Description
Mean Well HLG-240H-36AB (also known as HLG240H36AB) is an industrial-grade 241.2W dual-mode Constant Voltage and Constant Current (CV+CC) LED driver from the flagship HLG-240H series. In Mean Well’s nomenclature, 36 denotes the 36 VDC nominal output channel, while the AB suffix specifies the hybrid functional configuration combining built-in Vo/Io potentiometers (A-Type) with an isolated 3-in-1 dimming cable (B-Type) in an IP65-rated enclosure. Operating across an ultra-wide 90 to 305 VAC (or 127 to 431 VDC) input range with active power factor correction (PF ≥ 0.98 at 115 VAC) and a 100 kHz switching topology, it delivers up to 6.7 A across an 18 to 36 VDC constant-current compliance window. High conversion efficiency of 92.5% pairs with tight ±1.0% voltage tolerance, ±0.5% line and load regulation, and a low maximum output ripple of 250 mVp-p.
Housed in a rugged extruded aluminum Case No. 994C chassis measuring 244.2 × 68.0 × 38.8 mm (9.61 × 2.68 × 1.53 in) and weighing 1.3 kg (2.87 lbs), the unit relies on silent fanless free-air convection across a -40 °C to +90 °C (-40 °F to +194 °F) case temperature range. Pre-wired 300 mm rubberized leads provide color-coded AC input, DC output, and 1–10 VDC / 10V PWM / 100kΩ resistance dimming connections alongside accessible external potentiometers for fine-tuning voltage (33.5–38.5 VDC) and current (3.3–6.7 A). Comprehensive fault protection includes 95–108% constant-current limiting, hiccup short-circuit recovery, auto-recovering overtemperature shutdown, and latching overvoltage protection at 43–49 VDC. Reinforced 3.75 kVAC primary-to-secondary galvanic isolation, 4 kV line-to-earth surge immunity, and UL 8750 Type HL hazardous-location approvals ensure long-term reliability exceeding 62,000 hours.
Key Features
- Dual-Mode CV+CC Output & Potentiometer Trimming: Delivers 36 VDC nominal at 6.7 A (241.2 W) with an 18 to 36 VDC constant-current region, plus on-chassis potentiometers to trim output voltage (33.5–38.5 VDC) and current (3.3–6.7 A).
- Integrated 3-in-1 Dimming Control Interface: Supports smooth constant-current dimming from 10% to 100% via dedicatedDIM+/DIM- leads using additive 1–10 VDC voltage, 10V PWM signals (100 Hz to 3 kHz), or 10kΩ–100kΩ/N resistance.
- Wide 90–305 VAC Universal Input & Active PFC: Accepts 90 to 305 VAC (47–63 Hz) or 127 to 431 VDC line power, achieving PF ≥ 0.98 at 115 VAC, PF ≥ 0.95 at 230 VAC, and THD below 20%.
- 92.5% High Efficiency & Fanless Thermal Design: Achieves 92.5% typical efficiency in a potted Case 994C metal enclosure, operating under natural convection up to a +90 °C (+194 °F) maximum case temperature.
- IP65 Ingress Protection & 5G Vibration Immunity: Sealed aluminum housing with weather-resistant SJOW/H05RN-F rubber cables protects against dust and water jets while withstanding 5G vibration from 10 to 500 Hz across all axes.
- Comprehensive Protection & Latching OVP Suite: Features 95–108% constant-current overload limiting, auto-recovering hiccup short-circuit protection, thermal shutdown, and latching overvoltage shutdown triggered between 43 and 49 VDC.
- 3.75 kVAC SELV Isolation & 4 kV Surge Immunity: Engineered with 3.75 kVAC I/P-to-O/P, 2.0 kVAC I/P-to-FG, and 1.5 kVAC O/P-to-FG dielectric strength alongside EN 61000-4-5 4 kV line-to-earth and 2 kV line-to-line surge immunity.
- UL 8750 Type HL & Global Lighting Compliance: Certified to UL 8750 Type HL for Class I Division 2 hazardous locations, UL 1012, EN 61347-1/-2-13, and EN 55015 Class B emissions with a 7-year OEM warranty.
Technical Specifications
| Manufacturer | Mean Well |
|---|---|
| Manufacturer Part Number (MPN) | HLG-240H-36AB |
| Alternate Part Number | HLG240H36AB |
| Product Series | HLG-240H Series |
| Product Category | Dimmable LED Drivers |
| Component Type | AC-DC Constant Voltage + Constant Current (CV+CC) Dimmable LED Driver |
| Circuit Topology | Two-Stage Active PFC + Isolated Switching Converter (SELV, Class I) |
| LED Operation Mode | Constant Voltage + Constant Current (CV + CC Dual Mode) |
| Nominal Output Voltage | 36 VDC |
| Constant Current Region Voltage Range | 18 to 36 VDC |
| Output Voltage Adjustment Range | 33.5 to 38.5 VDC (via built-in Vo ADJ. potentiometer) |
| Rated Output Current | 6.7 A |
| Current Adjustment Range | 3.3 to 6.7 A via built-in Io ADJ. potentiometer; 10% to 100% via 3-in-1 dimming |
| Rated Output Power | 241.2 W |
| Output Ripple & Noise (Max.) | 250 mVp-p (measured at 20 MHz bandwidth with 0.1 µF & 47 µF parallel capacitor) |
| Output Voltage Tolerance | ±1.0% (includes set-up tolerance, line regulation, and load regulation) |
| Line Regulation | ±0.5% |
| Load Regulation | ±0.5% |
| Setup Time (at 115 VAC) | 1000 ms (at cold start, full load) |
| Setup Time (at 230 VAC) | 500 ms (at cold start, full load) |
| Rise Time | 80 ms (at 115 / 230 VAC full load) |
| Hold-Up Time | 15 ms (typ. at full load, 115 / 230 VAC) |
| AC Input Voltage Range | 90 to 305 VAC (Universal / 277 VAC North American commercial lighting) |
| DC Input Voltage Range | 127 to 431 VDC |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency | 92.5% (typ. at 230 VAC full load) |
| AC Input Current (at 115 VAC) | 4.0 A (typ.) |
| AC Input Current (at 230 VAC) | 2.0 A (typ. at 230 VAC) / 1.2 A (typ. at 277 VAC) |
| Inrush Current (Cold Start at 230 VAC) | 75 A (twidth = 570 µs measured at 50% Ipeak at 230 VAC, per NEMA 410; max. 2 units on 16 A Type B / 4 units on Type C MCB) |
| Power Factor (PF at 115 VAC) | ≥ 0.98 (at full load) |
| Power Factor (PF at 230 VAC) | ≥ 0.95 (at full load) |
| Power Factor Correction (PFC) | Active PFC; Total Harmonic Distortion (THD) < 20% (at load ≥ 50% for 115/230 VAC; ≥ 75% for 277 VAC) |
| Switching Frequency | 100 kHz (fixed PWM & PFC oscillator) |
| Mounting Style | Chassis / Surface Mount (4 × Ø4.2 mm mounting slots) |
| Cooling Method | Free Air Convection (Fanless) |
| Enclosure Case Number | 994C |
| Overall Width (W) | 68.0 mm (2.68 in) |
| Overall Height (H) | 38.8 mm (1.53 in) |
| Overall Depth (D) | 244.2 mm (9.61 in) |
| Dimensional Tolerance | ±1.0 mm (±0.04 in) |
| Mounting Hole Pitch | 220.2 × 34.0 / 34.2 mm (8.67 × 1.34 / 1.35 in) center-to-center |
| Net Weight | 1.30 kg (2.87 lbs / 45.86 oz) |
| Termination / Connector Style | Pre-Wired Flying Cable Leads + Built-In Vo/Io Potentiometers under Rubber Stoppers |
| Input Terminal Pinout | Input Cable (SJOW 17AWG & H05RN-F 1.0 mm² × 3C): AC/L (Brown), AC/N (Blue), FG Protective Earth (Green/Yellow) |
| Output & Signal Terminal Pinout | DC Output Cable (SJOW 17AWG & H05RN-F 1.0 mm² × 2C): +V (Red), -V (Black); Dimming Cable (UL2517 20AWG × 2C): DIM+ (Purple), DIM- (Pink) |
| Dimming Control Interface | 3-in-1 Dimming: 1 to 10 VDC Additive Voltage, 10V PWM Signal (100 Hz to 3 kHz), or 10 kΩ to 100 kΩ/N Resistance (100 µA typ. source current) |
| Lead Wire Length | 300 ± 20 mm (11.81 ± 0.79 in) for AC Input, DC Output, and Dimming Cables |
| Enclosure / Potting Material | Extruded Aluminum Metal Housing (Class I Design), Fully Potted Internal Electronics |
| Overload Protection (OLP) Threshold | 95% to 108% of rated output power |
| Overload Protection (OLP) Mode | Constant Current Limiting, recovers automatically after fault condition is removed |
| Overvoltage Protection (OVP) Threshold | 43 to 49 VDC |
| Overvoltage Protection (OVP) Mode | Shut down and latch off output voltage, re-power on to recover |
| Overtemperature Protection (OTP) Mode | Shut down output voltage, recovers automatically after temperature goes down |
| Short Circuit Protection (SCP) | Hiccup mode, recovers automatically after fault condition is removed |
| Withstand Isolation Voltage (I/P to O/P) | 3.75 kVAC (3750 VAC) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2.0 kVAC (2000 VAC) |
| Withstand Isolation Voltage (O/P to FG / Case) | 1.5 kVAC (1500 VAC) |
| Isolation Resistance (at 500 VDC) | ≥ 100 MΩ (I/P to O/P, I/P to FG, O/P to FG at 500 VDC, 25 °C, 70% RH) |
| Earth Leakage Current | < 0.75 mA (at 277 VAC) |
| Operating Ambient Temperature Range | Tcase: -40 °C to +90 °C (-40 °F to +194 °F); Typical Ambient Ta: -40 °C to +70 °C (-40 °F to +158 °F) |
| Full-Load Operating Temperature Limit | 100% load up to Tcase +75 °C (+167 °F) or Ta +60 °C (+140 °F) at 230 VAC; 100% load up to Tcase +65 °C (+149 °F) or Ta +50 °C (+122 °F) at 100 VAC |
| High-Temperature Derating Rate | Derates linearly from 100% load at Tcase +75 °C (+167 °F) to 50% load at Tcase +90 °C (+194 °F) at 230 VAC |
| Low-Line Input Derating | Derates linearly from 100% load at 100 VAC down to 80% load at 90 VAC input |
| Altitude Derating | 3.5 °C per 1000 m (3280 ft) for operating altitudes above 2000 m (6560 ft) |
| Storage Temperature Range | -40 °C to +80 °C (-40 °F to +176 °F) |
| Operating Relative Humidity | 20% to 95% RH (non-condensing) |
| Storage Relative Humidity | 10% to 95% RH |
| Temperature Coefficient | ±0.03% / °C (0 °C to 50 °C / +32 °F to +122 °F) |
| Vibration Resistance | 10 to 500 Hz, 5G, 12 min/cycle, 72 min each along X, Y, and Z axes |
| Ingress Protection (IP) | IP65 (Dust-tight and protected against water jets for indoor or outdoor installations) |
| Safety Approvals (UL / North America) | UL 8750 Type “HL” (Class I, Division 2 Hazardous Locations), UL 1012, CAN/CSA-C22.2 No. 107.1-01, CSA C22.2 No. 250.0-08 |
| Safety Approvals (IEC / EN / TÜV) | BS EN / EN / AS/NZS 61347-1, BS EN / EN / AS/NZS 61347-2-13 Independent, SELV |
| Safety Approvals (Regional / Global) | PSE J61347-1 / J61347-2-13, GB/T 19510.1 / 19510.213 (CCC), EAC TP TC 004, CE, UKCA |
| EMC Conducted & Radiated Emissions | BS EN / EN 55015, BS EN / EN 55032 (CISPR 32) Class B, GB/T 17743, EAC TP TC 020 |
| EMC Harmonic & Flicker Compliance | BS EN / EN 61000-3-2 Class C (at load ≥ 50%), BS EN / EN 61000-3-3, GB 17625.1 |
| EMC Immunity Standards | BS EN / EN 61000-4-2, -3, -4, -5 (Surge: 4 kV Line-Earth, 2 kV Line-Line), -6, -8, -11, BS EN / EN 61547, BS EN / EN 55024 (Light Industry Level) |
| MTBF (Telcordia SR-332 / Bellcore) | 2,015,100 hours min. (2015.1K hrs) |
| MTBF (MIL-HDBK-217F) | 176,400 hours min. (176.4K hrs at 25 °C) |
| Environmental Compliance | RoHS Compliant, ErP Lighting Directive Ready, Typical Lifetime > 62,000 Hours (at Tcase ≤ 75 °C), 7-Year Manufacturer Warranty |
Industrial Applications & Compatible Systems
Mean Well HLG-240H-36AB is engineered for rugged commercial, industrial, and hazardous-location LED lighting installations requiring both local current calibration and remote dimming control:
- High-Bay Industrial & Warehouse Luminaires: Powers 240W-class 36 VDC LED arrays in manufacturing plants, logistics distribution centers, and cold-storage facilities operating on 120V, 208V, 240V, or 277V branch circuits.
- Outdoor Street, Tunnel & Parking Structure Lighting: Provides IP65 weather-sealed power with 4 kV line-to-earth surge immunity and -40 °C cold-start capability for municipal roadways, highway overpasses, and multi-deck parking garages.
- Horticultural Greenhouse & Commercial Fishing Lamps: Enables precise photosynthetic photon flux density (PPFD) tuning via both on-body Io/Vo potentiometers and centralized 1–10V / PWM climate controllers in high-humidity agricultural and marine environments.
- Class I Division 2 Hazardous Location Fixtures: Carries UL 8750 Type HL approval for integration into enclosed vapor-tight luminaires deployed across petrochemical processing zones, paint booths, and grain handling facilities.
Installation, Thermal Management & MRO Guidelines
Follow these critical field engineering practices during installation, dimming integration, and preventive MRO replacement:
- Dimming Polarity Isolation & Zero-Brightness Switching: Never connect the pink DIM- wire to the black -V DC output negative, as doing so damages the internal 100 µA dimming current source; because 3-in-1 dimming scales down to a 10% minimum threshold, install an upstream AC relay and switch on the mains input whenever complete 0% dark turn-off is required.
- Thermal Case Point (tc) Monitoring & Low-Line Derating: Verify that the central enclosure tc measurement point remains at or below +75 °C (+167 °F) to achieve the rated >62,000-hour service life, and apply a 20% load derating whenever AC line voltage drops between 100 VAC and 90 VAC.
- Inrush Breaker Sizing & Waterproof Splice Protection: Account for the 75 A (570 µs) cold-start inrush pulse by limiting each 230 VAC 16 A circuit breaker to a maximum of 2 drivers on Type B or 4 drivers on Type C MCBs, and seal field cable splices using IP68-rated M12/M15 waterproof connectors or Mean Well CJ04 cable joiners.