HDL3000PS12 XP Power 2400W 12VDC Chassis Power Supply

$1,182.58

XP Power HDL3000PS12 2400W 12VDC 200A programmable chassis AC-DC power supply, 90-264VAC input, 0-105% V/I control, I2C interface, active current share & UL62368-1.

SKU: HDL3000PS12 Category: Brand:

Description

XP Power HDL3000PS12 is a high-density, fan-cooled 2400W programmable AC-DC chassis power supply from the HDL3000 series, where the PS12 suffix designates a single 12.0 VDC nominal output rated at 200.0 A (2.4 kW) under high-line input (180–264 VAC) and 166.6 A (1.6 kW) under low-line input (90–180 VAC). Engineered around an active power factor corrected (PFC) front end operating at 65 kHz paired with a variable-frequency 40–200 kHz PWM power stage, it achieves 88% full-load efficiency at 230 VAC and maintains peak-to-peak ripple and noise within 150 mV. Both output voltage and output current are continuously programmable across 0% to 105% of nominal rating via an external 0–5 VDC analog voltage, 0–5 kΩ resistance, or I²C digital bus, alongside a ±5% mechanical trim potentiometer and active parallel current sharing for up to five units.

Housed in an enclosed industrial chassis measuring 316.5 mm × 170.0 mm × 63.5 mm (12.46 in × 6.69 in × 2.50 in) with an intelligent load- and temperature-controlled cooling fan, the unit features M4 screw AC mains terminals, heavy-duty M8 output studs, and a 24-pin JST CN2 control header providing remote on/off, Power OK, remote sense (0.5 V compensation), and a selectable 5 VDC / 0.5 A or 9 VDC / 0.3 A auxiliary standby rail. Comprehensive protection includes constant-current overload limiting at 105%, tracking overvoltage shutdown (latching AC reset), auto-recovering short-circuit protection, and dual-heatsink overtemperature shutdown, backed by 3000 VAC input-to-output galvanic isolation. The supply operates across -20 °C to +60 °C (-4 °F to +140 °F) with full rated output up to +50 °C (+122 °F) and holds CB, UL, TÜV, CE, and UKCA approvals to IEC/EN/UL 62368-1.

Key Features

  • High-Current 12 VDC Programmable Output: Delivers 200.0 A (2400 W) at high-line AC input and 166.6 A (1600 W) at low-line input with 0–105% output voltage and current programmability.
  • Triple Analog & Digital Control Interfaces: Supports continuous 0–105% voltage and current programming via 0–5 VDC external voltage, 0–5 kΩ external resistor, or onboard I²C digital communication bus.
  • Parallel Active Current Sharing & ORing: Built-in internal ORing diode and active current-share bus allow up to five units to operate in parallel within 5% load-sharing accuracy for scalable power.
  • Full-Featured Auxiliary & Supervisory Signals: Includes an always-on 5 VDC / 0.5 A (or user-selectable 9 VDC / 0.3 A) standby output, remote enable/inhibit, open-drain Power OK, and bicolor status LED.
  • Comprehensive Fault & Thermal Protections: Integrates 105% constant-current overload protection, tracking overvoltage protection (AC recycle reset), auto-recovering short-circuit and overtemperature protection, plus 3000 VAC input-to-output isolation.
  • Compact High-Density Chassis Construction: Achieves 36.5 W/cm³ (598.1 W/in³) power density in a 316.5 × 170.0 × 63.5 mm footprint with variable-speed fan cooling and M8 high-current output studs.
  • Global ITE Safety & EMC Compliance: Certified to IEC 62368-1, UL 62368-1, CAN/CSA C22.2 No. 62368-1, EN 62368-1, CE, and UKCA with EN 55032 Class A conducted and radiated emissions.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) HDL3000PS12
Product Series HDL3000 Series
Product Category Chassis Power Supplies
Component Type Programmable Enclosed AC-DC Power Supply
Circuit Topology Active PFC + Variable-Frequency PWM Switching
Nominal Output Voltage 12.0 VDC
Output Voltage Adjustment Range ±5% (via onboard trim potentiometer); 0% to 105% (via external voltage, resistance, or I²C programming)
Rated Output Current 200.0 A (High Line: 180–264 VAC); 166.6 A (Low Line: 90–180 VAC)
Output Current Range 0 to 200.0 A (Programmable 0% to 105% of rated output)
Rated Output Power 2400 W (2.4 kW at High Line: 180–264 VAC); 1600 W (1.6 kW at Low Line: 90–180 VAC)
Number of Outputs 1 Main Output + 1 Auxiliary Standby Output (5 VDC / 0.5 A or user-selectable 9 VDC / 0.3 A)
Output Ripple & Noise (Max.) 150 mV pk-pk (20 MHz bandwidth, 300 mm twisted pair with 0.1 µF ceramic & 47 µF electrolytic capacitors at +25 °C)
Output Voltage Tolerance ±2% of rated output voltage (includes setup, line, and load regulation)
Line Regulation ±1%
Load Regulation ±1% (Main V1 output); ±3% (Auxiliary Standby output, 0–100% load)
Transient Recovery Time & Deviation <1% voltage deviation for a 25% step load change
Setup Time 1000 ms (1 s start-up delay)
Rise Time 120 ms (at full load)
Hold-Up Time (at 230 VAC) 10 ms min. / 11 ms typ. (at full load)
AC Input Voltage Range 90 to 264 VAC (Single-Phase; see input derating curve below 180 VAC)
Input Frequency Range 47 to 63 Hz
Efficiency (at 230 VAC) 88% (at full load)
AC Input Current (at 115 VAC) 19.7 A (at 2 kW series reference)
AC Input Current (at 230 VAC) 15.0 A (at 3 kW series reference)
Inrush Current (Cold Start at 115 VAC) 43 A
Inrush Current (Cold Start at 230 VAC) 110 A
Power Factor (PF at 115 VAC) 0.98 (at full load)
Power Factor (PF at 230 VAC) 0.95 (at full load)
Power Factor Correction (PFC) Active PFC (EN 61000-3-2 Class A compliant)
Switching Frequency 65 kHz (PFC stage); 40 to 200 kHz variable (PWM stage)
Mounting Style Chassis Mount (Bottom 4× M4 and Side 8× M4 mounting holes, max penetration 3.0 mm / 0.12 in)
Cooling Method Forced Air Cooling (Internal intelligent speed-controlled fan)
Overall Width (W) 170.0 mm (6.69 in)
Overall Height (H) 63.5 mm (2.50 in)
Overall Depth (D) 316.5 mm (12.46 in, including connectors)
Mounting Hole Pitch Bottom: 208.0 mm × 78.0 mm (8.19 in × 3.07 in); Side: 237.0 mm × 35.0 mm (9.33 in × 1.38 in)
Net Weight 3.6 kg (7.94 lbs)
Termination / Connector Style AC Input: 3-Pin M4 Screw Terminal Block (11.0 mm pitch); DC Output: M8 Slotted/Posidrive Busbar Studs; Signals: 24-Pin JST PHDR-24VS Header (CN2)
Input Terminal Pinout AC Mains Terminal Block: Pin 1 = Earth Ground (FG), Pin 2 = AC Line (ACL), Pin 3 = AC Neutral (ACN)
Output & Signal Terminal Pinout Main Output: M8 Busbars (+VO, -VO); CN2 (24-Pin JST PHDR-24VS, mating contact SPHD-002T-P0.5): Pin 1 VS+, Pin 2 VO+, Pin 3 VS-, Pin 4 VO-, Pin 5 POK, Pin 6/10/14/16/18/22 GND, Pin 7 PAR (Current Share), Pin 8 VSET (Aux 5V/9V select), Pin 9 EN-, Pin 11 EN+, Pin 12/17/21 AUX, Pin 13 ACI (I Program), Pin 15 VCI (V Program), Pin 19 SCL, Pin 20 SDA, Pin 23 RX*, Pin 24 TX* (*RS232/RS485 driver board only)
Control & Monitoring Signals Remote On/Off (EN+/EN-), Remote Sense (VS+/VS-, up to 0.5 V drop compensation), Active Current Share (PAR, up to 5 units within 5%), Power OK (POK open drain, max 40 V / 20 mA), 0–5 VDC / 0–5 kΩ Voltage & Current Programming (VCI/ACI), Auxiliary Standby (5 VDC 0.5 A or 9 VDC 0.3 A)
Communication Interface I²C Serial Bus (SCL / SDA on CN2 Pins 19 & 20); Optional RS232 / RS485 via external driver board (KIT-RS232-X or KIT-RS485-1)
Status Indicator Multi-Color Diagnostic LED (Solid Green: Output OK; Solid Orange: Output OK Remote Mode; Slow Blink Green/Orange: Disabled; Fast Blink Red: OVP; Solid Red: OLP; Slow Blink Red: OTP; Intermittent Red: Fan Fail; Short/Long Red: AUX Fail)
Terminal Tightening Torque AC Input M4 Screws: 1.3 Nm max.; DC Output M8 Studs: 3.0 Nm (30.5 kgf·cm); Chassis Mounting M4 Screws: 1.27 Nm (13.0 kgf·cm)
Overload Protection (OLP) Threshold 105% of rated output power
Overload Protection (OLP) Mode Constant Current Limiting
Overvoltage Protection (OVP) Threshold Tracks programmed output voltage (114% to 120% nominal at 100% setting)
Overvoltage Protection (OVP) Mode Latching Shutdown (Recycle AC input power to reset)
Overtemperature Protection (OTP) Mode Monitors primary and secondary heatsinks; shuts down output with automatic recovery upon cooling
Short Circuit Protection (SCP) Continuous protection with automatic recovery
Withstand Isolation Voltage (I/P to O/P) 3000 VAC
Withstand Isolation Voltage (I/P to FG / Case) 1500 VAC
Withstand Isolation Voltage (O/P to FG / Case) 500 VAC
Earth Leakage Current 3 mA max. (at 264 VAC / 60 Hz)
Operating Ambient Temperature Range -20 °C to +60 °C (-4 °F to +140 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F)
High-Temperature Derating Rate Linear derating from 100% load at +50 °C (+122 °F) to 50% load at +60 °C (+140 °F) (5%/°C)
Low-Line Input Derating Derates linearly from 2400 W (200.0 A) at 180 VAC to 1600 W (166.6 A) at 90 VAC
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 20% to 90% RH (non-condensing)
Temperature Coefficient ±0.02%/°C (0 °C to +50 °C)
Vibration Resistance 2 g, 10–500 Hz, 10 min/cycle, 60 min per axis (compliant with IEC 60068-2-16 and IEC 60068-2-64)
Safety Approvals (UL / North America) UL 62368-1, CAN/CSA C22.2 No. 62368-1-14
Safety Approvals (IEC / EN / TÜV) CB Report IEC 62368-1:2014, TÜV EN 62368-1:2014/A11:2017
Safety Approvals (Regional / Global) CE, UKCA
EMC Conducted & Radiated Emissions EN 55032 Class A (Conducted & Radiated)
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker)
EMC Immunity Standards EN 55024, EN 61000-4-2 Level 2/3 (±4 kV contact, ±8 kV air, Criteria A), EN 61000-4-3 Level 3 (10 V/m, Criteria A), EN 61000-4-4 Level 3 (Criteria A), EN 61000-4-5 Installation Class 3 (Criteria A), EN 61000-4-6 Level 3 (10 V, Criteria A), EN 61000-4-8 (30 A/m, Criteria A), EN 61000-4-11 (30% dip 500 ms Criteria A; >95% int 10 ms Criteria A; >95% int 5000 ms Criteria B)
MTBF (MIL-HDBK-217F) 90,000 hours (at +25 °C Ground Benign)

Industrial Applications & Compatible Systems

The XP Power HDL3000PS12 is engineered for industrial, laboratory, and automated OEM systems requiring high-current, programmable 12 VDC power delivery:

  • Battery Testing, Formation & Simulation: Provides dynamic 0–105% voltage and current control via I²C or 0–5 VDC analog inputs for automated battery cell cycling, formation racks, and DC bus emulation.
  • Electroplating, Anodizing & Cathodic Protection: Delivers up to 200 A of regulated constant-current or constant-voltage DC power with internal ORing isolation for electrochemical bath control.
  • Industrial Robotics & Factory Automation: Powers high-current 12 VDC servo actuators, AGV charging stations, and distributed automation backplanes with N+1 parallel redundancy.
  • Specialist LED Curing & Laser Diode Systems: Supplies low-ripple, tightly regulated high-current DC drive power for UV/IR industrial curing arrays and solid-state laser pump modules.

Installation, Thermal Management & MRO Guidelines

Observe the following mechanical, electrical, and thermal integration practices when deploying the HDL3000PS12 in industrial enclosures:

  • Airflow & Chassis Mounting Clearance: Maintain unobstructed intake and exhaust clearance along the 316.5 mm longitudinal airflow axis, and limit M4 mounting screw penetration to 3.0 mm (0.12 in) maximum at 1.27 Nm torque to prevent internal PCB contact.
  • High-Current Busbar & Remote Sense Wiring: Torque M8 output studs to 3.0 Nm using heavy-gauge copper lugs, and route twisted-pair remote sense leads (VS+ / VS- on CN2) directly to the load terminals to compensate up to 0.5 V of cable drop (or link locally if unused).
  • Parallel Current Sharing & Line Derating: When paralleling up to five units via the PAR bus (CN2 Pin 7), derate maximum combined output current to 90% of total rated capacity, and account for low-line derating from 2400 W at 180–264 VAC down to 1600 W at 90 VAC.
  • Upstream Circuit Breaker & Enable Configuration: Size upstream AC protection to accommodate the 110 A cold-start inrush current at 230 VAC (43 A at 115 VAC), and retain or wire the CN2 EN+/EN- enable loop using the internal auxiliary standby rail.