TECS20F-15 Cosel 20.25W 15VDC Open Frame Power Supply

$33.00

Cosel TECS20F-15 (TECS20F15) 20.25W 15VDC 1.35A open-frame AC-DC power supply, 85-264VAC input, featuring 1×2.3in Class II footprint, 92% efficiency, and UL62368-1.

SKU: TECS20F-15 Category: Brand:

Description

Cosel TECS20F-15 (also known as TECS20F15) is an ultra-compact 20.25W single-output open-frame AC-DC power supply from the high-density TECS Series (TECS20F). Its nomenclature denotes the TEC series platform, S for single output, 20 for the 20W power tier, F for universal 85 to 264 VAC (45–440 Hz) input, and -15 for a factory-set 15 VDC (14.50–15.50 V) output delivering up to 1.35 A continuous current. Built around a variable-frequency 20 to 125 kHz flyback converter topology on a double-sided 1.1 mm FR-4 SMD PCB, the unit achieves high conversion efficiency of 91.0% typical at 100 VAC and 92.0% typical at 230 VAC. It maintains tight output stability with 60 mV max line regulation, 120 mV max load regulation, and 240 mVp-p max ripple and noise across low-load burst mode and full-load operation.

Engineered for space-constrained Class II equipment, the TECS20F-15 occupies a miniature 1.00 × 2.30 inch footprint measuring 25.4 mm (1.00 in) W × 21.1 mm (0.83 in) H × 58.5 mm (2.30 in) D and weighing 35 g (1.23 oz) max. Input and output connections utilize reliable board-mount headers: CN1 (JST B2P3-VH) for AC line/neutral and CN2 (JST B2P-VH) for DC output, paired with an internal 250 VAC 1.6 A fuse and thermistor inrush current limiting. Comprehensive protection includes automatic-recovery overcurrent protection (>105% rating), overvoltage protection (17.25–21.00 VDC), and 3,000 VAC reinforced input-to-output isolation. Rated for -20 °C to +85 °C (-4 °F to +185 °F) ambient operation (full load to +50 °C via natural convection or +70 °C with 0.5 m³/min forced air), it carries UL 62368-1, EN 62368-1, CISPR 32 / EN 55032 Class B, and a 5-year OEM warranty.

Key Features

  • Ultra-Compact 1 × 2.3 Inch SMD Footprint: Delivers 20.25W (15 VDC at 1.35 A) from a miniature 25.4 × 21.1 × 58.5 mm (1.00 × 0.83 × 2.30 in) open-frame PCB weighing just 35 g max.
  • High-Efficiency Flyback Conversion: Achieves 91.0% typical efficiency at 100 VAC and 92.0% typical at 230 VAC across a universal 85 to 264 VAC (45 to 440 Hz) input range.
  • Precision 15 VDC Output Regulation: Factory calibrated between 14.50 and 15.50 VDC with 60 mV max line regulation, 120 mV max load regulation, 60 mV max drift, and 240 mVp-p max ripple noise.
  • Class II Reinforced 3,000 VAC Isolation: Eliminates functional earth ground requirements with 3,000 VAC 1-minute input-to-output dielectric withstand (10 mA cutoff), >100 MΩ isolation resistance, and 0.1 mA max leakage current.
  • Comprehensive Overload & Overvoltage Protection: Integrates automatic-recovery overcurrent protection triggering above 105% rated load, 17.25 to 21.00 VDC overvoltage protection, thermistor inrush limiting, and an onboard 250V 1.6A AC fuse.
  • Wide -20 °C to +85 °C Thermal Envelope: Supports 100% continuous load up to +50 °C under natural convection (all 6 mounting orientations A–F) or up to +70 °C with 0.5 m³/min forced-air cooling.
  • Global Safety & Class B EMI Compliance: Certified to UL 62368-1, C-UL, EN 62368-1, and DEN-AN alongside EN 55032 / CISPR 32 / FCC Part 15 Class B emissions and EN 61000-6-2 industrial immunity.

Technical Specifications

Manufacturer Cosel
Manufacturer Part Number (MPN) TECS20F-15
Alternate Part Number TECS20F15
Product Series TECS Series (TECS20F)
Product Category Thru-Hole DC-DC
Component Type AC-DC Open-Frame PCB Power Supply (Class II)
Circuit Topology Flyback Converter (Burst Mode at Light Load)
Nominal Output Voltage 15 VDC
Output Voltage Adjustment Range Fixed (Factory Set 14.50 to 15.50 VDC; ±10% Adjustable with Option -Y)
Rated Output Current 1.35 A
Rated Output Power 20.25 W
Number of Outputs 1 (Single Output)
Output Ripple & Noise (Max.) 200 mVp-p max Ripple / 240 mVp-p max Ripple & Noise (at -20 °C to +50 °C, measured with 22 µF and 0.1 µF capacitors at 150 mm)
Output Voltage Tolerance 14.50 to 15.50 VDC (±3.33% Factory Setting Range)
Line Regulation 60 mV max
Load Regulation 120 mV max
Setup Time 80 ms typ (at 100 / 230 VAC, 100% load)
Hold-Up Time (at 115 VAC) 10 ms typ (at 100 VAC, 100% load)
Hold-Up Time (at 230 VAC) 70 ms typ (at 230 VAC, 100% load)
AC Input Voltage Range 85 to 264 VAC, Single-Phase
Nominal Input Voltage 100 to 240 VAC
Input Frequency Range 45 to 440 Hz (50 / 60 Hz Nominal)
Efficiency (at 115 VAC) 91.0% typ (at 100 VAC, 100% load)
Efficiency (at 230 VAC) 92.0% typ (at 230 VAC, 100% load)
AC Input Current (at 115 VAC) 0.40 A typ (at 100 VAC, 100% load)
AC Input Current (at 230 VAC) 0.23 A typ (at 230 VAC, 100% load)
Inrush Current (Cold Start at 115 VAC) 15 A typ (at 100 VAC, 100% load, Ta = 25 °C, Thermistor Limited)
Inrush Current (Cold Start at 230 VAC) 35 A typ (at 230 VAC, 100% load, Ta = 25 °C, Thermistor Limited)
Power Factor Correction (PFC) Complies with IEC 61000-3-2 Class A Harmonic Attenuator (No Active PFC)
Switching Frequency 20 to 125 kHz
Mounting Style Chassis / Standoff Mount Open-Frame PCB (2 × Ø3.4 mm [Ø0.13 in] Mounting Holes for M3 Screws)
Cooling Method Natural Free Air Convection or Forced Air (0.5 m³/min External Fan)
Package / Footprint Standard 1.0 × 2.3 Inch Open-Frame PCB
Overall Width (W) 25.4 mm (1.00 in)
Overall Height (H) 21.1 mm (0.83 in) [18.1 mm / 0.71 in max component height, 3.0 mm / 0.12 in max lead protrusion]
Overall Depth (D) 58.5 mm (2.30 in)
Dimensional Tolerance ±1.5 mm (±0.06 in)
Mounting Hole Pitch 19.0 ± 0.5 mm × 52.1 ± 0.5 mm (0.75 in × 2.05 in)
Net Weight 35 g max (1.23 oz max) [50 g / 1.76 oz max with Optional -N Cover]
Termination / Connector Style Board-Mount JST VH Series Pin Headers (CN1 Input, CN2 Output)
Input Terminal Pinout CN1 (JST B2P3-VH): Pin 1 = AC(N), Pin 2 = Removed, Pin 3 = AC(L); Mates with JST VHR-3N Housing & SVH-21T-P1.1 / BVH-21T-P1.1 Terminals
Output & Signal Terminal Pinout CN2 (JST B2P-VH): Pin 1 = -Vout, Pin 2 = +Vout; Mates with JST VHR-2N Housing & SVH-21T-P1.1 / BVH-21T-P1.1 Terminals
Control & Monitoring Signals Series Operation Supported; Parallel Operation Not Supported; Remote Sensing Not Provided
Status Indicator Not Provided
Enclosure / Potting Material Double-Sided FR-4 PCB, 1.1 mm (0.04 in) Thickness (Optional -N Cover: PBT)
Overload Protection (OLP) Threshold >105% of Rated Output Current
Overload Protection (OLP) Mode Automatic Recovery
Overvoltage Protection (OVP) Threshold 17.25 to 21.00 VDC (115% to 140% of Nominal Output Voltage)
Overvoltage Protection (OVP) Mode Optocoupler Overvoltage Protection Circuit
Withstand Isolation Voltage (I/P to O/P) 3,000 VAC for 1 Minute (Cutoff Current = 10 mA)
Isolation Resistance (at 500 VDC) 100 MΩ min (Input to Output at Room Temperature)
Earth Leakage Current 0.1 mA max (at 264 VAC, 60 Hz, 100% Load per IEC 62368-1 and DEN-AN)
Operating Ambient Temperature Range -20 °C to +85 °C (-4 °F to +185 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) under Natural Convection (Positions A–F); +70 °C (+158 °F) with 0.5 m³/min Forced Air
High-Temperature Derating Rate Convection (Curve 2): Derates linearly from 100% load at +50 °C to 20% load at +85 °C; Forced Air 0.5 m³/min (Curve 3): Derates from 100% at +70 °C to 50% at +85 °C
Low-Line Input Derating Derates linearly from 100% load at 90 VAC to 80% load at 85 VAC
Altitude Derating 5,000 m (16,500 ft) max Operating / 9,000 m (30,000 ft) max Storage
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 20% to 90% RH (Non-Condensing)
Storage Relative Humidity 20% to 90% RH (Non-Condensing)
Temperature Coefficient 150 mV max (0 °C to +50 °C) / 200 mV max (-20 °C to +50 °C) Temperature Regulation; 60 mV max 8-Hour Drift
Vibration Resistance 10 to 55 Hz, 19.6 m/s² (2G), 3-Minute Period, 60 Minutes Each Along X, Y, and Z Axes; Impact: 196.1 m/s² (20G), 11 ms
Safety Approvals (UL / North America) UL 62368-1, C-UL (Equivalent to CAN/CSA-C22.2 No. 62368-1)
Safety Approvals (IEC / EN / TÜV) EN 62368-1, CE Marking (Low Voltage Directive), UKCA Marking (Electrical Equipment Safety Regulations)
Safety Approvals (Regional / Global) Complies with DEN-AN (Japan Electrical Appliance and Material Safety Law), Class II Protection, 5-Year Manufacturer Warranty
EMC Conducted & Radiated Emissions CISPR 11 Class B, CISPR 32 Class B, EN 55011 Class B, EN 55032 Class B, FCC Part 15 Class B, FCC Part 18 Class B, VCCI Class B
EMC Harmonic & Flicker Compliance IEC 61000-3-2 Class A
EMC Immunity Standards EN 61204-3, EN 61000-6-2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
Environmental Compliance RoHS Directive (EU) & UKCA RoHS Regulations Compliant

Industrial Applications & Compatible Systems

The Cosel TECS20F-15 is engineered for embedded OEM platforms and industrial control assemblies requiring an ultra-compact, Class II isolated 15 VDC auxiliary power rail.

  • Industrial Sensors, Analog Transmitters & Instrumentation: Powers 15 VDC operational amplifiers, precision signal conditioners, pressure transducers, and flow control loops requiring low 240 mVp-p ripple noise.
  • Factory Automation & Compact PLC Subsystems: Fits directly inside shallow operator panels, HMI enclosures, and distributed I/O boxes thanks to its miniature 25.4 × 58.5 mm (1.00 × 2.30 in) board footprint.
  • Test, Measurement & Laboratory Benchtop Equipment: Provides a Class II double-insulated 15 VDC supply with 0.1 mA max leakage current and CISPR 11 / EN 55011 Class B emissions for sensitive analytical instruments.
  • Building Automation, Access Control & Kiosk Terminals: Operates reliably across universal 85 to 264 VAC (45–440 Hz) mains inputs at elevations up to 5,000 m (16,500 ft) without requiring a safety earth connection.

Installation, Thermal Management & MRO Guidelines

Follow Cosel’s mechanical clearance, thermal derating, and connector mating rules during installation and MRO replacement.

  • Insulation Clearances & M3 Standoff Mounting: Maintain at least d1 ≥ 8 mm spacing from the PCB underside to any metal chassis and d2 ≥ 5 mm lateral clearance around the perimeter (or insert a reinforced insulating sheet), securing the two Ø3.4 mm holes with M3 screws while keeping hardware within the 6.7 mm corner pads and insulating the primary-side mounting hole.
  • SMD PCB Handling & JST VH Harness Termination: Never twist, bend, or touch the surface-mount components on the 1.1 mm FR-4 board; terminate input CN1 with a JST VHR-3N housing and output CN2 with a JST VHR-2N housing using SVH-21T-P1.1 or BVH-21T-P1.1 crimp contacts.
  • Thermal Derating & External EMI Filter Selection: Apply linear load derating above +50 °C in natural convection (down to 20% load at +85 °C) or supply 0.5 m³/min uniform forced air to sustain 100% load up to +70 °C, and pair with a Cosel EAM-03-000, EAP, or EAC filter when grounding the secondary circuit or attenuating high-voltage line transients.