Description
XP Power PBL500PS24C is a high-density 500 W enclosed AC-DC switching power supply from the medical-grade PBL500 series, where the “PS24” nomenclature designates a single 24 VDC main output rail and the “C” suffix specifies the factory-enclosed chassis configuration with an integral temperature-controlled cooling fan. Engineered for both Class I and Class II medical equipment requiring Body Floating (BF) applied-part insulation, the unit accepts a universal 80–264 VAC (47–63 Hz) input and delivers up to 20.84 A continuous output current (500 W) alongside an independent 5.0 VDC / 2.0 A standby rail (V2). Its active power factor corrected (PFC) front end operates at a fixed 65 kHz switching frequency paired with a variable 90–300 kHz main converter stage to achieve 90% typical efficiency at 230 VAC, ±2% combined line and load regulation, fast <500 µs transient recovery, and low output ripple of 240 mV pk-pk maximum.
Constructed in a compact covered metal housing measuring 180.3 × 101.6 × 67.0 mm (7.10 × 4.00 × 2.64 in) and weighing 1.14 kg (2.52 lbs), the supply incorporates an intelligent internal cooling fan regulated by transformer T1 thermal sensing (remaining off below ~30 °C and scaling to full speed at ~60 °C). Field wiring is streamlined via a Dinkle DT-35C-B01W-03 M3 screw terminal block (P1) for AC input, heavy-duty M4×0.7 screw terminals (P2) for the 24 VDC main output, and an 8-pin Molex 87833-08 header (P3) providing Remote Sense (0.5 V drop compensation), TTL Inhibit, Power OK (POK), and 5 VDC standby power. Comprehensive protection encompasses latching overvoltage (112–140%), trip-and-restart overcurrent (105–140%), latching overtemperature shutdown, and dual internal line/neutral fusing. Certified to IEC/ES/EN 60601-1 and CSA C22.2 No. 60601-1 up to 5000 m altitude, it provides 4000 VAC (2×MOPP) input-to-output and input-to-ground isolation, 1500 VAC (1×MOPP) output-to-ground isolation, ultra-low 50 µA typical patient leakage current, and EN 55011 / EN 55032 Class B EMI compliance.
Key Features
- 500W Regulated 24VDC Output & 5V Standby: Delivers 24 VDC at up to 20.84 A continuous load (500 W) with ±2% total regulation, 240 mV pk-pk maximum ripple, and an auxiliary 5.0 VDC / 2.0 A standby rail.
- 2xMOPP & BF-Rated Medical Isolation: Certified to IEC/EN/ES 60601-1 with 4000 VAC input-to-output (2xMOPP), 4000 VAC input-to-ground (2xMOPP), and 1500 VAC output-to-ground (1xMOPP) isolation for Body Floating (BF) medical systems.
- Ultra-Low Patient Leakage Current: Restricts patient leakage current to 50 µA typical and 80 µA maximum at 264 VAC / 63 Hz, supporting Class II medical installations and sensitive patient-connected diagnostic equipment.
- Acoustic-Optimized Thermal Fan Control: Features an integral top-mounted fan governed by internal transformer T1 temperature monitoring, remaining stationary below 30 °C and ramping smoothly to full airflow at 60 °C.
- Remote Sense, Inhibit & Power OK Telemetry: Dedicated 8-pin Molex signal header (P3) provides 0.5 V remote sense line-drop compensation, TTL-high remote inhibit (reducing no-load power to 1 W), and Power OK monitoring.
- Class B EMI & High Surge Immunity: Meets EN 55011 and EN 55032 Class B conducted and radiated emissions without external filtering, alongside EN 61000-3-2 Class A harmonics and Level 4 ESD immunity.
- Wide-Altitude & Extended Thermal Operation: Operates across 0 °C to +70 °C ambient (full 500 W load up to +40 °C, linear derating to 50% at +60 °C) at altitudes up to 5000 meters.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | PBL500PS24C |
| Compatible Equipment / Series | BF-Rated Medical Devices, Class I & Class II Medical Systems, Surgical & Diagnostic Instrumentation |
| Product Series | PBL500 Series |
| Product Category | Converter Heatsinks |
| Component Type | Enclosed Fan-Cooled Medical AC-DC Switching Power Supply |
| Circuit Topology | Switched-Mode Power Supply (SMPS) with Active PFC, Variable-Frequency Main Converter & Standby Converter |
| Nominal Output Voltage | 24 VDC (Main Output V1) |
| Rated Output Current | 20.84 A (at 24 VDC with Integral Fan Cooling) |
| Rated Output Power | 500 W Continuous |
| Number of Outputs | 2 Outputs (Main Output V1 + Standby Output V2; V3 Fan Output Omitted on Covered C Version) |
| Ch1 Output Voltage & Current | V1 Main Output: 24 VDC at 20.84 A (500 W) |
| Ch2 Output Voltage & Current | V2 Standby Supply: 5.0 VDC at 2.0 A (10 W) |
| Output Ripple & Noise (Max.) | 240 mV pk-pk (1% pk-pk max, 20 MHz bandwidth with 10 µF tantalum and 0.1 µF ceramic parallel capacitors) |
| Output Voltage Tolerance | ±2% (Combined Line and Load Regulation; 0.1% minimum load required) |
| Transient Recovery Time & Deviation | 4% max deviation, recovery within 1% in <500 µs (for a 25% step load change) |
| Hold-Up Time (at 115 VAC) | 20 ms typical (at 110 VAC and 500 W full load) |
| AC Input Voltage Range | 80 VAC to 264 VAC |
| Input Frequency Range | 47 Hz to 63 Hz |
| Efficiency (at 230 VAC) | 90% typical (at 230 VAC, 100% full load) |
| AC Input Current (at 115 VAC) | 5.2 A rms typical (at 115 VAC, 60 Hz, full load) |
| AC Input Current (at 230 VAC) | 2.6 A rms typical (at 230 VAC, 50 Hz, full load) |
| Inrush Current (Cold Start at 115 VAC) | 30 A maximum (at 115 VAC, 25 °C cold start) |
| Inrush Current (Cold Start at 230 VAC) | 60 A maximum (at 230 VAC, 25 °C cold start) |
| Power Factor Correction (PFC) | Active PFC Stage (EN 61000-3-2 Class A Compliant) |
| No-Load Power Consumption | 1 W typical (when Remote Inhibit is active) |
| Switching Frequency | PFC Converter: 55–75 kHz (65 kHz typ. fixed); Main Converter: 90–300 kHz (variable); Standby Converter: 80–120 kHz (variable) |
| Mounting Style | Chassis Mount (8× M3×0.5 or #6-32 threaded mounting inserts, 4 mm max screw penetration) |
| Cooling Method | Forced Air via Integral Temperature-Controlled Top Fan (Monitored via Transformer T1: Off <30 °C, Full Speed at 60 °C) |
| Package / Footprint Standard | Covered U-Channel Enclosure with Top-Mounted Fan (Power Density: 0.684 W/cm³ / 11.2 W/in³) |
| Overall Width (W) | 101.6 mm (4.00 in) body width; 107.0 mm (4.21 in) overall across mounting tabs |
| Overall Height (H) | 67.0 mm (2.64 in) including integral top fan |
| Overall Depth (D) | 180.3 mm (7.10 in) nominal; 180.0 mm (7.09 in) drawing length |
| Dimensional Tolerance | ±0.5 mm (±0.02 in) maximum |
| Mounting Hole Pitch | Bottom Pattern: 150.0 × 60.0 mm (5.91 × 2.36 in); Side Pattern: 166.0 × 20.8 mm (6.54 × 0.82 in) |
| Net Weight | 1.14 kg (2.52 lbs) approximate |
| Termination / Connector Style | Input P1: Dinkle DT-35C-B01W-03 M3 Screw Terminal; Output P2: M4×0.7 Screw Terminals; Signals P3: Molex 87833-08 8-Pin Header (mates with Molex 51110-0850) |
| Input Terminal Pinout | Input Connector P1: Pin 1 = Line (L), Pin 2 = Neutral (N) (Dual internal fuses fitted in Line and Neutral) |
| Output & Signal Terminal Pinout | Output P2: Pin 1 = +V1 Main Output (24 VDC), Pin 2 = -V1 Common Return; Signal Header P3: Pin 1 & 8 = Common Return, Pin 2 = +V1 Sense, Pin 3 = -V1 Sense, Pin 4 = Power OK / AC OK, Pin 5 = Inhibit, Pin 6 & 7 = +V2 (5 VDC Standby) |
| Control & Monitoring Signals | Remote Sense (compensates up to 0.5 V total drop), Remote Inhibit (apply TTL High to disable output), Power OK / AC OK (TTL High normal, 100–1000 ms turn-on delay, 1 ms pre-warning on AC loss) |
| Overload Protection (OLP) Threshold | 105% to 140% of rated output current |
| Overload Protection (OLP) Mode | Trip and Restart (Hiccup / Auto-Recovery Mode) |
| Overvoltage Protection (OVP) Threshold | 112% to 140% of nominal V1 output voltage |
| Overvoltage Protection (OVP) Mode | Latching Shutdown (Requires AC Input Recycle to Reset) |
| Overtemperature Protection (OTP) Mode | Latching Thermal Shutdown |
| Short Circuit Protection (SCP) | Continuous Trip and Restart (Auto-Recovery) with Dual Internal Input Fuses (Line & Neutral) |
| Withstand Isolation Voltage (I/P to O/P) | 4000 VAC (2 × MOPP) |
| Withstand Isolation Voltage (I/P to FG / Case) | 4000 VAC (2 × MOPP) |
| Withstand Isolation Voltage (O/P to FG / Case) | 1500 VAC (1 × MOPP) |
| Earth Leakage Current | 50 µA typical, 80 µA maximum Patient Leakage Current (at 264 VAC, 63 Hz) |
| Medical Isolation Rating | 2 × MOPP (Input to Output & Input to Ground), 1 × MOPP (Output to Ground), Medical Body Floating (BF) Rated, Class II Applications |
| Operating Ambient Temperature Range | 0 °C to +70 °C (+32 °F to +158 °F); Safety Approved up to +40 °C (+104 °F) |
| Full-Load Operating Temperature Limit | +40 °C (+104 °F) at 100% Load (500 W) |
| High-Temperature Derating Rate | Derate linearly at 2.5% per °C (12.5 W/°C) from 100% load (500 W) at +40 °C to 50% load (250 W) at +60 °C |
| Low-Line Input Derating | Derate output power to 90% (450 W) at 85 VAC and to 80% (400 W) at 80 VAC |
| Altitude Derating | Up to 5000 m (16,404 ft) Maximum Operating Altitude |
| Storage Temperature Range | -10 °C to +85 °C (+14 °F to +185 °F) |
| Operating Relative Humidity | 5% to 95% RH (Non-Condensing) |
| Temperature Coefficient | ±0.04% / °C |
| Safety Approvals (UL / North America) | ANSI/AAMI ES60601-1, CSA C22.2 No. 60601-1 (Medical) |
| Safety Approvals (IEC / EN / TÜV) | IEC 60601-1, EN 60601-1, CB Scheme Certified (Medical) |
| Safety Approvals (Regional / Global) | CE Marked, UKCA Marked |
| EMC Conducted & Radiated Emissions | EN 55032 Class B, EN 55011 Class B (Conducted and Radiated) |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker) |
| EMC Immunity Standards | EN 61000-4-2 (ESD Level 4: ±8 kV contact, ±15 kV air, Criteria A), EN 61000-4-3 (Radiated: 10 V/m, Criteria A), EN 61000-4-4 (EFT/Burst: ±2 kV, Criteria A), EN 61000-4-5 (Surge Level 3: ±2 kV L-N, Criteria A), EN 61000-4-6 (Conducted RF: 10 Vrms, Criteria A), EN 61000-4-8 (Magnetic Field: 30 A/m, Criteria A), Voltage Dips & Interruptions (100 VAC & 240 VAC / 50 Hz per datasheet table) |
| MTBF (MIL-HDBK-217F) | 100,000 Hours minimum (Full load at +25 °C, Ground Benign) |
| Environmental Compliance | RoHS & CE / UKCA Directive Compliant |
Industrial Applications & Compatible Systems
The XP Power PBL500PS24C is purpose-built for medical electronics and high-reliability industrial systems requiring Body Floating (BF) patient protection and Class II insulation:
- Patient-Connected Medical & Surgical Equipment: Powers electrosurgical generators, patient monitors, ultrasound carts, and infusion pumps requiring 2×MOPP isolation, BF applied-part compliance, and <80 µA patient leakage current.
- Clinical & Molecular Diagnostic Analyzers: Provides low-noise 24 VDC main power (240 mV pk-pk max) and a continuous 5 VDC / 2 A standby rail for automated hematology analyzers, PCR thermal cyclers, and clinical laboratory robotics.
- Home Healthcare & Point-of-Care Devices: Supports Class II (unearthed) home respiratory therapy machines, dialysis systems, and mobile imaging carts operating on residential mains (EN 55011 Class B emissions) at altitudes up to 5000 meters.
- Precision Analytical & Semiconductor Instrumentation: Drives optical inspection platforms, laser etching controllers, and precision laboratory automation utilizing remote sense compensation and TTL inhibit control.
Installation, Thermal Management & MRO Guidelines
Follow these engineering and MRO guidelines when integrating the PBL500PS24C into host enclosures:
- Chassis Mounting & Screw Penetration Limits: Secure the enclosure using either the M3×0.5 or #6-32 threaded mounting inserts (8 places), ensuring fixing screws penetrate no more than 4.0 mm (0.16 in) from the outer surface of the chassis to maintain internal creepage and clearance barriers.
- Thermal Derating & Low-Line Management: Provide unobstructed intake clearance above the top-mounted cooling fan; derate continuous load linearly from 500 W at +40 °C to 250 W at +60 °C, and apply low-line derating below 90 VAC (450 W at 85 VAC; 400 W at 80 VAC).
- High-Current Wiring & Remote Sense Connection: Terminate the 20.84 A main 24 VDC output onto the M4×0.7 screw terminals (P2) using appropriately sized lugs, and wire Pin 2 (+V1 Sense) and Pin 3 (-V1 Sense) on the Molex 87833-08 header (P3) directly to the load to compensate for up to 0.5 V of cable drop.