Description
XP Power ECL25US12-P (also known as ECL25US12P) is an ultra-compact 25 W single-output AC-DC power supply from the ECL25 series, where US12 designates a universal-input single 12.0 VDC output rail and the -P suffix specifies an open-frame through-hole PCB-mount form factor. Operating across a universal 85–264 VAC (47–63 Hz) or 120–370 VDC input range with an internal T2 A / 250 VAC slow-blow fuse, this 70 kHz switched-mode supply delivers a continuous rated current of 2.10 A and supports short-duration peak loads up to 2.73 A (32.76 W for up to 30 seconds at 10% duty cycle) to handle inductive startup surges. It achieves an 80% typical efficiency, ultra-low no-load power consumption under 0.3 W, and requires zero minimum load while maintaining tight ±1% initial voltage accuracy, ±0.5% line regulation, 1% load regulation, and low output ripple of 120 mV pk-pk max. An onboard potentiometer provides a ±5% output voltage trim range (11.4 to 12.6 VDC) to compensate for PCB trace voltage drops.
Engineered for high-density embedded instrumentation with a power density of 5.90 W/in³, the ECL25US12-P occupies a compact 34.6 × 22.3 × 75.2 mm (1.36 × 0.88 × 2.96 in) footprint and weighs only 66 g (0.14 lbs). It mounts directly to host circuit boards via four Ø 1.0 mm (0.039 in) solder pins (ACN, ACL, +Vo, -Vo) in a Class II double-insulated construction that eliminates the need for an earth ground connection. Comprehensive self-protecting circuitry includes 115–140% Vnom overvoltage protection, 120–170% overload protection, and continuous trip-and-restart (hiccup mode) short-circuit protection backed by reinforced 3000 VAC input-to-output galvanic isolation. Natural convection cooling supports operation from -20 °C to +70 °C (-4 °F to +158 °F) with full 25 W output up to +50 °C (+122 °F), full compliance with UL/IEC/EN 62368-1 safety standards, and EN 55032 Class B EMI performance without external filtering.
Key Features
- Continuous 25 W & 130% Peak Load Delivery: Supplies 12.0 VDC at 2.10 A continuous (25 W) and bursts up to 2.73 A (32.76 W) for up to 30 seconds (10% duty cycle) to drive inductive actuators, relays, and DC motors.
- Wide Universal AC/DC Input & Eco Standby: Accepts 85–264 VAC (47–63 Hz) or 120–370 VDC with an integrated T2 A / 250 VAC input fuse and consumes less than 0.3 W at no load for energy-conscious installations.
- High-Density Open-Frame PCB Footprint: Delivers 5.90 W/in³ power density in a miniature 75.2 × 34.6 × 22.3 mm (2.96 × 1.36 × 0.88 in), 66 g package with four Ø 1.0 mm through-hole solder pins.
- Precision Regulation & Onboard ±5% Trim: Features ±1% initial set accuracy, ±0.5% line regulation, 1% load regulation with zero minimum load required, 120 mV pk-pk max ripple, and an onboard ±5% Vout adjustment potentiometer.
- Class II 3000 VAC Reinforced Isolation: Operates without a safety earth ground connection (Class II construction) while providing 3000 VAC input-to-output galvanic isolation and 16 ms typical hold-up time at 115 VAC.
- Comprehensive Hiccup Fault Protection: Incorporates 120–170% overload protection, 115–140% Vnom overvoltage protection, and continuous trip-and-restart (hiccup mode) short-circuit protection for autonomous recovery after fault clearance.
- Wide Convection Thermal Envelope: Operates from -20 °C to +70 °C (-4 °F to +158 °F) under free air convection, delivering 100% rated load up to +50 °C (+122 °F) and derating linearly to 50% load at +70 °C.
- Global ITE Safety & Class B EMC Compliance: Certified to UL 62368-1, CAN/CSA C22.2 No. 62368-1-14, IEC/EN 62368-1, and IEC 60950-1, while meeting EN 55032 Class B conducted and radiated emissions and EN 61000-4 immunity standards.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | ECL25US12-P |
| Alternate Part Number | ECL25US12P |
| Compatible Equipment / Series | XP Power ECL25 Series (Open-Frame PCB-Mount Variant; Mechanical Counterparts: ECL25US12-E Encapsulated, ECL25US12-T Chassis, ECL25US12-S Screw Terminal) |
| Product Series | ECL25 Series |
| Product Category | Open Frame PSUs |
| Component Type | Open-Frame Through-Hole PCB-Mount AC-DC Power Supply |
| Circuit Topology | Switched-Mode Power Supply (SMPS), Single-Output Flyback, Class II Double Insulated |
| Nominal Output Voltage | 12.0 VDC |
| Output Voltage Adjustment Range | 11.4 to 12.6 VDC (±5% via onboard V Adj. potentiometer) |
| Rated Output Current | 2.10 A |
| Output Current Range | 0 to 2.10 A (No minimum load required) |
| Peak / Surge Output Current | 2.73 A (Max. 30 s duration, 10% max. duty cycle; average output power not to exceed 25 W) |
| Rated Output Power | 25 W |
| Peak Output Power | 32.76 W (130% peak load for <30 s at 10% max. duty cycle) |
| Number of Outputs | 1 Output (Single Output) |
| Output Ripple & Noise (Max.) | 120 mV pk-pk (Measured at 20 MHz bandwidth) |
| Output Voltage Tolerance | ±1.0% initial set accuracy |
| Line Regulation | ±0.5% max. |
| Load Regulation | ±1.0% max. (0% to 100% load) |
| Transient Recovery Time & Deviation | 4% max. deviation, recovery to within 1% in 500 µs for a 25% load step change |
| Setup Time | 3000 ms (3 s) max. start-up delay |
| Rise Time | 14 ms max. start-up rise time |
| Hold-Up Time (at 115 VAC) | 16 ms typical (at full load and 115 VAC) |
| AC Input Voltage Range | 85 to 264 VAC |
| DC Input Voltage Range | 120 to 370 VDC |
| Nominal Input Voltage | 100 to 240 VAC (Universal Input) |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency | 80% typical |
| AC Input Current (at 230 VAC) | 0.4 A rms (at 230 VAC full load) |
| Inrush Current (Cold Start at 115 VAC) | 20 A peak (Cold start at +25 °C) |
| Inrush Current (Cold Start at 230 VAC) | 40 A peak (Cold start at +25 °C) |
| Power Factor Correction (PFC) | Passive compliance to EN 61000-3-2 Class A |
| No-Load Power Consumption | < 0.3 W |
| Switching Frequency | 70 kHz typical |
| Mounting Style | Through-Hole PCB Mount (4 Solder Pins) |
| Cooling Method | Free Air Convection (Convection-cooled) |
| Package / Footprint Standard | Open-Frame PCB Mount (-P Suffix), 5.90 W/in³ Power Density |
| Overall Width (W) | 34.6 mm (1.36 in) |
| Overall Height (H) | 22.3 mm (0.88 in) max. |
| Overall Depth (D) | 75.2 mm (2.96 in) |
| Dimensional Tolerance | ±0.5 mm (±0.02 in) for 2-decimal inch dimensions; ±0.25 mm (±0.01 in) for 3-decimal inch dimensions |
| Mounting Hole Pitch | 72.4 mm (2.85 in) input-to-output pin pitch; 15.0 mm (0.59 in) ACN-to-ACL input pin spacing; 15.0 mm (0.59 in) -Vo-to-+Vo output pin spacing |
| Net Weight | 66 g (0.066 kg / 0.14 lbs / 2.33 oz) |
| Termination / Connector Style | 4 × Ø 1.0 mm (Ø 0.039 in) Through-Hole PCB Solder Pins (Suggested PCB hole diameter: Ø 1.8 mm / Ø 0.07 in; pin length: 4.4 mm / 0.17 in) |
| Input Terminal Pinout | Primary Side PCB Pins: ACN (AC Neutral), ACL (AC Line); protected by internal T2 A / 250 VAC fuse |
| Output & Signal Terminal Pinout | Secondary Side PCB Pins: -Vo (DC Output Negative), +Vo (DC Output Positive); onboard V Adj. trim potentiometer near +Vo |
| Overload Protection (OLP) Threshold | 120% to 170% of rated output power |
| Overload Protection (OLP) Mode | Trip and restart (Hiccup mode), automatic recovery upon fault removal |
| Overvoltage Protection (OVP) Threshold | 115% to 140% of nominal output voltage (13.8 to 16.8 VDC) |
| Short Circuit Protection (SCP) | Continuous trip and restart (Hiccup mode) with auto-recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC rms |
| Earth Leakage Current | Class II double-insulated construction (No earth ground connection required) |
| Operating Ambient Temperature Range | -20 °C to +70 °C (-4 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% load (25 W) |
| High-Temperature Derating Rate | Derate linearly at 2.5% per °C from 100% load (25 W) at +50 °C (+122 °F) to 50% load (12.5 W) at +70 °C (+158 °F) |
| Altitude Derating | Up to 3000 m (9842 ft) operating altitude |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | Up to 95% RH, non-condensing |
| Temperature Coefficient | ±0.05% / °C |
| Vibration Resistance | 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins per axis |
| Safety Approvals (UL / North America) | UL 62368-1, CAN/CSA C22.2 No. 62368-1-14 |
| Safety Approvals (IEC / EN / TÜV) | IEC 62368-1:2014, EN 62368-1:2014/A11:2017, IEC 60950-1:2005 Ed 2 |
| EMC Conducted & Radiated Emissions | EN 55032 Level B (Conducted and Radiated) |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A, EN 61000-3-3 |
| EMC Immunity Standards | EN 61000-4-2 (ESD Level 3, Criteria A), EN 61000-4-3 (Radiated 10 V/m 80% mod, Criteria A), EN 61000-4-4 (EFT/Burst Level 3, Criteria A), EN 61000-4-5 (Surge Installation Class 3, Criteria A), EN 61000-4-6 (Conducted 10 Vrms, Criteria A), EN 61000-4-8 (Magnetic Field 10 A/m, Criteria A), EN 61000-4-11 (Voltage Dips 30% 10 ms Criteria A, 60% 100 ms Criteria B, 100% 5000 ms Criteria B) |
| MTBF (MIL-HDBK-217F) | > 400,000 Hours (> 400 kHrs) at +25 °C (+77 °F), Ground Benign (GB) |
| Environmental Compliance | RoHS Compliant, REACH Compliant, 3-Year Manufacturer Warranty |
Industrial Applications & Compatible Systems
The XP Power ECL25US12-P is engineered for space-constrained industrial, commercial, and instrumentation host PCBs requiring an ultra-compact, Class II isolated 12 VDC board-mount power source:
- Industrial Automation & PLC Expansion I/O Boards: Powers 12 VDC sensor excitation rails, RS-485/CANbus isolated transceivers, optical encoders, and embedded microcontroller cards inside compact machine control enclosures.
- Motor, Solenoid & Valve Actuation Controllers: Leverages its 130% peak current capability (2.73 A for up to 30 seconds) to overcome cold-coil pull-in currents and brush-motor startup surges without over-sizing the continuous power supply.
- Test, Measurement & Laboratory Benchtop Instruments: Provides low-noise (120 mV pk-pk), tightly regulated (±0.5% line, 1% load) 12 VDC power with EN 55032 Class B EMI performance for oscilloscopes, data loggers, and gas analyzers.
- Building Automation, Access Control & IoT Gateways: Minimizes parasitic standby losses (<0.3 W no-load power) in always-on HVAC controllers, smart metering concentrators, card readers, and Class II ungrounded wall-mount enclosures.
Installation, Thermal Management & MRO Guidelines
Ensure reliable long-term operation and safety compliance by following these PCB layout and thermal management practices:
- PCB Hole Sizing & High-Voltage Creepage Clearance: Lay out the host PCB with four Ø 1.8 mm (0.07 in) plated through-holes on a 72.4 × 15.0 mm grid for the Ø 1.0 mm pins, and maintain at least 6.4 mm primary-to-secondary copper keep-out clearance underneath the open-frame module to preserve its 3000 VAC Class II isolation.
- Convection Airflow & +50 °C Thermal Derating: Allow unobstructed free-air convection around the open-frame components; the unit delivers full 25 W (2.10 A) up to +50 °C (+122 °F) ambient and must be derated linearly at 0.5 W/°C (2.5%/°C) down to 12.5 W (1.05 A) at +70 °C (+158 °F).
- Input Overcurrent & Cold-Start Inrush Coordination: Although the module integrates an internal T2 A / 250 VAC slow-blow fuse on the AC line, size upstream branch circuit breakers or external fuses to withstand the 40 A cold-start inrush peak at 230 VAC without nuisance tripping.
- Peak Load Duty-Cycle Management: When utilizing the 2.73 A (32.76 W) peak load region for inductive loads, ensure peak events stay under 30 seconds at a maximum 10% duty cycle so average output power never exceeds the continuous 25 W thermal rating.