Description
Cosel TECS20F-15 (also known as TECS20F15) is an ultra-compact 20.25W single-output open-frame AC-DC power supply from the high-density TECS Series (TECS20F). Its nomenclature denotes the TEC series platform, S for single output, 20 for the 20W power tier, F for universal 85 to 264 VAC (45–440 Hz) input, and -15 for a factory-set 15 VDC (14.50–15.50 V) output delivering up to 1.35 A continuous current. Built around a variable-frequency 20 to 125 kHz flyback converter topology on a double-sided 1.1 mm FR-4 SMD PCB, the unit achieves high conversion efficiency of 91.0% typical at 100 VAC and 92.0% typical at 230 VAC. It maintains tight output stability with 60 mV max line regulation, 120 mV max load regulation, and 240 mVp-p max ripple and noise across low-load burst mode and full-load operation.
Engineered for space-constrained Class II equipment, the TECS20F-15 occupies a miniature 1.00 × 2.30 inch footprint measuring 25.4 mm (1.00 in) W × 21.1 mm (0.83 in) H × 58.5 mm (2.30 in) D and weighing 35 g (1.23 oz) max. Input and output connections utilize reliable board-mount headers: CN1 (JST B2P3-VH) for AC line/neutral and CN2 (JST B2P-VH) for DC output, paired with an internal 250 VAC 1.6 A fuse and thermistor inrush current limiting. Comprehensive protection includes automatic-recovery overcurrent protection (>105% rating), overvoltage protection (17.25–21.00 VDC), and 3,000 VAC reinforced input-to-output isolation. Rated for -20 °C to +85 °C (-4 °F to +185 °F) ambient operation (full load to +50 °C via natural convection or +70 °C with 0.5 m³/min forced air), it carries UL 62368-1, EN 62368-1, CISPR 32 / EN 55032 Class B, and a 5-year OEM warranty.
Key Features
- Ultra-Compact 1 × 2.3 Inch SMD Footprint: Delivers 20.25W (15 VDC at 1.35 A) from a miniature 25.4 × 21.1 × 58.5 mm (1.00 × 0.83 × 2.30 in) open-frame PCB weighing just 35 g max.
- High-Efficiency Flyback Conversion: Achieves 91.0% typical efficiency at 100 VAC and 92.0% typical at 230 VAC across a universal 85 to 264 VAC (45 to 440 Hz) input range.
- Precision 15 VDC Output Regulation: Factory calibrated between 14.50 and 15.50 VDC with 60 mV max line regulation, 120 mV max load regulation, 60 mV max drift, and 240 mVp-p max ripple noise.
- Class II Reinforced 3,000 VAC Isolation: Eliminates functional earth ground requirements with 3,000 VAC 1-minute input-to-output dielectric withstand (10 mA cutoff), >100 MΩ isolation resistance, and 0.1 mA max leakage current.
- Comprehensive Overload & Overvoltage Protection: Integrates automatic-recovery overcurrent protection triggering above 105% rated load, 17.25 to 21.00 VDC overvoltage protection, thermistor inrush limiting, and an onboard 250V 1.6A AC fuse.
- Wide -20 °C to +85 °C Thermal Envelope: Supports 100% continuous load up to +50 °C under natural convection (all 6 mounting orientations A–F) or up to +70 °C with 0.5 m³/min forced-air cooling.
- Global Safety & Class B EMI Compliance: Certified to UL 62368-1, C-UL, EN 62368-1, and DEN-AN alongside EN 55032 / CISPR 32 / FCC Part 15 Class B emissions and EN 61000-6-2 industrial immunity.
Technical Specifications
| Manufacturer | Cosel |
|---|---|
| Manufacturer Part Number (MPN) | TECS20F-15 |
| Alternate Part Number | TECS20F15 |
| Product Series | TECS Series (TECS20F) |
| Product Category | Thru-Hole DC-DC |
| Component Type | AC-DC Open-Frame PCB Power Supply (Class II) |
| Circuit Topology | Flyback Converter (Burst Mode at Light Load) |
| Nominal Output Voltage | 15 VDC |
| Output Voltage Adjustment Range | Fixed (Factory Set 14.50 to 15.50 VDC; ±10% Adjustable with Option -Y) |
| Rated Output Current | 1.35 A |
| Rated Output Power | 20.25 W |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 200 mVp-p max Ripple / 240 mVp-p max Ripple & Noise (at -20 °C to +50 °C, measured with 22 µF and 0.1 µF capacitors at 150 mm) |
| Output Voltage Tolerance | 14.50 to 15.50 VDC (±3.33% Factory Setting Range) |
| Line Regulation | 60 mV max |
| Load Regulation | 120 mV max |
| Setup Time | 80 ms typ (at 100 / 230 VAC, 100% load) |
| Hold-Up Time (at 115 VAC) | 10 ms typ (at 100 VAC, 100% load) |
| Hold-Up Time (at 230 VAC) | 70 ms typ (at 230 VAC, 100% load) |
| AC Input Voltage Range | 85 to 264 VAC, Single-Phase |
| Nominal Input Voltage | 100 to 240 VAC |
| Input Frequency Range | 45 to 440 Hz (50 / 60 Hz Nominal) |
| Efficiency (at 115 VAC) | 91.0% typ (at 100 VAC, 100% load) |
| Efficiency (at 230 VAC) | 92.0% typ (at 230 VAC, 100% load) |
| AC Input Current (at 115 VAC) | 0.40 A typ (at 100 VAC, 100% load) |
| AC Input Current (at 230 VAC) | 0.23 A typ (at 230 VAC, 100% load) |
| Inrush Current (Cold Start at 115 VAC) | 15 A typ (at 100 VAC, 100% load, Ta = 25 °C, Thermistor Limited) |
| Inrush Current (Cold Start at 230 VAC) | 35 A typ (at 230 VAC, 100% load, Ta = 25 °C, Thermistor Limited) |
| Power Factor Correction (PFC) | Complies with IEC 61000-3-2 Class A Harmonic Attenuator (No Active PFC) |
| Switching Frequency | 20 to 125 kHz |
| Mounting Style | Chassis / Standoff Mount Open-Frame PCB (2 × Ø3.4 mm [Ø0.13 in] Mounting Holes for M3 Screws) |
| Cooling Method | Natural Free Air Convection or Forced Air (0.5 m³/min External Fan) |
| Package / Footprint Standard | 1.0 × 2.3 Inch Open-Frame PCB |
| Overall Width (W) | 25.4 mm (1.00 in) |
| Overall Height (H) | 21.1 mm (0.83 in) [18.1 mm / 0.71 in max component height, 3.0 mm / 0.12 in max lead protrusion] |
| Overall Depth (D) | 58.5 mm (2.30 in) |
| Dimensional Tolerance | ±1.5 mm (±0.06 in) |
| Mounting Hole Pitch | 19.0 ± 0.5 mm × 52.1 ± 0.5 mm (0.75 in × 2.05 in) |
| Net Weight | 35 g max (1.23 oz max) [50 g / 1.76 oz max with Optional -N Cover] |
| Termination / Connector Style | Board-Mount JST VH Series Pin Headers (CN1 Input, CN2 Output) |
| Input Terminal Pinout | CN1 (JST B2P3-VH): Pin 1 = AC(N), Pin 2 = Removed, Pin 3 = AC(L); Mates with JST VHR-3N Housing & SVH-21T-P1.1 / BVH-21T-P1.1 Terminals |
| Output & Signal Terminal Pinout | CN2 (JST B2P-VH): Pin 1 = -Vout, Pin 2 = +Vout; Mates with JST VHR-2N Housing & SVH-21T-P1.1 / BVH-21T-P1.1 Terminals |
| Control & Monitoring Signals | Series Operation Supported; Parallel Operation Not Supported; Remote Sensing Not Provided |
| Status Indicator | Not Provided |
| Enclosure / Potting Material | Double-Sided FR-4 PCB, 1.1 mm (0.04 in) Thickness (Optional -N Cover: PBT) |
| Overload Protection (OLP) Threshold | >105% of Rated Output Current |
| Overload Protection (OLP) Mode | Automatic Recovery |
| Overvoltage Protection (OVP) Threshold | 17.25 to 21.00 VDC (115% to 140% of Nominal Output Voltage) |
| Overvoltage Protection (OVP) Mode | Optocoupler Overvoltage Protection Circuit |
| Withstand Isolation Voltage (I/P to O/P) | 3,000 VAC for 1 Minute (Cutoff Current = 10 mA) |
| Isolation Resistance (at 500 VDC) | 100 MΩ min (Input to Output at Room Temperature) |
| Earth Leakage Current | 0.1 mA max (at 264 VAC, 60 Hz, 100% Load per IEC 62368-1 and DEN-AN) |
| Operating Ambient Temperature Range | -20 °C to +85 °C (-4 °F to +185 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) under Natural Convection (Positions A–F); +70 °C (+158 °F) with 0.5 m³/min Forced Air |
| High-Temperature Derating Rate | Convection (Curve 2): Derates linearly from 100% load at +50 °C to 20% load at +85 °C; Forced Air 0.5 m³/min (Curve 3): Derates from 100% at +70 °C to 50% at +85 °C |
| Low-Line Input Derating | Derates linearly from 100% load at 90 VAC to 80% load at 85 VAC |
| Altitude Derating | 5,000 m (16,500 ft) max Operating / 9,000 m (30,000 ft) max Storage |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 20% to 90% RH (Non-Condensing) |
| Storage Relative Humidity | 20% to 90% RH (Non-Condensing) |
| Temperature Coefficient | 150 mV max (0 °C to +50 °C) / 200 mV max (-20 °C to +50 °C) Temperature Regulation; 60 mV max 8-Hour Drift |
| Vibration Resistance | 10 to 55 Hz, 19.6 m/s² (2G), 3-Minute Period, 60 Minutes Each Along X, Y, and Z Axes; Impact: 196.1 m/s² (20G), 11 ms |
| Safety Approvals (UL / North America) | UL 62368-1, C-UL (Equivalent to CAN/CSA-C22.2 No. 62368-1) |
| Safety Approvals (IEC / EN / TÜV) | EN 62368-1, CE Marking (Low Voltage Directive), UKCA Marking (Electrical Equipment Safety Regulations) |
| Safety Approvals (Regional / Global) | Complies with DEN-AN (Japan Electrical Appliance and Material Safety Law), Class II Protection, 5-Year Manufacturer Warranty |
| EMC Conducted & Radiated Emissions | CISPR 11 Class B, CISPR 32 Class B, EN 55011 Class B, EN 55032 Class B, FCC Part 15 Class B, FCC Part 18 Class B, VCCI Class B |
| EMC Harmonic & Flicker Compliance | IEC 61000-3-2 Class A |
| EMC Immunity Standards | EN 61204-3, EN 61000-6-2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11 |
| Environmental Compliance | RoHS Directive (EU) & UKCA RoHS Regulations Compliant |
Industrial Applications & Compatible Systems
The Cosel TECS20F-15 is engineered for embedded OEM platforms and industrial control assemblies requiring an ultra-compact, Class II isolated 15 VDC auxiliary power rail.
- Industrial Sensors, Analog Transmitters & Instrumentation: Powers 15 VDC operational amplifiers, precision signal conditioners, pressure transducers, and flow control loops requiring low 240 mVp-p ripple noise.
- Factory Automation & Compact PLC Subsystems: Fits directly inside shallow operator panels, HMI enclosures, and distributed I/O boxes thanks to its miniature 25.4 × 58.5 mm (1.00 × 2.30 in) board footprint.
- Test, Measurement & Laboratory Benchtop Equipment: Provides a Class II double-insulated 15 VDC supply with 0.1 mA max leakage current and CISPR 11 / EN 55011 Class B emissions for sensitive analytical instruments.
- Building Automation, Access Control & Kiosk Terminals: Operates reliably across universal 85 to 264 VAC (45–440 Hz) mains inputs at elevations up to 5,000 m (16,500 ft) without requiring a safety earth connection.
Installation, Thermal Management & MRO Guidelines
Follow Cosel’s mechanical clearance, thermal derating, and connector mating rules during installation and MRO replacement.
- Insulation Clearances & M3 Standoff Mounting: Maintain at least d1 ≥ 8 mm spacing from the PCB underside to any metal chassis and d2 ≥ 5 mm lateral clearance around the perimeter (or insert a reinforced insulating sheet), securing the two Ø3.4 mm holes with M3 screws while keeping hardware within the 6.7 mm corner pads and insulating the primary-side mounting hole.
- SMD PCB Handling & JST VH Harness Termination: Never twist, bend, or touch the surface-mount components on the 1.1 mm FR-4 board; terminate input CN1 with a JST VHR-3N housing and output CN2 with a JST VHR-2N housing using SVH-21T-P1.1 or BVH-21T-P1.1 crimp contacts.
- Thermal Derating & External EMI Filter Selection: Apply linear load derating above +50 °C in natural convection (down to 20% load at +85 °C) or supply 0.5 m³/min uniform forced air to sustain 100% load up to +70 °C, and pair with a Cosel EAM-03-000, EAP, or EAC filter when grounding the secondary circuit or attenuating high-voltage line transients.