Description
XP Power DPC30US12 is an industrial 24 W single-phase DIN rail AC-DC power supply from the ultra-slim DPC30 series, where the MPN nomenclature denotes the DPC30 30 W class DIN rail family, US universal single-output architecture, and a 12 VDC nominal output rail. Engineered around a fixed 65 kHz high-efficiency switching topology, the unit accepts a universal 85 to 264 VAC (47 to 63 Hz) single-phase input and delivers a tightly regulated 12 VDC at 2.00 A (24 W rated power) with a wide front-panel potentiometer adjustment window of 11.4 to 15.6 VDC. It achieves a typical conversion efficiency of 85% at 230 VAC while keeping standby power dissipation below 0.3 W at zero load. Output stability is maintained within ±1% initial set accuracy, ±1% line and load regulation, and 100 mV pk-pk maximum ripple and noise (>90 VAC input at 20 MHz bandwidth), paired with fast transient recovery within 1% in under 2 ms for a 50% step load change.
Housed in an ultra-narrow 22.5 mm (0.89 in) wide enclosure measuring 90.0 mm (3.60 in) high by 100.0 mm (3.94 in) deep and weighing 140.0 g (0.20 lbs), the DPC30US12 maximizes high-density cabinet space on standard TS-35 DIN rails. Front-accessible screw terminals accommodate 10 to 24 AWG field wiring (0.56 Nm / 5.0 lbs-in torque) alongside a green ON status LED and recessed VOUT ADJ trim pot. Comprehensive self-protection encompasses a 140% overload threshold, trip-and-restart (hiccup mode) short-circuit protection, model-specific 16.2 to 18.0 VDC overvoltage protection, and an internal T2.0 A / 250 V fuse. Reinforced by 3000 VAC input-to-output galvanic isolation, natural convection cooling from -25 °C to +70 °C (derating linearly above +40 °C/+50 °C to 50% load at +70 °C), and full compliance with UL 508, UL/EN 62368-1, and EN 55032 Class B standards, it ensures dependable 24/7 operation in industrial automation panels.
Key Features
- Regulated 12 VDC / 2.00 A Output with Wide Voltage Trim: Delivers 24 W continuous output power at 12 VDC with a front-panel potentiometer adjustment range of 11.4 to 15.6 VDC to compensate for long cable voltage drops.
- Ultra-Slim 22.5 mm Cabinet Footprint: Compact 22.5 x 90.0 x 100.0 mm (0.89 x 3.60 x 3.94 in) enclosure occupies minimal horizontal DIN rail space inside crowded PLC and machine control enclosures.
- Green Power Eco-Design Efficiency: Reaches 85% typical efficiency at 230 VAC full load and limits no-load standby power consumption to less than 0.3 W, minimizing cabinet thermal dissipation.
- Low Ripple & Fast Dynamic Transient Recovery: Restricts output ripple and noise to 100 mV pk-pk maximum (>90 VAC) and recovers within 1% in under 2 ms during a 50% step load transition.
- Robust Hiccup Fault & Overvoltage Protection: Integrates 140% overload protection, continuous trip-and-restart hiccup short-circuit protection, 16.2 to 18.0 V overvoltage clamping, and an internal T2.0 A / 250 V input fuse.
- 3000 VAC Reinforced Galvanic Isolation: Provides 3000 VAC input-to-output, 1500 VAC input-to-ground, and 500 VAC output-to-ground dielectric withstand barriers with earth leakage current below 1 mA at 264 VAC.
- Wide -25 °C to +70 °C Convection Operation: Operates via natural air convection across -25 °C to +70 °C (-13 °F to +158 °F) up to 5000 m altitude, backed by 700,000-hour Bellcore MTBF reliability.
- Industrial UL 508 & Class B EMC Compliance: Certified to UL 508 industrial control and UL/EN 62368-1 standards while meeting EN 55032 Class B conducted and radiated emissions without external filtering.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | DPC30US12 |
| Product Series | DPC30 Series |
| Product Category | Single-Phase DIN Rail |
| Component Type | Ultra-Slim Single-Phase DIN Rail AC-DC Power Supply |
| Circuit Topology | Switched-Mode Power Supply (SMPS), 65 kHz Fixed Switching Frequency |
| Nominal Output Voltage | 12 VDC |
| Output Voltage Adjustment Range | 11.4 to 15.6 VDC (via front-panel VOUT ADJ potentiometer; output current must be limited so 24 W nominal power is not exceeded) |
| Rated Output Current | 2.00 A |
| Output Current Range | 0 to 2.00 A (No minimum load required) |
| Rated Output Power | 24 W |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 100 mV pk-pk (at >90 VAC input, 20 MHz bandwidth); 110 mV pk-pk (at 85 VAC input) |
| Output Voltage Tolerance | ±1% max. initial set accuracy (at 100% load) |
| Line Regulation | ±1% max. |
| Load Regulation | ±1% max. |
| Transient Recovery Time & Deviation | 4% max. peak deviation, recovery within 1% in <2 ms (for a 50% step load change at 0.2 A/µs) |
| Setup Time | 1000 ms (1.0 s) max. start-up delay |
| Rise Time | 150 ms max. start-up rise time |
| Hold-Up Time (at 115 VAC) | 20 ms typ. (at full load) |
| Hold-Up Time (at 230 VAC) | 50 ms typ. (at full load) |
| AC Input Voltage Range | 85 to 264 VAC (Single-Phase universal input) |
| Input Frequency Range | 47 to 63 Hz (50 / 60 Hz nominal) |
| Efficiency (at 230 VAC) | 85% typ. (at full load) |
| AC Input Current (at 115 VAC) | 0.55 A typ. (at full load) |
| AC Input Current (at 230 VAC) | 0.35 A typ. (at full load) |
| Inrush Current (Cold Start at 115 VAC) | 20 A typ. |
| Inrush Current (Cold Start at 230 VAC) | 45 A typ. |
| Power Factor Correction (PFC) | Passive harmonic current compliance to EN 61000-3-2 Class A |
| No-Load Power Consumption | <0.3 W max. |
| Switching Frequency | 65 kHz typ. |
| Input Fuse / Internal Protection | T2.0 A / 250 V internal in-line slow-blow fuse |
| Mounting Style | DIN Rail (TS-35/7.5 or TS-35/15 standard rail) |
| Cooling Method | Natural Free Air Convection |
| Overall Width (W) | 22.5 mm (0.89 in) |
| Overall Height (H) | 90.0 mm (3.60 in) |
| Overall Depth (D) | 100.0 mm (3.94 in) |
| Dimensional Tolerance | ±0.5 mm (±0.02 in) |
| Net Weight | 140.0 g (0.14 kg / 0.20 lbs / 4.94 oz) |
| Termination / Connector Style | Front-accessible captive screw terminal blocks |
| Input Terminal Pinout | Bottom Terminal Block (3-Pin, Left to Right): Protective Earth (Ground), N (AC Neutral), L (AC Line) |
| Output & Signal Terminal Pinout | Top Terminal Block (4-Pin, Left to Right): -V, -V (DC Negative Return), +V, +V (DC Positive Output); Front Panel: VOUT ADJ. trim pot, ON green LED |
| Status Indicator | Green LED (ON) indicating DC output active |
| Terminal Wire Gauge Range | 10 to 24 AWG |
| Terminal Tightening Torque | 0.56 Nm (5.0 lbs-in) max. |
| Overload Protection (OLP) Threshold | 140% of rated output power typ. |
| Overload Protection (OLP) Mode | Current limiting with automatic recovery |
| Overvoltage Protection (OVP) Threshold | 16.2 to 18.0 VDC (12 V model) |
| Short Circuit Protection (SCP) | Trip and Restart (Hiccup Mode) with automatic recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC |
| Withstand Isolation Voltage (I/P to FG / Case) | 1500 VAC |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VAC |
| Earth Leakage Current | 1.0 mA max. (at 264 VAC, 60 Hz) |
| Operating Ambient Temperature Range | -25 °C to +70 °C (-13 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) for 12 V / 24 V models (+40 °C / +104 °F for 5 V model) |
| High-Temperature Derating Rate | Derates linearly at 2.5%/°C above +50 °C (or 1.67%/°C above +40 °C) to 50% rated power at +70 °C (+158 °F) |
| Low-Line Input Derating | 100% load from 100 to 264 VAC; derates linearly at 1.0%/VAC from 100 VAC down to 85% output power at 85 VAC |
| Operating Altitude | Up to 5000 m (16,404 ft) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 20% to 95% RH (Non-condensing) |
| Temperature Coefficient | ±0.03%/°C |
| Shock Resistance | IEC 60068-2-27 (15 g peak, 11 ms half-sine pulse, 3 times in each of 6 axes) |
| Vibration Resistance | IEC 60068-2-6 (10 to 500 Hz, 2 g, 10 mins/sweep, 60 mins for each of 3 axes) |
| Safety Approvals (UL / North America) | UL 508 (Industrial Control Equipment), UL 60950-1, UL 62368-1 |
| Safety Approvals (IEC / EN / TÜV) | TÜV, EN 62368-1 (Information Technology Equipment) |
| Safety Approvals (Regional / Global) | CE Mark, UKCA Mark |
| EMC Conducted & Radiated Emissions | EN 55032 Class B (Conducted & Radiated) |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A (Harmonic Current), EN 61000-3-3 (Voltage Fluctuations & Flicker) |
| EMC Immunity Standards | EN 55035, EN 61000-4-2 (ESD: ±8 kV contact / ±15 kV air, Criteria A), EN 61000-4-3 (Radiated: 10 V/m, Criteria A), EN 61000-4-4 (EFT/Burst: Level 4, Criteria A), EN 61000-4-5 (Surge: Installation Class 4, Criteria A), EN 61000-4-6 (Conducted RF: 10 V, Criteria A), EN 61000-4-8 (Magnetic Field: Level 4, Criteria A), Voltage Dips & Interruptions (100% 10 ms Crit A; 30% 10 ms Crit A; 60% 100 ms Crit A/B; 100% 5000 ms Crit B) |
| MTBF (Telcordia SR-332 / Bellcore) | 700,000 Hours min. (Bellcore Issue 6 at +40 °C, Ground Benign) |
| Manufacturer Warranty | 3 Years Standard OEM Warranty |
Industrial Applications & Compatible Systems
The XP Power DPC30US12 is built for space-constrained industrial control cabinets and distributed automation enclosures requiring clean, isolated 12 VDC auxiliary power:
- Industrial PLC, Remote I/O & Sensor Networks: Powers 12 VDC programmable logic controllers, photoelectric proximity sensors, rotary encoders, and signal conditioning transmitters in high-density control panels.
- Building Management & Access Control Systems: Supplies low-noise, Class B EMC-compliant 12 VDC power for electromagnetic door strikes, badge readers, HVAC damper controllers, and security telemetry nodes.
- Industrial Networking, IIoT Gateways & Telemetry: Drives DIN-rail mounted Ethernet switches, RS-485/Modbus serial converters, cellular routers, and SCADA edge gateways with dual +V/-V terminal pairs for simplified daisy-chaining.
- Packaging, Material Handling & OEM Machinery: Provides UL 508 approved 24 W auxiliary power for operator HMI displays, barcode scanners, safety relays, and pneumatic pilot valves on automated production lines.
Installation, Thermal Management & MRO Guidelines
Follow these engineering and panel integration practices to maximize service life and thermal reliability:
- Ambient Thermal & Low-Line Voltage Derating: Maintain natural vertical convection flow and reduce continuous load linearly above +50 °C (down to 12 W / 1.0 A at +70 °C) and below 100 VAC input (down to 85% power / 20.4 W at 85 VAC).
- Output Voltage Trim & Power Ceiling Management: When adjusting the front-panel VOUT ADJ potentiometer upward toward 15.6 VDC, limit continuous load current proportionally so total output power never exceeds the 24 W nominal rating.
- Upstream Breaker Sizing & Terminal Torque: Account for the 45 A cold-start inrush peak at 230 VAC by selecting a C-curve or D-curve miniature circuit breaker, and torque all 10–24 AWG terminal screws to a maximum of 0.56 Nm (5.0 lbs-in).