DRP048V240W1BA Delta 240W 48VDC DIN Rail Power Supply

$138.44

Delta DRP048V240W1BA 240W 48VDC 5A CliQ II DIN rail power supply, 85-264VAC input, featuring 150% 5s Power Boost, conformal coating, and ATEX/Class I Div 2.

SKU: DRP048V240W1BA Category: Brand:

Description

Delta DRP048V240W1BA is an industrial-grade single-phase DIN rail power supply from the CliQ II Series, where the DRP prefix designates DIN Rail Power Supply, 048V240W denotes a 48 VDC / 240 W output rating, 1B identifies a single-phase CliQ II generation unit, and the A suffix specifies a corrosion-resistant aluminum enclosure with conformal-coated PCBAs and Class I, Division 2 / ATEX hazardous location certifications. Built around an active Power Factor Correction (PFC) front end coupled to a half-bridge LLC (HB-LLC) resonant converter topology, the supply accepts a universal 85–264 VAC (47–63 Hz) or 120–375 VDC input with zero low-line power derating. It delivers a continuous 48 VDC at 5.00 A (240 W) with an onboard potentiometer adjustment range of 48–56 VDC, plus a 150% Power Boost (7.50 A / 360 W for 5 seconds) to handle high-inrush inductive and capacitive loads up to 10,000 µF. Conversion efficiency exceeds 90.0% at 115 VAC and 92.0% at 230 VAC while maintaining ripple and noise below 200 mVpp, line regulation under 0.5%, and load regulation within 1.0%.

Housed in a rugged, lightweight full-aluminum chassis measuring 85 mm (W) × 121 mm (H) × 124.1 mm (D) (3.35 × 4.76 × 4.86 in) and weighing 0.96 kg (2.12 lb), the unit snaps directly onto standard TS-35 DIN rails (EN 60715). Pluggable screw terminal blocks accommodate 18–12 AWG conductors across a 3-pin bottom AC input block and a 4-pin top DC output block alongside a front-panel green DC OK LED indicator. Comprehensive self-recovering protection circuits safeguard against overload and short circuit (>150% rated current hiccup mode), overvoltage (<57 V SELV hiccup mode), and overtemperature (auto-recovery bounce mode), reinforced by 4.0 kVAC input-to-output and 1.5 kVAC input/output-to-ground galvanic isolation. Engineered for harsh environments from -25 °C to +80 °C (with extreme cold start at -40 °C and full-load operation up to +50 °C vertical), it holds UL 508, IEC/EN/UL 62368-1, Overvoltage Category III (EN 62477-1), ANSI/ISA 12.12.01 Class I Div 2, and ATEX II 3G Ex nA nC IIC T4 Gc approvals.

Key Features

  • 150% Reserve Power Boost Capability: Delivers 360 W (7.50 A at 48 VDC) for up to 5 seconds to reliably start high-inrush motors, solenoids, and capacitive loads up to 10,000 µF without upsizing the power supply.
  • ATEX & Class I Div 2 Hazardous Location Certified: Certified to ANSI/ISA 12.12.01 Class I, Division 2 (Groups A, B, C, D T4) and ATEX II 3G Ex nA nC IIC T4 Gc for deployment in petrochemical and explosive atmospheres.
  • Conformal-Coated PCBA & Aluminum Chassis: Precision dip-coated internal circuit boards and a corrosion-resistant aluminum enclosure shield electronics against chemical pollutants, moisture, conductive dust, and 30 G mechanical shock.
  • Wide-Range Input With Zero Low-Line Derating: Operates across 85–264 VAC (47–63 Hz), 2-of-3-phase systems, or 120–375 VDC while maintaining 100% full 240 W output capacity down to 85 VAC input.
  • Active PFC & 92% HB-LLC Conversion Efficiency: Integrates active power factor correction (>0.96 at 115 VAC, >0.90 at 230 VAC) with EN 61000-3-2 Class A harmonic compliance and >92.0% efficiency at 230 VAC.
  • Extreme -40 °C Cold Start & +80 °C Operation: Supports cold startup at -40 °C and continuous operation from -25 °C to +80 °C, delivering full 240 W power up to +50 °C in vertical TS-35 DIN rail orientation.
  • OVC III Safety & 4.0 kVAC Galvanic Isolation: Meets Overvoltage Category III per IEC/EN 62477-1 and EN 60204-1 with 4.0 kVAC input-to-output isolation, UL 508 listing, and >500,000-hour Telcordia SR-332 MTBF.
  • Parallel, Redundant & Series Operating Modes: Supports N+1 redundancy (via DRR-20N/20A ORing modules), active load-sharing parallel operation (within 25 mV balance), and series voltage stacking up to 150 VDC.

Technical Specifications

Manufacturer Delta
Manufacturer Part Number (MPN) DRP048V240W1BA
Compatible Equipment / Series Delta DRR-20N / DRR-20A Redundancy Modules, Industrial 48 VDC PoE Switches, Telecom & Process Control Cabinets
Product Series CliQ II Series
Product Category Single-Phase DIN Rail
Component Type Industrial Single-Phase AC-DC DIN Rail Power Supply (Hazardous Location Rated)
Circuit Topology Active PFC Boost Pre-Regulator + Half-Bridge LLC (HB-LLC) Resonant Converter
Nominal Output Voltage 48 VDC
Output Voltage Adjustment Range 48 to 56 VDC (via front-panel potentiometer)
Rated Output Current 5.00 A (continuous at 48 VDC)
Peak / Surge Output Current 7.50 A (150% Power Boost for 5 seconds at 48 VDC)
Rated Output Power 240 W (continuous at 48 VDC)
Peak Output Power 360 W (150% Power Boost for 5 seconds at 48 VDC; 288 W at 120% for 10 seconds)
Number of Outputs 1 (Single Output with dual +V and -V terminal pairs)
Output Ripple & Noise (Max.) < 200 mVpp (PARD at 20 MHz bandwidth, terminated with 0.1 µF ceramic & 47 µF electrolytic capacitors)
Output Voltage Tolerance ± 1.0% (Factory set point tolerance at 48 VDC)
Line Regulation < 0.5% (at 85–264 VAC input, 100% load)
Load Regulation < 1.0% (at 85–264 VAC input, 0–100% load); Dynamic Response ± 2% (10–100% load, 0.1 A/µs, 5 Hz)
Setup Time < 1,000 ms (at nominal 115 / 230 VAC input, 100% load)
Rise Time < 200 ms (at nominal 115 / 230 VAC input, 100% load)
Hold-Up Time (at 115 VAC) > 20 ms (at 115 / 230 VAC, 100% load)
Max. Capacitive Load 10,000 µF
AC Input Voltage Range 85 to 264 VAC (Single-Phase or 2-of-3-Phase system up to 240 VAC +10%)
DC Input Voltage Range 120 to 375 VDC (Connect +pole to L, -pole to N, and PE to earth)
Nominal Input Voltage 100 to 240 VAC
Input Frequency Range 47 to 63 Hz (50–60 Hz nominal)
Efficiency (at 115 VAC) > 90.0% (at 100% load; Max Power Dissipation < 25 W)
Efficiency (at 230 VAC) > 92.0% (at 100% load; Max Power Dissipation < 19 W)
AC Input Current (at 115 VAC) < 2.50 A (at 100% load)
AC Input Current (at 230 VAC) < 1.30 A (at 100% load)
Inrush Current (Cold Start at 115 VAC) < 35 A (at 115 VAC & 230 VAC cold start)
Power Factor (PF at 115 VAC) > 0.96 (at 100% load)
Power Factor (PF at 230 VAC) > 0.90 (at 100% load)
Power Factor Correction (PFC) Active PFC (Conforms to IEC/EN 61000-3-2 Class A)
No-Load Power Consumption < 6.5 W (at 115 VAC), < 5.5 W (at 230 VAC)
Mounting Style DIN Rail TS-35 (35 mm standard rail in accordance with EN 60715)
Cooling Method Free Air Convection (Natural convection; acoustic noise SPL < 40 dBA at 1 m)
Overall Width (W) 85.0 mm (3.35 in)
Overall Height (H) 121.0 mm (4.76 in)
Overall Depth (D) 124.1 mm (4.86 in)
Net Weight 0.96 kg (2.12 lb)
Termination / Connector Style Pluggable Screw Terminal Blocks (Rated 300 V / 15 A per pin)
Input Terminal Pinout Bottom Terminal Block (3-Pin): L (Line, with internal T 6.3 A H fuse), N (Neutral), PE (Primary Earth)
Output & Signal Terminal Pinout Top Terminal Block (4-Pin): +V (2 pins), -V / RETURN (2 pins)
Status Indicator Green LED (DC OK front-panel status indicator)
Terminal Wire Gauge Range AWG 18–12 (Flexible cables require ferrules per EN/UL 62368-1)
Enclosure / Potting Material Full Corrosion-Resistant Aluminium Chassis with Conformal-Coated PCBA
Overload Protection (OLP) Threshold > 150% of rated load current (> 7.50 A)
Overload Protection (OLP) Mode Hiccup Mode, Non-Latching (Auto-Recovery upon fault removal)
Overvoltage Protection (OVP) Threshold < 57 VDC (SELV Output)
Overvoltage Protection (OVP) Mode Hiccup Mode, Non-Latching (Auto-Recovery)
Overtemperature Protection (OTP) Mode Bouncing Mode, Non-Latching (Auto-Recovery when ambient temperature drops below < 80 °C limit)
Short Circuit Protection (SCP) Hiccup Mode, Non-Latching (Auto-Recovery when short circuit is removed)
Withstand Isolation Voltage (I/P to O/P) 4.0 kVAC (SELV / TNV-1 circuit isolation)
Withstand Isolation Voltage (I/P to FG / Case) 1.5 kVAC (Class I with PE connection)
Withstand Isolation Voltage (O/P to FG / Case) 1.5 kVAC
Earth Leakage Current < 1.0 mA (at 240 VAC)
Operating Ambient Temperature Range -25 °C to +80 °C (-13 °F to +176 °F); Extreme low-temperature cold start at -40 °C (-40 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) for Vertical Mounting; +40 °C (+104 °F) for Horizontal Mounting
High-Temperature Derating Rate 2.5% / °C above +50 °C (Vertical Mounting); 2.5% / °C above +40 °C (Horizontal Mounting)
Low-Line Input Derating Zero derating across entire 85–264 VAC input voltage range (100% load at 85 VAC)
Altitude Derating 0 to 2,500 m (0 to 8,200 ft) operating altitude; Overvoltage Category III (IEC/EN 62477-1), Pollution Degree 2
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 5% to 95% RH (Non-condensing)
Vibration Resistance Vibration: IEC 60068-2-6 (10–500 Hz, 3 G peak, 0.35 mm, 60 min/axis); Shock: IEC 60068-2-27 (30 G, 18 ms); Bump: IEC 60068-2-29 (10 G, 11 ms, 6,000 bumps)
Ingress Protection (IP) IP20 (Requires installation inside an IP54 enclosure/cabinet for ATEX / Class I Div 2 compliance)
Safety Approvals (UL / North America) UL 508 & CSA C22.2 No. 107.1-01 Listed (File E315355), UL/cUL 62368-1 & 60950-1 Recognized (File E191395), cCSAus Class I Div 2 Groups A, B, C, D T4 (CSA C22.2 No. 213 / ANSI/ISA 12.12.01)
Safety Approvals (IEC / EN / TÜV) ATEX II 3G Ex nA nC IIC T4 Gc (EN 60079-0, EN 60079-15, Cert. EPS 12 ATEX 1 491 X), SIQ Bauart EN 62368-1, CB Scheme IEC 60950-1 & IEC 62368-1, EN 60204-1 (OVC III), IEC/EN 62477-1, IEC 62103
Safety Approvals (Regional / Global) CE (LVD 2014/35/EU, EMC 2014/30/EU, ATEX 2014/34/EU), UKCA, BIS IS 13252-1, KC K 60950-1, CSA File 181564
EMC Conducted & Radiated Emissions CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B, KN 32, CNS 13438, EN/BS EN 61204-3
EMC Harmonic & Flicker Compliance IEC/EN/BS EN 61000-3-2 Class A (Harmonic Current), IEC/EN/BS EN 61000-3-3 (Voltage Fluctuation & Flicker)
EMC Immunity Standards EN 55024, EN 61000-6-1, EN 61000-6-2, KN 35; IEC 61000-4-2 (ESD Level 4: 15 kV Air / 8 kV Contact, Criteria A), IEC 61000-4-3 (Radiated 10 V/m, Level 3, Criteria A), IEC 61000-4-4 (EFT 2 kV, Level 3, Criteria A), IEC 61000-4-5 (Surge Level 3: 2 kV CM / 1 kV DM, Criteria A), IEC 61000-4-6 (Conducted 10 Vrms, Level 3, Criteria A), IEC 61000-4-8 (Magnetic 30 A/m, Criteria A), IEC 61000-4-11 (100% Dip 20 ms, Self-Recoverable), IEC 61000-4-12 (Ring Wave Level 3: 2 kV CM / 1 kV DM, Criteria A)
MTBF (Telcordia SR-332 / Bellcore) > 500,000 hours (at 115 & 230 VAC input, 100% load, 25 °C ambient); Expected Capacitor Lifetime: 10 years (50% load at 40 °C)
Environmental Compliance CE, UKCA, RoHS Compliant, Conformal-Coated PCBA for corrosive/dusty industrial atmospheres

Industrial Applications & Compatible Systems

The Delta DRP048V240W1BA is engineered for mission-critical 48 VDC industrial automation, telecommunications, and hazardous-location control architectures requiring high transient reserve power and rugged environmental protection:

  • Oil, Gas & Petrochemical Hazardous Locations: Certified to Class I, Division 2 (Groups A–D, T4) and ATEX Zone 2 (II 3G Ex nA nC IIC T4 Gc) with conformal-coated PCBAs for remote terminal units (RTUs), valve actuators, and refinery instrumentation cabinets.
  • Industrial PoE / PoE+ Network Switches & Telecom Infrastructure: Provides tightly regulated 48–56 VDC SELV/TNV-1 power with <200 mVpp ripple to drive managed industrial Ethernet switches, IP surveillance backbones, and 48 VDC telecom rectifiers.
  • High-Inrush Motion Control & Factory Automation: Utilizes 150% Power Boost (360 W / 7.50 A for 5 seconds) to start 48 VDC stepper/servo drives, pneumatic solenoid manifolds, contactors, and capacitive DC bus loads up to 10,000 µF without nuisance tripping.
  • Marine, Wastewater & Chemical Processing Panels: Conformal-coated electronics and a full aluminum housing resist corrosive salt spray, hydrogen sulfide moisture, and 3 G vibration in harsh process control enclosures.

Installation, Thermal Management & MRO Guidelines

To ensure long-term operational reliability, thermal stability, and regulatory compliance, observe the following engineering and MRO installation guidelines:

  • Convection Cooling Clearances & Thermal Derating: Maintain at least 50 mm (1.97 in) vertical clearance (above/below) and 20 mm (0.79 in) lateral clearance in standard vertical mounting (or 20 mm above/below and 50 mm lateral in horizontal mounting), and derate output load by 2.5% per °C above +50 °C vertical (+40 °C horizontal).
  • Branch Circuit Protection & Neutral Fusing: The AC Line (L) pin integrates a non-replaceable T 6.3 A H fuse approved for 20 A (UL) and 16 A (IEC) branch circuits; when using an external breaker, select at least an 8 A B-curve or 6 A C-curve MCB, and install an external fuse in series with the Neutral (N) line during 2-of-3-phase or DC input operation.
  • ATEX / Class I Div 2 Enclosure & Wiring Compliance: For hazardous locations, mount the PSU inside a tool-secured IP54 minimum enclosure compliant with EN 60079-0/15, terminate 18–12 AWG flexible copper conductors with ferrules before plugging in connectors, and never disconnect terminals or adjust the voltage potentiometer while energized.
  • Redundant & Parallel Load-Sharing Setup: For N+1 redundancy with a Delta DRR-20N or DRR-20A module, set the master PSU output 0.90–1.00 V higher than the slave unit (accounting for the 0.60–0.90 V ORing drop); for direct parallel power expansion, match both PSU voltages within 25 mV at 50% load.