11.81 ± 0.79 in); Output Cable: 300 ± 20 mm (11.81 ± 0.79 in) |
| Terminal Wire Gauge Range | Input: 18 AWG × 3C SJTW; Output: 14 AWG × 2C SJTW |
| Enclosure / Potting Material | Anodized Aluminum Case Fully Potted with Heat-Conducted Silicone |
| Overload Protection (OLP) Threshold | 105% to 125% of rated output power |
| Overload Protection (OLP) Mode | Constant current limiting, recovers automatically after fault condition is removed |
| Overvoltage Protection (OVP) Threshold | 27 to 34 VDC |
| Overvoltage Protection (OVP) Mode | Shut down and latch off output voltage, re-power on to recover |
| Overtemperature Protection (OTP) Mode | Shut down output voltage, recovers automatically after temperature goes down |
| Short Circuit Protection (SCP) | Constant current limiting, recovers automatically after fault condition is removed |
| Withstand Isolation Voltage (I/P to O/P) | 3.75 kVAC (3,750 VAC) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2.0 kVAC (2,000 VAC) |
| Withstand Isolation Voltage (O/P to FG / Case) | 1.5 kVAC (1,500 VAC) |
| Isolation Resistance (at 500 VDC) | > 100 MΩ (I/P-O/P, I/P-FG, O/P-FG at 500 VDC, 25 °C, 70% RH) |
| Earth Leakage Current | < 0.75 mA (at 277 VAC) |
| Operating Ambient Temperature Range | -55 °C to +70 °C (-67 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 230 VAC horizontal mounting; +40 °C (+104 °F) at 110 VAC |
| High-Temperature Derating Rate | 2.5% / °C from +50 °C to +70 °C at 230 VAC (50% load at +70 °C); derates to 60% load from -40 °C down to -55 °C |
| Low-Line Input Derating | Derates linearly from 100% load at 100 VAC down to 80% load at 90 VAC |
| Altitude Derating | Operating altitude up to 5,000 m (16,404 ft); ambient temperature derating of 3.5 °C / 1,000 m above 2,000 m (6,500 ft) |
| Storage Temperature Range | -60 °C to +80 °C (-76 °F to +176 °F) |
| Operating Relative Humidity | 20% to 95% RH (non-condensing) |
| Storage Relative Humidity | 10% to 95% RH (non-condensing) |
| Temperature Coefficient | ±0.03% / °C (0 °C to 60 °C) |
| Vibration Resistance | 10G (20 to 500 Hz, 12 min/cycle, 72 min each along X, Y, Z axes) |
| Ingress Protection (IP) | IP68 (Blank-Type HEP-240-24 tested 1,000 mm below water surface for 1 month; A-Type is IP65) |
| Safety Approvals (UL / North America) | UL 62368-1, cULus Recognized |
| Safety Approvals (IEC / EN / TÜV) | IEC 62368-1 (CB Scheme), Design refers to BS EN / EN 62368-1 |
| Safety Approvals (Regional / Global) | CE, UKCA, EAC TP TC 004 |
| EMC Conducted & Radiated Emissions | Compliance to BS EN / EN 55032 (CISPR 32) Class B, EAC TP TC 020 |
| EMC Harmonic & Flicker Compliance | Compliance to BS EN / EN 61000-3-2, BS EN / EN 61000-3-3 |
| EMC Immunity Standards | Compliance to BS EN / EN 61000-4-2, 3, 4, 5 (6 kV surge immunity level), 6, 8, 11, BS EN / EN 55035 Light Industry Level, EAC TP TC 020 |
| MTBF (Telcordia SR-332 / Bellcore) | 2,008,700 hours min. (at 25 °C) |
| MTBF (MIL-HDBK-217F) | 171,300 hours min. (at 25 °C) |
| Environmental Compliance | RoHS Compliant, 6-Year Manufacturer Warranty |
Industrial Applications & Compatible Systems
Engineered for extreme industrial deployments, the Mean Well HEP-240-24 delivers reliable 24 VDC power across unconditioned outdoor and heavy-duty facilities:
- Outdoor Telecommunication Base Stations: Powers 24 VDC remote radio heads (RRHs), microwave backhaul transceivers, and tower-mounted network switches exposed to sub-zero winters (-55 °C) and 6 kV lightning-induced line surges.
- Mining & Petroleum Processing Facilities: Supplies intrinsically isolated 24 VDC instrumentation, gas detection arrays, and valve actuators in high-humidity mine shafts and petrochemical plants requiring 10G vibration endurance and IP68 washdown protection.
- Outdoor Electronic Signage & Transportation Displays: Drives highway variable message signs (VMS), outdoor commercial billboards, and railway platform displays where conductive dust and heavy rain compromise standard ventilated enclosures.
- Harsh-Environment Factory Automation & Marine Equipment: Supports washdown food-processing machinery, automated car washes, and deck-mounted marine control boxes requiring sealed silicone-potted power architecture.
Installation, Thermal Management & MRO Guidelines
To maximize service life and preserve waterproof integrity during field installation, observe these engineering practices:
- Blank-Type IP68 vs. A-Type IP65 Selection: The standard HEP-240-24 (Blank-Type) features a completely sealed housing rated to IP68 with fixed 24 VDC / 10 A output, whereas the HEP-240-24A variant is rated IP65 and includes rubber-stoppered internal potentiometers for trimming voltage (22.4–25.6 V) and current (5–10 A).
- Thermal & Low-Line Derating Management: Mount the aluminum baseplate horizontally onto a metallic surface with adequate free-air convection; derate continuous output load by 2.5% per °C above +50 °C (at 230 VAC) or above +40 °C (at 110 VAC), and limit load to 80% when operating at 90 VAC low-line input.
- Upstream Breaker Sizing for 75A Inrush: Account for the 75 A cold-start inrush current at 230 VAC by selecting an upstream C-curve or D-curve miniature circuit breaker (MCB) and using IP68-rated waterproof junction boxes or gel-filled splices when terminating the 300 mm SJTW flying leads.