Description
XP Power MFA350PS12 is an ultra-compact, 361 W U-channel industrial AC-DC power supply belonging to the high-density MFA350 Series, where the base MPN denotes a 12 VDC main output fitted with standard AMP/TE input/output connectors (optional suffixes -S, -TF, and -EF designate screw terminals, top fan, or end fan covers). Engineered around a 62 kHz active PFC front-end and a 157 kHz main switching converter, it delivers 12.0 VDC at up to 29.0 A alongside an auxiliary 12 V / 1 A fan supply and an always-on 5 V / 0.3 A standby rail across a universal 85 to 264 VAC input. Reaching 86% typical full-load efficiency (peaking up to 88% at 230 VAC) and a power density of 11.1 W/in³, the main output maintains ±0.5% line regulation, ±1% load regulation, and low 80 mV pk-pk ripple and noise.
Housed in a low-profile 81.3 × 172.7 × 38.1 mm (3.2 × 6.8 × 1.5 in) open U-channel chassis weighing 612 g (1.35 lbs), the unit integrates a comprehensive J3 logic control interface featuring open-collector AC OK and DC OK status signals, jumper-selectable Remote On/Off, 0.5 V Remote Sense compensation, and single-wire active current sharing for up to three parallel units. Built-in protection circuits guard against continuous short circuits, 110% to 140% auto-recovery overload, 115% to 140% latched overvoltage, and +75 °C PCB overtemperature conditions, backed by 3000 VAC input-to-output reinforced galvanic isolation. Qualified for operation from -10 °C to +70 °C (with 13 CFM forced-air cooling and linear derating above +50 °C), it complies with EN 55032 Class B conducted emissions and carries UL, CSA, TÜV, CB, and CE approvals to IEC/EN/UL 62368-1.
Key Features
- High-Density Triple-Rail Output Architecture: Delivers 361 W total continuous power across a 12.0 VDC / 29.0 A primary rail, a 12 V / 1 A fan output, and a 5 V / 0.3 A standby supply.
- Ultra-Compact 1U U-Channel Footprint: Measures just 81.3 × 172.7 × 38.1 mm (3.2 × 6.8 × 1.5 in) to achieve an industry-leading 11.1 W/in³ power density in tight OEM equipment enclosures.
- Active Current Sharing & Remote Sense: Supports N+1 redundancy or capacity scaling up to three parallel supplies within 10% load balance while compensating up to 0.5 V total cable drop.
- Comprehensive Logic Control & Monitoring Signals: Integrates open-collector AC OK (providing ≥5 ms power-fail warning) and DC OK telemetry alongside jumper-configurable Remote On/Off inhibit/enable control via connector J3.
- Universal AC Input with Active PFC: Operates across 85 to 264 VAC (47–63 Hz) with >0.9 power factor meeting EN 61000-3-2 Class A and Class C (≥20% load) harmonic limits.
- Low Ripple & Fast Transient Recovery: Limits V1 output ripple to 80 mV pk-pk (20 MHz bandwidth) and recovers within 1% in under 500 µs following a 50%–75%–50% dynamic load step.
- Full Protection Suite & 3000 VAC Isolation: Incorporates auto-reset overload, latched overvoltage, continuous short-circuit, and +75 °C thermal shutdown alongside 3000 VAC input-to-output isolation and EN 55032 Class B emissions.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | MFA350PS12 |
| Product Series | MFA350 Series |
| Product Category | Chassis Power Supplies |
| Component Type | U-Channel AC-DC Switching Power Supply |
| Circuit Topology | Active PFC + High-Frequency Switching Converter |
| Nominal Output Voltage | 12.0 VDC (V1 Main); 12 VDC (V2 Fan); 5 VDC (V3 Standby) |
| Output Voltage Adjustment Range | ±10% (10.8 to 13.2 VDC on V1) |
| Rated Output Current | 29.0 A (V1); 1.0 A (V2 Fan); 0.3 A (V3 Standby) |
| Output Current Range | 0 to 29.0 A (no minimum load required) |
| Rated Output Power | 361 W (with 13 CFM forced airflow) |
| Number of Outputs | 3 Outputs (Main V1 + Auxiliary Fan V2 + Always-On Standby V3) |
| Ch1 Output Voltage & Current | 12.0 VDC @ 29.0 A |
| Ch2 Output Voltage & Current | 12.0 VDC @ 1.0 A (Fan Output; unavailable on -TF/-EF variants) |
| Ch3 Output Voltage & Current | 5.0 VDC @ 0.3 A (Standby Supply) |
| Output Ripple & Noise (Max.) | 80 mV pk-pk (V1 @ full load, 20 MHz BW); ≤1% pk-pk (V1 & V3), ≤2% pk-pk (V2) |
| Output Voltage Tolerance | ±1% (V1); ±5% (V2); ±3% (V3) initial set accuracy |
| Line Regulation | ±0.5% (V1); ±3% (V2); ±3% (V3) |
| Load Regulation | ±1% (V1, 0–100% load); ±5% (V2, 10–100% load); ±3% (V3, 0–100% load) |
| Transient Recovery Time & Deviation | <500 µs to within 1% for 50%–75%–50% load step (4% max deviation, 1% over/undershoot) |
| Setup Time | 1 s typical, 2 s max (Start-up delay at 90 VAC full load) |
| Hold-Up Time (at 115 VAC) | 16 ms min, 20 ms typical (measured at 90 VAC full load; 26.8 ms typical on V1) |
| AC Input Voltage Range | 85 to 264 VAC (1-Phase, derate output power 10% below 90 VAC) |
| Input Frequency Range | 47 to 63 Hz (50/60 Hz nominal) |
| Efficiency | 86% typical at full load (up to 88% at 230 VAC) |
| AC Input Current (at 115 VAC) | 3.6 A max at full load |
| AC Input Current (at 230 VAC) | 1.8 A max at full load (100 mA max at no load) |
| Inrush Current (Cold Start at 230 VAC) | 60 A max (protected by internal T6.3A/250 V line fuse) |
| Power Factor Correction (PFC) | Active PFC, >0.9 (meets EN 61000-3-2 Class A; Class C for loads ≥20%) |
| Switching Frequency | 62 kHz (PFC stage) / 157 kHz (Main converter) |
| Power Density | 11.1 W/in³ |
| Mounting Style | Chassis Mount (Open U-Channel) |
| Cooling Method | Forced Air Cooling (13 CFM external airflow required for full 361 W rating) |
| Overall Width (W) | 81.3 mm (3.20 in) |
| Overall Height (H) | 38.1 mm (1.50 in) |
| Overall Depth (D) | 172.7 mm (6.80 in) |
| Net Weight | 612 g (1.35 lbs) |
| Termination / Connector Style | AMP/TE Connectors for J1 (AC Input) & J2 (DC Output); J3 Logic Header (optional -S suffix for screw terminals) |
| Output & Signal Terminal Pinout | J3 Logic Connector: Pin 1 AC OK Collector, Pin 2 Remote On/Off, Pin 4 DC OK Collector, Pin 7 AC/DC OK Emitter & Inhibit Return, Pin 9 +5V Standby, Pin 10 5V Standby Return |
| Control & Monitoring Signals | AC OK/Powerfail (open collector, ≥5 ms warning), DC OK (open collector), Remote On/Off (JP1 selectable inhibit/enable), Active Current Share (up to 3 units within 10%, derate to 90%), Remote Sense (0.5 V drop) |
| Overload Protection (OLP) Threshold | 110% to 140% of nominal output current (V1 only) |
| Overload Protection (OLP) Mode | Auto-recovery upon fault removal |
| Overvoltage Protection (OVP) Threshold | 115% to 140% of nominal output voltage (V1 only) |
| Overvoltage Protection (OVP) Mode | Latch-off (recycle AC input power to reset) |
| Overtemperature Protection (OTP) Mode | Thermal shutdown triggered at +75 °C via internal under-PCB sensor |
| Short Circuit Protection (SCP) | Continuous short-circuit protection with automatic recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC |
| Withstand Isolation Voltage (I/P to FG / Case) | 1500 VAC |
| Withstand Isolation Voltage (O/P to FG / Case) | 100 VDC |
| Earth Leakage Current | 1.0 mA max (at 230 VAC / 50 Hz) |
| Operating Ambient Temperature Range | -10 °C to +70 °C (14 °F to 158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (122 °F) with 13 CFM forced-air cooling |
| High-Temperature Derating Rate | Derate linearly at 2.5%/°C from +50 °C to 50% load at +70 °C |
| Low-Line Input Derating | Derate output power by 10% below 90 VAC (85–89 VAC) |
| Operating Altitude | Up to 3,000 m (9,842 ft) |
| Storage Temperature Range | -20 °C to +85 °C (-4 °F to 185 °F) |
| Operating Relative Humidity | 5% to 95% RH, non-condensing |
| Temperature Coefficient | ±0.05%/°C (Drift ±0.2% after 20 min warm-up) |
| Vibration Resistance | 10–500 Hz at 2 g, 10 sweeps along single axis; Shock: 30 g / 11 ms, 3 shocks each ± direction on 3 orthogonal axes (18 total) |
| Safety Approvals (UL / North America) | UL 62368-1, CAN/CSA C22.2 No. 62368-1-14 |
| Safety Approvals (IEC / EN / TÜV) | IEC 62368-1:2014, IEC 60950-1:2005 Ed. 2 (CB Report), TÜV EN 62368-1:2014/A11:2017, CE (LVD) |
| EMC Conducted & Radiated Emissions | EN 55032 Class B (Conducted), EN 55032 Class A (Radiated) |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A (Class C for loads ≥20%), EN 61000-3-3 |
| EMC Immunity Standards | EN 61000-4-4 Level 3 (Criteria A), EN 61000-4-5 Installation Class 3 (Criteria A), EN 61000-4-6 10 Vrms (Criteria A), EN 61000-4-11 Voltage Dips & Interruptions (30% 10 ms Criteria A; 60% 100 ms & 100% 5000 ms Criteria B) |
| MTBF (MIL-HDBK-217F) | 460,000 hours (Notice 2, +25 °C Ground Benign) |
| Environmental Compliance | RoHS Compliant |
Industrial Applications & Compatible Systems
XP Power MFA350PS12 is engineered for space-constrained industrial, broadcast, instrumentation, and IT systems requiring high-density 12 VDC bulk power alongside dedicated fan and standby rails:
- Industrial Automation & Machine Vision Controllers: Powers 12 VDC industrial PCs, vision cameras, solenoids, and actuator buses while utilizing the 5 V / 0.3 A standby rail for soft-power logic wake-up.
- 1U/2U Rackmount Telecom & Broadcast Equipment: Fits tightly inside low-profile 1.5-inch chassis heights, using the integrated 12 V / 1 A auxiliary output to drive system cooling fans without extra DC-DC converters.
- Redundant N+1 & Scalable Parallel Power Arrays: Connects up to three units in parallel via single-wire active current sharing for fault-tolerant test benches, server nodes, and semiconductor processing tools.
- Test, Measurement & Analytical Instrumentation: Delivers low-noise (80 mV pk-pk) regulated 12 VDC with EN 55032 Class B conducted emissions compliance to prevent interference in sensitive analog front-ends.
Installation, Thermal Management & MRO Guidelines
Proper airflow routing, parallel wiring, and upstream circuit protection ensure reliable full-load operation across the unit’s rated service life:
- Forced-Air Cooling & Thermal Derating: Supply at least 13 CFM of directed airflow across the U-channel chassis to achieve the full 361 W rating up to +50 °C, and derate linearly at 2.5%/°C between +50 °C and +70 °C.
- Parallel Current-Share & Remote Sense Wiring: When paralleling up to three MFA350PS12 units, link the Current Share and ±Sense pins on J3 using twisted pairs and derate combined maximum output current to 90% of nominal sum.
- Upstream Breaker Sizing & Low-Line Derating: Account for the 60 A cold-start inrush current (230 VAC) by specifying C-curve or D-curve miniature circuit breakers, and derate output power by 10% if operating continuously below 90 VAC.