Description
XP Power ECL15US15-P (also known as ECL15US15P) is an ultra-compact 15 W single-output AC-DC power module from the high-density ECL15 series, where the -P suffix designates an open-frame through-hole PCB mount configuration. Operating from a universal 85–264 VAC (120–370 VDC) input, this fixed-frequency 70 kHz switching converter delivers a tightly regulated 15.0 VDC nominal output at 1.00 A continuous current and up to 1.30 A peak current for transient loads under 30 seconds. It achieves 80% typical efficiency, maintains ±1% initial set accuracy with a ±5% onboard voltage trim potentiometer, and consumes less than 0.3 W at no load.
Housed on a miniature 62.0 × 30.7 × 20.0 mm (2.44 × 1.21 × 0.78 in) open-frame PCB footprint weighing just 35 g (0.07 lbs), the module features 4 through-hole solder pins (1.0 mm diameter) and an integrated T2 A / 250 VAC input fuse. Comprehensive fault protection includes 115–140% overvoltage protection, 120–150% overload protection, and auto-recovery hiccup-mode short-circuit protection. Engineered with 3000 VAC Class II double isolation requiring no earth ground, it operates reliably from -20 °C to +70 °C (full load to +50 °C) and carries UL/IEC/EN 62368-1 safety approvals alongside EN 55032 Level B emissions compliance.
Key Features
- High-Density 15 W Output with Peak Surge Capacity: Delivers 15.0 VDC at 1.00 A continuous and 1.30 A peak (<30 s, 10% max duty cycle) in a 5.30 W/in³ open-frame PCB footprint.
- Universal AC & High-Voltage DC Input Range: Accepts 85–264 VAC (47–63 Hz) or 120–370 VDC with 80% efficiency, <0.3 W no-load standby draw, and an integrated T2 A / 250 VAC fuse.
- Precision Voltage Regulation & Onboard Trim: Features ±1% initial accuracy, ±5% output voltage trim potentiometer, ±0.5% line regulation, 1% load regulation, and 120 mV pk-pk maximum ripple and noise.
- Class II 3000 VAC Reinforced Isolation: Eliminates protective earth wiring via double-insulated Class II construction providing 3000 VAC input-to-output galvanic isolation for simplified PCB layouts.
- Comprehensive Fault & Hiccup Protection Suite: Integrates 115–140% Vnom overvoltage protection, 120–150% total power overload limiting, and automatic trip-and-restart hiccup short-circuit protection.
- Wide Industrial Thermal & Altitude Envelope: Convection-cooled operation from -20 °C to +70 °C (-4 °F to +158 °F) with full 15 W output up to +50 °C and 3000 m maximum operating altitude.
- Global ITE/AV Safety & Level B EMC Compliance: Certified to UL/CSA/IEC/EN 62368-1 and IEC 60950-1, meeting EN 55032 Level B conducted/radiated emissions without external filtering components.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | ECL15US15-P |
| Alternate Part Number | ECL15US15P |
| Product Series | ECL15 Series (ECL 5–30W Family) |
| Product Category | PCB Power Modules |
| Component Type | Open-Frame PCB Mount AC-DC Power Supply Module |
| Circuit Topology | Fixed-Frequency PWM Flyback Switching Regulator (70 kHz) |
| Nominal Output Voltage | 15.0 VDC |
| Output Voltage Adjustment Range | ±5% (via onboard V Adj. trim potentiometer) |
| Rated Output Current | 1.00 A |
| Output Current Range | 0 to 1.00 A (no minimum load required) |
| Peak / Surge Output Current | 1.30 A (<30 s duration, max. 10% duty cycle; average power not to exceed 15 W) |
| Rated Output Power | 15 W |
| Peak Output Power | 19.5 W (<30 s duration, max. 10% duty cycle) |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 120 mV pk-pk (20 MHz bandwidth) |
| Output Voltage Tolerance | ±1% (initial set accuracy) |
| Line Regulation | ±0.5% max. |
| Load Regulation | 1% max. |
| Transient Recovery Time & Deviation | 4% max. deviation, recovery to within 1% in 500 µs (for a 25% load step change) |
| Setup Time | 3 s max. (Start-up delay) |
| Rise Time | 14 ms max. |
| Hold-Up Time (at 115 VAC) | 16 ms typical (at full load) |
| AC Input Voltage Range | 85 to 264 VAC |
| DC Input Voltage Range | 120 to 370 VDC |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency | 80% typical |
| AC Input Current (at 230 VAC) | 0.3 A rms |
| Inrush Current (Cold Start at 115 VAC) | 20 A (at 25 °C) |
| Inrush Current (Cold Start at 230 VAC) | 40 A (at 25 °C) |
| No-Load Power Consumption | <0.3 W |
| Switching Frequency | 70 kHz typical |
| Input Fuse Protection | Internal T2 A / 250 VAC fuse |
| Mounting Style | Through-Hole PCB Mount (-P Open Frame) |
| Cooling Method | Free Air Convection |
| Power Density | 5.30 W/in³ |
| Overall Width (W) | 30.7 mm (1.21 in) |
| Overall Height (H) | 20.0 mm max. (0.78 in max.) |
| Overall Depth (D) | 62.0 mm (2.44 in) [Length] |
| Dimensional Tolerance | ±0.5 mm (±0.02 in) for 2-decimal; ±0.25 mm (±0.01 in) for 3-decimal |
| Mounting Hole Pitch | 54.1 × 17.5 mm (2.13 × 0.69 in) pin grid |
| Net Weight | 35 g (0.07 lbs) |
| Termination / Connector Style | 4 × Through-Hole PCB Solder Pins (Ø1.0 mm / Ø0.04 in pins, Ø1.8 mm / Ø0.07 in pads) |
| Pinout Configuration | Input Pins: ACL (AC Line), ACN (AC Neutral) | Output Pins: +Vo (+15 VDC), -Vo (0 V Return) |
| Overload Protection (OLP) Threshold | 120% to 150% of rated total output power |
| Overvoltage Protection (OVP) Threshold | 115% to 140% of nominal output voltage (Vnom) |
| Short Circuit Protection (SCP) | Trip and restart (automatic hiccup mode recovery) |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC |
| Earth Leakage Current | Class II double-insulated construction (no protective earth connection required) |
| Operating Ambient Temperature Range | -20 °C to +70 °C (-4 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) |
| High-Temperature Derating Rate | Linear derating from 100% load (15 W) at +50 °C to 50% load (7.5 W) at +70 °C (2.5% / °C) |
| Operating Altitude | Up to 3000 m (9,842 ft) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | Up to 95% RH, non-condensing |
| Temperature Coefficient | ±0.05% / °C |
| Vibration Resistance | 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins per axis |
| Safety Approvals (UL / North America) | UL 62368-1, CAN/CSA C22.2 No. 62368-1-14 |
| Safety Approvals (IEC / EN / TÜV) | IEC 62368-1:2014, EN 62368-1:2014/A11:2017, IEC 60950-1:2005 Ed. 2 |
| EMC Conducted & Radiated Emissions | EN 55032 Level B (conducted and radiated) |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A (harmonic currents), EN 61000-3-3 (voltage flicker) |
| EMC Immunity Standards | EN 61000-4-2 Level 3 (Perf. Criteria A), EN 61000-4-3 10 V/m 80% mod (Criteria A), EN 61000-4-4 Level 3 (Criteria A), EN 61000-4-5 Installation Class 3 (Criteria A), EN 61000-4-6 10 Vrms (Criteria A), EN 61000-4-8 10 A/m (Criteria A), EN 61000-4-11 Dips & Interruptions (30% 10 ms Criteria A, 60% 100 ms Criteria B, 100% 5000 ms Criteria B) |
| MTBF (MIL-HDBK-217F) | >400,000 hours (at 25 °C, Ground Benign) |
Industrial Applications & Compatible Systems
The XP Power ECL15US15-P provides an isolated, board-level 15 VDC auxiliary bias rail for space-constrained industrial, instrumentation, and commercial electronic assemblies:
- Industrial Automation & PLC I/O Subsystems: Supplies isolated 15 VDC bus power for analog signal conditioning modules, optocoupler arrays, and fieldbus transceiver cards.
- Test, Measurement & Laboratory Instrumentation: Delivers low-ripple (120 mV pk-pk) ±15 VDC or single-rail bias power for precision operational amplifiers, sensor bridges, and benchtop analyzers.
- Smart Building & HVAC Control Boards: Integrates directly onto main control PCBs to power 15 VDC relay coils, damper actuator drivers, and environmental monitoring controllers.
- Embedded Telecom & Security Access Controllers: Fits compact 1U/wall-mount enclosures requiring Class II double-insulated AC-DC conversion without a chassis earth connection.
Installation, Thermal Management & MRO Guidelines
Follow these board-layout and thermal integration practices to maintain 3000 VAC isolation and long-term reliability:
- Primary-to-Secondary PCB Creepage & Clearance: Maintain at least 6.4 mm creepage and clearance on the host PCB between primary input pins (ACL/ACN) and secondary output traces (+Vo/-Vo) to preserve IEC 62368-1 Class II reinforced isolation.
- Convection Airflow & Thermal Derating: Provide unobstructed free-air convection around the open-frame module; limit continuous load linearly from 15 W at +50 °C down to 7.5 W at +70 °C ambient.
- Inrush Current & Upstream Overcurrent Coordination: Account for 40 A cold-start inrush at 230 VAC when selecting upstream circuit breakers, noting that an internal T2 A / 250 VAC slow-blow fuse is already integrated on-board.
- Wave Soldering & Mechanical Support: Solder the four 1.0 mm diameter pins into 1.8 mm PCB pads and avoid applying downward mechanical pressure on the open-frame magnetic components during board handling.