Description
TDK-Lambda FPS1000-24/P (also known as FPS100024P) is a 960W, 24VDC 1U front-end hot-swap AC-DC power supply engineered for high-density industrial rack systems and N+1 redundant power architectures. Within the FPS1000 nomenclature, the -24 designator specifies a 24VDC nominal output adjustable from 21.5V to 29VDC via the output trim pin at up to 40A continuous current, while the /P suffix identifies the front-panel IEC320-C14 AC inlet configuration without an I2C interface. Built with active power factor correction (>0.98 at full load) and internal ORing diodes with active current sharing, the module accepts universal 85–265VAC (47–63Hz) or 120–360VDC input, achieves up to 86% efficiency at 230VAC (83% at 115VAC), and maintains <0.4% line regulation, <0.8% load regulation, and 200mVp-p ripple and noise.
Comprehensive fault protection includes 104–125% overcurrent protection, 31–34VDC overvoltage protection, and automatic-recovery overtemperature protection, alongside 3kVAC input-to-output, 2kVAC input-to-ground, and 500VAC output-to-ground dielectric isolation. Front-to-rear variable-speed fan cooling supports 100% continuous output from 0°C to +50°C (32°F to +122°F) with a linear 2%/°C derating slope up to +60°C (+140°F) on /P models, plus a 90% load derating threshold below 100VAC line input. Housed in a compact 1U chassis measuring 127.0 × 41.0 × 290.0 mm (5.0 × 1.61 × 11.4 in) with a Positronic PCIB24W9M400A1 blind-mate rear power/signal connector, the unit is certified to IEC/UL/CSA/EN 62368-1, 60950-1, CE, UKCA, and EN 55032 Class B standards.
Key Features
- High-Density 960W 24VDC Output: Delivers 40A continuous current adjustable from 21.5V to 29VDC via trim pin with <0.4% line regulation, <0.8% load regulation, and 200mV ripple.
- Front-Panel IEC320-C14 AC Inlet (/P Variant): Features a front-accessible IEC320-C14 AC receptacle with optional cable lock and front-to-rear variable-speed fan airflow for streamlined 19-inch rack integration.
- Hot-Swap N+1 Redundancy & Parallel Sharing: Integrated internal ORing diodes and active current sharing support hot-swappable N+1 redundancy or bulk parallel scaling up to eight FPS1000 units.
- Active PFC & Universal Wide-Range Input: Operates across 85–265VAC (47–63Hz) and 120–360VDC with >0.98 power factor, EN 61000-3-2 Class A harmonic compliance, and 86% efficiency at 230VAC.
- Comprehensive Supervisory Signals & 12V Standby: Provides an always-on isolated 12V (11.2–12.5V) 0.25A auxiliary output, remote sense, remote on/off, and open-collector DC OK, AC Fail, and Overtemperature warnings.
- Industrial Protection & 3kVAC Isolation: Incorporates 104–125% overcurrent protection, 31–34V overvoltage protection, auto-reset thermal protection, and 3kVAC input-to-output reinforced isolation.
- Global Safety & Class B EMC Compliance: Certified to IEC/UL/CSA/EN 62368-1 and 60950-1 with CE/UKCA markings, EN 55032/FCC Part 15J/VCCI Class B emissions, and ±4kV surge immunity.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | FPS1000-24/P |
| Alternate Part Number | FPS100024P |
| Product Series | FPS1000 Series |
| Product Category | Rackmount Power Supplies |
| Component Type | 1U Front-End Hot-Swap AC-DC Power Supply |
| MPN Configuration Suffixes | -24 (24VDC Output), /P (Front IEC320-C14 AC Inlet Connector; No I2C Interface) |
| Compatible 19-Inch Rack Shelves | FPS-S1U/P (3-Slot Single-Output 1U Rack), FPS-T1U/P (3-Slot Triple Floating-Output 1U Rack) |
| Circuit Topology | Active PFC + Isolated Switching Front-End with Internal ORing Diodes & Current Share |
| Nominal Output Voltage | 24 VDC |
| Output Voltage Adjustment Range | 21.5 to 29 VDC (Adjusted via V_TRIM Pin on Output Connector) |
| Rated Output Current | 40 A |
| Output Current Range | 0 to 40 A (No Minimum Load Required) |
| Rated Output Power | 960 W |
| Output Ripple & Noise (Max) | 200 mVp-p |
| Line Regulation | < 0.4% |
| Load Regulation | < 0.8% |
| Temperature Coefficient | < 0.02% / °C |
| Minimum Load Requirement | 0 A (No Minimum Load Required) |
| Standby / Auxiliary Output Voltage | 12 VDC (11.2 to 12.5 VDC) @ 0.25 A, Isolated (Always On) |
| Hold-Up Time (at 100 VAC Input) | 20 ms typical (at 800 W loading) |
| Parallel & Redundant Operation | Hot-Swap Capable with Internal ORing Diodes & Current Sharing (Up to 8 Units in Parallel) |
| AC Input Voltage Range | 85 to 265 VAC (Derate linearly to 90% load below 100 VAC) |
| DC Input Voltage Range | 120 to 360 VDC (Note: Safety certified for AC input 47–63 Hz only) |
| Input Frequency Range | 47 to 63 Hz (47 to 440 Hz with reduced PFC at 100–265 VAC) |
| Efficiency (Typical at 115 VAC / 100 VAC) | 83% |
| Efficiency (Typical at 230 VAC / 200 VAC) | 86% |
| AC Input Current (at 100 VAC) | 12 A |
| AC Input Current (at 200 VAC) | 6 A |
| Inrush Current (Cold Start) | < 40 A |
| Power Factor (PF at Full Load) | > 0.98 (Active Power Factor Correction) |
| Overcurrent / Overload Protection (OLP) Threshold | 104% to 125% of Maximum Output Current |
| Overvoltage Protection (OVP) Threshold | 31 to 34 VDC |
| Overtemperature Protection (OTP) Mode | Yes, Automatic Reset |
| Insulation Class | Class I (Requires Protective Earth Connection) |
| Withstand Isolation Voltage (Input to Output) | 3 kVAC (3,000 VAC for 1 minute) |
| Withstand Isolation Voltage (Input to Ground / FG) | 2 kVAC (2,000 VAC for 1 minute) |
| Withstand Isolation Voltage (Output to Ground / FG) | 500 VAC (for 1 minute) |
| Isolation Resistance | > 100 MΩ at 25 °C, 70% RH (Output to Ground at 500 VDC) |
| Earth Leakage Current | < 1.1 mA at 230 VAC Input |
| Operating Ambient Temperature (/P Models) | 0 °C to +60 °C (+32 °F to +140 °F) with Derating |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% Rated Load |
| High-Temperature Derating Rate (/P Models) | Derate linearly at 2% / °C from +50 °C to +60 °C (+122 °F to +140 °F) |
| Low-Line Input Derating | Derate linearly to 90% load below 100 VAC (85 to 100 VAC) |
| Storage Temperature Range | -30 °C to +85 °C (-22 °F to +185 °F) |
| Operating Relative Humidity | 10% to 90% RH (Non-Condensing) |
| Storage Relative Humidity | 10% to 95% RH (Non-Condensing) |
| Maximum Operating Altitude | 3,000 m (9,842 ft) |
| Vibration Resistance (Non-Operating) | Meets ETS 300 019 |
| Mechanical Shock Resistance | Meets ETS 300 019 |
| MTBF (JEITA Standard) | 79,395 Hours |
| Safety Certifications & Agency Approvals | UL 62368-1, CSA 62368-1, IEC/EN 62368-1, IEC/UL/CSA/EN 60950-1, CE Mark, UKCA Mark |
| Conducted & Radiated EMI Emissions | EN 55032 Class B, FCC Part 15 Subpart J Class B, VCCI Class B |
| Harmonic Current Emissions (EN 61000-3-2) | Meets EN 61000-3-2 Class A (20% to 100% Load) |
| ESD Immunity (EN 61000-4-2) | ±8 kV Air Discharge, ±6 kV Contact Discharge (Performance Criteria B) |
| Radiated RF Immunity (EN 61000-4-3) | 3 V/m (Performance Criteria B) |
| EFT / Burst Immunity (EN 61000-4-4) | ±2 kV (Performance Criteria B) |
| Surge Immunity (EN 61000-4-5) | ±4 kV Common Mode, ±2 kV Differential Mode (Performance Criteria B) |
| Conducted RF Immunity (EN 61000-4-6) | 3 Vrms, 150 kHz to 80 MHz (Performance Criteria B) |
| Remote Sense Function | Yes (+S Pin 8, -S Pin 13; Must be connected for proper operation) |
| Remote On/Off Control | ON = 0 to 0.6 V or Short; OFF = 2 to 15 V or Open (Max Sink Current: 2.6 mA) |
| DC OK Supervisory Signal | Open Collector Signal; ON when Vout > 80% ±5% of Rated Output (Max Sink Current: 10 mA) |
| AC Fail & Overtemperature Warning Signals | Open Collector Signals (AC_FAIL Pin 11, TEMP_ALARM Pin 12) |
| Front-Panel Status Indicators | LED Indicators for AC OK, DC OK, and DC Fail |
| AC Input Connector (/P Model) | Front-Panel IEC320-C14 AC Inlet with AC Cable Lock Option (Rear Pins 22–24 NC) |
| Rear Output & Signal Connector | Positronic PCIB24W9M400A1 (Mating Female Connector: PCIB24W9F400A1) |
| Rear Connector Power & Signal Pinout | Pins 1,2,4: +V; Pins 3,5,6: -V; Pin 7: ON/OFF; Pin 8: +S; Pin 9: DC_OK; Pin 10: SIGNAL_RTN; Pin 11: AC_FAIL; Pin 12: TEMP_ALARM; Pin 13: -S; Pin 14: V_TRIM; Pin 15: CS; Pin 16: +12V_AUX; Pins 17–21: I2C (Inactive on non-/S); Pins 22–24: NC |
| Cooling Method & Airflow Direction | Forced Air Cooling via Internal Variable-Speed Fans (Front-to-Rear Airflow) |
| Form Factor & Mounting Style | 1U Front-End Plug-In Module (Rackmount in FPS-S1U/P or FPS-T1U/P, or Chassis Mount via 3x M3 Holes) |
| Overall Width (W) | 127.0 mm ±0.3 mm (5.00 in) |
| Overall Height (H) | 41.0 mm ±0.5 mm (1.61 in / 1U) |
| Overall Depth / Length (D/L) | 290.0 mm ±0.5 mm Chassis Body (11.42 in); 319.2 mm ±1.0 mm Overall Incl. Front Handle & Rear Connector (12.57 in) |
| Chassis Mounting Hole Specification | 3x M3 Threaded Mounting Holes (Maximum Screw Penetration: 3.0 mm) |
| Minimum Airflow Clearance | 50 mm (1.97 in) Unrestricted Air Space at Rear of Unit; Do Not Obstruct Front Panel Intake |
| Net Weight | 2,000 g / 2.00 kg (4.41 lbs) |
| Manufacturer Warranty | 2 Years |
Industrial Applications & Compatible Systems
TDK-Lambda FPS1000-24/P provides high-density, hot-swappable 24VDC bulk and redundant power for 19-inch rackmount industrial and automated test infrastructure:
- 19-Inch Industrial Rack Systems & N+1 Bulk Power: Populates TDK-Lambda FPS-S1U/P or FPS-T1U/P 1U shelves to deliver up to 2,880W (3 × 960W) of parallel bulk 24VDC power or 1,920W N+1 hot-swap redundant capacity.
- Semiconductor Fabrication & Automated Test Equipment (ATE): Supplies low-ripple (200mV), tightly regulated 24VDC power with remote voltage sensing and trim capability to wafer handling tools, burn-in racks, and test instrumentation.
- Factory Automation, Robotics & Process Control Cabinets: Powers distributed 24VDC I/O racks, industrial controllers, solenoid banks, and HMI consoles requiring front-panel IEC320-C14 AC cord access and open-collector DC OK / AC Fail telemetry.
- Broadcast, Telecom & Industrial Computing Infrastructure: Delivers Class B EMC-compliant 24VDC power with an always-on isolated 12V auxiliary rail for rack-level supervisory controllers and cooling management.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: When integrating the FPS1000-24/P into an enclosure or 1U rack shelf, maintain at least 50 mm (1.97 in) of unobstructed exhaust clearance behind the rear panel and keep the front intake grille clear to support front-to-rear variable-speed fan cooling. For standalone chassis mounting via the three M3 bottom holes, restrict screw penetration to 3.0 mm maximum to avoid internal PCB clearance hazards. Connect the remote sense pins (+S Pin 8 and -S Pin 13) directly to the load or rack busbar, as open sense lines will prevent proper voltage regulation, and apply a 2%/°C linear load derating above +50°C up to +60°C (plus 10% load derating when operating between 85VAC and 100VAC).