Description
Mean Well HLG-600H-20AB (also known as HLG600H20AB) is an industrial-grade 560W dual-mode Constant Voltage and Constant Current (CV+CC) AC-DC LED driver from the flagship HLG-600H series. Engineered with the versatile AB-Type configuration, this unit combines onboard Io and Vo potentiometer adjustability with 3-in-1 dim-to-off control (0–10VDC, 10V PWM signal, and additive resistance). Operating across a wide universal input of 90 to 305 VAC (127 to 431 VDC) with active Power Factor Correction (PF ≥ 0.98 at 115 VAC), it delivers a nominal 20 VDC output at up to 28 A across a 10 to 20 VDC constant current compliance region. Its dual-stage PFC and resonant switching topology (70 kHz main converter, 100 kHz standby) achieves up to 94.5% efficiency while maintaining tight ±0.5% line regulation, ±1.0% load regulation, and low output ripple of 150 mVp-p max.
Housed in a rugged IP65-rated Class I aluminum enclosure (Case No. 228) measuring 280 × 144 × 48.5 mm (11.02 × 5.67 × 1.91 in) and weighing 3.9 kg (8.60 lbs), the fanless design cools entirely by free air convection across a wide -40 °C to +90 °C (-40 °F to +194 °F) case temperature range. Pre-wired multi-conductor input, dual parallel 14 AWG output leads, 3-in-1 dimming leads, and an auxiliary 5 VSB @ 0.5 A standby/remote ON-OFF harness streamline field integration. Comprehensive protection circuits cover 95–108% constant-current overload limiting, short-circuit auto-recovery, and latching 22–26 V overvoltage and overtemperature shutdown. Reinforced 3.75 kVAC input-to-output galvanic isolation and compliance with UL 8750 Type HL (Class I, Division 2 hazardous locations) and EN 61347-2-13 ensure reliable operation over a >62,000-hour service life.
Key Features
- Dual-Mode CV+CC Output & AB-Type Adjustability: Delivers 20 VDC nominal at 28 A (560 W rated power) with a 10–20 V constant-current region, plus built-in potentiometers for 17–21 V voltage and 14–28 A current trimming.
- 3-in-1 Dim-to-Off Control & Remote Standby: Supports 0–10 VDC analog, 10 V PWM (100 Hz to 3 kHz), and 0–100 kΩ/N resistance dimming down to 6% minimum level with <0.5 W standby consumption at remote off.
- Wide 90–305 VAC Input & 94.5% Efficiency: Operates from 90–305 VAC (47–63 Hz) or 127–431 VDC with active PFC (PF ≥ 0.98 at 115 VAC, THD < 20%) and 94.5% peak conversion efficiency at 230/277 VAC.
- Auxiliary 5 VSB Output & Remote ON/OFF: Integrates a dedicated 5 V @ 0.5 A (±5% tolerance, 100 mVp-p max ripple) standby supply and logic-level RC+/RC- remote control leads for smart lighting controllers.
- IP65 Ruggedized Fanless Thermal Design: Extruded aluminum chassis (280 × 144 × 48.5 mm) sealed to IP65 operates from -40 °C to +90 °C Tcase (up to +55 °C full-load ambient) with 5G vibration immunity.
- Comprehensive Fault & Surge Immunity: Features auto-recovering 95–108% constant-current overload and short-circuit protection, latching 22–26 V overvoltage and overtemperature cutoffs, plus 4 kV Line-Earth / 2 kV Line-Line surge immunity.
- 3.75 kVAC Isolation & Hazardous Location Approvals: Provides 3.75 kVAC I/P-O/P, 2.0 kVAC I/P-FG, and 1.5 kVAC O/P-FG dielectric isolation, certified to UL 8750 Type HL (Class I Div 2), ENEC EN 61347-2-13, and EN 55015.
Technical Specifications
| Manufacturer | Mean Well |
|---|---|
| Manufacturer Part Number (MPN) | HLG-600H-20AB |
| Alternate Part Number | HLG600H20AB |
| Product Series | HLG-600H |
| Product Category | Dimmable LED Drivers |
| Component Type | Constant Voltage + Constant Current (CV+CC) Enclosed AC-DC LED Driver |
| Circuit Topology | Two-Stage Active PFC + Resonant Half-Bridge Switching Converter (fosc: 70 kHz Main / 100 kHz 5VSB) |
| LED Operation Mode | Constant Voltage + Constant Current (CV+CC Dual Mode) |
| Nominal Output Voltage | 20 VDC (Main Output); 5 VDC (Auxiliary Standby Output 5VSB) |
| Constant Current Region Voltage Range | 10 to 20 VDC |
| Output Voltage Adjustment Range | 17 to 21 VDC (Adjustable via built-in Vo potentiometer on AB-Type) |
| Rated Output Current | 28 A (Main 20V Output); 0.5 A (Auxiliary 5VSB Output) |
| Current Adjustment Range | 14 to 28 A (Adjustable 50%–100% via built-in Io potentiometer on AB-Type) |
| Rated Output Power | 560 W |
| Output Ripple & Noise (Max.) | 150 mVp-p (20V Main Output); 100 mVp-p (5VSB Output, measured at 20 MHz BW) |
| Output Voltage Tolerance | ±1.5% (Main Output); ±5.0% (5VSB Output) |
| Line Regulation | ±0.5% |
| Load Regulation | ±1.0% |
| Setup Time | 500 ms (at 115 / 230 VAC full load, cold start) |
| Rise Time | 80 ms (at 115 / 230 VAC full load) |
| Hold-Up Time (at 115 VAC) | 15 ms (Typ. at 115 / 230 VAC full load) |
| Hold-Up Time (at 230 VAC) | 15 ms (Typ. at 230 VAC full load) |
| AC Input Voltage Range | 90 to 305 VAC |
| DC Input Voltage Range | 127 to 431 VDC |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency (at 230 VAC) | 94.5% (Typ. at 230 VAC and 277 VAC full load) |
| AC Input Current (at 115 VAC) | 7.0 A (Typ.) |
| AC Input Current (at 230 VAC) | 3.3 A at 230 VAC; 2.9 A at 277 VAC (Typ.) |
| Inrush Current (Cold Start at 230 VAC) | 70 A (twidth = 1000 µs measured at 50% Ipeak at 230 VAC, per NEMA 410; Max. 1 unit on 16A Type B or 2 units on 16A Type C MCB) |
| Power Factor (PF at 115 VAC) | ≥ 0.98 (at full load) |
| Power Factor (PF at 230 VAC) | ≥ 0.95 at 230 VAC; ≥ 0.93 at 277 VAC (at full load) |
| Power Factor Correction (PFC) | Built-in Active PFC (THD < 20% at ≥ 50% load for 115/230 VAC, ≥ 75% load for 277 VAC) |
| No-Load Power Consumption | < 0.5 W (Standby power consumption at Remote OFF) |
| Switching Frequency | 70 kHz (Main 12V–54V Power Stage); 100 kHz (5VSB Stage) |
| Mounting Style | Chassis / Baseplate Flange Mount (4 × Ø4.5 mm mounting slots) |
| Cooling Method | Free Air Convection (Fanless) |
| Enclosure Case Number | 228 |
| Overall Width (W) | 144.0 mm (5.67 in) |
| Overall Height (H) | 48.5 mm (1.91 in) |
| Overall Depth (D) | 280.0 mm (11.02 in) |
| Dimensional Tolerance | ±1.0 mm (±0.04 in) |
| Mounting Hole Pitch | 253.2 × 126.6 mm (9.97 × 4.98 in) Primary Flange; 97.0 mm (3.82 in) Secondary Center |
| Net Weight | 3.9 kg (8.60 lbs) |
| Termination / Connector Style | Pre-wired Weatherproof Multi-Core Flying Cable Leads |
| Input Terminal Pinout | Input Cable (SJOW 17AWG×3C & H05RN-F 3×1.0mm²): AC/L (Brown), AC/N (Blue), FG (Green/Yellow) |
| Output & Signal Terminal Pinout | Main Output (2 × SJTW 14AWG×2C in parallel): +V (Red), -V (Black); Control Harness (UL2517 22AWG×3C): RC+ (Brown), RC- & GND (Black), +5VSB (Yellow); Dimming Harness (UL2517 18AWG×2C): DIM+ (Purple), DIM- (Pink) |
| Control & Monitoring Signals | Remote ON/OFF Control (Power ON: >2 to 5 VDC or Open Circuit; Power OFF: <0 to 0.5 VDC or Short Circuit) + 5VSB (5V @ 0.5A) |
| Dimming Control Interface | Built-in 3-in-1 Dimming (0–10 VDC Analog, 10V PWM at 100 Hz–3 kHz, or 0–100 kΩ/N Additive Resistance; 100 µA typ. source current; ~6% min. dimming level; Dim-to-Off supported) + Built-in Io/Vo Potentiometers |
| Lead Wire Length | 300 ± 20 mm (11.81 ± 0.79 in) for AC Input, DC Output, and RC/5VSB Leads; 350 ± 20 mm (13.78 ± 0.79 in) for DIM+/DIM- Leads |
| Enclosure / Potting Material | Extruded Aluminum Metal Housing (Class I Design) with Internal Silicone/Epoxy Thermal Potting |
| Overload Protection (OLP) Threshold | 95% to 108% of rated output current |
| Overload Protection (OLP) Mode | Constant Current Limiting, recovers automatically after fault condition is removed |
| Overvoltage Protection (OVP) Threshold | 22 to 26 VDC |
| Overvoltage Protection (OVP) Mode | Shut down output voltage, re-power on to recover (Latch-off) |
| Overtemperature Protection (OTP) Mode | Shut down output voltage, re-power on to recover (Latch-off) |
| Short Circuit Protection (SCP) | Constant Current Limiting, recovers automatically after fault condition is removed |
| Withstand Isolation Voltage (I/P to O/P) | 3.75 kVAC (3750 VAC) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2.0 kVAC (2000 VAC) |
| Withstand Isolation Voltage (O/P to FG / Case) | 1.5 kVAC (1500 VAC) |
| Isolation Resistance (at 500 VDC) | ≥ 100 MΩ at 500 VDC, 25 °C, 70% RH (I/P-O/P, I/P-FG, O/P-FG) |
| Earth Leakage Current | < 0.75 mA at 277 VAC |
| Operating Ambient Temperature Range | -40 °C to +90 °C (-40 °F to +194 °F) Case Temperature (Tcase); -40 °C to +70 °C (-40 °F to +158 °F) Ambient Temperature (Ta) |
| Full-Load Operating Temperature Limit | +55 °C (+131 °F) Max. Ambient Temperature (Ta) at 100% load in Constant Current Mode; +75 °C (+167 °F) Max. Case Temperature (Tcase) at 100% load |
| High-Temperature Derating Rate | Linearly derates from 100% load at +55 °C Ta (+75 °C Tcase) to 50% load at +70 °C Ta (+90 °C Tcase) in horizontal mounting |
| Low-Line Input Derating | Derates linearly from 100% load at 115 VAC down to 80% load at 90 VAC input (at 60 Hz) |
| Altitude Derating | 3.5 °C per 1000 m (3280 ft) for operating altitudes above 2000 m (6560 ft) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 20% to 95% RH (Non-condensing) |
| Storage Relative Humidity | 10% to 95% RH (Non-condensing) |
| Temperature Coefficient | ±0.03% / °C (0 to 55 °C) |
| Vibration Resistance | 10 to 500 Hz, 5G, 12 min/cycle, 72 min each along X, Y, Z axes |
| Ingress Protection (IP) | IP65 (Dust-tight and water-jet protected with onboard Io/Vo access ports) |
| Safety Approvals (UL / North America) | UL 60950-1, UL 8750 (Type ‘HL’ for Class I, Division 2 Hazardous Locations), CSA C22.2 No. 250.13-12 |
| Safety Approvals (IEC / EN / TÜV) | ENEC BS EN/EN 61347-1, BS EN/EN 61347-2-13 Independent, BS EN/EN 62384 |
| Safety Approvals (Regional / Global) | PSE J61347-1 / J61347-2-13, GB/T 19510.1 / GB/T 19510.213 (Optional CCC), EAC TP TC 004, AS/NZS 60950.1 (by CB), CE, UKCA |
| EMC Conducted & Radiated Emissions | BS EN/EN 55015, EAC TP TC 020, GB/T 17743, KS C 9815, KS C 9547 |
| EMC Harmonic & Flicker Compliance | BS EN/EN 61000-3-2 Class C (at ≥ 50% load), BS EN/EN 61000-3-3, GB 17625.1 |
| EMC Immunity Standards | BS EN/EN 61547, BS EN/EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5 (Light Industry Level: 4 kV Line-Earth / 2 kV Line-Line Surge), EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 |
| MTBF (Telcordia SR-332 / Bellcore) | 913,400 hours min. (at 25 °C); Typical Lifetime > 62,000 hours at Tcase ≤ 75 °C |
| MTBF (MIL-HDBK-217F) | 76,900 hours min. (at 25 °C) |
| Environmental Compliance | RoHS, REACH, 7-Year Manufacturer Warranty |
Industrial Applications & Compatible Systems
The Mean Well HLG-600H-20AB is engineered for high-power, low-voltage industrial and outdoor solid-state lighting installations requiring dual-mode current/voltage regulation and remote dimming flexibility:
- High-Bay Industrial & Warehouse Luminaires: Drives high-current 20 VDC LED arrays and COB modules in manufacturing bays, logistics hubs, and heavy industrial plants with 0–10V or PWM daylight harvesting.
- Commercial Horticultural & Greenhouse Lighting: Powers multi-bar LED grow fixtures in humid greenhouse environments where IP65 sealing, onboard Io/Vo current trimming, and synchronized resistance dimming optimize photosynthetic photon flux.
- Marine Fishing Lamps & Outdoor Floodlighting: Delivers 28 A continuous output with 5G vibration resistance and 4 kV common-mode surge protection for coastal stadium masts, parking lot floodlights, and commercial fishing vessels.
- Class I, Division 2 Hazardous Location Fixtures: Certified to UL 8750 Type HL (when built into suitable final equipment enclosures) for petrochemical refineries, grain silos, and industrial paint booths.
Installation, Thermal Management & MRO Guidelines
To ensure >62,000-hour operational reliability and full safety compliance, observe the following engineering and MRO installation practices:
- Dual Parallel Output Lead Wiring & Dimming Isolation: Connect both sets of 14 AWG output cables (+V Red and -V Black) in parallel to distribute the 28 A load evenly, and never short or tie DIM- (Pink) to -V (Black) as this will damage the internal dimming circuit.
- Upstream Circuit Breaker Sizing for 70 A Inrush: Account for the 70 A (1000 µs) cold-start inrush pulse at 230 VAC by limiting each 16 A Type B miniature circuit breaker to 1 driver maximum, or using a 16 A Type C breaker for up to 2 drivers.
- Thermal Case Point (tc) & Low-Line Derating: Maintain the central case temperature (tc point) at or below +75 °C (+55 °C max ambient at full load) to achieve the >62,000-hour rated lifetime, and derate output load to 80% when operating at 90 VAC input.