Description
TDK-Lambda CUS200M-18 (also known as CUS200M18) is a high-efficiency AC-DC medical and ITE open-frame power supply from the CUS200M series, where the -18 suffix designates its 18 VDC nominal main output and the blank suffix denotes the standard industry 3 x 5 inch open-frame PCB configuration. Engineered with an active power factor corrected (PFC) topology achieving up to 94% efficiency at 230 VAC (92% at 115 VAC), it delivers 201.6 W (11.2 A) under silent natural convection cooling and scales up to 252.0 W (14.0 A) with 1.5 m/s forced air. The unit operates across a universal 85 to 265 VAC (47–63 Hz) or 120 to 370 VDC input range while maintaining tight 0.5% line regulation, 1% load regulation, and low output ripple and noise capped at 180 mVpp (1%). In addition to its adjustable 17.6 to 18.9 VDC main rail, the supply integrates an auxiliary 5 V standby output rated at 0.6 A in convection and 1.0 A under forced air, alongside isolated Remote On/Off control and a DC_OK power-good signal.
Constructed on a compact 76.2 x 34.0 x 127.0 mm (3.00 x 1.34 x 5.00 in) footprint weighing 350 g (0.77 lbs), the CUS200M-18 utilizes genuine JST headers including a B3P5-VH (CN1) AC input connector, a B6P-VH (CN51) main DC output connector, and an 8-pin CN61 control header plus an onboard VR51 trim potentiometer and green LED indicator. Comprehensive protection circuits safeguard downstream loads with overcurrent protection (>14.7 A) and latch-style overvoltage protection (19.8–24.3 VDC) requiring AC input cycling to reset. Designed for Class I installations and Type B and BF patient-applied medical equipment, it provides reinforced 4,000 VAC (2xMOPP) input-to-output isolation, 2,000 VAC (1xMOPP) input-to-ground isolation, and 1,500 VAC (1xMOPP) output-to-ground isolation with earth leakage current kept below 300 µA at 265 VAC. The supply operates from -20 °C to +70 °C (-4 °F to +158 °F) with full convection load up to +50 °C (+122 °F) and holds dual medical and ITE certifications to IEC/UL/EN 60601-1, IEC/UL/EN 62368-1, EN 55011/55022 Class B EMI, and IEC 60601-1-2 Ed4 immunity.
Key Features
- Dual Convection and Forced-Air Power Ratings: Delivers 201.6 W (11.2 A) continuously with silent natural convection cooling for noise-sensitive hospital rooms, or up to 252.0 W (14.0 A) with 1.5 m/s forced airflow.
- Reinforced 2xMOPP Medical Isolation Architecture: Certified for Type B and BF medical equipment with 4,000 VAC (2xMOPP) input-to-output, 2,000 VAC (1xMOPP) input-to-ground, and 1,500 VAC (1xMOPP) output-to-ground dielectric withstand.
- Up to 94% Conversion Efficiency & Active PFC: Achieves 92% efficiency at 115 VAC and 94% at 230 VAC with active power factor correction (0.99 / 0.95) and <0.5 W standby no-load power draw.
- Integrated 5V Standby, DC_OK & Remote Inhibit: Built-in CN61 signal interface provides a 5 VDC auxiliary output (0.6 A convection / 1.0 A forced air), DC Good status monitoring, and isolated Remote On/Off shutdown.
- Class B EMI & 4th Edition Medical Immunity: Meets EN 55011-B, EN 55022-B, and FCC Class B conducted and radiated emissions alongside IEC 60601-1-2 Ed4 and SEMI F47 line dip immunity standards.
- Compact 3 x 5 Inch Open-Frame Footprint: Measures 76.2 x 34.0 x 127.0 mm (3.00 x 1.34 x 5.00 in) with low <300 µA earth leakage current and wide -20 °C to +70 °C ambient operation.
- Precision Output Trim & Hardware Protections: Onboard VR51 potentiometer adjusts the 18 VDC rail from 17.6 to 18.9 VDC, backed by >14.7 A overcurrent protection and 19.8–24.3 V latching overvoltage protection.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | CUS200M-18 |
| Alternate Part Number | CUS200M18 |
| Product Series | CUS200M Series |
| Product Category | Medical Open Frame |
| Component Type | AC-DC Medical & ITE Open Frame Power Supply |
| Circuit Topology | Switched-Mode Power Supply (SMPS) with Active PFC |
| Nominal Output Voltage | 18 VDC (Main Output) / 5 VDC (Standby Output) |
| Output Voltage Adjustment Range | 17.6 to 18.9 VDC (via onboard potentiometer VR51) |
| Rated Output Current | 11.2 A (Convection Cooling) / 14.0 A (Forced Air Cooling at 1.5 m/s) |
| Rated Output Power | 201.6 W (Convection Cooling) / 252.0 W (Forced Air Cooling at 1.5 m/s) |
| Number of Outputs | 1 Main Output + 1 Auxiliary 5 V Standby Output |
| Ch1 Output Voltage & Current | 18 VDC at 11.2 A (Convection) / 14.0 A (Forced Air) |
| Ch2 Output Voltage & Current | 5 VDC Standby (5Vsb) at 0.6 A (Convection) / 1.0 A (Forced Air) |
| Output Ripple & Noise (Max.) | 180 mVpp (180 mV or 1% of nominal output, whichever is greater) |
| Line Regulation | 0.5% of nominal output |
| Load Regulation | 1.0% of nominal output (No minimum load required) |
| Hold-Up Time | 16 ms typ. (at 200 W output) / 12 ms typ. (at 250 W output, 115 / 230 VAC) |
| AC Input Voltage Range | 85 to 265 VAC operating (100 to 240 VAC nominal; safety certified for 90 to 264 VAC) |
| DC Input Voltage Range | 120 to 370 VDC (Safety certified for AC input only) |
| Nominal Input Voltage | 100 to 240 VAC |
| Input Frequency Range | 47 to 63 Hz (Safety certified for 50 to 60 Hz) |
| Efficiency (at 115 VAC) | 92% (at 200 W output) |
| Efficiency (at 230 VAC) | 94% (at 200 W output) |
| AC Input Current (at 115 VAC) | 2.2 A (at 200 W output) / 3.0 A (at 250 W output) |
| AC Input Current (at 230 VAC) | 1.1 A (at 200 W output) / 1.5 A (at 250 W output) |
| Inrush Current (Cold Start at 115 VAC) | 35 A typ. |
| Inrush Current (Cold Start at 230 VAC) | 70 A typ. |
| Power Factor (PF at 115 VAC) | 0.99 |
| Power Factor (PF at 230 VAC) | 0.95 |
| Power Factor Correction (PFC) | Active PFC (Meets EN 61000-3-2 Class A) |
| No-Load Power Consumption | < 0.5 W at 230 VAC (with Remote On/Off activated and no load on 5Vsb) |
| Mounting Style | Chassis / PCB Standoff Mount (Open Frame, Class I Installation) |
| Cooling Method | Natural Convection (201.6 W) or Forced Air Cooling at 1.5 m/s across terminals (252.0 W) |
| Package / Footprint Standard | 3 x 5 Inch Industry Standard Open Frame |
| Overall Width (W) | 76.2 mm (3.00 in) |
| Overall Height (H) | 34.0 mm (1.34 in) |
| Overall Depth (D) | 127.0 mm (5.00 in) |
| Dimensional Tolerance | ±1.0 mm on outer L x W dimensions; ±0.5 mm on mounting hole pitch |
| Mounting Hole Pitch | 115.6 x 64.8 mm (4.55 x 2.55 in) |
| Net Weight | 350 g (0.77 lbs / 12.35 oz) |
| Termination / Connector Style | JST VH Series PCB Headers (CN1 Input, CN51 Output) & Signal Header (CN61) |
| Input Terminal Pinout | CN1 (JST B3P5-VH(LF)(SN), mates with VHR-5N housing): Live (L), Neutral (N), Earth Ground |
| Output & Signal Terminal Pinout | CN51 (JST B6P-VH(LF)(SN), mates with VHR-6N): Main DC Output (+V / -V); CN61 (8-Pin Signal Header): Pin 1 STBY+ (5V+), Pin 2 STBY- (5V-), Pin 3-5 NC, Pin 6 DC_OK, Pin 7 R+ (Remote On/Off +), Pin 8 R- (Remote On/Off -) |
| Control & Monitoring Signals | 5V Standby Output, DC_OK Signal, Remote On/Off (Apply voltage to isolated R+/R- terminals to shut unit down); Remote Sense & Parallel Operation: Not supported |
| Status Indicator | Green Output Indicator LED on PCB (marked none on external chassis specification) |
| Overload Protection (OLP) Threshold | > 14.7 A |
| Overvoltage Protection (OVP) Threshold | 19.8 to 24.3 VDC (110% to 135% of nominal output) |
| Overvoltage Protection (OVP) Mode | Latching shutdown (Cycle AC input power to reset) |
| Withstand Isolation Voltage (I/P to O/P) | 4,000 VAC for 1 minute (2xMOPP) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2,000 VAC for 1 minute (1xMOPP) |
| Withstand Isolation Voltage (O/P to FG / Case) | 1,500 VAC for 1 minute (1xMOPP) |
| Isolation Resistance (at 500 VDC) | > 100 MΩ at 25 °C (77 °F) and 70% RH |
| Earth Leakage Current | < 300 µA at 265 VAC, 60 Hz |
| Medical Isolation Rating | 2xMOPP (Input to Output), 1xMOPP (Input to Ground & Output to Ground); Suitable for Type B and BF rated medical equipment |
| Operating Ambient Temperature Range | -20 °C to +70 °C (-4 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) for Convection Mounting A, B, E; +40 °C (+104 °F) for Convection Mounting C, D and Forced Air Cooling |
| High-Temperature Derating Rate | Convection (Mounting A, B): Derate linearly 2.5%/°C from 100% load at +50 °C to 50% load at +70 °C; Convection (Mounting C, D): Derate from 100% at +40 °C to 80% at +50 °C and 40% at +70 °C; Forced Air: Derate from 100% at +40 °C to 50% at +60 °C |
| Low-Line Input Derating | Derate linearly from 100% load at 115 VAC to 80% load at 85 VAC input |
| Altitude Derating | Up to 5,000 m (16,404 ft) for IEC 62368-1; Up to 4,000 m (13,123 ft) for IEC 60601-1 |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 10% to 95% RH (non-condensing) |
| Storage Relative Humidity | 10% to 95% RH (non-condensing) |
| Temperature Coefficient | < 0.02% / °C |
| Vibration Resistance | 10 to 55 Hz at 19.6 m/s² (2G) constant sweep 1 min along X, Y, Z axes for 1 hour (non-operating); Shock: < 196.1 m/s² (20G) |
| Safety Approvals (UL / North America) | UL/CSA/ES 60601-1, UL/CSA 62368-1, UL 60950-1 |
| Safety Approvals (IEC / EN / TÜV) | IEC/EN 60601-1, IEC/EN 62368-1, EN 60950-1 |
| Safety Approvals (Regional / Global) | CE Mark, UKCA Mark (3-Year Manufacturer Warranty) |
| EMC Conducted & Radiated Emissions | EN 55011 Class B, EN 55022 Class B, FCC Class B |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A |
| EMC Immunity Standards | IEC 60601-1-2 Ed4, EN 61000-4-2 (ESD Level 2 & 3, Criteria A), EN 61000-4-3 (Radiated Level 3, Criteria A), EN 61000-4-4 (EFT Level 3, Criteria A), EN 61000-4-5 (Surge Level 3 & 4, Criteria A), EN 61000-4-6 (Conducted Level 3, Criteria A), EN 61000-4-8 (Magnetic Field Level 4, Criteria A), EN 61000-4-11 (Voltage Dips & Short Interruptions Class 3, Criteria B), SEMI F47 Line Dip (at >200 VAC) |
| MTBF (Telcordia SR-332 / Bellcore) | 126,383 Hours (per RCR-9102B; Telcordia calculations yield significantly higher values) |
| Environmental Compliance | RoHS Compliant, Lead-Free (LF) JST Connectors |
Industrial Applications & Compatible Systems
The TDK-Lambda CUS200M-18 is engineered for medical, laboratory, and low-noise industrial systems requiring a compact 18 VDC power source with reinforced patient isolation:
- Hospital & Patient-Care Medical Devices: Certified to IEC/EN/UL 60601-1 with 2xMOPP input-to-output isolation, 1xMOPP to ground, and <300 µA leakage current for Type B and BF patient-contact diagnostic monitors, infusion pumps, and surgical support carts.
- Dental Chairs & Clinical Imaging Equipment: Operates silently at 201.6 W (11.2 A) via natural convection cooling without fan noise, making it ideal for chairside dental treatment units, optical diagnostics, and point-of-care clinical analyzers.
- Broadcast & Professional Audio Consoles: Fanless convection capability coupled with Class B conducted and radiated EMI (EN 55011-B / EN 55022-B) eliminates acoustic hum and RF interference in studio mixing consoles and broadcast transmitters.
- Automated Test & Semiconductor Equipment: Complies with IEC/UL 62368-1 and SEMI F47 line dip immunity (above 200 VAC), providing a stable 18 VDC bus with 5 V standby and DC_OK telemetry for industrial instrumentation.
Installation, Thermal Management & MRO Guidelines
Follow these engineering guidelines to ensure reliable thermal, electrical, and safety performance during integration:
- Mounting Orientation & Thermal Derating: Mount in standard horizontal (Mounting A) or vertical (Mounting B) orientation to sustain 100% convection load (201.6 W) up to +50 °C (+122 °F), derating linearly to 50% load at +70 °C; to extract the full 252.0 W (14.0 A) rating, supply at least 1.5 m/s forced airflow across the terminals.
- Low-Line AC Input & Breaker Sizing: Account for linear input voltage derating down to 80% load between 115 VAC and 85 VAC, and size upstream AC overcurrent protection to withstand the cold-start inrush surge of 35 A at 115 VAC and 70 A at 230 VAC.
- JST Mating Harness & Class I Earthing: Mate input header CN1 (B3P5-VH) with a JST VHR-5N housing and output header CN51 (B6P-VH) with a VHR-6N housing, ensuring PCB lead protrusions beneath the board remain under 3 mm and the unit is bonded to protective earth for Class I EMC and safety compliance.