Description
Delta DRP024V240W1BA is an industrial-grade 240W 24VDC single-phase DIN rail power supply from the CliQ II Series, where the “1BA” suffix denotes a single-phase aluminum enclosure with conformal-coated PCBAs and full ATEX and Class I, Division 2 hazardous location certifications. Engineered around a high-efficiency Active PFC and Half-Bridge LLC (HB-LLC) resonant converter topology, the unit accepts a universal 85–264 VAC (47–63 Hz) or 120–375 VDC input with zero low-line power derating and achieves up to >92.0% efficiency at 230 VAC. It delivers a tightly regulated 24 VDC nominal output (adjustable from 24–28 VDC) at 10.0 A continuous current, backed by a 150% Power Boost reserve (15.0 A / 360 W for 5 seconds) to start heavy inductive loads without oversizing the supply. Output quality is maintained with <150 mVpp ripple and noise (PARD), <0.5% line regulation, <1.0% load regulation, and startup stability across capacitive loads up to 10,000 µF.
Housed in a rugged, corrosion-resistant full aluminum chassis measuring 85 mm (W) × 121 mm (H) × 124.1 mm (D) (3.35 × 4.76 × 4.89 in) and weighing 1.10 kg (2.43 lbs), the supply snaps directly onto standard TS-35 DIN rails (EN 60715). Wiring is streamlined via front-accessible 3-pin input (L, N, PE) and 4-pin output (+, +, -, -) pluggable screw terminal blocks supporting 16–12 AWG conductors, paired with a front-panel voltage trimmer and a green DC OK LED indicator. Comprehensive self-recovering hiccup protection guards against overload (>150%), short circuit, overvoltage (<32 V ±10%), and overtemperature, alongside 4.0 kVAC input-to-output galvanic isolation and Overvoltage Category III impulse immunity. Certified to UL 508, IEC/EN/UL 62368-1, ANSI/ISA 12.12.01 Class I Div 2 (Groups A, B, C, D T4), ATEX II 3G Ex nA nC IIC T4 Gc, and EN 55032 Class B EMC, it operates reliably from -25 °C to +80 °C (with -40 °C cold start and full rated power up to +50 °C vertically).
Key Features
- 150% Power Boost Reserve (360W / 15A): Delivers 240 W (10.0 A) continuously at 24 VDC and provides up to 360 W (15.0 A) surge capacity for 5 seconds to reliably start solenoids, DC motors, and high-inrush actuators.
- ATEX & Class I Div 2 Hazardous Location Certified: Carries cCSAus Class I, Division 2 (Groups A, B, C, D T4) and ATEX II 3G Ex nA nC IIC T4 Gc approvals for explosive petrochemical and process environments.
- Conformal-Coated PCBA & Aluminum Chassis: Precision dip-applied conformal coating shields internal circuit nodes against moisture, salt spray, and chemical pollutants, encased in a rugged 85 × 121 × 124.1 mm corrosion-resistant aluminum enclosure.
- Universal AC/DC Input Without Low-Line Derating: Operates across 85–264 VAC (47–63 Hz), 120–375 VDC, or 2-of-3-phase systems with full 240 W output power across the entire input voltage range and active PFC (>0.96 at 115 VAC).
- High Efficiency & Low Thermal Dissipation: Active PFC plus HB-LLC resonant conversion achieves >90.0% efficiency at 115 VAC and >92.0% at 230 VAC, limiting full-load heat dissipation to <20.8 W at 230 VAC.
- Wide -25°C to +80°C Range with -40°C Cold Start: Sustains 100% continuous 240 W load up to +50 °C in vertical DIN rail orientation (derating linearly at 2.5%/°C above +50 °C) and guarantees cold startup at -40 °C.
- 4.0 kVAC Galvanic Isolation & OVC III Immunity: Provides 4.0 kVAC input-to-output and 1.5 kVAC input/output-to-ground isolation, meeting EN 62477-1 and EN 60204-1 Overvoltage Category III and EN 55032 Class B emissions.
- Auto-Recovery Hiccup Protection Suite: Integrates non-latching hiccup overload (>150%), short-circuit, overvoltage (<32 V ±10% SELV), and overtemperature (<80 °C) protections, plus 10,000 µF capacitive load startup capability.
Technical Specifications
| Manufacturer | Delta |
|---|---|
| Manufacturer Part Number (MPN) | DRP024V240W1BA |
| Product Series | CliQ II Series |
| Compatible Equipment / Series | Delta DRR-20N / DRR-20A Redundancy Modules, TS-35 Industrial Control Cabinets, Hazardous Area Class I Div 2 / ATEX Zone 2 PLC & DCS Racks |
| Product Category | Single-Phase DIN Rail |
| Component Type | Industrial AC-DC DIN Rail Power Supply (Conformal Coated, Hazardous Location Rated) |
| Circuit Topology | Active PFC + Half-Bridge LLC (HB-LLC) Resonant Converter |
| Nominal Output Voltage | 24 VDC |
| Output Voltage Adjustment Range | 24 to 28 VDC (via front-panel potentiometer) |
| Rated Output Current | 10.0 A (continuous at 24 VDC) |
| Peak / Surge Output Current | 15.0 A (150% Power Boost for up to 5 seconds at 24 VDC) |
| Rated Output Power | 240 W (continuous at 24 VDC) |
| Peak Output Power | 360 W (150% Power Boost for up to 5 seconds at 24 VDC) |
| Number of Outputs | 1 (Single Output, 4 parallel output terminal pins: 2x +V, 2x -V) |
| Output Ripple & Noise (Max.) | < 150 mVpp (PARD at 20 MHz bandwidth, terminated with 0.1 µF ceramic & 47 µF electrolytic capacitor) |
| Output Voltage Tolerance | ± 2.0% (Factory Set Point Tolerance at 24 VDC) |
| Line Regulation | < 0.5% (at 85–264 VAC input, 100% load) |
| Load Regulation | < 1.0% (at 85–264 VAC input, 0–100% load) |
| Setup Time | < 1000 ms (at nominal 115 / 230 VAC input, 100% load) |
| Rise Time | < 100 ms (at nominal 115 / 230 VAC input, 100% load) |
| Hold-Up Time | > 20 ms (at 100% load, 115 / 230 VAC) |
| Max. Capacitive Load | 10,000 µF |
| Nominal Input Voltage | 100 to 240 VAC (Single-Phase or 2 of 3-Phase System up to 240 VAC +10%) |
| AC Input Voltage Range | 85 to 264 VAC |
| DC Input Voltage Range | 120 to 375 VDC |
| Input Frequency Range | 47 to 63 Hz (50/60 Hz nominal) |
| Efficiency (at 115 VAC) | > 90.0% (at 100% load; Max Power Dissipation < 26.6 W) |
| Efficiency (at 230 VAC) | > 92.0% (at 100% load; Max Power Dissipation < 20.8 W) |
| AC Input Current (at 115 VAC) | < 2.50 A |
| AC Input Current (at 230 VAC) | < 1.30 A |
| Inrush Current | < 35 A (at 115 / 230 VAC) |
| Power Factor (PF at 115 VAC) | > 0.96 (at 100% load) |
| Power Factor (PF at 230 VAC) | > 0.90 (at 100% load) |
| Power Factor Correction (PFC) | Active PFC (Conforms to IEC/EN 61000-3-2 Class A) |
| No-Load Power Consumption | < 5.7 W (at 115 VAC), < 4.8 W (at 230 VAC) |
| Mounting Style | DIN Rail TS-35 (in accordance with EN 60715) |
| Cooling Method | Free Air Convection (Natural Convection; Acoustic Noise SPL < 40 dBA at 1 m) |
| Overall Width (W) | 85.0 mm (3.35 in) |
| Overall Height (H) | 121.0 mm (4.76 in) |
| Overall Depth (D) | 124.1 mm (4.89 in) |
| Net Weight | 1.10 kg (2.43 lbs) |
| Termination / Connector Style | Pluggable Screw Terminal Blocks (3-Pin Input & 4-Pin Output, rated 300 V / 15 A) |
| Input Terminal Pinout | Bottom Terminal Block (3-Pin): L (Line, with internal T6.3AH fuse), N (Neutral), PE (Primary Earth / Ground) |
| Output & Signal Terminal Pinout | Top Terminal Block (4-Pin): +V (Positive Output 1), +V (Positive Output 2), -V (Negative Return 1), -V (Negative Return 2) |
| Status Indicator | Green LED (DC OK) |
| Terminal Wire Gauge Range | AWG 16 to 12 (Flexible cables require ferrules; use copper wire rated >= 60 °C / 75 °C) |
| Enclosure / Potting Material | Full Corrosion-Resistant Aluminum Casing with Conformal-Coated PCBA |
| Overload Protection (OLP) Threshold | > 150% of rated load current |
| Overload Protection (OLP) Mode | Hiccup Mode, Non-Latching (Auto-Recovery upon fault removal) |
| Overvoltage Protection (OVP) Threshold | < 32 VDC ± 10% (SELV Output) |
| Overvoltage Protection (OVP) Mode | Hiccup Mode, Non-Latching (Auto-Recovery) |
| Overtemperature Protection (OTP) Mode | < 80 °C Surrounding Air Temperature at 100% load; Bouncing Mode, Non-Latching (Auto-Recovery) |
| Short Circuit Protection (SCP) | Hiccup Mode, Non-Latching (Auto-Recovery when short circuit is removed) |
| Withstand Isolation Voltage (I/P to O/P) | 4.0 kVAC |
| Withstand Isolation Voltage (I/P to FG / Case) | 1.5 kVAC |
| Withstand Isolation Voltage (O/P to FG / Case) | 1.5 kVAC |
| Earth Leakage Current | < 1.0 mA (at 240 VAC) |
| Operating Ambient Temperature Range | -25 °C to +80 °C (-13 °F to +176 °F); Cold Start at -40 °C (-40 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) for Vertical Mounting; +40 °C (+104 °F) for Horizontal Mounting |
| High-Temperature Derating Rate | 2.5% / °C above +50 °C (Vertical Mounting); 2.5% / °C above +40 °C (Horizontal Mounting) |
| Low-Line Input Derating | Zero derating across entire 85–264 VAC input voltage range |
| Altitude Derating | 0 to 2,500 m (8,200 ft) operating altitude (2,000 m max for CCC compliance) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 5% to 95% RH (Non-Condensing) |
| Vibration Resistance | Vibration (IEC 60068-2-6): 10–500 Hz @ 3G (30 m/s²) peak, 60 min/axis (X, Y, Z); Shock (IEC 60068-2-27): 30G (300 m/s²) for 18 ms; Bump (IEC 60068-2-29): 10G for 11 ms (6,000 times total) |
| Ingress Protection (IP) | IP20 (Install inside IP54 enclosure for ATEX / Class I Div 2 compliance) |
| Safety Approvals (UL / North America) | UL 508 & CSA C22.2 No. 107.1-01 Listed (File E315355), UL/cUL 62368-1 & UL/cUL 60950-1 Recognized (File E191395), cCSAus Class I Div 2 Groups A, B, C, D T4 per ANSI/ISA 12.12.01:2011 & CSA C22.2 No. 213-M1987 |
| Safety Approvals (IEC / EN / TÜV) | ATEX II 3G Ex nA nC IIC T4 Gc (EN 60079-0:2009, EN 60079-15:2010, Cert. EPS 12 ATEX 1 491 X), CB Scheme IEC 62368-1 & IEC 60950-1 (SELV), SIQ Bauart EN 62368-1, EN 60204-1 (OVC III), IEC/EN 62477-1, IEC 62103 |
| Safety Approvals (Regional / Global) | CE (LVD 2014/35/EU, EMC 2014/30/EU, ATEX 2014/34/EU), UKCA, CCC (GB4943.1, GB9254, GB17625.1), BSMI (CNS 14336-1), BIS (IS 13252-1), KC (K60950-1) |
| EMC Conducted & Radiated Emissions | CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B, KN 32, CNS 13438, EN/BS EN 61204-3 |
| EMC Harmonic & Flicker Compliance | IEC/EN/BS EN 61000-3-2 Class A (Harmonic Current), IEC/EN/BS EN 61000-3-3 (Voltage Fluctuation & Flicker) |
| EMC Immunity Standards | EN 55024, EN 61000-6-1, EN 61000-6-2, KN 35; IEC 61000-4-2 (ESD Level 4: 15 kV Air / 8 kV Contact, Criteria A), IEC 61000-4-3 (Radiated 10 V/m, 80 MHz–1 GHz, Level 3 Criteria A), IEC 61000-4-4 (EFT 2 kV, Level 3 Criteria A), IEC 61000-4-5 (Surge Level 3: 2 kV Common Mode / 1 kV Differential Mode, Criteria A), IEC 61000-4-6 (Conducted 10 Vrms, Level 3 Criteria A), IEC 61000-4-8 (Magnetic 30 A/m, Criteria A), IEC 61000-4-11 (Voltage Dips: 100% dip for 1 cycle / 20 ms, Self-Recoverable), IEC 61000-4-12 (Ring Wave Level 3: 2 kV CM / 1 kV DM, Criteria A) |
| MTBF (Telcordia SR-332 / Bellcore) | > 500,000 Hours (per Telcordia SR-332 at 115 VAC input, 100% load, 25 °C ambient; Expected Electrolytic Capacitor Life: 10 Years at 50% load, 40 °C) |
| Environmental Compliance | RoHS Compliant, Conformal Coated PCBA, Pollution Degree 2 |
Industrial Applications & Compatible Systems
Delta DRP024V240W1BA is engineered for mission-critical 24 VDC industrial automation and hazardous location control panels requiring high transient reserve and chemical resistance:
- Oil, Gas & Petrochemical Hazardous Locations (Class I Div 2 / ATEX Zone 2): Powers remote telemetry units (RTUs), gas analyzers, intrinsically safe barrier racks, and custody transfer skids operating in explosive gas atmospheres classified under Groups A, B, C, D T4 and ATEX IIC T4 Gc.
- Inductive Actuator, Solenoid & Motor Starter Buses: Utilizes its 150% Power Boost (360 W / 15.0 A for 5 seconds) and 10,000 µF capacitive startup drive to energize pneumatic solenoid banks, DC contactors, and motorized valves without voltage droop.
- Corrosive Wastewater, Marine & Chemical Processing Cabinets: Protects internal circuitry against humid, salt-laden, and chemically aggressive plant atmospheres using Delta’s full-immersion conformal PCBA coating and corrosion-resistant aluminum enclosure.
- High-Availability Redundant PLC & DCS Control Systems: Pairs with Delta DRR-20N or DRR-20A redundancy modules in 1+1 redundant or parallel load-sharing architectures for factory automation, packaging lines, and power generation switchgear.
Installation, Thermal Management & MRO Guidelines
Follow these engineering and panel integration practices to maintain thermal reliability and safety certification compliance:
- Convection Cooling Clearances & Thermal Derating: Maintain at least 50 mm (1.97 in) vertical clearance above and below the unit and 20 mm (0.79 in) lateral spacing in vertical TS-35 mounting (or 50 mm lateral spacing if mounted horizontally); derate continuous output power by 2.5%/°C above +50 °C vertically (+40 °C horizontally).
- Hazardous Area Enclosure & Branch Circuit Protection: For ATEX Zone 2 and Class I, Division 2 installations, mount the supply inside an IP54-rated enclosure compliant with EN 60079-0/15, never disconnect terminals or adjust the trimmer while energized, and protect high-ampacity feeds with a minimum 8 A B-curve or 6 A C-curve circuit breaker (plus an external Neutral fuse when wired across 2 of 3 phases).
- Redundant & Parallel Voltage Balancing: For 1+1 redundancy with a DRR-20N/20A ORing module, set the master and slave supplies within a 0.45–0.50 V differential at 50% load and account for the 0.60–0.90 V ORing drop; for direct parallel current sharing, trim both outputs within 25 mV under identical load conditions.