Description
TDK-Lambda VS150E-12 (also known as VS150E12) is an industrial single-output open-frame AC-DC switching power supply from the miniaturized VS-E Series, engineered with a 30% footprint reduction compared to legacy VS models. Decoding the OEM nomenclature, VS150E specifies the 150W high-efficiency series, -12 denotes the 12 VDC nominal output, and the blank suffix indicates the standard open-frame PCB construction without a cover or L-bracket. Operating from a dedicated low-line input range of 85 to 132 VAC (47 to 63 Hz) or 110 to 175 VDC, this unit delivers up to 12.5 A continuous output current (150.0 W rated power) with an onboard potentiometer (VR51) permitting fine voltage adjustment between 10.8 and 13.2 VDC. Its high-efficiency switching topology achieves 87% typical efficiency at 100 VAC while maintaining tight 48 mV max line regulation, 96 mV max load regulation, and low output ripple and noise of 150 mVp-p across 0°C to +70°C.
Constructed on a compact open-frame PCB measuring 75 x 34 x 160 mm (2.95 x 1.34 x 6.30 in) and weighing 390 g (13.76 oz), the VS150E-12 utilizes industry-standard JST VH-series board-to-wire headers: a 3-pin input header (CN1: B3P5-VH) and dual output headers (CN51: B6P-VH for +V and CN52: B7P-VH for -V). Comprehensive onboard protection includes constant current limit overload protection (13.12 A threshold) with automatic recovery and latching overvoltage protection (13.8 to 16.2 VDC) requiring manual AC power cycling. The power supply provides 2,000 VAC input-to-output and input-to-ground isolation alongside 500 VAC output-to-ground isolation, supporting 100% convection-cooled load up to +50°C (+122°F) and operation from -10°C to +70°C (+14°F to +158°F). It holds full certification to UL/CSA/EN 62368-1 and EN 50178 (OV II), while meeting EN 55011 / EN 55032 Class B, FCC Class B, and VCCI Class B EMI benchmarks.
Key Features
- High-Density 150W Output Delivery: Supplies a tightly regulated 12 VDC nominal output at up to 12.5 A continuous current (150.0 W rated power), with an onboard VR51 potentiometer offering a ±10% adjustment span from 10.8 to 13.2 VDC.
- Dedicated 100VAC/115VAC Low-Line Input: Optimized for North American, Japanese, and industrial control transformer power buses, accepting 85 to 132 VAC (47 to 63 Hz) or 110 to 175 VDC with a 3.2 A typical input draw.
- 87% Conversion Efficiency & Low Ripple: Achieves 87% typical efficiency at 100 VAC full load with active inrush current suppression (30 A cold start) and limits output ripple and noise to 150 mVp-p (0°C to +70°C).
- Precision Line & Load Regulation: Maintains exceptional voltage stability across fluctuating mains and dynamic industrial loads, featuring 48 mV maximum line regulation, 96 mV maximum load regulation, and a 20 ms typical hold-up time.
- 30% Miniaturized Open-Frame Footprint: Engineered in a low-profile 75 x 34 x 160 mm (2.95 x 1.34 x 6.30 in) open-frame PCB form factor weighing 390 g, utilizing four Ø3.5 mm mounting holes on a 65 x 150 mm pitch.
- JST VH-Series Multi-Pin Termination: Equipped with a JST B3P5-VH(LF)(SN) input header (CN1) and split high-current output headers—JST B6P-VH (CN51, +V) and B7P-VH (CN52, -V)—rated for up to 5 A per terminal pin.
- Constant Current OLP & Latching OVP: Safeguards downstream electronics via constant current limit overload protection triggering above 13.12 A with automatic recovery, paired with manual-reset shutdown overvoltage protection engaging between 13.8 and 16.2 VDC.
- 2kVAC Isolation & Global Safety Compliance: Features 2,000 VAC input-to-output and input-to-ground dielectric strength, UL/CSA/EN 62368-1 and EN 50178 Overvoltage Category II approvals, and Class B conducted/radiated EMI performance.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | VS150E-12 |
| Alternate Part Number | VS150E12 |
| Product Series | VS-E Series (VS150E) |
| Product Category | Open Frame PSUs |
| Component Type | Open-Frame AC-DC Switching Power Supply |
| Circuit Topology | Switched-Mode Power Supply (SMPS) with Inrush Current Suppressor |
| Nominal Output Voltage | 12 VDC |
| Output Voltage Adjustment Range | 10.8 to 13.2 VDC (±10% via onboard potentiometer VR51) |
| Rated Output Current | 12.5 A |
| Output Current Range | 0 to 12.5 A |
| Rated Output Power | 150.0 W |
| Number of Outputs | 1 (Single Output; Series Operation Possible, Parallel Operation Not Supported) |
| Output Ripple & Noise (Max.) | 150 mVp-p (at 0 °C to +70 °C); 180 mVp-p (at -10 °C to 0 °C) |
| Line Regulation | 48 mV max. (85 to 132 VAC, constant load) |
| Load Regulation | 96 mV max. (No load to full load, constant input voltage) |
| Hold-Up Time (at 115 VAC) | 20 ms typ. (measured at 100 VAC, Ta = 25 °C, nominal output and maximum power) |
| AC Input Voltage Range | 85 to 132 VAC (Safety agency rated range: 100 to 120 VAC) |
| DC Input Voltage Range | 110 to 175 VDC |
| Nominal Input Voltage | 100 to 120 VAC |
| Input Frequency Range | 47 to 63 Hz (50 / 60 Hz nominal) |
| Efficiency (at 115 VAC) | 87% typ. (at 100 VAC, Ta = 25 °C, full load) |
| AC Input Current (at 115 VAC) | 3.2 A typ. (at 100 VAC, full load) |
| Inrush Current (Cold Start at 115 VAC) | 30 A typ. (at 100 VAC cold start, active inrush suppressor circuit) |
| Mounting Style | Chassis / Standoff Mount (Open-Frame PCB with 4 x Ø3.5 mm mounting holes) |
| Cooling Method | Natural Free Air Convection |
| Package / Footprint Standard | Open-Frame PCB Type (Lead cut less than 3 mm on solder side) |
| Overall Width (W) | 75 mm (2.95 in) |
| Overall Height (H) | 34 mm (1.34 in) |
| Overall Depth (D) | 160 mm (6.30 in) |
| Dimensional Tolerance | ±1 mm (±0.039 in) outer dimensions; ±0.5 mm (±0.020 in) mounting pitch |
| Mounting Hole Pitch | 65 x 150 mm (2.56 x 5.91 in) with 5 mm edge offset |
| Net Weight | 390 g (0.86 lbs / 13.76 oz) typ. |
| Termination / Connector Style | JST VH-Series 3.96 mm Pitch Board-to-Wire Pin Headers (Mating sockets VHR-5N, VHR-6N, VHR-7N and SVH-21T-P1.1 / BVH-21T-P1.1 crimp pins sold separately) |
| Input Terminal Pinout | CN1 (JST B3P5-VH(LF)(SN)): Pin 1 = AC Line (L), Pin 3 = AC Neutral (N), Pin 5 = Frame Ground (FG) [Pins 2 & 4 removed for creepage; Mates with VHR-5N / Harness HA-2-IN] |
| Output & Signal Terminal Pinout | CN51 (JST B6P-VH(LF)(SN)): Pins 1 to 6 = +V DC Output (Mates with VHR-6N / Harness HA-6-OU); CN52 (JST B7P-VH(LF)(SN)): Pins 1 to 7 = -V DC Return (Mates with VHR-7N / Harness HA-7-OU) [Max. 5 A per connector pin] |
| Overload Protection (OLP) Threshold | 13.12 A min. (>105% of rated output current) |
| Overload Protection (OLP) Mode | Constant current limit with automatic recovery (Avoid overload or short-circuit operation exceeding 30 seconds) |
| Overvoltage Protection (OVP) Threshold | 13.8 to 16.2 VDC (115% to 135% of nominal output voltage) |
| Overvoltage Protection (OVP) Mode | Output shutdown Latch-Off mode; requires manual reset (AC input re-power on) |
| Short Circuit Protection (SCP) | Constant current limit with automatic recovery (Max. 30 seconds continuous duration) |
| Withstand Isolation Voltage (I/P to O/P) | 2,000 VAC (10 mA cutoff) for 1 minute |
| Withstand Isolation Voltage (I/P to FG / Case) | 2,000 VAC (10 mA cutoff) for 1 minute |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VAC (20 mA cutoff) for 1 minute |
| Isolation Resistance (at 500 VDC) | >100 MΩ (Output to FG at 500 VDC, 25 °C, 70% RH) |
| Earth Leakage Current | <0.5 mA (at 60 Hz, Ta = 25 °C per UL, CSA, EN, and DENAN test methods) |
| Operating Ambient Temperature Range | -10 °C to +70 °C (+14 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% load (Standard Vertical Mounting A); +40 °C (+104 °F) at 100% load (Mountings B, C, D, E) |
| High-Temperature Derating Rate | Mounting A: Derates linearly from 100% load at +50 °C to 70% at +60 °C (3.0%/°C) and 20% at +70 °C (5.0%/°C) |
| Storage Temperature Range | -30 °C to +85 °C (-22 °F to +185 °F) |
| Operating Relative Humidity | 30% to 90% RH (Non-condensing / No dewdrop) |
| Storage Relative Humidity | 10% to 95% RH (Non-condensing / No dewdrop) |
| Temperature Coefficient | <0.02% / °C |
| Vibration Resistance | 10 to 55 Hz, 19.6 m/s² (2G) constant sweep for 1 min, 1 hour each along X, Y, and Z axes (non-operating); Shock: <196.1 m/s² (20G) |
| Safety Approvals (UL / North America) | UL 62368-1, CSA C22.2 No. 62368-1 (cULus), UL 60950-1, CSA 60950-1 |
| Safety Approvals (IEC / EN / TÜV) | EN 62368-1, EN 50178 (Overvoltage Category II), EN 60950-1 (TÜV), Low Voltage Directive |
| Safety Approvals (Regional / Global) | Designed to meet Japan DENAN Electrical Appliance and Material Safety Law Appendix 12 (J60950-1 at 100 VAC) |
| EMC Conducted & Radiated Emissions | Designed to meet EN 55011 / EN 55032 Class B, FCC Part 15 Class B, VCCI Class B |
| EMC Immunity Standards | Designed to meet IEC 61000-4-2 (ESD Level 2, 3), IEC 61000-4-3 (RF Radiated Level 3), IEC 61000-4-4 (EFT/Burst Level 3), IEC 61000-4-5 (Surge Level 2, 3), IEC 61000-4-6 (Conducted RF Level 3), IEC 61000-4-8 (Power Frequency Magnetic Field Level 4), IEC 61000-4-11 (Voltage Dips & Interruptions) |
| Environmental Compliance | RoHS Directive Compliant (5-Year OEM Conditional Warranty) |
Industrial Applications & Compatible Systems
The TDK-Lambda VS150E-12 is built for embedded industrial, automation, and OEM machinery requiring a high-reliability 12 VDC power rail within a compact open-frame footprint:
- Semiconductor & Factory Automation Equipment: Powers 12 VDC PLC I/O racks, pneumatic solenoid manifolds, optical inspection sensors, and embedded motion controllers operating off 100–120 VAC control transformers.
- Test, Measurement & Laboratory Instrumentation: Provides a low-noise (<150 mVp-p), tightly regulated 12 VDC bus for benchtop analyzers, data acquisition chasses, and automated test equipment (ATE).
- Commercial Kiosks, Gaming & Ticketing Terminals: Fits inside space-constrained enclosures for bill validators, thermal receipt printers, card readers, and interactive display logic boards.
- Broadcast, Telecom & Optical Network Subsystems: Supplies reliable 150W DC power with 20 ms hold-up time for rack-mounted signal transceivers, industrial routers, and security access panels.
Installation, Thermal Management & MRO Guidelines
Follow these critical mechanical and electrical integration practices to ensure optimal thermal derating and connector longevity:
- Multi-Pin Current Sharing (5A Per Pin Limit): Each JST VH terminal pin on CN51 (+V, 6 pins) and CN52 (-V, 7 pins) is rated for a strict maximum of 5 A; to safely carry the full 12.5 A output, distribute the load across at least 3 to 4 parallel pins using JST VHR-6N / VHR-7N housings and SVH-21T-P1.1 crimp terminals.
- Mounting Orientation & Thermal Derating: Install in Standard Vertical Orientation (Mounting A) to achieve 100% load (12.5 A) up to +50 °C, derating to 70% at +60 °C and 20% at +70 °C; for horizontal or alternative orientations (Mountings B–E), derating begins at +40 °C.
- Input Voltage Verification & Overload Duration: Verify that the AC supply mains do not exceed 132 VAC (85–132 VAC / 110–175 VDC dedicated low-line input) and avoid sustaining an output short-circuit or overload condition (>13.12 A) for more than 30 continuous seconds.
- Chassis Standoff Clearance & Grounding: Mount the PCB using all four Ø3.5 mm corner holes on a 65 x 150 mm pattern with minimum 5 mm creepage clearance to metal surfaces, and bond the tapped mounting hole / CN1 Pin 5 (FG) to the protective earth chassis for Class B EMI suppression.