DRP024V240W1BA Delta 240W 24VDC DIN Rail Power Supply

$138.44

Delta DRP024V240W1BA 240W 24VDC 10A single-phase DIN rail power supply, 85-264VAC input, featuring 150% 5s Power Boost, conformal coating, and ATEX/Class I Div 2.

SKU: DRP024V240W1BA Category: Brand:

Description

Delta DRP024V240W1BA is an industrial-grade 240W 24VDC single-phase DIN rail power supply from the CliQ II Series, where the “1BA” suffix denotes a single-phase aluminum enclosure with conformal-coated PCBAs and full ATEX and Class I, Division 2 hazardous location certifications. Engineered around a high-efficiency Active PFC and Half-Bridge LLC (HB-LLC) resonant converter topology, the unit accepts a universal 85–264 VAC (47–63 Hz) or 120–375 VDC input with zero low-line power derating and achieves up to >92.0% efficiency at 230 VAC. It delivers a tightly regulated 24 VDC nominal output (adjustable from 24–28 VDC) at 10.0 A continuous current, backed by a 150% Power Boost reserve (15.0 A / 360 W for 5 seconds) to start heavy inductive loads without oversizing the supply. Output quality is maintained with <150 mVpp ripple and noise (PARD), <0.5% line regulation, <1.0% load regulation, and startup stability across capacitive loads up to 10,000 µF.

Housed in a rugged, corrosion-resistant full aluminum chassis measuring 85 mm (W) × 121 mm (H) × 124.1 mm (D) (3.35 × 4.76 × 4.89 in) and weighing 1.10 kg (2.43 lbs), the supply snaps directly onto standard TS-35 DIN rails (EN 60715). Wiring is streamlined via front-accessible 3-pin input (L, N, PE) and 4-pin output (+, +, -, -) pluggable screw terminal blocks supporting 16–12 AWG conductors, paired with a front-panel voltage trimmer and a green DC OK LED indicator. Comprehensive self-recovering hiccup protection guards against overload (>150%), short circuit, overvoltage (<32 V ±10%), and overtemperature, alongside 4.0 kVAC input-to-output galvanic isolation and Overvoltage Category III impulse immunity. Certified to UL 508, IEC/EN/UL 62368-1, ANSI/ISA 12.12.01 Class I Div 2 (Groups A, B, C, D T4), ATEX II 3G Ex nA nC IIC T4 Gc, and EN 55032 Class B EMC, it operates reliably from -25 °C to +80 °C (with -40 °C cold start and full rated power up to +50 °C vertically).

Key Features

  • 150% Power Boost Reserve (360W / 15A): Delivers 240 W (10.0 A) continuously at 24 VDC and provides up to 360 W (15.0 A) surge capacity for 5 seconds to reliably start solenoids, DC motors, and high-inrush actuators.
  • ATEX & Class I Div 2 Hazardous Location Certified: Carries cCSAus Class I, Division 2 (Groups A, B, C, D T4) and ATEX II 3G Ex nA nC IIC T4 Gc approvals for explosive petrochemical and process environments.
  • Conformal-Coated PCBA & Aluminum Chassis: Precision dip-applied conformal coating shields internal circuit nodes against moisture, salt spray, and chemical pollutants, encased in a rugged 85 × 121 × 124.1 mm corrosion-resistant aluminum enclosure.
  • Universal AC/DC Input Without Low-Line Derating: Operates across 85–264 VAC (47–63 Hz), 120–375 VDC, or 2-of-3-phase systems with full 240 W output power across the entire input voltage range and active PFC (>0.96 at 115 VAC).
  • High Efficiency & Low Thermal Dissipation: Active PFC plus HB-LLC resonant conversion achieves >90.0% efficiency at 115 VAC and >92.0% at 230 VAC, limiting full-load heat dissipation to <20.8 W at 230 VAC.
  • Wide -25°C to +80°C Range with -40°C Cold Start: Sustains 100% continuous 240 W load up to +50 °C in vertical DIN rail orientation (derating linearly at 2.5%/°C above +50 °C) and guarantees cold startup at -40 °C.
  • 4.0 kVAC Galvanic Isolation & OVC III Immunity: Provides 4.0 kVAC input-to-output and 1.5 kVAC input/output-to-ground isolation, meeting EN 62477-1 and EN 60204-1 Overvoltage Category III and EN 55032 Class B emissions.
  • Auto-Recovery Hiccup Protection Suite: Integrates non-latching hiccup overload (>150%), short-circuit, overvoltage (<32 V ±10% SELV), and overtemperature (<80 °C) protections, plus 10,000 µF capacitive load startup capability.

Technical Specifications

Manufacturer Delta
Manufacturer Part Number (MPN) DRP024V240W1BA
Product Series CliQ II Series
Compatible Equipment / Series Delta DRR-20N / DRR-20A Redundancy Modules, TS-35 Industrial Control Cabinets, Hazardous Area Class I Div 2 / ATEX Zone 2 PLC & DCS Racks
Product Category Single-Phase DIN Rail
Component Type Industrial AC-DC DIN Rail Power Supply (Conformal Coated, Hazardous Location Rated)
Circuit Topology Active PFC + Half-Bridge LLC (HB-LLC) Resonant Converter
Nominal Output Voltage 24 VDC
Output Voltage Adjustment Range 24 to 28 VDC (via front-panel potentiometer)
Rated Output Current 10.0 A (continuous at 24 VDC)
Peak / Surge Output Current 15.0 A (150% Power Boost for up to 5 seconds at 24 VDC)
Rated Output Power 240 W (continuous at 24 VDC)
Peak Output Power 360 W (150% Power Boost for up to 5 seconds at 24 VDC)
Number of Outputs 1 (Single Output, 4 parallel output terminal pins: 2x +V, 2x -V)
Output Ripple & Noise (Max.) < 150 mVpp (PARD at 20 MHz bandwidth, terminated with 0.1 µF ceramic & 47 µF electrolytic capacitor)
Output Voltage Tolerance ± 2.0% (Factory Set Point Tolerance at 24 VDC)
Line Regulation < 0.5% (at 85–264 VAC input, 100% load)
Load Regulation < 1.0% (at 85–264 VAC input, 0–100% load)
Setup Time < 1000 ms (at nominal 115 / 230 VAC input, 100% load)
Rise Time < 100 ms (at nominal 115 / 230 VAC input, 100% load)
Hold-Up Time > 20 ms (at 100% load, 115 / 230 VAC)
Max. Capacitive Load 10,000 µF
Nominal Input Voltage 100 to 240 VAC (Single-Phase or 2 of 3-Phase System up to 240 VAC +10%)
AC Input Voltage Range 85 to 264 VAC
DC Input Voltage Range 120 to 375 VDC
Input Frequency Range 47 to 63 Hz (50/60 Hz nominal)
Efficiency (at 115 VAC) > 90.0% (at 100% load; Max Power Dissipation < 26.6 W)
Efficiency (at 230 VAC) > 92.0% (at 100% load; Max Power Dissipation < 20.8 W)
AC Input Current (at 115 VAC) < 2.50 A
AC Input Current (at 230 VAC) < 1.30 A
Inrush Current < 35 A (at 115 / 230 VAC)
Power Factor (PF at 115 VAC) > 0.96 (at 100% load)
Power Factor (PF at 230 VAC) > 0.90 (at 100% load)
Power Factor Correction (PFC) Active PFC (Conforms to IEC/EN 61000-3-2 Class A)
No-Load Power Consumption < 5.7 W (at 115 VAC), < 4.8 W (at 230 VAC)
Mounting Style DIN Rail TS-35 (in accordance with EN 60715)
Cooling Method Free Air Convection (Natural Convection; Acoustic Noise SPL < 40 dBA at 1 m)
Overall Width (W) 85.0 mm (3.35 in)
Overall Height (H) 121.0 mm (4.76 in)
Overall Depth (D) 124.1 mm (4.89 in)
Net Weight 1.10 kg (2.43 lbs)
Termination / Connector Style Pluggable Screw Terminal Blocks (3-Pin Input & 4-Pin Output, rated 300 V / 15 A)
Input Terminal Pinout Bottom Terminal Block (3-Pin): L (Line, with internal T6.3AH fuse), N (Neutral), PE (Primary Earth / Ground)
Output & Signal Terminal Pinout Top Terminal Block (4-Pin): +V (Positive Output 1), +V (Positive Output 2), -V (Negative Return 1), -V (Negative Return 2)
Status Indicator Green LED (DC OK)
Terminal Wire Gauge Range AWG 16 to 12 (Flexible cables require ferrules; use copper wire rated >= 60 °C / 75 °C)
Enclosure / Potting Material Full Corrosion-Resistant Aluminum Casing with Conformal-Coated PCBA
Overload Protection (OLP) Threshold > 150% of rated load current
Overload Protection (OLP) Mode Hiccup Mode, Non-Latching (Auto-Recovery upon fault removal)
Overvoltage Protection (OVP) Threshold < 32 VDC ± 10% (SELV Output)
Overvoltage Protection (OVP) Mode Hiccup Mode, Non-Latching (Auto-Recovery)
Overtemperature Protection (OTP) Mode < 80 °C Surrounding Air Temperature at 100% load; Bouncing Mode, Non-Latching (Auto-Recovery)
Short Circuit Protection (SCP) Hiccup Mode, Non-Latching (Auto-Recovery when short circuit is removed)
Withstand Isolation Voltage (I/P to O/P) 4.0 kVAC
Withstand Isolation Voltage (I/P to FG / Case) 1.5 kVAC
Withstand Isolation Voltage (O/P to FG / Case) 1.5 kVAC
Earth Leakage Current < 1.0 mA (at 240 VAC)
Operating Ambient Temperature Range -25 °C to +80 °C (-13 °F to +176 °F); Cold Start at -40 °C (-40 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) for Vertical Mounting; +40 °C (+104 °F) for Horizontal Mounting
High-Temperature Derating Rate 2.5% / °C above +50 °C (Vertical Mounting); 2.5% / °C above +40 °C (Horizontal Mounting)
Low-Line Input Derating Zero derating across entire 85–264 VAC input voltage range
Altitude Derating 0 to 2,500 m (8,200 ft) operating altitude (2,000 m max for CCC compliance)
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 5% to 95% RH (Non-Condensing)
Vibration Resistance Vibration (IEC 60068-2-6): 10–500 Hz @ 3G (30 m/s²) peak, 60 min/axis (X, Y, Z); Shock (IEC 60068-2-27): 30G (300 m/s²) for 18 ms; Bump (IEC 60068-2-29): 10G for 11 ms (6,000 times total)
Ingress Protection (IP) IP20 (Install inside IP54 enclosure for ATEX / Class I Div 2 compliance)
Safety Approvals (UL / North America) UL 508 & CSA C22.2 No. 107.1-01 Listed (File E315355), UL/cUL 62368-1 & UL/cUL 60950-1 Recognized (File E191395), cCSAus Class I Div 2 Groups A, B, C, D T4 per ANSI/ISA 12.12.01:2011 & CSA C22.2 No. 213-M1987
Safety Approvals (IEC / EN / TÜV) ATEX II 3G Ex nA nC IIC T4 Gc (EN 60079-0:2009, EN 60079-15:2010, Cert. EPS 12 ATEX 1 491 X), CB Scheme IEC 62368-1 & IEC 60950-1 (SELV), SIQ Bauart EN 62368-1, EN 60204-1 (OVC III), IEC/EN 62477-1, IEC 62103
Safety Approvals (Regional / Global) CE (LVD 2014/35/EU, EMC 2014/30/EU, ATEX 2014/34/EU), UKCA, CCC (GB4943.1, GB9254, GB17625.1), BSMI (CNS 14336-1), BIS (IS 13252-1), KC (K60950-1)
EMC Conducted & Radiated Emissions CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B, KN 32, CNS 13438, EN/BS EN 61204-3
EMC Harmonic & Flicker Compliance IEC/EN/BS EN 61000-3-2 Class A (Harmonic Current), IEC/EN/BS EN 61000-3-3 (Voltage Fluctuation & Flicker)
EMC Immunity Standards EN 55024, EN 61000-6-1, EN 61000-6-2, KN 35; IEC 61000-4-2 (ESD Level 4: 15 kV Air / 8 kV Contact, Criteria A), IEC 61000-4-3 (Radiated 10 V/m, 80 MHz–1 GHz, Level 3 Criteria A), IEC 61000-4-4 (EFT 2 kV, Level 3 Criteria A), IEC 61000-4-5 (Surge Level 3: 2 kV Common Mode / 1 kV Differential Mode, Criteria A), IEC 61000-4-6 (Conducted 10 Vrms, Level 3 Criteria A), IEC 61000-4-8 (Magnetic 30 A/m, Criteria A), IEC 61000-4-11 (Voltage Dips: 100% dip for 1 cycle / 20 ms, Self-Recoverable), IEC 61000-4-12 (Ring Wave Level 3: 2 kV CM / 1 kV DM, Criteria A)
MTBF (Telcordia SR-332 / Bellcore) > 500,000 Hours (per Telcordia SR-332 at 115 VAC input, 100% load, 25 °C ambient; Expected Electrolytic Capacitor Life: 10 Years at 50% load, 40 °C)
Environmental Compliance RoHS Compliant, Conformal Coated PCBA, Pollution Degree 2

Industrial Applications & Compatible Systems

Delta DRP024V240W1BA is engineered for mission-critical 24 VDC industrial automation and hazardous location control panels requiring high transient reserve and chemical resistance:

  • Oil, Gas & Petrochemical Hazardous Locations (Class I Div 2 / ATEX Zone 2): Powers remote telemetry units (RTUs), gas analyzers, intrinsically safe barrier racks, and custody transfer skids operating in explosive gas atmospheres classified under Groups A, B, C, D T4 and ATEX IIC T4 Gc.
  • Inductive Actuator, Solenoid & Motor Starter Buses: Utilizes its 150% Power Boost (360 W / 15.0 A for 5 seconds) and 10,000 µF capacitive startup drive to energize pneumatic solenoid banks, DC contactors, and motorized valves without voltage droop.
  • Corrosive Wastewater, Marine & Chemical Processing Cabinets: Protects internal circuitry against humid, salt-laden, and chemically aggressive plant atmospheres using Delta’s full-immersion conformal PCBA coating and corrosion-resistant aluminum enclosure.
  • High-Availability Redundant PLC & DCS Control Systems: Pairs with Delta DRR-20N or DRR-20A redundancy modules in 1+1 redundant or parallel load-sharing architectures for factory automation, packaging lines, and power generation switchgear.

Installation, Thermal Management & MRO Guidelines

Follow these engineering and panel integration practices to maintain thermal reliability and safety certification compliance:

  • Convection Cooling Clearances & Thermal Derating: Maintain at least 50 mm (1.97 in) vertical clearance above and below the unit and 20 mm (0.79 in) lateral spacing in vertical TS-35 mounting (or 50 mm lateral spacing if mounted horizontally); derate continuous output power by 2.5%/°C above +50 °C vertically (+40 °C horizontally).
  • Hazardous Area Enclosure & Branch Circuit Protection: For ATEX Zone 2 and Class I, Division 2 installations, mount the supply inside an IP54-rated enclosure compliant with EN 60079-0/15, never disconnect terminals or adjust the trimmer while energized, and protect high-ampacity feeds with a minimum 8 A B-curve or 6 A C-curve circuit breaker (plus an external Neutral fuse when wired across 2 of 3 phases).
  • Redundant & Parallel Voltage Balancing: For 1+1 redundancy with a DRR-20N/20A ORing module, set the master and slave supplies within a 0.45–0.50 V differential at 50% load and account for the 0.60–0.90 V ORing drop; for direct parallel current sharing, trim both outputs within 25 mV under identical load conditions.