PBR650PS48C XP Power 650W 48VDC Medical Enclosed PSU

$312.03

XP Power PBR650PS48C 650W 48VDC 13.55A medical enclosed AC-DC power supply, 80-264VAC input, featuring 2xMOPP BF isolation, 5V standby, and Class B EMI.

SKU: PBR650PS48C Category: Brand:

Description

XP Power PBR650PS48C is an industrial and medical-grade enclosed AC-DC switching power supply from the high-density PBR650 series, where the PS48 designation specifies a regulated 48.0 VDC main output and the C suffix denotes an enclosed metal chassis with an integral temperature-controlled cooling fan. Engineered with an active power factor correction (PFC) front end (fixed 65 kHz switching) and a variable-frequency main converter stage (90 to 300 kHz), it delivers 13.55 A nominal continuous current (650 W) and up to 15.00 A peak current (720 W for up to 15 seconds), alongside a dedicated 5.0 VDC / 0.2 A standby rail. Operating across a universal 80 to 264 VAC (47–63 Hz) input window with up to 90% typical efficiency, the supply maintains tight ±2% combined line and load tolerance, fast transient recovery within 500 µs for a 25% load step, and low maximum ripple and noise of 480 mV pk-pk.

Housed in a compact 203.2 × 101.6 × 65.5 mm (8.00 × 4.00 × 2.58 in) enclosed footprint, the unit integrates heavy-duty Dinkle screw terminal blocks (P1 input and P2 output) and a 10-pin JST S10B-PHDSS control header (P3) supporting remote sense, TTL inhibit, and AC OK power-good signaling. Comprehensive self-protection includes 115–140% trip-and-restart overcurrent protection, 115–140% latching overvoltage protection, and latching thermal shutdown. Designed for Body Floating (BF) medical equipment, it provides reinforced 4000 VAC (2 × MOPP) input-to-output isolation, 1500 VAC (1 × MOPP) input-to-ground and output-to-ground isolation, and ultra-low 50 µA typical (80 µA max) patient leakage current. It delivers full 650 W output from -10 °C to +50 °C (derating linearly to 50% at +70 °C) and holds full IEC/ES/CSA/EN 60601-1 medical safety approvals alongside EN 55011/32 Class B conducted and radiated emissions compliance.

Key Features

  • High-Density 48VDC Main & Peak Output: Delivers 48.0 VDC at 13.55 A continuous current (650 W nominal) and 15.00 A peak current (720 W for up to 15 seconds at 10% duty cycle) for motor and actuator surges.
  • Medical BF-Ready 2xMOPP Reinforced Isolation: Engineered with 4000 VAC (2 x MOPP) input-to-output and 1500 VAC (1 x MOPP) output-to-ground isolation, maintaining ultra-low 50 µA typical (80 µA max) patient leakage current at 264 VAC.
  • Auxiliary 5VDC Standby & Remote Control Suite: Includes an independent 5.0 VDC / 200 mA standby rail plus a 10-pin JST P3 signal interface providing remote sense (0.5 VDC drop compensation), TTL remote inhibit, and AC OK status.
  • Acoustic-Optimized Thermal Fan Control: Equipped with an integral temperature-controlled cooling fan monitored via internal transformer T1 that remains off below +60 °C and scales linearly to full speed at +80 °C.
  • Low-Noise Regulation & Fast Transient Recovery: Limits maximum output ripple and noise to 480 mV pk-pk (20 MHz bandwidth) with ±2% total regulation tolerance and under 500 µs recovery within 1% for 25% load steps.
  • Class B EMI & Full Medical Safety Approvals: Certified to IEC 60601-1, ANSI/AAMI ES60601-1, CSA C22.2 No. 60601-1, and EN 60601-1 with EN 55011 / EN 55032 Class B conducted and radiated EMC compliance.
  • Wide-Temperature Industrial & Healthcare Reliability: Operates across -10 °C to +70 °C ambient temperatures with 100% full-load capability up to +50 °C, 90% typical efficiency at 230 VAC, and 190,000-hour MIL-HDBK-217F MTBF.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) PBR650PS48C
Product Series PBR650 Series
Product Category Medical Enclosed PSUs
Component Type Enclosed Fan-Cooled Medical & ITE AC-DC Power Supply
Circuit Topology Switched-Mode Power Supply (SMPS) with Active PFC, Variable-Frequency Main Stage, and Burst-Mode No-Load Energy Saving
Nominal Output Voltage 48.0 VDC (Main V1) / 5.0 VDC (Standby V2)
Rated Output Current 13.55 A (Main V1 at 48.0 VDC) / 0.2 A (Standby V2 at 5.0 VDC)
Peak / Surge Output Current 15.00 A (for 15 s max., 10% duty cycle, average power not to exceed nominal rating)
Rated Output Power 650 W (Enclosed fan-cooled continuous rating)
Peak Output Power 720 W (48.0 VDC at 15.00 A peak for up to 15 s)
Number of Outputs 2 (1 Main Regulated 48 VDC Output + 1 Auxiliary 5 VDC Standby Output)
Output Ripple & Noise (Max.) 480 mV pk-pk (1% pk-pk max., 20 MHz bandwidth with 10 µF tantalum and 0.1 µF ceramic parallel capacitors)
Output Voltage Tolerance ±2% (Combined line and load regulation, 0.1% minimum load required to meet specification)
Transient Recovery Time & Deviation 4% max. deviation, recovery within 1% in less than 500 µs (for a 25% step load change)
Hold-Up Time (at 115 VAC) 12 ms min. / 20 ms typ. (measured at 110 VAC, 650 W full load)
AC Input Voltage Range 80 to 264 VAC (Universal input; derate output power to 90% at 85 VAC and 80% at 80 VAC)
Input Frequency Range 47 to 63 Hz
Efficiency (at 230 VAC) 90% typ. (at 230 VAC, 100% full load)
AC Input Current (at 115 VAC) 8.4 A rms (at 115 VAC, 60 Hz, full load)
AC Input Current (at 230 VAC) 4.2 A rms (at 230 VAC, 50 Hz, full load)
Inrush Current (Cold Start at 115 VAC) 30 A peak (at 115 VAC, +25 °C cold start)
Inrush Current (Cold Start at 230 VAC) 60 A peak (at 230 VAC, +25 °C cold start)
Power Factor Correction (PFC) Active PFC (EN 61000-3-2 Class A harmonic current compliance)
Switching Frequency 55 to 75 kHz, 65 kHz typ. (PFC, fixed) / 90 to 300 kHz (Main converter, variable) / 124 to 140 kHz, 132 kHz typ. (Standby, variable)
Mounting Style Chassis Mount (8 × M3×0.5 threaded mounting inserts; 4 mm max. screw penetration)
Cooling Method Forced Air via Integral Temperature-Controlled Fan (starts at T1 transformer temp ~+60 °C, full speed at ~+80 °C)
Enclosure Case Number Suffix C (Enclosed Chassis with Built-In End Fan)
Overall Width (W) 101.6 mm (4.00 in)
Overall Height (H) 65.5 mm (2.58 in)
Overall Depth (D) 203.2 mm (8.00 in)
Dimensional Tolerance ±0.5 mm (±0.02 in) maximum
Mounting Hole Pitch 165.8 × 72.6 mm (6.53 × 2.86 in) bottom pattern; 49.5 mm (1.95 in) side vertical spacing
Net Weight 1.4 kg (3.1 lbs) approx. (Mechanical drawing note) / 2000 g (4.4 lbs) (General table rating)
Termination / Connector Style Input P1: Dinkle DT-35C-B01W-03 (M3 nickel-plated screws); Output P2: Dinkle DT-4N-B01W-06 (M3.5 nickel-plated screws); Signals P3: 10-Pin JST S10B-PHDSS Header (mates with JST PHDR-10VS)
Input Terminal Pinout Input Connector P1 (3-Pin Screw Terminal): Pin 1 = Ground (G), Pin 2 = Line (L), Pin 3 = Neutral (N)
Output & Signal Terminal Pinout Output Connector P2 (6-Pin Screw Terminal): Pins 1–3 = +V1 (+48 VDC), Pins 4–6 = Com (Return); Signal Connector P3 (10-Pin JST): Pin 1 = +V1 Sense, Pin 2 = -V1 Sense, Pin 3 = AC OK, Pin 4 = Common Return, Pins 5/6/8 = N/C, Pin 7 = Inhibit, Pin 9 = +5 VDC Standby, Pin 10 = +5 VDC Standby Return
Control & Monitoring Signals Remote Sense (compensates up to 0.5 VDC total drop), Remote Inhibit (apply TTL High to inhibit output), AC OK (TTL High normal, Low on AC loss; 100–1000 ms turn-on delay, >=1 ms turn-off warning), Vadj Potentiometer
Overload Protection (OLP) Threshold 115% to 140% of rated output current
Overload Protection (OLP) Mode Trip and restart (Hiccup / auto-recovery characteristic)
Overvoltage Protection (OVP) Threshold 115% to 140% of nominal output voltage
Overvoltage Protection (OVP) Mode Latching shutdown (requires AC input power recycle to reset)
Overtemperature Protection (OTP) Mode Latching thermal shutdown
Withstand Isolation Voltage (I/P to O/P) 4000 VAC (2 × MOPP medical reinforced isolation)
Withstand Isolation Voltage (I/P to FG / Case) 1500 VAC (1 × MOPP medical isolation)
Withstand Isolation Voltage (O/P to FG / Case) 1500 VAC (1 × MOPP medical isolation, BF rated)
Earth Leakage Current 225 µA typ. / 275 µA max. (at 264 VAC, 60 Hz); Patient Leakage Current: 50 µA typ. / 80 µA max. (at 264 VAC, 63 Hz)
Medical Isolation Rating BF (Body Floating) Applied Part Ready; 2 × MOPP (Input to Output), 1 × MOPP (Input to Ground), 1 × MOPP (Output to Ground)
Operating Ambient Temperature Range -10 °C to +70 °C (+14 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 100% load (650 W)
High-Temperature Derating Rate Derate linearly at 2.5% per °C from 100% load at +50 °C to 50% load (325 W) at +70 °C
Low-Line Input Derating Derate output power to 90% at 85 VAC and 80% at 80 VAC
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 5% to 95% RH (Non-condensing)
Temperature Coefficient ±0.04% / °C
Safety Approvals (UL / North America) UL ANSI/AAMI ES60601-1, CSA C22.2 No. 60601-1 (Medical Electrical Equipment)
Safety Approvals (IEC / EN / TÜV) CB Certified to IEC 60601-1, EN 60601-1 (Medical & ITE Safety Approvals)
Safety Approvals (Regional / Global) CE Marked, UKCA Marked (Meets all applicable directives and legislation)
EMC Conducted & Radiated Emissions EN 55011 Class B, EN 55032 Class B (Conducted and Radiated Emissions)
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A (Harmonic Current), EN 61000-3-3 (Voltage Flicker)
EMC Immunity Standards EN 61000-4-2 ESD Level 4 (±8 kV contact, ±15 kV air, Criteria A), EN 61000-4-3 Radiated (10 V/m, Criteria A), EN 61000-4-4 EFT (±2 kV, Criteria A), EN 61000-4-5 Surge Installation Class 3 (±1 kV differential, ±2 kV common mode, Criteria A), EN 61000-4-6 Conducted RF (10 Vrms, Criteria A), EN 61000-4-8 Magnetic Fields (30 A/m, Criteria A), Voltage Dips & Interruptions (100 VAC & 230 VAC per datasheet schedule, Criteria A/B)
MTBF (MIL-HDBK-217F) 190,000 Hours (0.19 Mhrs per MIL-HDBK-217F, Ground Benign, full load at +25 °C)
Environmental Compliance RoHS, CE & UKCA Compliant

Industrial Applications & Compatible Systems

XP Power PBR650PS48C is engineered for medical, laboratory, and high-reliability industrial systems requiring a regulated 48 VDC bus with Body Floating (BF) patient isolation and Class B electromagnetic compatibility:

  • Body Floating (BF) Medical & Healthcare Equipment: Powers surgical tables, diagnostic ultrasound systems, patient therapy consoles, and medical lasers requiring 2 × MOPP input-to-output isolation, 1500 VAC output-to-ground isolation, and under 80 µA patient leakage current.
  • Industrial Robotics & Motion Control Actuators: Drives 48 VDC servo amplifiers, stepper motor buses, and robotic arms utilizing the 13.55 A continuous rating and 15.00 A (720 W) 15-second peak current capability to absorb dynamic acceleration surges.
  • Precision Analytical & Laboratory Instrumentation: Supplies low-noise 48 VDC power (480 mV pk-pk max ripple, EN 55011/32 Class B emissions) to mass spectrometers, automated clinical analyzers, and optical inspection platforms.
  • Process Control, IIoT Gateways & PoE/Telecom Subsystems: Provides primary 48 VDC bus power alongside an always-on 5 VDC / 200 mA standby rail and TTL AC OK/inhibit signaling for automated test equipment (ATE) and industrial control cabinets.

Installation, Thermal Management & MRO Guidelines

Ensure long-term field reliability and medical safety compliance by observing these mechanical and electrical integration practices:

  • Chassis Mounting & Screw Penetration Clearance: Secure the enclosure using the eight M3×0.5 threaded mounting inserts, strictly limiting mounting screw penetration to a maximum of 4.0 mm from the outer chassis surface to avoid compromising internal 1 × MOPP creepage barriers.
  • Remote Sense & High-Current Output Wiring: Distribute the 13.55 A load across all three +V1 pins (Pins 1–3) and three Com pins (Pins 4–6) on the Dinkle DT-4N-B01W-06 P2 terminal block, and connect P3 Pins 1 and 2 (+V1/-V1 Sense) at the point of load to compensate for up to 0.5 VDC of cable drop.
  • Thermal Derating & Burst-Mode No-Load Behavior: Maintain unobstructed airflow around the integral fan intake and exhaust; apply a 2.5% per °C linear load derating above +50 °C (down to 325 W at +70 °C), and apply at least 0.1% minimum load (~14 mA) whenever tight ±2% voltage regulation is required over burst-mode energy-saving operation.
  • Medical Single-Fuse Ordering Note: Standard PBR650PS48C units include dual input fusing; if your specific IEC 60601-1 system architecture mandates single-pole fusing on the Live conductor only, specify factory suffix -SP (PBR650PS48C-SP).