HDL3000PS48 XP Power 3000W 48VDC Chassis Power Supply

$1,219.15

XP Power HDL3000PS48 3000W 48VDC 62.5A programmable chassis-mount AC-DC power supply, 90-264VAC input, 92% efficiency, I2C/analog control.

SKU: HDL3000PS48 Category: Brand:

Description

XP Power HDL3000PS48 is a high-density, programmable 3000W single-output chassis-mount AC-DC power supply from the HDL3000 Series, engineered for precision industrial power and automated test systems. Delivering a nominal 48 VDC output at 62.5 A on high-line input (180–264 VAC) and derating linearly down to 2000 W (41.6 A) at 90 VAC low line, this unit achieves 92% efficiency at 230 VAC full load with active power factor correction (0.98 at 115 VAC / 0.95 at 230 VAC). Its variable-frequency PWM power stage (40–200 kHz) and 65 kHz PFC stage maintain tight ±1% line and load regulation alongside 480 mV pk-pk maximum ripple and noise. Users can dynamically program both output voltage and output current from 0% to 105% via external 0–5 VDC analog signals, 0–5 kΩ external resistance, or an integrated I²C digital interface.

Housed in a compact, fan-cooled enclosed chassis measuring 316.5 × 170.0 × 63.5 mm (12.46 × 6.69 × 2.50 in) and weighing 3.6 kg (7.94 lbs), the unit incorporates intelligent load- and temperature-controlled fan speed management. Heavy-duty M8 screw terminals handle high-current DC output delivery, while a 24-pin JST CN2 header provides remote sense (compensating up to 0.5 V drop), remote inhibit/enable, Power OK open-drain signaling, active single-wire current sharing for up to 5 parallel units, and a user-selectable 5 VDC / 0.5 A or 9 VDC / 0.3 A standby rail. Comprehensive protection includes 105% constant-current overload, auto-recovering short-circuit and overtemperature shutdown, and tracking overvoltage protection, backed by 3000 VAC input-to-output isolation, a -20 °C to +60 °C (-4 °F to +140 °F) operating temperature range (full power to +50 °C), and global UL/CSA/IEC/EN 62368-1 safety certifications.

Key Features

  • Full-Range Analog & Digital Programmability: Supports 0% to 105% output voltage and current programming via 0–5 VDC external voltage, 0–5 kΩ resistance, or I²C bus interface.
  • High-Power 48 VDC Output & High Efficiency: Delivers 3000 W (62.5 A) at 180–264 VAC and 2000 W (41.6 A) at 90 VAC low line with 92% efficiency.
  • Scalable Parallel Current Sharing: Built-in ORing diode and active current-share bus allow up to five units to operate in parallel within 5% sharing accuracy.
  • Comprehensive Control & Standby Signals: Includes remote on/off inhibit, open-drain Power OK status, 0.5 V remote sense compensation, and selectable 5 VDC (0.5 A) or 9 VDC (0.3 A) standby output.
  • Robust Multi-Mode Protection Suite: Features 105% constant-current overload protection, tracking overvoltage shutdown (AC recycle reset), and auto-recovering short-circuit and dual-heatsink overtemperature protection.
  • High Power Density & Intelligent Cooling: Packs 36.5 W/cm³ (598.1 W/in³) into a low-profile 63.5 mm (2.5 in) chassis with load- and temperature-regulated internal cooling fans.
  • Industrial Thermal & Altitude Endurance: Operates from -20 °C to +60 °C (-4 °F to +140 °F) with full 3000 W power up to +50 °C (+122 °F) and up to 3100 m altitude.
  • Global ITE Safety & EMC Compliance: Certified to UL 62368-1, CAN/CSA C22.2 No. 62368-1-14, IEC/EN 62368-1, CE, UKCA, and EN 55032 Class A emissions.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) HDL3000PS48
Product Series HDL3000 Series
Product Category Chassis Power Supplies
Component Type Programmable Chassis-Mount AC-DC Power Supply
Circuit Topology Active PFC (65 kHz) + Variable-Frequency PWM Switching (40–200 kHz) with Built-in ORing Diode
Nominal Output Voltage 48 VDC
Output Voltage Adjustment Range ±5% via onboard potentiometer; 0% to 105% (0 to 50.4 VDC) via external voltage, resistance, or I²C programming
Rated Output Current 62.5 A (at 180–264 VAC high line); 41.6 A (at 90 VAC low line)
Output Current Range 0 to 62.5 A (0% to 105% programmable current limit)
Rated Output Power 3000 W (at 180–264 VAC high line); 2000 W (at 90 VAC low line)
Number of Outputs 1 Main Output + 1 Auxiliary Standby Output
Ch1 Output Voltage & Current 48 VDC @ 62.5 A (Main Output)
Ch2 Output Voltage & Current 5 VDC @ 0.5 A default or 9 VDC @ 0.3 A user-selectable (Auxiliary Standby Output, always active with AC mains)
Output Ripple & Noise (Max.) 480 mV pk-pk (20 MHz bandwidth, 300 mm twisted pair with 0.1 µF ceramic & 47 µF electrolytic capacitors at +25 °C)
Output Voltage Tolerance ±2% (includes setup time tolerance, line regulation, and load regulation)
Line Regulation ±1%
Load Regulation ±1% (Main V1 Output); ±3% (Auxiliary Standby Output, 0–100% load)
Transient Recovery Time & Deviation <1% maximum voltage deviation for a 25% step load change
Setup Time 1000 ms (1 s start-up delay)
Rise Time 120 ms (at full load)
Hold-Up Time (at 230 VAC) 10 ms min. / 11 ms typ. (at full load)
AC Input Voltage Range 90 to 264 VAC (Single-Phase)
Input Frequency Range 47 to 63 Hz
Efficiency 92% typ. (at 230 VAC, full load)
AC Input Current (at 115 VAC) 19.7 A (at 2000 W low-line load)
AC Input Current (at 230 VAC) 15.0 A (at 3000 W full load)
Inrush Current (Cold Start at 115 VAC) 43 A
Inrush Current (Cold Start at 230 VAC) 110 A
Power Factor (PF at 115 VAC) 0.98 (at full load)
Power Factor (PF at 230 VAC) 0.95 (at full load)
Power Factor Correction (PFC) Active PFC (65 kHz)
Switching Frequency 65 kHz (PFC stage); 40 to 200 kHz variable (PWM stage)
Mounting Style Chassis Mount (bottom and side M4 mounting holes, max screw penetration 3.0 mm / 0.12 in)
Cooling Method Forced-air cooling via internal intelligent variable-speed fans (speed scales with load and internal temperature)
Overall Width (W) 170.0 mm (6.69 in)
Overall Height (H) 63.5 mm (2.50 in)
Overall Depth (D) 316.5 mm (12.46 in) including connectors
Mounting Hole Pitch Bottom: 237.0 × 78.0 mm (9.33 × 3.07 in, 4× M4); Sides: 208.0 × 35.0 mm (8.19 × 1.38 in, 8× M4)
Net Weight 3.6 kg (7.94 lbs)
Termination / Connector Style AC Input: 3-pin M4 screw barrier block (11.0 mm pitch); DC Output: M8 slotted/Posidriv busbar screws; Signals: 24-pin JST PHDR-24VS header (CN2)
Input Terminal Pinout 3-Pin AC Barrier Block — Pin 1: FG (Earth Ground), Pin 2: ACL (Line), Pin 3: ACN (Neutral)
Output & Signal Terminal Pinout DC Busbars: +VO / -VO (M8 screws); CN2 24-Pin Control Header — Pin 1: VS+, Pin 2: VO+, Pin 3: VS-, Pin 4: VO-, Pin 5: POK, Pin 6/10/14/16/18/22: GND, Pin 7: PAR, Pin 8: VSET, Pin 9: EN-, Pin 11: EN+, Pin 12/17/21: AUX, Pin 13: ACI, Pin 15: VCI, Pin 19: SCL, Pin 20: SDA, Pin 23: RX*, Pin 24: TX* (*RS232/RS485 driver board only)
Control & Monitoring Signals Remote Sense (0.5 V max drop compensation), Remote On/Off Inhibit (EN+/EN-), Power OK (open-drain, 40 V / 20 mA max), Active Current Share (PAR, up to 5 units within 5%), Analog V/I Program (0–5 VDC or 0–5 kΩ), Standby Voltage Select (VSET)
Communication Interface I²C Serial Bus (SCL / SDA on CN2 Pins 19–20); optional RS232 / RS485 via KIT-RS232-X or KIT-RS485-1 driver boards
Status Indicator Multi-color LED (Solid Green: Output OK; Solid Orange: Remote Control OK; Slow Blink Green/Orange: Disabled; Red Blink/Solid codes: OVP, OLP, OTP, Fan Fail, AUX Fail)
Terminal Tightening Torque AC Input M4 screws: 1.3 Nm max; DC Output M8 screws: 3.0 Nm (30.5 kgf·cm); Chassis Mounting M4 screws: 1.27 Nm (13.0 kgf·cm)
Overload Protection (OLP) Threshold 105% of rated output power
Overload Protection (OLP) Mode Constant current limiting
Overvoltage Protection (OVP) Threshold Tracks programmed output voltage (114%–120% at 100%–105% Vout; scales up to 196%–200% near 7% Vout)
Overvoltage Protection (OVP) Mode Latching shutdown (recycle AC input power to reset)
Overtemperature Protection (OTP) Mode Monitors primary and secondary heatsinks; output shuts down and auto-recovers upon cooling
Short Circuit Protection (SCP) Continuous protection with automatic recovery upon fault removal
Withstand Isolation Voltage (I/P to O/P) 3000 VAC
Withstand Isolation Voltage (I/P to FG / Case) 1500 VAC
Withstand Isolation Voltage (O/P to FG / Case) 500 VAC
Earth Leakage Current <3 mA (at 264 VAC, 60 Hz)
Operating Ambient Temperature Range -20 °C to +60 °C (-4 °F to +140 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F)
High-Temperature Derating Rate Derates linearly from 100% load (3000 W) at +50 °C (+122 °F) to 50% load (1500 W) at +60 °C (+140 °F)
Low-Line Input Derating Derates linearly from 3000 W (62.5 A) at 180 VAC down to 2000 W (41.6 A) at 90 VAC
Altitude Derating Rated for operation up to 3100 m (10,170 ft) maximum operating altitude
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 20% to 90% RH (non-condensing)
Temperature Coefficient ±0.02% / °C (0 °C to +50 °C)
Vibration Resistance 2 g, 10–500 Hz (10 min/cycle, 60 min per axis, compliant to IEC 60068-2-16 and IEC 60068-2-64)
Safety Approvals (UL / North America) UL 62368-1, CAN/CSA C22.2 No. 62368-1-14 (cULus)
Safety Approvals (IEC / EN / TÜV) IEC 62368-1:2014 (CB Report), TÜV EN 62368-1:2014/A11:2017
Safety Approvals (Regional / Global) CE, UKCA
EMC Conducted & Radiated Emissions EN 55032 Class A (Conducted and Radiated)
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker)
EMC Immunity Standards EN 55024: EN 61000-4-2 Level 2/3 (±4 kV contact, ±8 kV air, Criteria A), EN 61000-4-3 Level 3 (10 V/m, Criteria A), EN 61000-4-4 Level 3 (Criteria A), EN 61000-4-5 Installation Class 3 (Criteria A), EN 61000-4-6 Level 3 (10 V, Criteria A), EN 61000-4-8 (30 A/m, Criteria A), EN 61000-4-11 (30% dip 500 ms Criteria A; >95% int 10 ms Criteria A; >95% int 5000 ms Criteria B)
MTBF (MIL-HDBK-217F) 90,000 hours (at +25 °C, Ground Benign)

Industrial Applications & Compatible Systems

Engineered for high-power industrial automation, programmable DC power distribution, and precision process control, the XP Power HDL3000PS48 integrates into demanding OEM and MRO environments:

  • Battery Simulation & EV Component Testing: Programmable 0–105% voltage (0–50.4 VDC) and constant-current limiting (0–62.5 A) via I²C or 0–5 VDC analog signals support automated battery pack emulation and charge/discharge cycling.
  • Industrial Laser & UV/LED Curing Systems: High-density 3000 W 48 VDC power delivery with tight ±1% regulation and low ripple powers high-power diode laser drivers and specialist industrial LED heating arrays.
  • Heavy Robotics & Automated Manufacturing Cells: Parallel current-sharing capability up to 15 kW (5 units) with built-in ORing diodes provides redundant, high-current 48 VDC bus power for multi-axis robotic controllers and servo drives.
  • Electro-Plating, Cathodic Protection & Burn-In Racks: Continuous constant-current operation and remote voltage/current trimming enable precise current-density control in electrochemical tanks and semiconductor burn-in chambers.

Installation, Thermal Management & MRO Guidelines

Proper mechanical, electrical, and thermal integration ensures long-term reliability and full rated output in industrial enclosures:

  • Airflow & Thermal Derating Management: Maintain unobstructed front-to-rear airflow across the internal variable-speed fans and derate output load linearly from 100% (3000 W) at +50 °C (+122 °F) to 50% (1500 W) at +60 °C (+140 °F).
  • Low-Line Input & Breaker Sizing: Account for linear power derating between 180 VAC (3000 W) and 90 VAC (2000 W), and select upstream slow-blow or D-curve circuit breakers rated to withstand the 110 A cold-start inrush current at 230 VAC.
  • Enable Link, Sense & Parallel Wiring Rules: Verify the factory-fitted enable jumper on CN2 (or wire an external inhibit switch between EN+ and EN-) prior to power-up, connect VS+/VS- for remote or local sense, and cap combined parallel load at 90% of total rated current (ensuring load exceeds 5% so all parallel units actively share).