Description
TDK-Lambda JWT75-525/RA (also known as JWT75525RA) is a 75W triple-output industrial chassis-mount switching power supply engineered for factory automation, robotics, and precision test systems. Decoding its nomenclature, the JWT75-525 core platform delivers three isolated-common DC rails—an adjustable +5V (5.0–5.25V) main output at 0.8A to 8A, a +12V auxiliary rail up to 4A, and a -5V negative bias rail up to 0.5A—while the factory /RA suffix equips the unit with both Remote On/Off control (/R) and a protective metal cover over screw terminals (/A). Built with active Power Factor Correction compliant with EN61000-3-2, it accepts a universal 85–265VAC (47–63Hz) or 120–330VDC input at 72% typical efficiency while maintaining tight line regulation (20mV on +5V/-5V, 48mV on +12V) and low ripple and noise (120mV to 150mV peak-to-peak).
Housed in a slim, convection-cooled chassis measuring 42 × 92 × 188 mm (1.65 × 3.62 × 7.40 in) with dual-side mounting surfaces, the unit features barrier screw terminals and integrated protection against overcurrent (>105%) and main-rail overvoltage (5.7V–7V). Galvanic isolation is rated at 3 kVAC input-to-output, 2 kVAC input-to-ground, and 500 VAC output-to-ground, backed by 20 ms typical hold-up time and low earth leakage current (0.44 mA typical at 230 VAC). With the factory cover installed, it operates across -10 °C to +50 °C (14 °F to 122 °F) with linear derating to 60% load above 40 °C, and carries IEC/UL/CSA/EN 62368-1, EN 60950-1, VDE 0160, CE, and Class B EMI certifications.
Key Features
- Triple-Output Industrial Power Architecture: Delivers 75W total continuous power across three regulated rails: +5V (adjustable 5.0–5.25V) at 0.8A–8A, +12V up to 4A, and -5V up to 0.5A.
- Factory /RA Option Package: Combines integrated Remote On/Off logic control (/R) for automated system sequencing with a protective metal terminal cover (/A) for enhanced operator safety.
- Universal AC/DC Input with Active PFC: Operates from 85–265VAC (47–63Hz) or 120–330VDC with built-in Power Factor Correction compliant with EN 61000-3-2 harmonics and 14A/28A cold-start inrush limiting.
- Tight Multi-Rail Regulation & Low Ripple: Maintains ±5% output accuracy on V2/V3, 40mV load regulation on V1, temperature coefficients below 0.02%–0.03%/°C, and 120–150mV maximum ripple and noise.
- Slim Convection-Cooled Chassis Form Factor: Compact 42 × 92 × 188 mm (1.65 × 3.62 × 7.40 in) footprint weighing 600 g (1.32 lbs) with dual-side mounting holes and reliable fanless natural convection cooling.
- Reinforced 3 kVAC Isolation & Overvoltage Protection: Provides 3 kVAC input-to-output isolation, >105% overcurrent protection, main-channel overvoltage clamping (5.7–7V), and 20 ms hold-up time for brownout immunity.
- Global Safety & Class B EMI Compliance: Certified to IEC/UL/CSA/EN 62368-1, 60950-1, and VDE 0160 machinery directives while meeting EN 55011/55022-B, FCC Class B, and VCCI-B emissions.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | JWT75-525/RA |
| Alternate Part Number | JWT75525RA |
| Product Series | JWT Series (JWT75) |
| Product Category | Chassis Power Supplies |
| Component Type | Triple-Output Enclosed AC-DC Switching Power Supply (with Cover & Remote On/Off) |
| Circuit Topology | AC-DC Switching Power Supply with Active Power Factor Correction (PFC) |
| Nominal Output Voltage | +5 VDC (V1), +12 VDC (V2), -5 VDC (V3) |
| Output Voltage Adjustment Range | 5.0 to 5.25 VDC (V1 Main Output; V2 & V3 Fixed) |
| Rated Output Current | 8 A (V1), 4 A (V2), 0.5 A (V3) |
| Output Current Range | 0.8 to 8 A (V1), 0 to 4 A (V2), 0 to 0.5 A (V3) |
| Rated Output Power | 75 W (Combined Total Output) |
| Number of Outputs | 3 Outputs (Triple Output) |
| Ch1 Output Voltage & Current | V1: +5 VDC (5.0–5.25 VDC Adjustable), 0.8 A Min. to 8 A Max. |
| Ch2 Output Voltage & Current | V2: +12 VDC (Fixed), 0 A Min. to 4 A Max. |
| Ch3 Output Voltage & Current | V3: -5 VDC (Fixed), 0 A Min. to 0.5 A Max. |
| Output Ripple & Noise (Max.) | 120 mVp-p (V1 +5V), 150 mVp-p (V2 +12V & V3 -5V) |
| Output Voltage Tolerance | V1 Variable (5.0–5.25 V); V2 & V3 ±5% |
| Line Regulation | 20 mV (V1 +5V), 48 mV (V2 +12V), 20 mV (V3 -5V) |
| Load Regulation | 40 mV (V1 +5V), 100 mV (V2 +12V), 100 mV (V3 -5V) |
| Hold-Up Time | 20 ms (Typical, 115 / 230 VAC) |
| AC Input Voltage Range | 85 to 265 VAC (Universal Single-Phase) |
| DC Input Voltage Range | 120 to 330 VDC |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency | 72% (Typical) |
| AC Input Current (at 115 VAC) | 1.2 A (Typical at 100/115 VAC) |
| AC Input Current (at 230 VAC) | 0.6 A (Typical at 200/230 VAC) |
| Inrush Current (Cold Start at 115 VAC) | 14 A (at 100 VAC Input) |
| Inrush Current (Cold Start at 230 VAC) | 28 A (at 200 VAC Input) |
| Power Factor Correction (PFC) | Active PFC, Meets EN 61000-3-2 |
| Mounting Style | Chassis Mount (Dual-Side Mounting Surfaces) |
| Cooling Method | Natural Convection (Fanless) |
| Overall Width (W) | 42 mm (1.65 in) |
| Overall Height (H) | 92 mm (3.62 in) |
| Overall Depth (D) | 188 mm (7.40 in) |
| Net Weight | 600 g (0.60 kg / 1.32 lbs / 21.16 oz) |
| Termination / Connector Style | Screw Terminals with Factory Protective Cover (/A Option) |
| Control & Monitoring Signals | Remote On / Off Control (/R Option) |
| Enclosure / Potting Material | Perforated Metal Chassis with Protective Cover (/A) |
| Overload Protection (OLP) Threshold | >105% of Rated Output Current |
| Overvoltage Protection (OVP) Threshold | 5.7 to 7.0 VDC (V1 Main +5V Output Only) |
| Withstand Isolation Voltage (I/P to O/P) | 3,000 VAC (3 kVAC, 20 mA cut-off, 1 min) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2,000 VAC (2 kVAC, 20 mA cut-off, 1 min) |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VAC (100 mA cut-off, 1 min) |
| Isolation Resistance (at 500 VDC) | >100 MΩ (Output to Ground at 25 °C & 70% RH) |
| Earth Leakage Current | 0.75 mA Max. (0.44 mA Typical at 230 VAC) |
| Operating Ambient Temperature Range | -10 °C to +50 °C (14 °F to 122 °F) with Cover (/A); -10 °C to +65 °C (14 °F to 149 °F) Open Frame |
| Full-Load Operating Temperature Limit | +40 °C (104 °F) with Cover (/A); +50 °C (122 °F) without Cover |
| High-Temperature Derating Rate | Derate linearly from 100% load at +40 °C to 60% load at +50 °C with Cover (/A) (4.0%/°C) |
| Storage Temperature Range | -30 °C to +85 °C (-22 °F to +185 °F) |
| Operating Relative Humidity | 30% to 90% RH (Non-Condensing) |
| Storage Relative Humidity | 10% to 95% RH (Non-Condensing) |
| Temperature Coefficient | <0.02%/°C (V1 & V2), <0.03%/°C (V3) |
| Vibration Resistance | 10 to 55 Hz (1 min sweep), 196 m/s² (20 G) constant along X, Y, Z axes for 1 hour (Non-Operating) |
| Safety Approvals (UL / North America) | UL 62368-1, UL 60950-1, CSA C22.2 No. 62368-1 / 60950-1 |
| Safety Approvals (IEC / EN / TÜV) | IEC 62368-1, EN 62368-1, IEC/EN 60950-1, VDE 0160 Machinery Directive, CE Mark |
| EMC Conducted & Radiated Emissions | EN 55011 Class B, EN 55022 Class B, FCC Class B, VCCI Class B |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 (Harmonic Current Emissions) |
| EMC Immunity Standards | IEC/EN 61000-4 Series Industrial Immunity Compliant (CE Marked) |
Industrial Applications & Compatible Systems
TDK-Lambda JWT75-525/RA supplies multi-rail logic and analog bias power for industrial OEM machinery and automated test platforms:
- CNC Machining & Industrial Robotics: Powers 5V digital logic boards, +12V relay/sensor buses, and -5V analog encoder or op-amp circuits inside multi-axis motion controllers.
- Automated Test & Measurement Equipment (ATE): Provides low-ripple multi-rail excitation and remote On/Off sequencing for burn-in racks, data acquisition modules, and benchtop instrumentation.
- Factory Process Control & Packaging Machinery: Serves VDE 0160-compliant control cabinets in automotive assembly, material handling conveyors, and chemical processing skids.
- Legacy Industrial System Retrofits: Direct drop-in replacement for triple-output (+5V/+12V/-5V) linear or older switching power supplies requiring screw-terminal safety covers.
Installation, Thermal Management & MRO Guidelines
Follow these engineering practices during panel integration and MRO replacement to ensure long service life:
- Minimum V1 Pre-Load Requirement: Maintain at least 0.8 A minimum load on the main +5V (V1) rail so that cross-regulation keeps the +12V (V2) and -5V (V3) outputs within their ±5% tolerance band.
- Convection Clearance & Thermal Derating: Leave unobstructed vertical airflow around the perforated cover; with the /A cover installed, derate total output power linearly from 75W (100%) at +40 °C down to 45W (60%) at +50 °C.
- Remote On/Off & Inrush Protection: Wire the /R remote On/Off control terminals with twisted-pair leads away from AC mains, and size upstream circuit breakers to accommodate 28 A cold-start inrush at 200/230 VAC.