CUS30M-18 TDK-Lambda 30.6W 18VDC Medical Open Frame PSU

$29.00

TDK-Lambda CUS30M-18 (CUS30M18) 30.6W 18VDC 1.7A medical open-frame AC-DC power supply, 85-264VAC input, 88% efficiency, 2xMOPP 4kVAC isolation.

SKU: CUS30M-18 Category: Brand:

Description

TDK-Lambda CUS30M-18 (also known as CUS30M18) is a compact, 2″ × 3″ open-frame single-output AC-DC power supply from the CUS30M & CUS60M medical and ITE series, where the base part number designates the 30W convection-cooled platform, the -18 suffix specifies an 18 VDC nominal output, and the blank option suffix indicates an open-frame chassis fitted with industry-standard JST VH series connectors. Engineered for universal 85 to 264 VAC (47–63 Hz) operation without requiring external EMI filtering, this regulated switching converter delivers 1.7 A continuous output current (30.6 W rated power) with 87% typical efficiency at 115 VAC and 88% at 230 VAC, while maintaining <0.3 W no-load power draw at 265 VAC. Tight regulation is maintained at 72 mV line regulation, 144 mV load regulation, and 150 mV peak-to-peak ripple and noise across zero-to-full load conditions without any minimum load requirement.

Built for demanding clinical and industrial environments, the CUS30M-18 features reinforced 4 kVAC input-to-output isolation (2×MOPP), 2 kVAC input-to-ground (1×MOPP), and 1.5 kVAC output-to-ground (1×MOPP) suitable for Type B and BF patient-connected equipment in Class I or Class II (double-insulated) installations. Integrated protection circuits safeguard downstream electronics via >105% overcurrent limiting (UL/IEC Class 2 Limited Power Source) and >115% latching overvoltage shutdown requiring an AC input cycle to reset. Housed in a lightweight 62 g (2.19 oz) open-frame assembly measuring 76.2 × 50.8 × 24.2 mm (3.0 × 2.0 × 0.95 in), the module supports -30 °C cold start-up, full-load convection operation up to +45 °C (with linear derating to 50% load at +70 °C), and carries global IEC/EN/UL/ES/CSA 60601-1 3rd Edition, IEC 62368-1, EN 60335-1, and EN 60601-1-2:2015 Edition 4 approvals.

Key Features

  • Medical 2×MOPP Reinforced Isolation: Certified to IEC/EN/UL/ES/CSA 60601-1 3rd Edition with 4 kVAC I/P-O/P and 1.5 kVAC O/P-FG isolation for Type B and BF medical equipment.
  • Ultra-Compact 2″ × 3″ Convection Footprint: Measures 76.2 × 50.8 × 24.2 mm (3.0 × 2.0 × 0.95 in) and weighs just 62 g (2.19 oz), operating fanlessly for silent clinical environments.
  • High Efficiency & Ultra-Low Standby Draw: Achieves 87% efficiency at 115 VAC and 88% at 230 VAC (87% average active efficiency) with <0.3 W no-load consumption at 265 VAC.
  • Class I & Class II Built-In Class B EMI: Meets EN 55011-B, EN 55032-B, and FCC Class B conducted and radiated limits in grounded or double-insulated setups without external filters.
  • Comprehensive Immunity & SEMI F47 Compliance: Tested to EN 60601-1-2:2015 Edition 4, Level 4 contact ESD (±8 kV), Level 4 common-mode surge, and SEMI F47 voltage dips above 200 VAC.
  • Class 2 LPS & Latching Overvoltage Protection: Provides >105% overcurrent protection compliant with Class 2 Limited Power Source standards alongside >115% latching OVP shutdown.
  • Wide Thermal & Altitude Operating Envelope: Supports -30 °C cold start-up, -20 °C to +70 °C ambient operation (full load to +45 °C), and deployment up to 5,000 m altitude.

Technical Specifications

Manufacturer TDK-Lambda
Manufacturer Part Number (MPN) CUS30M-18
Alternate Part Number CUS30M18
Product Series CUS30M & CUS60M Series
Product Category Medical Open Frame
Component Type Single-Output Medical & ITE AC-DC Open-Frame Power Supply
Installation Class Class I or Class II (Double Insulated) Construction
Nominal Output Voltage 18 VDC
Rated Output Current 1.7 A
Current Range 0 to 1.7 A (No Minimum Load Required)
Rated Output Power 30.6 W
Output Ripple & Noise (Max) 150 mVp-p (Increases at light load to meet efficiency standards)
Line Regulation (Max) 72 mV
Load Regulation (Max) 144 mV
Minimum Load Requirement 0 A (No minimum load required)
Temperature Coefficient < 0.02 %/°C
Hold-Up Time (at 115 VAC) 20 ms (Typical)
Hold-Up Time (at 230 VAC) 100 ms (Typical)
Parallel Operation Not Supported
AC Input Voltage Range 85 to 264 VAC (Single-Phase)
Input Frequency Range 47 to 63 Hz
Efficiency (at 115 VAC) 87% (Typical, Full Load)
Efficiency (at 230 VAC) 88% (Typical, Full Load)
Average Active Efficiency (at 115 VAC) 87% (Typical, measured at 25%, 50%, 75%, and 100% load)
Average Active Efficiency (at 230 VAC) 87% (Typical, measured at 25%, 50%, 75%, and 100% load)
AC Input Current (at 110 VAC) 0.6 A
AC Input Current (at 230 VAC) 0.4 A
Inrush Current (Cold Start at 115 VAC) 30 A (Typical)
Inrush Current (Cold Start at 230 VAC) 60 A (Typical)
No-Load Power Consumption < 0.3 W (at 265 VAC)
Overload / Overcurrent Protection (OLP) Threshold > 105% of Rated Current
Overload / Overcurrent Protection (OLP) Mode Class 2 Limited Power Source (LPS) Compliant Current Limiting
Overvoltage Protection (OVP) Threshold > 115% of Nominal Output Voltage (> 20.7 VDC)
Overvoltage Protection (OVP) Mode Latching Shutdown (Cycle AC input to reset)
Withstand Isolation Voltage (I/P to O/P) 4,000 VAC (4 kVAC) for 1 Minute (2×MOPP)
Withstand Isolation Voltage (I/P to FG / Ground) 2,000 VAC (2 kVAC) for 1 Minute (1×MOPP)
Withstand Isolation Voltage (O/P to FG / Ground) 1,500 VAC (1.5 kVAC) for 1 Minute (1×MOPP, Type B & BF Rated)
Isolation Resistance (at 500 VDC) > 100 MΩ (Output to Ground at 25 °C, 70% RH)
Earth Leakage Current < 0.25 mA (250 µA) at 265 VAC, 60 Hz
Patient / Enclosure Touch Current 100 µA at 265 VAC, 60 Hz
Operating Ambient Temperature -20 °C to +70 °C (-4 °F to +158 °F) with -30 °C (-22 °F) Cold Start-Up
Full-Load Operating Temperature Limit +45 °C (+113 °F) for CUS30M-18
High-Temperature Derating Rate Linear derating to 50% load (15.3 W / 0.85 A) from +45 °C to +70 °C (2.0 %/°C)
Low-Line Input Voltage Derating Linear derating to 80% load (24.48 W / 1.36 A) from 115 VAC down to 85 VAC
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating & Storage Humidity 10% to 90% RH (Non-Condensing)
Maximum Operating Altitude 5,000 m (16,404 ft); derate ambient temperature by 5 °C/1,000 m above 3,000 m
Vibration Resistance (Non-Operating) 10 to 500 Hz, 19.6 m/s² (2G) constant sweep 1 min/cycle along X, Y, Z axes for 1 hour
Mechanical Shock Resistance < 196.1 m/s² (< 20G)
MTBF (Telcordia SR-332 Issue 3) 9,960,323 Hours (25 °C ambient, full load, 230 VAC input)
Medical Safety Certifications IEC 60601-1, EN 60601-1, UL/ES 60601-1, CSA C22.2 No. 60601-1 (3rd Edition, 2×MOPP)
ITE & Household Safety Certifications IEC/EN/UL/CSA 62368-1, 60950-1, EN 61558-1, EN 60335-1, Designed to meet IEC 61010-1
Regional Compliance Marks CE Mark, UKCA Mark
Conducted & Radiated EMI Emissions EN 55011 Class B, EN 55032 Class B, FCC Part 15 Class B (Class I & Class II)
Harmonic Current Emissions EN 61000-3-2 Compliant
Medical EMC Immunity Standard EN 60601-1-2:2015 Edition 4 (Class 2 Voltage Dips Criteria B at 100–120 VAC, Criteria A at 200–240 VAC)
ESD Immunity (EN 61000-4-2) Level 3 & Level 4 (Level 4 Contact Discharge Only), Performance Criteria A
Radiated RF Immunity (EN 61000-4-3) Level 3, Performance Criteria A
EFT / Burst Immunity (EN 61000-4-4) Level 3, Performance Criteria A
Surge Immunity (EN 61000-4-5) Level 3 & Level 4 (Level 4 Common Mode Only), Performance Criteria A
Conducted RF Immunity (EN 61000-4-6) Level 3, Performance Criteria A
Power Frequency Magnetic Immunity (EN 61000-4-8) Level 4, Performance Criteria A
Voltage Dips & Short Interruptions (EN 61000-4-11) Class 3 (Criteria B at 100–120 VAC; Criteria A at 200–240 VAC)
Semiconductor Sag Immunity (SEMI F47) Compliant at Input Voltages > 200 VAC
Input Connector (CN1) JST B2P3-VH(LF)(SN) 3-Position Header (Center Pin Removed; Mates with JST VHR-3N Housing)
Output Connector (CN-51) JST B4P-VH(LF)(SN) 4-Position Header (Mates with JST VHR-4N Housing)
Cooling Method Natural Convection Cooled (Fanless)
Form Factor & Mounting Style Open-Frame PCB Assembly (2″ × 3″ Industry-Standard Footprint)
Overall Length (L) 76.2 mm (3.00 in)
Overall Width (W) 50.8 mm (2.00 in)
Overall Height (H) 24.2 mm (0.95 in)
Overall Dimensions (L × W × H) 76.2 × 50.8 × 24.2 mm (3.00 × 2.00 × 0.95 in)
Net Weight 62 g (2.19 oz / 0.137 lbs)
Manufacturer Warranty 3 Years

Industrial Applications & Compatible Systems

TDK-Lambda CUS30M-18 is engineered for space-constrained medical, laboratory, and industrial equipment requiring silent convection cooling and 2×MOPP patient-grade isolation:

  • Diagnostic & Patient-Connected Medical Devices: Infusion pumps, patient monitors, portable ultrasound systems, blood analyzers, and Type B / BF clinical instrumentation requiring 4 kVAC isolation and <100 µA touch current.
  • Home Healthcare & Dental Equipment: CPAP respiratory therapy units, nebulizers, dental chairs, and surgical lighting where EN 60601-1-2 Edition 4 immunity and Class II double-insulated operation are mandatory.
  • Test, Measurement & Laboratory Instruments: Benchtop analytical meters, spectrometers, and IEC 61010-1 compliant diagnostic analyzers sensitive to fan vibration and acoustic noise.
  • Industrial Automation & Semiconductor Tooling: Embedded 18 VDC sensor controllers, human-machine interfaces (HMIs), and SEMI F47-compliant auxiliary control boards.

Installation, Thermal Management & MRO Guidelines

Installation & Engineering Guidelines: When integrating the open-frame CUS30M-18 into an end-product enclosure, maintain adequate primary-to-secondary creepage and clearance distances to preserve 2×MOPP reinforced isolation, particularly in Class II installations without a protective earth connection. Unlike 12 V, 15 V, and 24 V CUS30M variants rated to +50 °C, the CUS30M-18 maintains 100% output (30.6 W) up to +45 °C ambient in free-air convection and must be linearly derated at 2.0 %/°C down to 50% load (15.3 W) at +70 °C, as well as linearly derated to 80% load below 115 VAC down to 85 VAC. Use genuine JST VHR-3N (input CN1) and VHR-4N (output CN-51) crimp housings with appropriate SVH-21T-P1.1 contacts, and size upstream branch protection to withstand the 60 A cold-start inrush peak at 230 VAC.