Description
TRACO Power TEN 40-4811WIR (also known as TEN404811WIR) is an industrial and railway-grade 40 W isolated DC-DC converter module from the high-performance TEN 40WIR series, where the nomenclature denotes a 40 Watt output rating, a 48 VDC nominal ultra-wide 4:1 input (18–75 VDC), a single 5 VDC output, and ruggedized railway approval (WIR). Utilizing a pulse-width modulated (PWM) flyback converter topology switching at 250 kHz typical with an internal Pi-type input filter, this module delivers up to 8,000 mA (8.0 A) of regulated current with zero minimum load requirements and a high 91% typical conversion efficiency. It maintains tight output stability with ±1% maximum voltage set accuracy, 0.2% maximum line regulation, 0.5% maximum load regulation, and a low output ripple and noise profile of 75 mVp-p typical (100 mVp-p max.) across a 20 MHz bandwidth. Furthermore, the single 5 VDC output supports ±10% external resistor voltage trimming (4.5 to 5.5 VDC), handles up to 20,000 µF maximum capacitive load, and draws just 10 mA typical no-load input current to preserve battery-backed buses.
Housed in an industry-standard 2″ × 1″ × 0.4″ (50.8 × 25.4 × 10.2 mm) shielded copper metal package weighing 32 g (1.13 oz) with a non-conductive UL 94 V-0 FR4 insulated baseplate and silicone potting, the converter mounts via 6-pin through-hole PCB pins (Pin 1: +Vin, Pin 2: -Vin, Pin 3: Remote On/Off, Pin 4: +Vout, Pin 5: -Vout, Pin 6: Trim). Comprehensive onboard safeguards include an input undervoltage lockout (UVLO) circuit (16 VDC typical shutdown), continuous short-circuit protection (SCP) with automatic recovery, indefinite-mode overload current limitation at 150% typical of rated output, and Zener-clamped overvoltage protection (OVP) at 125% typical of nominal voltage. Providing 1,600 VDC input-to-output galvanic isolation, the unit operates across an extended -40 °C to +85 °C (-40 °F to +185 °F) ambient temperature range (expandable up to +95 °C with optional clip-on heatsinks) and is fully certified to EN 50155, EN 50121-3-2, EN 61373, EN 45545-2, and UL/IEC/EN 62368-1.
Key Features
- Ultra-Wide 4:1 Railway Input Range: Operates seamlessly across an 18 to 75 VDC input bus (48 VDC nominal) with 100 VDC 1-second surge withstand and integrated 16 VDC typical undervoltage lockout (UVLO).
- High-Current 5 VDC / 8 A Regulated Output: Delivers 40 W rated power at 5 VDC (8,000 mA max.) with ±1% voltage accuracy, 0.2% line regulation, 0.5% load regulation, and ±10% external voltage trim adjustability.
- 91% Conversion Efficiency & Low Idle Draw: Achieves 91% typical efficiency alongside an ultra-low 10 mA typical no-load input current and 3 mA maximum remote-off idle draw for battery-powered systems.
- Low Output Ripple & High Capacitive Drive: Suppresses output ripple and noise to 75 mVp-p typical (100 mVp-p max. at 20 MHz bandwidth) while reliably starting into capacitive loads up to 20,000 µF.
- EN 50155, EN 61373 & EN 45545-2 Certified: Fully qualified for rolling stock applications, meeting EN 50155 electrical profiles, EN 50121-3-2 EMC immunity, EN 61373/MIL-STD-810F mechanical shock/vibration, and EN 45545-2 fire safety.
- Complete Self-Recovering Protection Suite: Integrates continuous short-circuit protection with automatic recovery, indefinite-mode overload current limiting (125–210% Iout max.), and 125% typical Zener diode overvoltage clamping.
- Compact 2″ × 1″ Shielded Copper Package: Encapsulated in a 50.8 × 25.4 × 10.2 mm copper housing with UL 94 V-0 silicone potting, 1,600 VDC I/O isolation, and an insulated FR4 baseplate.
- Extended -40 °C to +85 °C Thermal Envelope: Designed for harsh ambient environments up to +105 °C maximum case temperature, with optional TEN-HS1/HS8/HS9/HS10 heatsinks extending ambient ceilings up to +95 °C.
Technical Specifications
| Manufacturer | TRACO Power |
|---|---|
| Manufacturer Part Number (MPN) | TEN 40-4811WIR |
| Alternate Part Number | TEN404811WIR |
| Compatible Equipment / Series | Optional Heatsinks: TEN-HS1 (0.22 in), TEN-HS8 (0.3 in), TEN-HS9 (0.5 in), TEN-HS10 (0.8 in) |
| Product Series | TEN 40WIR Series |
| Product Category | Converter Heatsinks |
| Component Type | Isolated Board-Mount Railway DC-DC Converter |
| Circuit Topology | Flyback Converter (PWM Regulated) |
| Nominal Output Voltage | 5 VDC (Single Output) |
| Output Voltage Trim / Adjustment Range | ±10% (4.5 to 5.5 VDC via external trim resistor; output power must not exceed 40 W) |
| Rated Output Current | 8,000 mA (8.0 A) |
| Minimum Load Current | 0 mA |
| Rated Output Power | 40 W |
| Output Ripple & Noise (Max.) | 100 mVp-p max. / 75 mVp-p typ. (20 MHz bandwidth, measured with 0.1 µF, 50 V X7R capacitor) |
| Output Voltage Tolerance | ±1.0% max. (Voltage Set Accuracy) |
| Line Regulation | 0.2% max. (Vmin to Vmax input variation) |
| Load Regulation | 0.5% max. (0% to 100% load variation) |
| Transient Recovery Time & Deviation | 250 µs typ. recovery time / 10% max. response deviation (for 25% load step) |
| Setup Time | 60 ms typ. (Start-up Time) |
| Hold-Up Time | 10 ms min. (acc. to EN 50155 Class S2 with external input capacitor) |
| Max. Capacitive Load | 20,000 µF max. |
| DC Input Voltage Range | 18 to 75 VDC (100 VDC max. surge voltage for 1 s max.) |
| Nominal Input Voltage | 48 VDC |
| Wide Input Ratio | 4:1 |
| Undervoltage Shutdown (UVLO) | 15.0 VDC min. / 16.0 VDC typ. / 17.5 VDC max. |
| Efficiency | 91% typ. (at 48 VDC nominal input, full resistive load) |
| DC Input Current (Full Load / No Load) | 10 mA typ. (at no load) / 3 mA max. (Remote Off idle input current) |
| Reflected Input Ripple Current | 20 mAp-p typ. (Internal Pi-Type input filter) |
| Recommended Input Fuse | 4,000 mA (4.0 A) Slow Blow external fuse |
| Switching Frequency | 225 to 275 kHz (250 kHz typ., PWM) |
| Mounting Style | Through-Hole PCB Mount (THD) |
| Cooling Method | Natural Convection (20 LFM; optional clip-on heatsinks available) |
| Package / Footprint Standard | 2″ × 1″ Standard Metal Case |
| Overall Width (W) | 50.8 mm (2.00 in) |
| Overall Height (H) | 10.2 mm (0.40 in) |
| Overall Depth (D) | 25.4 mm (1.00 in) |
| Dimensional Tolerance | x.x: ±0.50 mm (±0.02 in); x.xx: ±0.25 mm (±0.01 in); Pin pitch: ±0.25 mm (±0.01 in); Pin Ø: ±0.10 mm (±0.004 in) |
| Net Weight | 32 g (1.13 oz / 0.071 lbs) |
| Termination / Connector Style | Solder Pins, Ø 1.0 mm (0.04 in), length 5.6 mm (0.22 in), Copper with Nickel (2–3 µm) & Matte Tin (3–5 µm) plating; Lead-free wave soldering 265 °C / 10 s max. |
| Pinout Configuration | Pin 1: +Vin (Vcc); Pin 2: -Vin (GND); Pin 3: Remote On/Off; Pin 4: +Vout; Pin 5: -Vout; Pin 6: Trim |
| Control & Monitoring Signals | Remote On/Off (Refers to Pin 3 ‘Remote’ and Pin 2 ‘-Vin’: On = 3.0 to 12 VDC or open circuit [passive = on]; Off = 0 to 1.2 VDC or short circuit; Remote pin current: -0.5 to +0.5 mA) |
| Enclosure / Potting Material | Copper metal housing, Non-conductive FR4 insulated baseplate (UL 94 V-0), Silicone potting (UL 94 V-0) |
| Overload Protection (OLP) Threshold | 125% to 210% of Iout max. (150% typ.) |
| Overload Protection (OLP) Mode | Indefinite Mode (Current Limitation) |
| Overvoltage Protection (OVP) Threshold | 125% typ. of Vout nom. (6.25 VDC typ.) |
| Overvoltage Protection (OVP) Mode | Internal Zener Diode Clamp |
| Short Circuit Protection (SCP) | Continuous, Automatic Recovery |
| Withstand Isolation Voltage (I/P to O/P) | 1,600 VDC (60 s test duration, Functional Insulation) |
| Isolation Resistance (at 500 VDC) | 1,000 MΩ min. (Input to Output) |
| Isolation Capacitance | 1,500 pF max. (Input to Output, at 100 kHz, 1 V) |
| Operating Ambient Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F); up to +87 °C with TEN-HS1, +90 °C with TEN-HS8, +92 °C with TEN-HS9, +95 °C with TEN-HS10; Max. Case Temp: +105 °C (+221 °F) |
| High-Temperature Derating Rate | Case-to-Ambient Thermal Impedance: 10.8 K/W typ. (standalone) / 10.3 K/W typ. (with heatsink TEN-HS1) |
| Altitude Derating | 5,000 m (16,404 ft) max. operating altitude |
| Storage Temperature Range | -55 °C to +125 °C (-67 °F to +257 °F) |
| Operating Relative Humidity | 95% RH max. (non-condensing, Pollution Degree PD 2) |
| Temperature Coefficient | ±0.02 %/K max. |
| Vibration Resistance | EN 61373 & MIL-STD-810F (Vibration, Mechanical Shock & Thermal Shock certified) |
| Flammability Rating | EN 45545-2 (Railway Fire & Smoke Protection) & UL 94 V-0 (Baseplate & Silicone Potting) |
| Safety Approvals (UL / North America) | UL 62368-1, UL 60950-1 |
| Safety Approvals (IEC / EN / TÜV) | EN 50155 (Railway), IEC 62368-1, EN 62368-1 (Output classified ES1 / PS3), IEC 60950-1, EN 60950-1 |
| EMC Conducted & Radiated Emissions | EN 50121-3-2 (Rolling Stock), EN 55032 Class A & Class B (Conducted & Radiated with external filter) |
| EMC Immunity Standards | EN 50121-3-2, EN 61000-4-2 (ESD ±8 kV Air / ±6 kV Contact, Criteria A), EN 61000-4-3 (RF Field 20 V/m, Criteria A), EN 61000-4-4 (EFT ±2 kV, Criteria A), EN 61000-4-5 (Surge ±2 kV with 220 µF 100 V KY || SMDJ120A, Criteria A), EN 61000-4-6 (Conducted RF 10 Vrms, Criteria A), EN 61000-4-8 (Magnetic Field 100 A/m cont. / 1000 A/m 1 s, Criteria A) |
| MTBF (MIL-HDBK-217F) | 900,000 hours (Ground Benign at +25 °C) |
| Environmental Compliance | RoHS Compliant (with exemptions 7(a), 7(c)-I), REACH SVHC & Annex XVII Compliant (SCIP: 00c7ae30-3d8c-4682-88e1-0d2e69ce3142) |
Industrial Applications & Compatible Systems
Engineered for harsh transportation and industrial control environments, the TRACO Power TEN 40-4811WIR provides high-density, transient-immune 5 VDC power conversion across critical subsystems:
- Railway & Rolling Stock Electronics: Powers onboard train control and monitoring systems (TCMS), passenger information displays, cab signaling consoles, and wayside transceivers requiring strict EN 50155, EN 50121-3-2, and EN 45545-2 compliance.
- 48 VDC Telecom & Wireless Base Stations: Steps down 48 VDC nominal (18–75 VDC) telecom battery buses to a tightly regulated 5 VDC / 8 A rail for cellular backhaul routers, optical transceivers, and remote radio heads.
- Battery-Operated Mobile Machinery & AGVs: Ideal for autonomous guided vehicles, heavy construction equipment, and mobile robotics where the 10 mA typical no-load current and remote On/Off pin (3 mA idle) prevent battery drain during standby.
- Industrial Automation & Test Instrumentation: Supplies low-noise (75 mVp-p typical), galvanically isolated 1,600 VDC logic power to FPGA/DSP boards, PLC I/O backplanes, and precision data acquisition equipment.
Installation, Thermal Management & MRO Guidelines
To ensure long-term operational reliability and full regulatory compliance during PCB layout and system integration, observe these critical engineering guidelines:
- External Input Fuse & Surge Protection Network: Install a 4,000 mA (4 A) slow-blow fuse in series with the +Vin line, and connect a parallel 220 µF / 100 V Nippon Chemi-Con KY capacitor with an SMDJ120A TVS diode across the input terminals to meet EN 61000-4-4/5 (±2 kV) immunity criteria.
- PCB Trace Routing & Wave Soldering Limits: Avoid routing exposed PCB signal traces directly underneath the converter body, and restrict lead-free wave soldering profiles to a maximum of 265 °C for 10 seconds on the Ø 1.0 mm matte-tin pins.
- Thermal Management & Output Voltage Trimming: Maintain at least 20 LFM natural convection and keep the copper case below +105 °C (attach clip-on heatsinks TEN-HS1, TEN-HS8, TEN-HS9, or TEN-HS10 for elevated ambient operation up to +95 °C); when trimming Vout up to +10% via Pin 6, ensure total load power never exceeds 40 W.