ECL15US15-T XP Power 15W 15VDC Open Frame Power Supply

$33.43

XP Power ECL15US15-T (ECL15US15T) 15W 15VDC 1A open-frame chassis-mount AC-DC power supply, 85–264VAC input, Class II, 3000VAC isolation, UL/IEC 62368-1.

SKU: ECL15US15-T Category: Brand:

Description

XP Power ECL15US15-T (also known as ECL15US15T) is an ultra-compact 15 W single-output AC-DC power supply from the ECL15 series, where the US15 nomenclature denotes a single-output 15.0 VDC rail and the -T suffix specifies an open-frame chassis-mount assembly with JST wafer connectors. Operating across a universal 85–264 VAC (120–370 VDC) input without requiring a safety earth connection (Class II construction), this fixed-frequency 70 kHz flyback converter delivers 1.00 A continuous current and up to 1.30 A peak load for less than 30 seconds at 80% typical efficiency. Tight ±1% initial set accuracy, ±0.5% maximum line regulation, 1% maximum load regulation, and under 0.3 W no-load power draw ensure clean, energy-compliant auxiliary power.

Measuring 78.7 × 31.7 × 20.0 mm max (3.10 × 1.25 × 0.78 in) and weighing just 35 g (0.07 lbs), the ECL15US15-T mounts via four 3.2 mm chassis holes and interfaces through industry-standard JST B2B-PH-K-S / B3B-PH-K-S style headers mating with JST PHR-3 (input) and PHR-4 (output) housings, alongside an onboard ±5% output voltage trim potentiometer. Comprehensive fault protection encompasses 115–140% overvoltage protection, 120–150% overload protection, and auto-recovering hiccup-mode short-circuit protection backed by an internal T2 A / 250 VAC input fuse. Rated for 3000 VAC input-to-output isolation and convection-cooled operation from -20 °C to +70 °C (-4 °F to +158 °F) up to 3000 m altitude, it carries full IEC/UL/EN 62368-1 safety approvals and EN 55032 Class B emissions compliance.

Key Features

  • 15 W Continuous & 19.5 W Peak Output: Delivers 15.0 VDC at 1.00 A continuous and 1.30 A peak current for under 30 seconds (10% max duty cycle) with 80% efficiency.
  • Ultra-Compact Open-Frame Chassis Footprint: Measures 78.7 × 31.7 × 20.0 mm max (3.10 × 1.25 × 0.78 in) at 35 g (0.07 lbs) with four 3.2 mm chassis mounting holes.
  • Universal Input & Class II Isolation: Accepts 85–264 VAC (120–370 VDC) with 3000 VAC input-to-output isolation, Class II double-insulated construction (no earth ground required), and under 0.3 W no-load draw.
  • Precision Voltage Regulation & Onboard Trim: Maintains ±1% initial set accuracy, ±0.5% line regulation, 1% load regulation, 120 mV pk-pk ripple, and ±5% output voltage adjustment via onboard trimmer.
  • Plug-and-Play JST Connector Interface: Equipped with polarized PCB headers mating with JST PHR-3 (AC input) and JST PHR-4 (DC output) housings using SPH-002T-P0.5S crimp contacts.
  • Comprehensive Fault & Fuse Protection: Integrates an internal T2 A / 250 VAC fuse, 115–140% overvoltage protection, 120–150% overload limiting, and auto-recovering hiccup-mode short-circuit protection.
  • Global IEC/UL 62368-1 & Class B EMC: Certified to UL 62368-1, CSA C22.2 No. 62368-1, and EN/IEC 62368-1 while meeting EN 55032 Level B conducted and radiated emissions without external filtering.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) ECL15US15-T
Alternate Part Number ECL15US15T
Product Series ECL15 Series
Product Category Open Frame PSUs
Component Type Open-Frame Chassis-Mount AC-DC Power Supply
Circuit Topology Isolated Fixed-Frequency Flyback (70 kHz)
Nominal Output Voltage 15 VDC
Output Voltage Adjustment Range 14.25 – 15.75 VDC (±5% via onboard trim potentiometer)
Rated Output Current 1.00 A
Output Current Range 0 – 1.00 A
Peak / Surge Output Current 1.30 A (<30 s duration, max. 10% duty cycle, average power ≤ 15 W)
Rated Output Power 15 W
Peak Output Power 19.5 W (<30 s duration, max. 10% duty cycle)
Number of Outputs 1 (Single Output)
Output Ripple & Noise (Max.) 120 mV pk-pk (measured at 20 MHz bandwidth)
Output Voltage Tolerance ±1% (initial set accuracy)
Line Regulation ±0.5% max.
Load Regulation 1% max. (0 – 100% load)
Transient Recovery Time & Deviation 4% max. deviation, recovery to within 1% in 500 µs (for 25% load step)
Setup Time 3 s max. (start-up delay)
Rise Time 14 ms max.
Hold-Up Time (at 115 VAC) 16 ms typical (at full load)
AC Input Voltage Range 85 – 264 VAC (Single-Phase)
DC Input Voltage Range 120 – 370 VDC
Input Frequency Range 47 – 63 Hz
Efficiency 80% typical
AC Input Current (at 230 VAC) 0.3 A rms max.
Inrush Current (Cold Start at 115 VAC) 20 A (at 25 °C)
Inrush Current (Cold Start at 230 VAC) 40 A (at 25 °C)
Power Factor Correction (PFC) Compliant with EN 61000-3-2 Class A
No-Load Power Consumption <0.3 W
Switching Frequency 70 kHz typical
Mounting Style Chassis Mount (Open Frame via 4 × Ø 3.2 mm / 0.12 in mounting holes)
Cooling Method Free Air Convection
Overall Width (W) 31.7 mm (1.25 in)
Overall Height (H) 20.0 mm max. (0.78 in max.)
Overall Depth (D) 78.7 mm (3.10 in)
Dimensional Tolerance ±0.5 mm (±0.02 in) for 2-decimal dims; ±0.25 mm (±0.01 in) for 3-decimal dims
Mounting Hole Pitch 71.1 × 24.1 mm (2.80 × 0.95 in)
Net Weight 35 g (0.07 lbs)
Termination / Connector Style JST Pin Headers (Mates with JST PHR-3 Input & JST PHR-4 Output; SPH-002T-P0.5S crimps)
Input Terminal Pinout 3-Pin Header (Mates with JST PHR-3): Pin 1 = ACN, Pin 2 = No Pin, Pin 3 = ACL (Internal T2 A / 250 VAC fuse)
Output & Signal Terminal Pinout 4-Pin Header (Mates with JST PHR-4): Outer Pins = -Vo and +Vo (Optional cable harness: XP Power ECL15 LOOM KIT)
Overload Protection (OLP) Threshold 120% – 150% of rated output power
Overvoltage Protection (OVP) Threshold 115% – 140% of nominal output voltage (17.25 – 21.0 VDC)
Short Circuit Protection (SCP) Trip and restart (continuous auto-recovery hiccup mode)
Withstand Isolation Voltage (I/P to O/P) 3000 VAC (Reinforced / Double Insulation)
Earth Leakage Current Class II Construction (No protective earth ground connection required)
Operating Ambient Temperature Range -20 °C to +70 °C (-4 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 100% load (15 W)
High-Temperature Derating Rate Linear derating at 2.5% / °C from 100% load (15 W) at +50 °C to 50% load (7.5 W) at +70 °C
Altitude Derating Rated for operation up to 3000 m (9,842 ft)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 95% RH max. (non-condensing)
Temperature Coefficient ±0.05% / °C
Vibration Resistance 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins per axis
Safety Approvals (UL / North America) UL 62368-1, CAN/CSA C22.2 No. 62368-1-14
Safety Approvals (IEC / EN / TÜV) IEC 60950-1:2005 Ed. 2, IEC 62368-1:2014, EN 62368-1:2014/A11:2017
EMC Conducted & Radiated Emissions EN 55032 Level B (Conducted & Radiated)
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A (Harmonics), EN 61000-3-3 (Voltage Flicker)
EMC Immunity Standards EN 61000-4-2 Level 3 (ESD, Crit. A), EN 61000-4-3 10 V/m (Radiated, Crit. A), EN 61000-4-4 Level 3 (EFT/Burst, Crit. A), EN 61000-4-5 Class 3 (Surge, Crit. A), EN 61000-4-6 10 Vrms (Conducted, Crit. A), EN 61000-4-8 10 A/m (Magnetic Field, Crit. A), EN 61000-4-11 (Dips & Interruptions: 30%/10 ms Crit. A, 60%/100 ms Crit. B, 100%/5000 ms Crit. B)
MTBF (MIL-HDBK-217F) >400,000 hours (at +25 °C ambient, Ground Benign)
Environmental Compliance RoHS Compliant

Industrial Applications & Compatible Systems

The XP Power ECL15US15-T delivers space-saving, Class II isolated 15 VDC bias power for embedded OEM equipment, instrumentation, and light industrial control enclosures.

  • Industrial Sensors & Process Transmitters: Powers 15 VDC analog signal conditioners, ultrasonic level sensors, and 4–20 mA loop transmitter excitation rails with low 120 mV pk-pk ripple.
  • Test, Measurement & Bench Instrumentation: Supplies regulated +15 VDC rails for precision op-amp front ends, data acquisition modules, and handheld diagnostic stations without requiring a chassis earth ground.
  • Building Automation & Security Access Control: Provides under-0.3 W standby auxiliary power for smart building gateways, biometric card readers, and solenoid latch controllers.
  • Embedded Kiosks, Vending & Retail Terminals: Fits inside tight 1U or shallow wall-mount enclosures where 31.7 mm width and 20.0 mm height clearance are critical.

Installation, Thermal Management & MRO Guidelines

Follow these mechanical, electrical, and thermal integration practices when installing the open-frame ECL15US15-T chassis module.

  • Chassis Standoff & Creepage Clearance: Secure the PCB using all four 3.2 mm mounting holes on non-conductive or grounded metal standoffs at least 6 mm tall to maintain primary-to-secondary creepage and clearance distances below the solder side.
  • Crimp Harness Assembly: Terminate input and output wiring using genuine JST PHR-3 and PHR-4 housings fitted with SPH-002T-P0.5S crimp contacts (or order the pre-wired XP Power ECL15 LOOM KIT) to prevent pin back-out under 2 g vibration.
  • High-Temperature Linear Derating: Maintain unobstructed natural convection airflow around the open-frame assembly; above +50 °C (+122 °F), linearly derate output power at 2.5% per °C down to 7.5 W (0.50 A) at +70 °C (+158 °F).
  • Peak Load & Breaker Coordination: Restrict transient surge currents up to 1.30 A (19.5 W) to bursts under 30 seconds at a 10% maximum duty cycle, and size upstream AC branch protection to accommodate 40 A cold-start inrush at 230 VAC.