DRP024V240W1BN Delta 240W 24VDC DIN Rail Power Supply

$132.56

Delta DRP024V240W1BN 240W 24VDC 10A single-phase DIN rail power supply, 85-264VAC input, featuring 150% 5s Power Boost, conformal coating, and UL 508 approval.

SKU: DRP024V240W1BN Category: Brand:

Description

Delta DRP024V240W1BN is an industrial 240W single-phase DIN rail power supply from the CliQ II Series, where its OEM nomenclature decodes as DRP (DIN Rail Power Supply), 024V (24 VDC output), 240W (240 W rated power), 1 (Single-Phase input), B (CliQ II generation), and N (Standard industrial aluminium casing without hazardous location certification). Engineered around an active Power Factor Correction (PFC) front end coupled with a Half-Bridge LLC (HB-LLC) resonant converter topology, the unit accepts a universal 85–264 VAC (47–63 Hz) or 120–375 VDC input with zero low-line power derating. It delivers a continuous 24 VDC at 10.0 A (240 W)—adjustable from 24 to 28 VDC via a front-panel potentiometer—alongside a reserve 150% Power Boost (15.0 A / 360 W) for up to 5 seconds to start high-inrush inductive loads without upsizing the supply. Operating at conversion efficiencies exceeding 90.0% at 115 VAC and 92.0% at 230 VAC, it maintains tight < 0.5% line regulation, < 1.0% load regulation, and low output ripple and noise below 150 mVpp.

Housed in a rugged, corrosion-resistant full aluminium enclosure measuring 85 mm (W) × 121 mm (H) × 124.1 mm (D) (3.35 × 4.76 × 4.89 in) and weighing 1.10 kg (2.43 lbs), the power supply snaps directly onto standard EN 60715 TS-35 DIN rails. Its protective conformal-coated PCBA shields internal circuitry against industrial dust, humidity, and chemical pollutants, while pluggable screw terminal blocks accommodate AWG 16–12 wiring across a 3-pin AC input and 4-pin dual-pole DC output with a green DC OK LED status indicator. Comprehensive self-recovering hiccup protections guard against overload (> 150%), overvoltage (< 32 VDC ±10%), short circuit, and overtemperature faults, backed by 4.0 kVAC input-to-output galvanic isolation and Overvoltage Category III clearance. Certified to UL 508, IEC/EN/UL 62368-1, and EN 60204-1, the unit starts cold at -40 °C (-40 °F) and operates across -25 °C to +80 °C (-13 °F to +176 °F) with full rated output up to +50 °C (+122 °F).

Key Features

  • 150% Reserve Power Boost for 5 Seconds: Delivers up to 360 W (15.0 A at 24 VDC) of transient surge capacity for 5 seconds, reliably starting solenoids, contactors, and DC motors without requiring an oversized supply.
  • Wide Universal AC/DC Input Without Derating: Operates across 85–264 VAC (47–63 Hz) or 120–375 VDC lines and supports 2-of-3 phase systems, maintaining 100% 240 W output power across the entire input voltage range.
  • High-Efficiency Active PFC & HB-LLC Topology: Achieves > 90.0% efficiency at 115 VAC and > 92.0% at 230 VAC with active power factor correction (> 0.96 at 115 VAC, > 0.90 at 230 VAC) and EN 61000-3-2 Class A compliance.
  • Conformal-Coated PCBA & Aluminium Chassis: Dip-coated internal circuit boards resist conductive dust, moisture, and corrosive chemical vapors, housed inside a lightweight 1.10 kg (2.43 lb) corrosion-resistant aluminium enclosure.
  • Extreme -40°C Cold Start & Wide Thermal Range: Guarantees reliable cold start at -40 °C (-40 °F) and continuous operation from -25 °C to +80 °C (-13 °F to +176 °F), delivering full 240 W load up to +50 °C vertical ambient.
  • Comprehensive Auto-Recovery Protection Suite: Integrates non-latching hiccup overload (> 150%), short-circuit, SELV overvoltage (< 32 V ±10%), and overtemperature protections alongside an internal T6.3AH line fuse.
  • 4.0 kVAC Reinforced Galvanic Isolation & OVC III: Provides 4.0 kVAC input-to-output and 1.5 kVAC input/output-to-ground isolation, meeting EN 62477-1 and EN 60204-1 Overvoltage Category III and Pollution Degree 2 requirements.
  • Global Industrial & ITE Safety Certifications: Fully approved to UL 508 Industrial Control Equipment, UL/cUL/IEC/EN 62368-1, UL/IEC 60950-1, CE, UKCA, CCC, BSMI, BIS, and CISPR 32 / FCC Part 15 Class B radiated and conducted emissions.

Technical Specifications

Manufacturer Delta
Manufacturer Part Number (MPN) DRP024V240W1BN
Product Series CliQ II Series (DRP)
Product Category Single-Phase DIN Rail
Component Type Industrial AC-DC DIN Rail Power Supply
Circuit Topology Active PFC + Half-Bridge LLC (HB-LLC) Resonant Converter
Nominal Output Voltage 24 VDC
Output Voltage Adjustment Range 24 to 28 VDC (via front-panel potentiometer)
Rated Output Current 10.0 A (continuous at 24 VDC)
Peak / Surge Output Current 15.0 A (150% Power Boost for up to 5 seconds at 24 VDC)
Rated Output Power 240 W (continuous at 24 VDC)
Peak Output Power 360 W (150% Power Boost for up to 5 seconds at 24 VDC)
Number of Outputs 1 Output (Single Channel, 4 terminal pins wired in parallel pairs)
Output Ripple & Noise (Max.) < 150 mVpp (20 MHz PARD, measured with 0.1 µF ceramic and 47 µF electrolytic parallel capacitors)
Output Voltage Tolerance ±2.0% (Factory set point tolerance at 24 VDC)
Line Regulation < 0.5% (at 85–264 VAC input, 100% load)
Load Regulation < 1.0% (at 85–264 VAC input, 0–100% load)
Dynamic Load Response ±5.0% max. overshoot/undershoot (0–100% load step, 0.1 A/µs slew rate, 50% duty cycle at 5 Hz to 1 kHz)
Setup Time < 1000 ms (at nominal 115 / 230 VAC input, 100% load)
Rise Time < 100 ms (at nominal 115 / 230 VAC input, 100% load)
Hold-Up Time > 20 ms (at 100% load, 115 / 230 VAC)
Max. Capacitive Load 10,000 µF
AC Input Voltage Range 85 to 264 VAC (Supports single-phase or 2-of-3 phase systems up to 240 VAC +10%)
DC Input Voltage Range 120 to 375 VDC (+pole to L, -pole to N)
Nominal Input Voltage 100 to 240 VAC
Input Frequency Range 47 to 63 Hz (50/60 Hz nominal)
Efficiency (at 115 VAC) > 90.0% (at 100% load)
Efficiency (at 230 VAC) > 92.0% (at 100% load)
AC Input Current (at 115 VAC) < 2.50 A
AC Input Current (at 230 VAC) < 1.30 A
Inrush Current < 35 A (at 115 / 230 VAC)
Power Factor (PF at 115 VAC) > 0.96 (at 100% load)
Power Factor (PF at 230 VAC) > 0.90 (at 100% load)
Power Factor Correction (PFC) Active PFC (Meets IEC/EN 61000-3-2 Class A)
No-Load Power Consumption < 5.7 W (at 115 VAC) / < 4.8 W (at 230 VAC); Full-load dissipation: < 26.6 W (115 VAC) / < 20.8 W (230 VAC)
Internal Input Fuse T6.3AH slow-blow fuse at L (Line) pin (Recommended external branch breaker: min. 8 A B-curve or 6 A C-curve)
Mounting Style DIN Rail TS-35 (35 mm standard rail in accordance with EN 60715)
Cooling Method Natural Free Air Convection (Acoustic noise < 40 dBA at 1 m)
Overall Width (W) 85.0 mm (3.35 in)
Overall Height (H) 121.0 mm (4.76 in)
Overall Depth (D) 124.1 mm (4.89 in)
Net Weight 1.10 kg (2.43 lbs)
Termination / Connector Style Pluggable Screw Terminal Blocks (Rated 300 V / 15 A per pin)
Input Terminal Pinout Bottom Terminal Block (3 Pins): L (Line), N (Neutral), PE (Protective Earth / Ground)
Output & Signal Terminal Pinout Top Terminal Block (4 Pins): +V (Positive 1), +V (Positive 2), -V (Negative/Return 1), -V (Negative/Return 2)
Status Indicator Green LED (DC OK status indicator on front panel)
Terminal Wire Gauge Range AWG 16 to AWG 12 (Copper conductors rated ≥ 60°C / 75°C; use ferrules for flexible stranded wire)
Enclosure / Potting Material Corrosion-resistant full aluminium chassis/cover with protective conformal coating on PCBAs
Overload Protection (OLP) Threshold > 150% of rated load current
Overload Protection (OLP) Mode Hiccup Mode, Non-Latching (Auto-Recovery upon fault removal)
Overvoltage Protection (OVP) Threshold < 32 VDC ±10% (SELV output)
Overvoltage Protection (OVP) Mode Hiccup Mode, Non-Latching (Auto-Recovery)
Overtemperature Protection (OTP) Mode Output voltage bouncing / hiccup mode when ambient exceeds > 80 °C (+176 °F) at 100% load, Non-Latching (Auto-Recovery)
Short Circuit Protection (SCP) Hiccup Mode, Non-Latching (Auto-Recovery when short circuit is removed)
Withstand Isolation Voltage (I/P to O/P) 4.0 kVAC (SELV output, Class I with PE connection)
Withstand Isolation Voltage (I/P to FG / Case) 1.5 kVAC
Withstand Isolation Voltage (O/P to FG / Case) 1.5 kVAC
Earth Leakage Current < 1.0 mA (at 240 VAC)
Operating Ambient Temperature Range -25 °C to +80 °C (-13 °F to +176 °F); Extreme low-temperature cold start at -40 °C (-40 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) in Vertical Mounting; +40 °C (+104 °F) in Horizontal Mounting
High-Temperature Derating Rate Vertical Mounting: 2.5% / °C above +50 °C (up to +80 °C); Horizontal Mounting: 2.5% / °C above +40 °C (up to +80 °C)
Low-Line Input Derating Zero derating (100% full 240 W output maintained from 85 VAC to 264 VAC)
Operating Altitude 0 to 2,500 m (0 to 8,200 ft); CCC safety mark rated up to 2,000 m (6,562 ft)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 5% to 95% RH (Non-condensing, Pollution Degree 2)
Vibration Resistance IEC 60068-2-6: 10–500 Hz at 30 m/s² (3 G peak), 60 min per axis (X, Y, Z); Shock: IEC 60068-2-27 30 G (18 ms); Bump: IEC 60068-2-29 10 G (11 ms, 6,000 bumps)
Ingress Protection (IP) IP20
Safety Approvals (UL / North America) UL 508 & CSA C22.2 No. 107.1-01 Listed (File E315355 / 181564), cURus UL 62368-1 & UL 60950-1 Recognized (File E191395)
Safety Approvals (IEC / EN / TÜV) CB Scheme IEC 62368-1 & IEC 60950-1, SIQ Bauart EN 62368-1, EN 60204-1 (OVC III), IEC/EN/BS EN 62477-1, IEC 62103, SELV
Safety Approvals (Regional / Global) CE (LVD 2014/35/EU, EMC 2014/30/EU), UKCA, CCC (GB4943.1, GB9254, GB17625.1), BSMI (CNS 14336-1), BIS (IS 13252-1), KC (K60950-1)
EMC Conducted & Radiated Emissions CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47 Class B, KN 32, CNS 13438, EN/BS EN 61204-3
EMC Harmonic & Flicker Compliance IEC/EN/BS EN 61000-3-2 Class A (Harmonic Current), IEC/EN/BS EN 61000-3-3 (Voltage Fluctuation & Flicker)
EMC Immunity Standards EN 55024, EN 61000-6-1, EN 61000-6-2, KN 35; IEC 61000-4-2 (ESD Level 4: 15 kV Air / 8 kV Contact, Criteria A), IEC 61000-4-3 (RS Level 3: 10 V/m, Criteria A), IEC 61000-4-4 (EFT Level 3: 2 kV, Criteria A), IEC 61000-4-5 (Surge Level 3: 2 kV CM / 1 kV DM, Criteria A), IEC 61000-4-6 (CS Level 3: 10 Vrms, Criteria A), IEC 61000-4-8 (PFMF: 30 A/m, Criteria A), IEC 61000-4-11 (Voltage Dips: 100% dip for 20 ms, Self-Recoverable), IEC 61000-4-12 (Ring Wave Level 3: 2 kV CM / 1 kV DM, Criteria A)
MTBF (Telcordia SR-332 / Bellcore) > 500,000 hours (at 115 VAC input, 100% load, +25 °C ambient); Expected electrolytic capacitor life: 10 years (50% load at +40 °C)
Environmental Compliance RoHS Compliant

Industrial Applications & Compatible Systems

Engineered for harsh industrial automation and heavy electrical control cabinets, the Delta DRP024V240W1BN provides reliable 24 VDC bus power across demanding OEM and MRO environments:

  • Factory Automation & PLC Control Cabinets: Powers modular PLCs, remote I/O islands, safety relays, and HMI operator panels requiring UL 508 and EN 60204-1 Overvoltage Category III compliance.
  • High-Inrush Electromechanical Actuators: Leverages 150% Power Boost (15.0 A / 360 W for 5 seconds) to energize pneumatic solenoid banks, DC brake coils, stepper drives, and motorized valves without voltage droop.
  • Harsh Environment & Wastewater Processing: Protects internal electronics with dip-applied PCBA conformal coating against high humidity (up to 95% RH), airborne particulates, and corrosive industrial atmospheres.
  • Redundant & High-Power 24 VDC Distribution: Supports N+1 redundant architectures when paired with a Delta DRR-20N/20A redundancy module or parallel load sharing to scale output capacity on critical production lines.

Installation, Thermal Management & MRO Guidelines

To maximize service life and ensure thermal stability inside enclosed switchgear, follow these field engineering and installation practices:

  • Convection Cooling Clearances & Derating: Maintain at least 50 mm (1.97 in) vertical clearance above and below the chassis and 20 mm (0.79 in) lateral spacing in vertical orientation (or 50 mm lateral in horizontal orientation), derating load by 2.5% per °C above +50 °C (+40 °C horizontal).
  • Branch Circuit Breaker & Neutral Protection: Approved for 20 A (UL) and 16 A (IEC) branch circuits without extra fusing; if supplementary protection is installed, select a minimum 8 A B-curve or 6 A C-curve MCB, and add an external fuse on the Neutral (N) line when operating from 2-of-3 phase AC mains or 120–375 VDC buses.
  • Parallel & Redundant Voltage Balancing: For parallel current sharing, trim the output voltages of both units to within 25 mV under identical 50% load; for 1+1 redundancy with a DRR-20 module, set the master PSU 0.45–0.50 V higher than the slave PSU and account for the 0.60–0.90 V ORing module drop.