TEN 40-4811WIR TRACO Power 40W 5VDC DC-DC Converter

$102.87

TRACO Power TEN 40-4811WIR (TEN404811WIR) 40W 5VDC 8A isolated through-hole DC-DC converter, 18-75VDC 4:1 input, 2×1 inch metal case, EN 50155 railway approved.

SKU: TEN 40-4811WIR Category: Brand:

Description

TRACO Power TEN 40-4811WIR (also known as TEN404811WIR) is an industrial and railway-grade 40 W isolated DC-DC converter module from the high-performance TEN 40WIR series, where the nomenclature denotes a 40 Watt output rating, a 48 VDC nominal ultra-wide 4:1 input (18–75 VDC), a single 5 VDC output, and ruggedized railway approval (WIR). Utilizing a pulse-width modulated (PWM) flyback converter topology switching at 250 kHz typical with an internal Pi-type input filter, this module delivers up to 8,000 mA (8.0 A) of regulated current with zero minimum load requirements and a high 91% typical conversion efficiency. It maintains tight output stability with ±1% maximum voltage set accuracy, 0.2% maximum line regulation, 0.5% maximum load regulation, and a low output ripple and noise profile of 75 mVp-p typical (100 mVp-p max.) across a 20 MHz bandwidth. Furthermore, the single 5 VDC output supports ±10% external resistor voltage trimming (4.5 to 5.5 VDC), handles up to 20,000 µF maximum capacitive load, and draws just 10 mA typical no-load input current to preserve battery-backed buses.

Housed in an industry-standard 2″ × 1″ × 0.4″ (50.8 × 25.4 × 10.2 mm) shielded copper metal package weighing 32 g (1.13 oz) with a non-conductive UL 94 V-0 FR4 insulated baseplate and silicone potting, the converter mounts via 6-pin through-hole PCB pins (Pin 1: +Vin, Pin 2: -Vin, Pin 3: Remote On/Off, Pin 4: +Vout, Pin 5: -Vout, Pin 6: Trim). Comprehensive onboard safeguards include an input undervoltage lockout (UVLO) circuit (16 VDC typical shutdown), continuous short-circuit protection (SCP) with automatic recovery, indefinite-mode overload current limitation at 150% typical of rated output, and Zener-clamped overvoltage protection (OVP) at 125% typical of nominal voltage. Providing 1,600 VDC input-to-output galvanic isolation, the unit operates across an extended -40 °C to +85 °C (-40 °F to +185 °F) ambient temperature range (expandable up to +95 °C with optional clip-on heatsinks) and is fully certified to EN 50155, EN 50121-3-2, EN 61373, EN 45545-2, and UL/IEC/EN 62368-1.

Key Features

  • Ultra-Wide 4:1 Railway Input Range: Operates seamlessly across an 18 to 75 VDC input bus (48 VDC nominal) with 100 VDC 1-second surge withstand and integrated 16 VDC typical undervoltage lockout (UVLO).
  • High-Current 5 VDC / 8 A Regulated Output: Delivers 40 W rated power at 5 VDC (8,000 mA max.) with ±1% voltage accuracy, 0.2% line regulation, 0.5% load regulation, and ±10% external voltage trim adjustability.
  • 91% Conversion Efficiency & Low Idle Draw: Achieves 91% typical efficiency alongside an ultra-low 10 mA typical no-load input current and 3 mA maximum remote-off idle draw for battery-powered systems.
  • Low Output Ripple & High Capacitive Drive: Suppresses output ripple and noise to 75 mVp-p typical (100 mVp-p max. at 20 MHz bandwidth) while reliably starting into capacitive loads up to 20,000 µF.
  • EN 50155, EN 61373 & EN 45545-2 Certified: Fully qualified for rolling stock applications, meeting EN 50155 electrical profiles, EN 50121-3-2 EMC immunity, EN 61373/MIL-STD-810F mechanical shock/vibration, and EN 45545-2 fire safety.
  • Complete Self-Recovering Protection Suite: Integrates continuous short-circuit protection with automatic recovery, indefinite-mode overload current limiting (125–210% Iout max.), and 125% typical Zener diode overvoltage clamping.
  • Compact 2″ × 1″ Shielded Copper Package: Encapsulated in a 50.8 × 25.4 × 10.2 mm copper housing with UL 94 V-0 silicone potting, 1,600 VDC I/O isolation, and an insulated FR4 baseplate.
  • Extended -40 °C to +85 °C Thermal Envelope: Designed for harsh ambient environments up to +105 °C maximum case temperature, with optional TEN-HS1/HS8/HS9/HS10 heatsinks extending ambient ceilings up to +95 °C.

Technical Specifications

Manufacturer TRACO Power
Manufacturer Part Number (MPN) TEN 40-4811WIR
Alternate Part Number TEN404811WIR
Compatible Equipment / Series Optional Heatsinks: TEN-HS1 (0.22 in), TEN-HS8 (0.3 in), TEN-HS9 (0.5 in), TEN-HS10 (0.8 in)
Product Series TEN 40WIR Series
Product Category Converter Heatsinks
Component Type Isolated Board-Mount Railway DC-DC Converter
Circuit Topology Flyback Converter (PWM Regulated)
Nominal Output Voltage 5 VDC (Single Output)
Output Voltage Trim / Adjustment Range ±10% (4.5 to 5.5 VDC via external trim resistor; output power must not exceed 40 W)
Rated Output Current 8,000 mA (8.0 A)
Minimum Load Current 0 mA
Rated Output Power 40 W
Output Ripple & Noise (Max.) 100 mVp-p max. / 75 mVp-p typ. (20 MHz bandwidth, measured with 0.1 µF, 50 V X7R capacitor)
Output Voltage Tolerance ±1.0% max. (Voltage Set Accuracy)
Line Regulation 0.2% max. (Vmin to Vmax input variation)
Load Regulation 0.5% max. (0% to 100% load variation)
Transient Recovery Time & Deviation 250 µs typ. recovery time / 10% max. response deviation (for 25% load step)
Setup Time 60 ms typ. (Start-up Time)
Hold-Up Time 10 ms min. (acc. to EN 50155 Class S2 with external input capacitor)
Max. Capacitive Load 20,000 µF max.
DC Input Voltage Range 18 to 75 VDC (100 VDC max. surge voltage for 1 s max.)
Nominal Input Voltage 48 VDC
Wide Input Ratio 4:1
Undervoltage Shutdown (UVLO) 15.0 VDC min. / 16.0 VDC typ. / 17.5 VDC max.
Efficiency 91% typ. (at 48 VDC nominal input, full resistive load)
DC Input Current (Full Load / No Load) 10 mA typ. (at no load) / 3 mA max. (Remote Off idle input current)
Reflected Input Ripple Current 20 mAp-p typ. (Internal Pi-Type input filter)
Recommended Input Fuse 4,000 mA (4.0 A) Slow Blow external fuse
Switching Frequency 225 to 275 kHz (250 kHz typ., PWM)
Mounting Style Through-Hole PCB Mount (THD)
Cooling Method Natural Convection (20 LFM; optional clip-on heatsinks available)
Package / Footprint Standard 2″ × 1″ Standard Metal Case
Overall Width (W) 50.8 mm (2.00 in)
Overall Height (H) 10.2 mm (0.40 in)
Overall Depth (D) 25.4 mm (1.00 in)
Dimensional Tolerance x.x: ±0.50 mm (±0.02 in); x.xx: ±0.25 mm (±0.01 in); Pin pitch: ±0.25 mm (±0.01 in); Pin Ø: ±0.10 mm (±0.004 in)
Net Weight 32 g (1.13 oz / 0.071 lbs)
Termination / Connector Style Solder Pins, Ø 1.0 mm (0.04 in), length 5.6 mm (0.22 in), Copper with Nickel (2–3 µm) & Matte Tin (3–5 µm) plating; Lead-free wave soldering 265 °C / 10 s max.
Pinout Configuration Pin 1: +Vin (Vcc); Pin 2: -Vin (GND); Pin 3: Remote On/Off; Pin 4: +Vout; Pin 5: -Vout; Pin 6: Trim
Control & Monitoring Signals Remote On/Off (Refers to Pin 3 ‘Remote’ and Pin 2 ‘-Vin’: On = 3.0 to 12 VDC or open circuit [passive = on]; Off = 0 to 1.2 VDC or short circuit; Remote pin current: -0.5 to +0.5 mA)
Enclosure / Potting Material Copper metal housing, Non-conductive FR4 insulated baseplate (UL 94 V-0), Silicone potting (UL 94 V-0)
Overload Protection (OLP) Threshold 125% to 210% of Iout max. (150% typ.)
Overload Protection (OLP) Mode Indefinite Mode (Current Limitation)
Overvoltage Protection (OVP) Threshold 125% typ. of Vout nom. (6.25 VDC typ.)
Overvoltage Protection (OVP) Mode Internal Zener Diode Clamp
Short Circuit Protection (SCP) Continuous, Automatic Recovery
Withstand Isolation Voltage (I/P to O/P) 1,600 VDC (60 s test duration, Functional Insulation)
Isolation Resistance (at 500 VDC) 1,000 MΩ min. (Input to Output)
Isolation Capacitance 1,500 pF max. (Input to Output, at 100 kHz, 1 V)
Operating Ambient Temperature Range -40 °C to +85 °C (-40 °F to +185 °F); up to +87 °C with TEN-HS1, +90 °C with TEN-HS8, +92 °C with TEN-HS9, +95 °C with TEN-HS10; Max. Case Temp: +105 °C (+221 °F)
High-Temperature Derating Rate Case-to-Ambient Thermal Impedance: 10.8 K/W typ. (standalone) / 10.3 K/W typ. (with heatsink TEN-HS1)
Altitude Derating 5,000 m (16,404 ft) max. operating altitude
Storage Temperature Range -55 °C to +125 °C (-67 °F to +257 °F)
Operating Relative Humidity 95% RH max. (non-condensing, Pollution Degree PD 2)
Temperature Coefficient ±0.02 %/K max.
Vibration Resistance EN 61373 & MIL-STD-810F (Vibration, Mechanical Shock & Thermal Shock certified)
Flammability Rating EN 45545-2 (Railway Fire & Smoke Protection) & UL 94 V-0 (Baseplate & Silicone Potting)
Safety Approvals (UL / North America) UL 62368-1, UL 60950-1
Safety Approvals (IEC / EN / TÜV) EN 50155 (Railway), IEC 62368-1, EN 62368-1 (Output classified ES1 / PS3), IEC 60950-1, EN 60950-1
EMC Conducted & Radiated Emissions EN 50121-3-2 (Rolling Stock), EN 55032 Class A & Class B (Conducted & Radiated with external filter)
EMC Immunity Standards EN 50121-3-2, EN 61000-4-2 (ESD ±8 kV Air / ±6 kV Contact, Criteria A), EN 61000-4-3 (RF Field 20 V/m, Criteria A), EN 61000-4-4 (EFT ±2 kV, Criteria A), EN 61000-4-5 (Surge ±2 kV with 220 µF 100 V KY || SMDJ120A, Criteria A), EN 61000-4-6 (Conducted RF 10 Vrms, Criteria A), EN 61000-4-8 (Magnetic Field 100 A/m cont. / 1000 A/m 1 s, Criteria A)
MTBF (MIL-HDBK-217F) 900,000 hours (Ground Benign at +25 °C)
Environmental Compliance RoHS Compliant (with exemptions 7(a), 7(c)-I), REACH SVHC & Annex XVII Compliant (SCIP: 00c7ae30-3d8c-4682-88e1-0d2e69ce3142)

Industrial Applications & Compatible Systems

Engineered for harsh transportation and industrial control environments, the TRACO Power TEN 40-4811WIR provides high-density, transient-immune 5 VDC power conversion across critical subsystems:

  • Railway & Rolling Stock Electronics: Powers onboard train control and monitoring systems (TCMS), passenger information displays, cab signaling consoles, and wayside transceivers requiring strict EN 50155, EN 50121-3-2, and EN 45545-2 compliance.
  • 48 VDC Telecom & Wireless Base Stations: Steps down 48 VDC nominal (18–75 VDC) telecom battery buses to a tightly regulated 5 VDC / 8 A rail for cellular backhaul routers, optical transceivers, and remote radio heads.
  • Battery-Operated Mobile Machinery & AGVs: Ideal for autonomous guided vehicles, heavy construction equipment, and mobile robotics where the 10 mA typical no-load current and remote On/Off pin (3 mA idle) prevent battery drain during standby.
  • Industrial Automation & Test Instrumentation: Supplies low-noise (75 mVp-p typical), galvanically isolated 1,600 VDC logic power to FPGA/DSP boards, PLC I/O backplanes, and precision data acquisition equipment.

Installation, Thermal Management & MRO Guidelines

To ensure long-term operational reliability and full regulatory compliance during PCB layout and system integration, observe these critical engineering guidelines:

  • External Input Fuse & Surge Protection Network: Install a 4,000 mA (4 A) slow-blow fuse in series with the +Vin line, and connect a parallel 220 µF / 100 V Nippon Chemi-Con KY capacitor with an SMDJ120A TVS diode across the input terminals to meet EN 61000-4-4/5 (±2 kV) immunity criteria.
  • PCB Trace Routing & Wave Soldering Limits: Avoid routing exposed PCB signal traces directly underneath the converter body, and restrict lead-free wave soldering profiles to a maximum of 265 °C for 10 seconds on the Ø 1.0 mm matte-tin pins.
  • Thermal Management & Output Voltage Trimming: Maintain at least 20 LFM natural convection and keep the copper case below +105 °C (attach clip-on heatsinks TEN-HS1, TEN-HS8, TEN-HS9, or TEN-HS10 for elevated ambient operation up to +95 °C); when trimming Vout up to +10% via Pin 6, ensure total load power never exceeds 40 W.