RWS600B-15/RFO TDK-Lambda 600W 15VDC Chassis Power Supply

$296.28

TDK-Lambda RWS600B-15/RFO (RWS600B15RFO) 600W 15VDC 40A chassis power supply, 85-265VAC input, 84.5% efficiency, with Remote On/Off, DC Good, parallel & Class B EMI.

SKU: RWS600B-15/RFO Category: Brand:

Description

TDK-Lambda RWS600B-15/RFO (also known as RWS600B15RFO) is an industrial 600W enclosed single-output AC-DC power supply from the general-purpose RWS50B–RWS600B series. Decoded from its nomenclature, the RWS600B chassis platform delivers a nominal 15VDC output (adjustable from 13.5V to 17.25V) at up to 40A continuous current, while the /RFO factory option integrates Remote On/Off control, a DC Good status signal, active parallel current-sharing operation, and Remote Sense capability. Engineered with a 190 kHz main switching stage and an active Power Factor Correction (PFC) front end operating at 50–70 kHz (0.95 PF at 100VAC / 0.90 PF at 200VAC), it accepts a universal 85–265VAC (or 120–330VDC) input and achieves 82% typical efficiency at 115VAC and 84.5% at 230VAC with 150 mVp-p maximum ripple and noise.

Built for long-term industrial reliability with conservatively rated electrolytic capacitors, the unit incorporates >105% constant-current overload protection and 115–140% latching overvoltage protection (AC cycle reset). It provides reinforced 3,000VAC input-to-output, 2,000VAC input-to-ground, and 500VAC output-to-ground isolation alongside internal fan-cooled operation across -20°C to +70°C (full 600W load up to +50°C, derating linearly to 50% load at +70°C). Housed in a rugged metal chassis measuring 190 × 120 × 61 mm (7.48 × 4.72 × 2.4 in) with barrier strip terminals and 8-M4 mounting points, the RWS600B-15/RFO complies with EN55032/FCC/VCCI Class B conducted and radiated EMI, SEMI F47 line-dip immunity, and IEC/UL/CSA/EN 62368-1 safety approvals.

Key Features

  • High-Current 15VDC Output: Delivers 600W continuous power at 15VDC nominal (13.5–17.25V trim range) and 40A max current with 60 mV line regulation, 120 mV load regulation, and no minimum load requirement.
  • Integrated /RFO Control Suite: Factory-equipped with Remote On/Off, DC Good monitoring signal, Remote Sense voltage-drop compensation, and active parallel operation for scalable N+1 or higher-current bus architectures.
  • Universal Input & Active PFC: Operates across 85–265VAC (47–63Hz) and 120–330VDC with 300VAC (5s) surge withstand, achieving 0.95/0.90 power factor (100/200VAC) and up to 84.5% typical efficiency at 230VAC.
  • Class B EMI & SEMI F47 Immunity: Meets EN55011/EN55032-B, FCC Class B, and VCCI-B conducted and radiated limits without external filtering, plus IEC 61000-4-x immunity and SEMI F47 voltage sag compliance above 200VAC.
  • Robust Isolation & Fault Protection: Features 3,000VAC input-to-output isolation, 2,000VAC input-to-ground isolation, >105% constant-current overcurrent protection, and 115–140% overvoltage shutdown with AC line reset.
  • Industrial Thermal & MTBF Rating: Internal fan cooling supports 100% load from -20°C to +50°C (derating linearly to 50% at +70°C) up to 3,000 m altitude, backed by 2,157,340 hours Telcordia SR-332 MTBF and a 7-year warranty.

Technical Specifications

Manufacturer TDK-Lambda
Manufacturer Part Number (MPN) RWS600B-15/RFO
Alternate Part Number RWS600B15RFO
Product Series RWS50B-RWS600B Series (RWS600B)
Product Category PSU Mounting Brackets
Component Type Enclosed Single-Output AC-DC Switching Power Supply
Circuit Topology Active PFC + High-Frequency Switching Converter (190 kHz Main / 50–70 kHz PFC)
Nominal Output Voltage 15 VDC
Output Voltage Adjustment Range 13.5 to 17.25 VDC (via onboard potentiometer)
Rated Output Current 40 A
Output Current Range 0 to 40 A (No minimum load required)
Rated Output Power 600 W
Output Ripple & Noise (Max) 150 mVp-p
Line Regulation (Max) 60 mV (±0.4%)
Load Regulation (Max) 120 mV (±0.8%)
Temperature Coefficient 0.02 %/°C
Maximum External Load Capacitance 10,000 µF
Hold-Up Time (Typ at 110 VAC) 20 ms
Hold-Up Time (Typ at 220 VAC) 20 ms
Operating AC Input Voltage Range 85 to 265 VAC
Nominal / Safety-Certified AC Input Range 100 to 240 VAC Nominal (Safety certified for 90 to 264 VAC)
DC Input Voltage Range 120 to 330 VDC (Note: Safety certified for AC input only)
Input Frequency Range 47 to 63 Hz (Safety certified for 50 / 60 Hz)
Input Surge Voltage Withstand 300 VAC for 5 seconds
Efficiency (Typ at 115 VAC) 82%
Efficiency (Typ at 230 VAC) 84.5%
AC Input Current (Typ at 115 VAC) 6.6 A
AC Input Current (Typ at 230 VAC) 3.6 A
Inrush Current (Cold Start at 200 VAC, Typ) 40 A
Power Factor (Typ at 100 VAC) 0.95
Power Factor (Typ at 200 VAC) 0.90
Switching Frequency 190 kHz (Main Converter) / 50 to 70 kHz (PFC Stage)
Overcurrent Protection (OCP) Threshold >105% of rated output current
Overcurrent Protection (OCP) Mode Constant current characteristics
Overvoltage Protection (OVP) Threshold 115% to 140% of nominal output voltage (17.25 to 21.0 VDC)
Overvoltage Protection (OVP) Mode Latching shutdown; cycle AC input line to reset
Withstand Isolation Voltage (I/P to O/P) 3,000 VAC (1 minute)
Withstand Isolation Voltage (I/P to FG / Ground) 2,000 VAC (1 minute)
Withstand Isolation Voltage (O/P to FG / Ground) 500 VAC (1 minute)
Earth Leakage Current <750 µA max (Typically 175 µA at 115 VAC, 63 Hz)
Operating Ambient Temperature Range -20 °C to +70 °C (-4 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 100% load (600 W)
High-Temperature Derating Rate Linear derating above +50 °C (+122 °F) at 2.5 %/°C down to 50% load (300 W) at +70 °C (+158 °F)
Storage Temperature Range -30 °C to +75 °C (-22 °F to +167 °F)
Operating Humidity Range 30% to 90% RH (Non-condensing)
Storage Humidity Range 10% to 90% RH (Non-condensing)
Maximum Operating Altitude 3,000 m (9,842 ft)
Vibration Resistance (Non-Operating) 10 to 55 Hz (1-minute sweep), 19.6 m/s² (2G) constant along X, Y, Z axes for 1 hour each
Shock Resistance (Non-Operating) <196 m/s² (20G), 11 ms half-sine, ±X, ±Y, ±Z axes, 3 times each
MTBF (Telcordia SR-332 Issue 3) 2,157,340 hours (at +25 °C ambient, full load)
Safety Certifications & Markings IEC/UL/CSA/EN 62368-1, CE Mark, UKCA Mark
Conducted & Radiated EMI Emissions EN 55011 Class B, EN 55032 Class B, FCC Part 15 Class B, VCCI Class B
Harmonic Current Compliance Designed to meet IEC 61000-3-2
EMC Immunity – Electrostatic Discharge (ESD) EN 61000-4-2: Air ±8 kV, Contact ±4 kV (Performance Criteria B)
EMC Immunity – Radiated RF Field EN 61000-4-3: 80 MHz–1 GHz at 10 V/m; 1.4–2.0 GHz at 3 V/m; 2.0–2.7 GHz at 1 V/m (Criteria A)
EMC Immunity – Electrical Fast Transient / Burst EN 61000-4-4: ±2 kV (Performance Criteria B)
EMC Immunity – Line Surge EN 61000-4-5: Normal mode ±2 kV, Common mode ±4 kV (Performance Criteria B)
EMC Immunity – Conducted RF EN 61000-4-6: 10 Vrms (Performance Criteria A)
EMC Immunity – Power Frequency Magnetic Field EN 61000-4-8: 30 A/m (Performance Criteria A)
EMC Immunity – Voltage Dips & Interruptions EN 61000-4-11: 30% dip 500 ms (Criteria B); 60% dip 10 ms (Criteria B); 100% dip 20 ms (Criteria A); 100% dip 5000 ms (Criteria B)
Semiconductor Line Sag Immunity SEMI F47 compliant at input voltages >200 VAC
Factory Option Code (/RFO) Remote On/Off, DC Good Signal, Parallel Operation, and Remote Sense
Remote On/Off Control Included (/RFO option)
DC Good Status Signal Included (/RFO option)
Parallel Operation Capability Included (/RFO option)
Remote Sense Function Included (600W series feature)
Input Terminal Block Specification 3-position M3.5 barrier terminal strip with protective cover (L, N, FG)
Output Terminal Block Specification 4-position M5 barrier terminal strip with protective cover (+V, -V)
Cooling Method Forced air cooling via built-in internal fan
Mounting Method & Chassis Holes Chassis mount via 8-M4 bottom/side countersink holes (max screw penetration depth: 6 mm / 0.24 in)
Overall Length (L) 190 mm (7.48 in)
Overall Width (W) 120 mm (4.72 in)
Overall Height (H) 61 mm (2.40 in)
Overall Dimensions (L × W × H) 190 × 120 × 61 mm (7.48 × 4.72 × 2.40 in)
Net Weight (Typ) 1,600 g (1.60 kg / 3.53 lbs)
Enclosure / Case Material Metal chassis
Manufacturer Warranty 7 years ( and EMEA regions) / 5 years (Other regions)

Industrial Applications & Compatible Systems

The TDK-Lambda RWS600B-15/RFO is engineered for mid-to-high power 15VDC industrial, test, and automation architectures requiring remote supervisory control and scalable current delivery:

  • Automated Test & Burn-In Systems (ATE): Supplies clean 15VDC power at up to 40A with Remote Sense lead-drop compensation and Remote On/Off sequencing for semiconductor handlers and board testers.
  • Factory Automation & Machine Control Panels: Powers 15VDC actuators, solenoid manifolds, vision lighting arrays, and distributed I/O racks inside IEC 62368-1 compliant industrial enclosures.
  • Redundant & Parallel High-Current Buses: Combines multiple RWS600B-15/RFO modules via the built-in parallel current-sharing and DC Good monitoring signals to achieve 1,200W+ capacity or N+1 fault tolerance.
  • Broadcast, RF & Laboratory Instrumentation: Delivers low-ripple (150 mVp-p) 15VDC rails with Class B conducted and radiated EMI compliance to prevent interference in sensitive analog and RF test benches.

Installation, Thermal Management & MRO Guidelines

Installation & Engineering Guidelines: Mount the chassis securely using the 8-M4 countersink holes while strictly limiting mounting screw penetration to 6 mm (0.24 in) maximum to prevent internal PCB clearance violations. Maintain unobstructed airflow along the internal cooling fan axis (minimum 50 mm clearance at intake and exhaust vents), and apply a linear thermal derating of 2.5%/°C above +50°C ambient (capping output at 300W / 20A at +70°C). Because cold-start inrush reaches 40A at 200VAC and steady-state draw is 6.6A at 115VAC, protect the AC input with a 10A or 15A Type-C/D miniature circuit breaker or slow-blow fuse, and use twisted sense wires when connecting Remote Sense to compensate for high-current 40A busbar voltage drops.