PCM50US3V3 XP Power 40W 3.3VDC Medical Power Adapter

$107.18

XP Power PCM50US3V3 40W 3.3VDC 8A medical desktop power adapter, 90-264VAC input, featuring 4000VAC isolation, dual line/neutral fusing, and EN60601-1 safety.

SKU: PCM50US3V3 Category: Brand:

Description

XP Power PCM50US3V3 is a medical-grade external desktop AC-DC power supply from the PCM50 series, where the nomenclature denotes a 50W-class platform (PCM50), universal AC input (U), single-output architecture (S), and a regulated 3.3 VDC output rail (3V3). Engineered with a high-reliability switch-mode topology operating at 64 kHz (PWM) and 70 kHz (PFC), this single-output unit delivers up to 40 W continuous output power and 8.00 A rated current across a universal 90 to 264 VAC (47–63 Hz) input range. It operates with 80% typical efficiency at 230 VAC full load and requires zero minimum load (0 A) for stable single-output regulation. Output quality is tightly controlled within a ±5% total regulation band (combining initial set tolerance, ±1% max. line regulation, and ±5% max. load regulation), while high-frequency ripple and noise is limited to 2% pk-pk max. (66 mVp-p) across a 20 MHz bandwidth.

Housed in an impact-resistant desktop enclosure measuring 76.0 mm (2.99 in) W × 43.0 mm (1.69 in) H × 146.0 mm (5.75 in) D with a top-mounted Power LED status indicator, the adapter connects to mains power via a standard IEC 320-C14 3-prong AC inlet and delivers DC power through a 1.22 m (48.0 in) output cable terminated with a 5-pin 180° DIN plug (Pins 1, 2, 4: Common; Pins 3, 5: +3.3 V Output; Shell: Earth Ground). Built for sensitive clinical environments, it integrates dual fuses on both Line and Neutral conductors, 112%–132% overvoltage protection (OVP), and 110%–200% auto-recovering overcurrent protection (OCP). The barrier structure provides 4000 VAC input-to-output reinforced medical isolation, 1500 VAC input-to-ground isolation, and low earth leakage current of 180 µA max. at 132 VAC / 60 Hz (300 µA max. at 264 VAC / 50 Hz). Certified to EN 60601-1 and EN 55032 Level B EMI standards, the unit delivers full 40 W power from 0 °C to +50 °C (+32 °F to +122 °F) and operates up to +70 °C (+158 °F) with linear derating to 50% load.

Key Features

  • High-Current 3.3 VDC Logic Output: Supplies up to 8.00 A continuous current and 40 W rated output power with zero minimum load requirement (0 A) and a tight ±5% total regulation window.
  • 4000 VAC Medical-Grade Galvanic Isolation: Provides 4000 VAC input-to-output, 1500 VAC input-to-ground, and 500 VAC output-to-ground withstand barriers alongside dual Line and Neutral fusing for EN 60601-1 patient and operator protection.
  • Low Earth Leakage Current Architecture: Restricts earth leakage current to 180 µA max. at 132 VAC / 60 Hz and 300 µA max. at 264 VAC / 50 Hz for medical diagnostic and laboratory instruments.
  • Universal 90–264 VAC Input & Hold-Up Resilience: Operates across global 90–264 VAC (47–63 Hz) mains with 80% typical efficiency at 230 VAC and a minimum 10 ms hold-up time at low line.
  • Fast Transient Recovery & Low Ripple: Limits output voltage deviation to 5% max. with a 500 µs recovery time under a 50% step load change while holding ripple and noise within 2% pk-pk (20 MHz BW).
  • Comprehensive OVP & Auto-Recovery OCP: Safeguards low-voltage 3.3 V digital circuits with 112%–132% overvoltage protection and 110%–200% overcurrent protection featuring automatic recovery upon fault removal.
  • 5-Pin 180° DIN Plug & IEC 320 Inlet: Features a standard IEC 320-C14 AC receptacle and a 48.0 in (1.22 m) DC cord wired with dual parallel output pins (3 & 5) and triple return pins (1, 2 & 4).
  • Wide 0 °C to +70 °C Thermal Envelope & EN 55032 Class B: Sustains 100% load up to +50 °C ambient (derating linearly to 50% at +70 °C) and meets EN 55032 Level B emissions and IEC 61000-4 Level 3 immunity.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) PCM50US3V3
Product Series PCM50 Series
Product Category Medical Power Adapters
Component Type External Desktop Medical AC-DC Power Adapter
Circuit Topology Switched-Mode Power Supply (SMPS), Regulated Single Output with Dual Line & Neutral Fusing
Nominal Output Voltage 3.3 VDC
Rated Output Current 8.00 A
Output Current Range 0 A to 8.00 A (No minimum load required for single-output models)
Rated Output Power 40 W
Number of Outputs 1 Output (Single Output)
Output Ripple & Noise (Max.) 2% pk-pk max. (66 mVp-p max. at 3.3 VDC), measured at 20 MHz bandwidth
Output Voltage Tolerance ±5% max. total regulation (includes initial set tolerance, line regulation, and load regulation)
Line Regulation ±1% max. at full load
Load Regulation ±5% max.
Transient Recovery Time & Deviation 5% max. deviation, 500 µs recovery time for a 50% load step change
Setup Time 2 s max. (Start-Up Delay)
Hold-Up Time (at 115 VAC) 10 ms min. at low line
AC Input Voltage Range 90 VAC to 264 VAC (Universal Input)
Input Frequency Range 47 Hz to 63 Hz
Efficiency (at 230 VAC) 80% typical (at 230 VAC, 100% full load)
AC Input Current (at 115 VAC) 1.35 A max.
Inrush Current (Cold Start at 115 VAC) 30 A max. at 25 °C cold start
Inrush Current (Cold Start at 230 VAC) 60 A max. at 25 °C cold start
Power Factor (PF at 230 VAC) 0.55 typical
Switching Frequency 64 kHz typical (PWM), 70 kHz typical (PFC)
Mounting Style Desktop / External Inline Enclosure
Cooling Method Free Air Natural Convection
Overall Width (W) 76.0 mm (2.99 in)
Overall Height (H) 43.0 mm (1.69 in)
Overall Depth (D) 146.0 mm (5.75 in)
Dimensional Tolerance ±1.0 mm (±0.04 in) max.
Net Weight 400 g to 550 g (0.88 lb to 1.21 lb) approx.
Termination / Connector Style Input: IEC 320-C14 3-Pin AC Inlet; Output: 5-Pin DIN 180° Male Plug on captive DC cord (mates with standard 5-pin DIN 180° socket)
Input Terminal Pinout IEC 320 Inlet: Line (L), Neutral (N), Earth Ground (E) — Both Line and Neutral internally fused
Output & Signal Terminal Pinout 5-Pin DIN Plug: Pin 1 = Common, Pin 2 = Common, Pin 3 = +3.3V Output, Pin 4 = Common, Pin 5 = +3.3V Output, Connector Shell = Earth Ground (connected to AC input Earth pin)
Status Indicator Top-panel AC Power-On LED Indicator
Lead Wire Length 1220 mm (48.0 in / 1.22 m) approx. output DC cable
Overload Protection (OLP) Threshold 110% to 200% of rated output current
Overload Protection (OLP) Mode Auto-recovery upon fault removal
Overvoltage Protection (OVP) Threshold 112% to 132% of nominal output voltage
Short Circuit Protection (SCP) Continuous overcurrent protection with automatic recovery
Withstand Isolation Voltage (I/P to O/P) 4000 VAC
Withstand Isolation Voltage (I/P to FG / Case) 1500 VAC
Withstand Isolation Voltage (O/P to FG / Case) 500 VAC
Earth Leakage Current 180 µA max. at 132 VAC / 60 Hz; 300 µA max. at 264 VAC / 50 Hz
Operating Ambient Temperature Range 0 °C to +70 °C (+32 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 100% load (40 W / 8.00 A)
High-Temperature Derating Rate Derate linearly at 2.5% per °C (1.0 W / °C) from 100% load at +50 °C (+122 °F) to 50% load (20 W / 4.00 A) at +70 °C (+158 °F)
Storage Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Coefficient ±0.05% / °C
Safety Approvals (IEC / EN / TÜV) EN 60601-1 Medical Electrical Equipment Safety
Safety Approvals (Regional / Global) CE (Meets all applicable directives), UKCA (Meets all applicable legislation)
EMC Conducted & Radiated Emissions EN 55032 Level B (Conducted & Radiated Emissions)
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker)
EMC Immunity Standards IEC 61000-4-2 Level 3 (ESD, Perf Criteria A), IEC 61000-4-3 Level 3 (Radiated 10 V/m, Perf Criteria A), IEC 61000-4-4 Level 3 (EFT/Burst, Perf Criteria A), IEC 61000-4-5 Level 3 (Surge, Perf Criteria A), IEC 61000-4-6 Level 3 (Conducted 10 V/m, Perf Criteria A), IEC 61000-4-8 (Magnetic Fields 10 A/m, Perf Criteria A), IEC 61000-4-11 (Voltage Dips & Interruptions: 30% 500 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B)
MTBF (MIL-HDBK-217F) 100,000 Hours (100 kHrs) min. at full load and +25 °C (+77 °F) ambient

Industrial Applications & Compatible Systems

The XP Power PCM50US3V3 is engineered for medical, clinical laboratory, and low-voltage digital instrumentation requiring a 4000 VAC isolated, high-current 3.3 VDC external power source:

  • Point-of-Care Medical & Diagnostic Equipment: Powers bedside diagnostic analyzers, patient monitoring consoles, portable ultrasound docks, and ophthalmic instruments requiring EN 60601-1 compliance, dual Line/Neutral fusing, and low earth leakage current (180 µA max. at 132 VAC).
  • Clinical Laboratory & In-Vitro Diagnostic (IVD) Systems: Provides regulated 3.3 VDC up to 8.00 A for benchtop hematology analyzers, PCR thermal cyclers, spectrophotometer logic boards, and automated fluid handling workstations.
  • Dental & Aesthetic Treatment Consoles: Supplies isolated low-voltage DC power to tabletop dental imaging processors, optical scanners, and laser control interfaces subject to strict EN 55032 Class B EMI limits.
  • FPGA, DSP & Embedded Single-Board Computer Enclosures: Feeds high-current 3.3 V digital logic rails directly via parallel-pinned 5-pin DIN connections without requiring internal AC-DC conversion stages or minimum load resistors.

Installation, Thermal Management & MRO Guidelines

To ensure reliable long-term operation and maintain medical safety compliance during OEM integration or MRO replacement, observe the following engineering guidelines:

  • Parallel 5-Pin DIN Current Sharing & Mating Socket Wiring: Because the PCM50US3V3 delivers up to 8.00 A at 3.3 VDC, both output pins (Pins 3 and 5) and all three return pins (Pins 1, 2, and 4) on the mating 180° 5-pin DIN socket must be wired in parallel on the host PCB to minimize contact resistance and prevent voltage drop or pin overheating.
  • Chassis Grounding & Output Shell Bond: Note that the metallic shell of the 5-pin DIN output plug is internally bonded to the IEC 320 AC input Earth pin, while the DC output faces a 500 VAC isolation barrier to ground; account for this earth bond when designing grounding schemes for sensitive analog front-ends.
  • Thermal Convection & +50 °C Derating Curve: Provide unobstructed airflow around the desktop housing so heat can dissipate naturally; the unit sustains full 40 W (8.00 A) output up to +50 °C (+122 °F) ambient and must be derated linearly at 1.0 W/°C (0.20 A/°C) down to 20 W (4.00 A) at +70 °C (+158 °F).
  • Hospital-Grade Mains Cord & Inrush Sizing: Pair the IEC 320-C14 inlet with an appropriately rated hospital-grade detachable mains cord for clinical environments, and size upstream branch circuit breakers to accommodate the 30 A (115 VAC) / 60 A (230 VAC) cold-start inrush current.