Description
TDK-Lambda DTM70CN120C8 is a 70W Class II external desktop AC-DC power supply engineered for medical, home healthcare, and industrial instrumentation applications. Within the DTM70 nomenclature, DTM70CN designates the 70W external adapter platform, 120 specifies the regulated 12VDC nominal output at 5.8A maximum continuous current, and the C8 suffix identifies the two-pin ungrounded IEC 320-C8 Class II AC inlet. Operating across an 80 to 264VAC input range (safety certified for 90 to 264VAC, 47 to 63Hz) at a 65kHz switching frequency, the converter achieves 89% efficiency at 230VAC, meets DoE Level VI and ErP energy standards with less than 150mW no-load draw, and maintains ±2% voltage accuracy with 120mV pk-pk maximum ripple and noise.
Comprehensive fault protection includes auto-recovery overcurrent protection (130% to 150%), auto-recovery overvoltage clamping at 13.5V, brownout shutdown at 60 to 70VAC, and continuous hiccup-mode short-circuit protection. Double-insulated Class II construction delivers 4,400VAC (2x MOPP) input-to-output galvanic isolation with under 90µA touch current, supporting Type B and Type BF patient-connected equipment without a protective earth connection. Convection-cooled inside a compact IP21 enclosure measuring 120 × 52 × 31 mm (4.72 × 2.05 × 1.22 in), the adapter operates from -30°C to +40°C at 100% load (linearly derated to 50% load up to +60°C) and carries IEC/UL/CSA/EN 60601-1, IEC 60601-1-11, and IEC/EN 62368-1 approvals.
Key Features
- Regulated 12VDC / 5.8A Medical Output: Delivers 70W continuous power with ±2% voltage accuracy, 1% line regulation, 120mV pk-pk ripple and noise, and 5,800µF maximum capacitive load capability.
- Class II Double-Insulated IEC 320-C8 Inlet: Eliminates protective earth requirements while maintaining 4,400VAC (2x MOPP) input-to-output isolation and below 90µA touch current for Type B and BF medical devices.
- DoE Level VI & ErP Energy Compliance: Achieves 89% typical efficiency at 230VAC and consumes less than 150mW (0.15W) under no-load standby conditions across universal 90–264VAC mains.
- Comprehensive Auto-Recovery Fault Protection: Integrates 130%–150% overcurrent limiting, 13.5V overvoltage protection, 60–70VAC undervoltage lockout, and continuous hiccup-mode short-circuit protection.
- Wide -30°C to +60°C Thermal Envelope: Supports cold-start operation down to -30°C and full 70W convection-cooled output up to +40°C, derating linearly to 35W at +60°C up to 5,000m altitude.
- Locking 4-Pin Kycon KPPx-4P DC Plug: Equipped with a 1,220mm (48 in) 16AWG output cable and mechanical snap-lock connector to prevent accidental disconnection in clinical or portable environments.
- Global Medical & ICT Safety Approvals: Certified to IEC/UL/CSA/EN 60601-1 and IEC 60601-1-11 home healthcare standards, plus IEC/BS/EN 62368-1, EN 55011/55032 Class B, and IEC 60601-1-2 Ed4 EMC.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | DTM70CN120C8 |
| Product Series | DTM70 / DTM70-C8 Series |
| Product Category | Medical Power Adapters |
| Component Type | External Desktop AC-DC Medical & ICT Power Supply |
| Insulation Protection Class | Class II (Double Insulated, Ungrounded) |
| Nominal Output Voltage | 12 VDC |
| Output Voltage Adjustment | Fixed (Non-Adjustable) |
| Voltage Setpoint Accuracy | ±2% (at 115/230 VAC, 60% Load, 25 °C) |
| Rated Output Current | 5.8 A |
| Output Current Range | 0 to 5.8 A (No Minimum Load Required) |
| Rated Output Power | 70 W |
| Ripple & Noise (20 MHz BW) | 120 mV pk-pk max. (with 100 nF Ceramic + 10 µF Electrolytic Capacitors) |
| Line Regulation | ±1% |
| Maximum Capacitive Load | 5,800 µF |
| Hold-Up Time (at 115 VAC) | 8 ms min. / 10 ms typ. |
| Parallel Operation | Not Supported |
| Operating AC Input Voltage Range | 80 to 264 VAC (Safety Certified for 90 to 264 VAC) |
| Nominal Input Voltage Range | 100 to 240 VAC |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency (at 230 VAC) | 89% |
| AC Input Current (at 115 VAC) | 1.5 A max. |
| AC Input Current (at 230 VAC) | 0.75 A max. |
| Inrush Current (Cold Start at 240 VAC) | < 100 A (at 25 °C Ambient) |
| Power Factor (at 115 VAC) | 0.54 |
| Power Factor (at 230 VAC) | 0.46 |
| No-Load Power Consumption | < 150 mW (< 0.15 W, DoE Level VI & ErP Compliant) |
| Switching Frequency | 65 kHz (at Full Load) |
| Overcurrent Protection (OCP) Threshold | 130% to 150% of Rated Output Current |
| Overcurrent Protection (OCP) Mode | Auto-Recovery |
| Overvoltage Protection (OVP) Threshold | 13.5 VDC |
| Overvoltage Protection (OVP) Mode | Auto-Recovery |
| Short-Circuit Protection (SCP) | Continuous Hiccup Mode (Auto-Recovery) |
| Low Input Voltage Protection (Brownout) | 60 to 70 VAC |
| Withstand Isolation Voltage (I/P to O/P) | 4,400 VAC (1 Minute, 2x MOPP Medical Isolation) |
| Isolation Resistance | 20 MΩ min. |
| Touch Current | < 90 µA (Suitable for Type B & BF Equipment) |
| Overvoltage Category | Category II |
| Pollution Degree | PD2 |
| Operating Ambient Temperature | -30 °C to +60 °C (-22 °F to +140 °F) |
| Full-Load Operating Temp Limit | +40 °C (+104 °F) |
| High-Temperature Derating Rate | Linearly derated from 100% load at +40 °C to 50% load (35 W) at +60 °C (2.5% / °C) |
| Low-Line Input Derating | Linearly derated from 100% load at 90 VAC to 80% load (56 W) at 80 VAC |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 93% RH max. (Non-Condensing) |
| Maximum Operating Altitude | 5,000 m (16,404 ft) |
| MTBF (MIL-HDBK-217F) | 500,000 Hours min. (Full Load, Ground Benign at 25 °C) |
| Medical Safety Certifications | IEC/UL/CSA/EN 60601-1 (2x MOPP), IEC 60601-1-11 (Home Healthcare) |
| ICT & Industrial Safety Compliance | IEC/BS/EN 62368-1, CE Mark, UKCA Mark |
| EMC Conducted & Radiated Emissions | EN 55011 Class B, EN 55032 Class B, FCC 47 Part 18 |
| EMC Harmonic Current Emissions | IEC/EN 61000-3-2 Class A |
| EMC Voltage Fluctuations & Flicker | IEC/EN 61000-3-3 |
| EMC Immunity Standards | IEC 60601-1-2 (4th Edition), IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4 |
| Status Indicator | Green LED (DC Output Active) |
| AC Input Inlet Connector | IEC 320-C8 (2-Pin Ungrounded Class II; AC Line Cord Sold Separately) |
| DC Output Connector | Kycon KPPx-4P Locking 4-Pin Power Plug (or Equivalent) |
| Output Connector Pinout | Pin 1 & Pin 2: -Vout (Return) | Pin 3 & Pin 4: +Vout (+12 VDC) |
| DC Output Cable Length & Gauge | 1,220 mm (48.03 in), 16 AWG |
| Cooling Method | Natural Free-Air Convection |
| Ingress Protection Rating | IP21 |
| Overall Length (L) | 120 mm (4.72 in) |
| Overall Width (W) | 52 mm (2.05 in) |
| Overall Height (H) | 31 mm (1.22 in) |
| Overall Dimensions (L × W × H) | 120 × 52 × 31 mm (4.72 × 2.05 × 1.22 in) |
| Net Weight | 300 g (0.66 lbs / 10.58 oz) |
| Manufacturer Warranty | 3 Years |
Industrial Applications & Compatible Systems
TDK-Lambda DTM70CN120C8 is engineered for clinical, home-healthcare, and precision industrial systems requiring double-insulated 2x MOPP isolation and a secure locking 12VDC rail:
- Home Healthcare & Portable Medical Devices: Certified to IEC 60601-1-11 and Class II ungrounded operation, making it ideal for patient monitors, CPAP/respiratory therapy units, infusion pumps, and portable diagnostic consoles used in residences without reliable earth grounds.
- Clinical & Dental Point-of-Care Equipment: Low touch current (<90µA) and 4,400VAC (2x MOPP) isolation support Type B and Type BF applied-part instrumentation, ultrasound peripherals, and mobile examination carts.
- Laboratory, Analytical & Test Instrumentation: EN 55011/55032 Class B low-EMI performance and 120mV pk-pk ripple protect sensitive benchtop analyzers, optical sensors, and portable calibration meters.
- Industrial Human-Machine Interfaces (HMI) & Edge Gateways: Wide -30°C to +60°C operating range and IEC/EN 62368-1 compliance power ruggedized panel PCs, barcode terminals, and industrial IoT gateways.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: Pair the IEC 320-C8 inlet with a regionally approved 2-conductor ungrounded AC line cord (sold separately) and verify that the mating chassis receptacle accepts a 4-pin Kycon KPPX-4P locking plug wired to Pins 1/2 (-Vout) and Pins 3/4 (+12VDC). Maintain unobstructed free-air convection around the 120 × 52 × 31 mm enclosure and never enclose the adapter inside unventilated pockets; above +40°C ambient, derate continuous load linearly by 2.5%/°C down to 35W (2.9A) at +60°C, and derate by 20% if operating between 80VAC and 90VAC. Ensure total downstream bulk capacitance does not exceed 5,800µF to prevent overcurrent hiccup tripping during cold startup.