Description
Mean Well MDR-20-12 (also known as MDR2012) is an industrial single-phase AC-DC DIN rail power supply from the slim 22.5 mm MDR-20 series, where the suffix 20 indicates the 20 W nominal power class and 12 specifies the regulated 12 VDC output. Built around a fixed-frequency 60 kHz PWM switching architecture with integrated input EMI filtering, it accepts a universal 85 to 264 VAC or 120 to 370 VDC input and delivers 1.67 A across an adjustable 10.8 to 13.2 VDC range via a front-panel potentiometer. Achieving 80% typical efficiency with under 0.75 W no-load power consumption, it maintains tight ±1.0% voltage tolerance and ±1.0% line and load regulation with ripple and noise capped at 120 mVp-p.
Engineered for demanding industrial control cabinets, the MDR-20-12 incorporates constant-current overload protection (105% to 160% rated power with automatic recovery), short-circuit protection, and latching shutdown overvoltage protection (13.8 to 16.2 VDC) alongside an active DC OK status signal (9 to 13.5 V / 40 mA max). Three-zone galvanic isolation provides 3 kVAC (I/P-O/P), 2 kVAC (I/P-FG), and 0.5 kVAC (O/P-FG) dielectric withstand strength, while free-air convection cooling supports full-load operation from -20 °C to +50 °C and derated operation up to +70 °C. Housed in a compact 22.5 × 90 × 100 mm (0.89 × 3.54 × 3.94 in) Case 956 enclosure for TS-35/7.5 or TS-35/15 DIN rails, it holds UL 508, TÜV BS EN/EN 62368-1, EAC, BSMI, and Class B EMC certifications.
Key Features
- Precision 20 W / 12 VDC Regulated Output: Delivers 1.67 A continuous current with ±1.0% total voltage tolerance, ±1.0% line/load regulation, 120 mVp-p maximum ripple, and 10.8–13.2 VDC front-panel voltage adjustment.
- Universal AC & High-Voltage DC Input: Operates across 85–264 VAC (47–63 Hz) and 120–370 VDC with 80% typical efficiency and ultra-low no-load power consumption below 0.75 W.
- Built-In DC OK Active Status Signal: Features a dedicated open-collector/active DC OK output rated at 9–13.5 V (40 mA max) plus a front-panel green LED power-on indicator for PLC diagnostics.
- Comprehensive Fault Protection Suite: Integrates auto-recovering constant-current overload protection (105–160% rated load), continuous short-circuit protection, and latching overvoltage shutdown (13.8–16.2 VDC) requiring AC re-power.
- Reinforced 3-Zone Galvanic Isolation: Provides 3 kVAC input-to-output, 2 kVAC input-to-frame ground, and 0.5 kVAC output-to-frame ground dielectric withstand voltage with 100 MΩ isolation resistance at 500 VDC.
- Wide Industrial Temperature & Convection Cooling: Cooled by natural free-air convection across a -20 °C to +70 °C operating window, sustaining 100% full load up to +50 °C without external fans.
- Ultra-Slim 22.5 mm DIN Rail Footprint: Compact Case 956 housing measures 22.5 × 90 × 100 mm (0.89 × 3.54 × 3.94 in) and snaps directly onto standard TS-35/7.5 or TS-35/15 DIN rails.
- Global UL 508 & Class B EMC Compliance: Certified to UL 508 industrial control equipment, TÜV EN 62368-1, and EN 55032 / EN 61204-3 Class B conducted and radiated emissions.
Technical Specifications
| Manufacturer | Mean Well |
|---|---|
| Manufacturer Part Number (MPN) | MDR-20-12 |
| Alternate Part Number | MDR2012 |
| Product Series | MDR-20 Series |
| Product Category | Single-Phase DIN Rail |
| Component Type | Single-Output Industrial DIN Rail AC-DC Power Supply |
| Circuit Topology | Fixed-Frequency PWM Flyback Switching Converter (60 kHz) |
| Nominal Output Voltage | 12 VDC |
| Output Voltage Adjustment Range | 10.8 to 13.2 VDC (via front-panel +V ADJ potentiometer) |
| Rated Output Current | 1.67 A |
| Output Current Range | 0 to 1.67 A |
| Rated Output Power | 20 W (20.04 W nominal) |
| Output Ripple & Noise (Max) | 120 mVp-p (measured at 20 MHz bandwidth with 0.1 µF & 47 µF parallel capacitors) |
| Output Voltage Tolerance | ±1.0% (includes setup tolerance, line regulation, and load regulation) |
| Line Regulation | ±1.0% |
| Load Regulation | ±1.0% |
| Setup Time (at 115 VAC) | 1000 ms (at full load, cold first start) |
| Setup Time (at 230 VAC) | 500 ms (at full load, cold first start) |
| Rise Time (at 115 VAC) | 30 ms (at full load) |
| Rise Time (at 230 VAC) | 30 ms (at full load) |
| Hold-Up Time (at 115 VAC) | 20 ms typical (at full load) |
| Hold-Up Time (at 230 VAC) | 50 ms typical (at full load) |
| AC Input Voltage Range | 85 to 264 VAC (Universal Full Range) |
| DC Input Voltage Range | 120 to 370 VDC |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency (at 230 VAC) | 80% typical (at rated load, 25 °C) |
| AC Input Current (at 115 VAC) | 0.55 A typical |
| AC Input Current (at 230 VAC) | 0.35 A typical |
| Inrush Current (Cold Start at 115 VAC) | 20 A typical |
| Inrush Current (Cold Start at 230 VAC) | 40 A typical |
| No-Load Power Consumption | Less than 0.75 W |
| Switching Frequency | 60 kHz fixed |
| Overload Protection (OLP) Threshold | 105% to 160% rated output power |
| Overload Protection (OLP) Mode | Constant current limiting, recovers automatically after fault condition is removed |
| Overvoltage Protection (OVP) Threshold | 13.8 to 16.2 VDC |
| Overvoltage Protection (OVP) Mode | Shut down output voltage, re-power on to recover |
| Short Circuit Protection (SCP) | Continuous protection via constant current limiting with automatic recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3 kVAC (3000 VAC) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2 kVAC (2000 VAC) |
| Withstand Isolation Voltage (O/P to FG / Case) | 0.5 kVAC (500 VAC) |
| Isolation Resistance (at 500 VDC) | 100 MΩ minimum (I/P-O/P, I/P-FG, O/P-FG at 500 VDC / 25 °C / 70% RH) |
| Earth Leakage Current | Less than 1 mA at 240 VAC |
| Operating Ambient Temperature Range | -20 °C to +70 °C (-4 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% load (vertical mounting) |
| High-Temperature Derating Rate | Linearly derates from 100% load at +50 °C down to 50% load at +70 °C (2.5%/°C) |
| Low-Line Input Derating | Linearly derates from 100% load at 100 VAC down to 80% load at 85 VAC (60 Hz) |
| Altitude Derating | 3.5 °C per 1000 m for operating altitudes above 2000 m (6500 ft) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 20% to 90% RH non-condensing |
| Storage Relative Humidity | 10% to 95% RH |
| Temperature Coefficient | ±0.03%/°C (0 to +50 °C) |
| Vibration Resistance | 10 to 500 Hz, 2G, 10 min./1 cycle, 60 min. each along X, Y, Z axes (IEC 60068-2-6) |
| MTBF (Telcordia SR-332 / Bellcore) | 2,780,800 hours minimum (2780.8K hrs at 25 °C) |
| MTBF (MIL-HDBK-217F) | 236,900 hours minimum (236.9K hrs at 25 °C) |
| Safety Approvals (UL / North America) | UL 508 Listed (Industrial Control Equipment) |
| Safety Approvals (IEC / EN / TÜV) | TÜV BS EN/EN 62368-1, IEC 62368-1, IEC 60950-1 |
| Safety Approvals (Regional / Global) | EAC TP TC 004, BSMI CNS15598-1 (R33100), AS/NZS 62368.1, BIS IS 13252 (Part 1) |
| EMC Conducted & Radiated Emissions | BS EN/EN 55032 (CISPR 32) Class B, BS EN/EN 61204-3 Class B, CNS 15936 Class B, EAC TP TC 020 |
| EMC Harmonic Current Emissions | BS EN/EN 61000-3-2 |
| EMC Voltage Fluctuations & Flicker | BS EN/EN 61000-3-3 |
| EMC ESD Immunity | BS EN/EN 61000-4-2 (Light Industry Level) |
| EMC Radiated RF Immunity | BS EN/EN 61000-4-3 (Light Industry Level) |
| EMC EFT / Burst Immunity | BS EN/EN 61000-4-4 (Light Industry Level) |
| EMC Surge Immunity | BS EN/EN 61000-4-5 (Light Industry Level) |
| EMC Conducted RF Immunity | BS EN/EN 61000-4-6 (Light Industry Level) |
| EMC Power Frequency Magnetic Field Immunity | BS EN/EN 61000-4-8 (Light Industry Level) |
| EMC Voltage Dips & Interruptions Immunity | BS EN/EN 61000-4-11, BS EN/EN 55035, BS EN/EN 61000-6-1, BS EN/EN 61204-3 |
| Control & Monitoring Signal | DC OK Active Signal (9 to 13.5 V output / 40 mA max; min external load R ≥ 1.5 kΩ for 5.1 V logic, ≥ 2.4 kΩ for LED, ≥ 700 Ω for Relay) |
| Status Indicator | Front-panel Green LED for DC Power On |
| Input Terminal Pinout (Bottom TB1) | 3-Position Screw Terminal Block: Pin 1 = FG (Frame Ground), Pin 2 = N (AC Neutral / DC-), Pin 3 = L (AC Line / DC+) |
| Output & Signal Terminal Pinout (Top TB2) | 5-Position Screw Terminal Block: Pin 1 = +V, Pin 2 = -V, Pin 3 = DC OK (+), Pin 4 = DC OK (-), Pin 5 = +V ADJ Potentiometer |
| Cooling Method | Free air convection (fanless) |
| Mounting Style | DIN Rail Mount (TS-35/7.5 or TS-35/15) |
| Enclosure Case Number | Mean Well Case No. 956 |
| Overall Width (W) | 22.5 mm (0.89 in) |
| Overall Height (H) | 90 mm (3.54 in) |
| Overall Depth (D) | 100 mm (3.94 in) |
| Outer Dimensions (W × H × D) | 22.5 × 90 × 100 mm (0.89 × 3.54 × 3.94 in), tolerance ±1 mm |
| Net Weight | 0.17 kg (170 g / 0.37 lbs / 6.00 oz) |
| Environmental Compliance | RoHS Compliant |
Industrial Applications & Compatible Systems
Mean Well MDR-20-12 provides isolated, low-ripple 12 VDC auxiliary power in space-constrained industrial automation enclosures:
- UL 508A Industrial Control Panels & Compact PLC Racks: Supplies clean 12 VDC power to micro-PLCs, digital I/O modules, and status relays while feeding its active DC OK signal directly into a PLC discrete input.
- Industrial Sensors, Photoelectric Switches & Safety Interlocks: Powers 12 VDC inductive proximity sensors, rotary encoders, optical curtains, and solenoid pilot valves in packaging and assembly machinery.
- Building Automation, HVAC & Access Control Cabinets: Delivers Class B EMC-compliant 12 VDC power for BACnet/Modbus field controllers, thermostat gateways, electric door strikes, and security panels.
- Remote Telemetry, IIoT Gateways & Edge Routers: Supports wide 85–264 VAC or 120–370 VDC station battery inputs to power cellular routers, protocol converters, and industrial HMI displays.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: Mount the MDR-20-12 vertically onto a standard TS-35/7.5 or TS-35/15 DIN rail and maintain at least 40 mm of unobstructed vertical clearance above and below the vented Case 956 enclosure for proper free-air convection cooling. When operating in ambient temperatures above +50 °C, derate the continuous load linearly at 2.5%/°C down to 10 W (0.835 A) at +70 °C, and apply an 80% load cap if line voltage dips to 85 VAC. Because cold-start inrush reaches 40 A at 230 VAC, protect the upstream AC branch circuit with a Type C or Type D miniature circuit breaker (MCB) to prevent nuisance magnetic trips during power-up, and ensure external DC OK loads maintain at least 1.5 kΩ impedance for 5.1 V logic interfaces or 700 Ω for relay coils.