Description
XP Power ECL15US15-T (also known as ECL15US15T) is an ultra-compact 15 W single-output AC-DC power supply from the ECL15 series, where the US15 nomenclature denotes a single-output 15.0 VDC rail and the -T suffix specifies an open-frame chassis-mount assembly with JST wafer connectors. Operating across a universal 85–264 VAC (120–370 VDC) input without requiring a safety earth connection (Class II construction), this fixed-frequency 70 kHz flyback converter delivers 1.00 A continuous current and up to 1.30 A peak load for less than 30 seconds at 80% typical efficiency. Tight ±1% initial set accuracy, ±0.5% maximum line regulation, 1% maximum load regulation, and under 0.3 W no-load power draw ensure clean, energy-compliant auxiliary power.
Measuring 78.7 × 31.7 × 20.0 mm max (3.10 × 1.25 × 0.78 in) and weighing just 35 g (0.07 lbs), the ECL15US15-T mounts via four 3.2 mm chassis holes and interfaces through industry-standard JST B2B-PH-K-S / B3B-PH-K-S style headers mating with JST PHR-3 (input) and PHR-4 (output) housings, alongside an onboard ±5% output voltage trim potentiometer. Comprehensive fault protection encompasses 115–140% overvoltage protection, 120–150% overload protection, and auto-recovering hiccup-mode short-circuit protection backed by an internal T2 A / 250 VAC input fuse. Rated for 3000 VAC input-to-output isolation and convection-cooled operation from -20 °C to +70 °C (-4 °F to +158 °F) up to 3000 m altitude, it carries full IEC/UL/EN 62368-1 safety approvals and EN 55032 Class B emissions compliance.
Key Features
- 15 W Continuous & 19.5 W Peak Output: Delivers 15.0 VDC at 1.00 A continuous and 1.30 A peak current for under 30 seconds (10% max duty cycle) with 80% efficiency.
- Ultra-Compact Open-Frame Chassis Footprint: Measures 78.7 × 31.7 × 20.0 mm max (3.10 × 1.25 × 0.78 in) at 35 g (0.07 lbs) with four 3.2 mm chassis mounting holes.
- Universal Input & Class II Isolation: Accepts 85–264 VAC (120–370 VDC) with 3000 VAC input-to-output isolation, Class II double-insulated construction (no earth ground required), and under 0.3 W no-load draw.
- Precision Voltage Regulation & Onboard Trim: Maintains ±1% initial set accuracy, ±0.5% line regulation, 1% load regulation, 120 mV pk-pk ripple, and ±5% output voltage adjustment via onboard trimmer.
- Plug-and-Play JST Connector Interface: Equipped with polarized PCB headers mating with JST PHR-3 (AC input) and JST PHR-4 (DC output) housings using SPH-002T-P0.5S crimp contacts.
- Comprehensive Fault & Fuse Protection: Integrates an internal T2 A / 250 VAC fuse, 115–140% overvoltage protection, 120–150% overload limiting, and auto-recovering hiccup-mode short-circuit protection.
- Global IEC/UL 62368-1 & Class B EMC: Certified to UL 62368-1, CSA C22.2 No. 62368-1, and EN/IEC 62368-1 while meeting EN 55032 Level B conducted and radiated emissions without external filtering.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | ECL15US15-T |
| Alternate Part Number | ECL15US15T |
| Product Series | ECL15 Series |
| Product Category | Open Frame PSUs |
| Component Type | Open-Frame Chassis-Mount AC-DC Power Supply |
| Circuit Topology | Isolated Fixed-Frequency Flyback (70 kHz) |
| Nominal Output Voltage | 15 VDC |
| Output Voltage Adjustment Range | 14.25 – 15.75 VDC (±5% via onboard trim potentiometer) |
| Rated Output Current | 1.00 A |
| Output Current Range | 0 – 1.00 A |
| Peak / Surge Output Current | 1.30 A (<30 s duration, max. 10% duty cycle, average power ≤ 15 W) |
| Rated Output Power | 15 W |
| Peak Output Power | 19.5 W (<30 s duration, max. 10% duty cycle) |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 120 mV pk-pk (measured at 20 MHz bandwidth) |
| Output Voltage Tolerance | ±1% (initial set accuracy) |
| Line Regulation | ±0.5% max. |
| Load Regulation | 1% max. (0 – 100% load) |
| Transient Recovery Time & Deviation | 4% max. deviation, recovery to within 1% in 500 µs (for 25% load step) |
| Setup Time | 3 s max. (start-up delay) |
| Rise Time | 14 ms max. |
| Hold-Up Time (at 115 VAC) | 16 ms typical (at full load) |
| AC Input Voltage Range | 85 – 264 VAC (Single-Phase) |
| DC Input Voltage Range | 120 – 370 VDC |
| Input Frequency Range | 47 – 63 Hz |
| Efficiency | 80% typical |
| AC Input Current (at 230 VAC) | 0.3 A rms max. |
| Inrush Current (Cold Start at 115 VAC) | 20 A (at 25 °C) |
| Inrush Current (Cold Start at 230 VAC) | 40 A (at 25 °C) |
| Power Factor Correction (PFC) | Compliant with EN 61000-3-2 Class A |
| No-Load Power Consumption | <0.3 W |
| Switching Frequency | 70 kHz typical |
| Mounting Style | Chassis Mount (Open Frame via 4 × Ø 3.2 mm / 0.12 in mounting holes) |
| Cooling Method | Free Air Convection |
| Overall Width (W) | 31.7 mm (1.25 in) |
| Overall Height (H) | 20.0 mm max. (0.78 in max.) |
| Overall Depth (D) | 78.7 mm (3.10 in) |
| Dimensional Tolerance | ±0.5 mm (±0.02 in) for 2-decimal dims; ±0.25 mm (±0.01 in) for 3-decimal dims |
| Mounting Hole Pitch | 71.1 × 24.1 mm (2.80 × 0.95 in) |
| Net Weight | 35 g (0.07 lbs) |
| Termination / Connector Style | JST Pin Headers (Mates with JST PHR-3 Input & JST PHR-4 Output; SPH-002T-P0.5S crimps) |
| Input Terminal Pinout | 3-Pin Header (Mates with JST PHR-3): Pin 1 = ACN, Pin 2 = No Pin, Pin 3 = ACL (Internal T2 A / 250 VAC fuse) |
| Output & Signal Terminal Pinout | 4-Pin Header (Mates with JST PHR-4): Outer Pins = -Vo and +Vo (Optional cable harness: XP Power ECL15 LOOM KIT) |
| Overload Protection (OLP) Threshold | 120% – 150% of rated output power |
| Overvoltage Protection (OVP) Threshold | 115% – 140% of nominal output voltage (17.25 – 21.0 VDC) |
| Short Circuit Protection (SCP) | Trip and restart (continuous auto-recovery hiccup mode) |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC (Reinforced / Double Insulation) |
| Earth Leakage Current | Class II Construction (No protective earth ground connection required) |
| Operating Ambient Temperature Range | -20 °C to +70 °C (-4 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% load (15 W) |
| High-Temperature Derating Rate | Linear derating at 2.5% / °C from 100% load (15 W) at +50 °C to 50% load (7.5 W) at +70 °C |
| Altitude Derating | Rated for operation up to 3000 m (9,842 ft) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 95% RH max. (non-condensing) |
| Temperature Coefficient | ±0.05% / °C |
| Vibration Resistance | 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins per axis |
| Safety Approvals (UL / North America) | UL 62368-1, CAN/CSA C22.2 No. 62368-1-14 |
| Safety Approvals (IEC / EN / TÜV) | IEC 60950-1:2005 Ed. 2, IEC 62368-1:2014, EN 62368-1:2014/A11:2017 |
| EMC Conducted & Radiated Emissions | EN 55032 Level B (Conducted & Radiated) |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A (Harmonics), EN 61000-3-3 (Voltage Flicker) |
| EMC Immunity Standards | EN 61000-4-2 Level 3 (ESD, Crit. A), EN 61000-4-3 10 V/m (Radiated, Crit. A), EN 61000-4-4 Level 3 (EFT/Burst, Crit. A), EN 61000-4-5 Class 3 (Surge, Crit. A), EN 61000-4-6 10 Vrms (Conducted, Crit. A), EN 61000-4-8 10 A/m (Magnetic Field, Crit. A), EN 61000-4-11 (Dips & Interruptions: 30%/10 ms Crit. A, 60%/100 ms Crit. B, 100%/5000 ms Crit. B) |
| MTBF (MIL-HDBK-217F) | >400,000 hours (at +25 °C ambient, Ground Benign) |
| Environmental Compliance | RoHS Compliant |
Industrial Applications & Compatible Systems
The XP Power ECL15US15-T delivers space-saving, Class II isolated 15 VDC bias power for embedded OEM equipment, instrumentation, and light industrial control enclosures.
- Industrial Sensors & Process Transmitters: Powers 15 VDC analog signal conditioners, ultrasonic level sensors, and 4–20 mA loop transmitter excitation rails with low 120 mV pk-pk ripple.
- Test, Measurement & Bench Instrumentation: Supplies regulated +15 VDC rails for precision op-amp front ends, data acquisition modules, and handheld diagnostic stations without requiring a chassis earth ground.
- Building Automation & Security Access Control: Provides under-0.3 W standby auxiliary power for smart building gateways, biometric card readers, and solenoid latch controllers.
- Embedded Kiosks, Vending & Retail Terminals: Fits inside tight 1U or shallow wall-mount enclosures where 31.7 mm width and 20.0 mm height clearance are critical.
Installation, Thermal Management & MRO Guidelines
Follow these mechanical, electrical, and thermal integration practices when installing the open-frame ECL15US15-T chassis module.
- Chassis Standoff & Creepage Clearance: Secure the PCB using all four 3.2 mm mounting holes on non-conductive or grounded metal standoffs at least 6 mm tall to maintain primary-to-secondary creepage and clearance distances below the solder side.
- Crimp Harness Assembly: Terminate input and output wiring using genuine JST PHR-3 and PHR-4 housings fitted with SPH-002T-P0.5S crimp contacts (or order the pre-wired XP Power ECL15 LOOM KIT) to prevent pin back-out under 2 g vibration.
- High-Temperature Linear Derating: Maintain unobstructed natural convection airflow around the open-frame assembly; above +50 °C (+122 °F), linearly derate output power at 2.5% per °C down to 7.5 W (0.50 A) at +70 °C (+158 °F).
- Peak Load & Breaker Coordination: Restrict transient surge currents up to 1.30 A (19.5 W) to bursts under 30 seconds at a 10% maximum duty cycle, and size upstream AC branch protection to accommodate 40 A cold-start inrush at 230 VAC.