Description
Cosel TECS65F-12-N (also known as TECS65F12N) is an industrial 65.4W single-output AC-DC power supply from the high-density TECS65F series, where nomenclature codes denote S for single output, 65 for the 65W wattage class, F for universal AC input, 12 for a 12VDC rail, and -N for the factory-installed protective cover. Built around a high-frequency 20 to 800 kHz flyback converter topology on a multilayer FR-4 PCB, it accepts a universal 85 to 264 VAC (45–66 Hz) input and delivers a tightly regulated 12 VDC at 5.45 A with up to 93.0% typical efficiency at 230 VAC (91.5% at 100 VAC). Output stability is maintained across line and load variations with 48 mV max line regulation, 100 mV max load regulation, and 380 mVp-p max ripple and noise.
Built on a compact 1×3-inch base footprint, the -N covered version measures 30.7 × 31.1 × 80.3 mm (1.21 × 1.22 × 3.16 in) and weighs just 90 g (3.17 oz) max with a protective PBT resin cover for touch-safe chassis integration. Electrical connections are made via onboard JST B2P3-VH (CN1 AC input) and JST B4P-VH (CN2 DC output) headers, backed by an internal 250 VAC 5 A fuse, thermistor inrush current limiting, automatic-recovery overcurrent protection (>105%), and overvoltage protection (13.20–15.60 V). Designed for Class II double-insulated installations without a functional earth ground, it provides 3,000 VAC input-to-output galvanic isolation, operates from -10 °C to +70 °C (+14 °F to +158 °F), and holds full UL 62368-1, EN 62368-1, Class B EMI, and IEC 61000-3-2 Class A approvals.
Key Features
- Ultra-Compact 1×3-Inch Covered Footprint: Factory-installed PBT protective cover (-N option) encloses the 1×3-inch open-frame PCB within 30.7 × 31.1 × 80.3 mm (1.21 × 1.22 × 3.16 in) and 90 g max weight.
- High-Efficiency 65.4W 12VDC Output: Delivers 12 VDC at 5.45 A continuous current (65.4 W rated power) with 91.5% typical efficiency at 100 VAC and 93.0% typical efficiency at 230 VAC.
- Universal Class II Double-Insulated Input: Operates across 85 to 264 VAC (45–66 Hz) single-phase lines with Class II construction, eliminating safety earth wiring while keeping touch leakage below 0.25 mA at 264 VAC.
- Tight Output Regulation & Low Drift: Maintains 48 mV max line regulation, 100 mV max load regulation, 48 mV max 8-hour stability drift, and 380 mVp-p max ripple noise across -10 °C to +40 °C.
- Comprehensive Protection & 3kVAC Isolation: Integrates a 250V 5A AC fuse, thermistor inrush limiter, auto-recovery overcurrent protection above 105%, 13.20–15.60 V overvoltage protection, and 3,000 VAC input-to-output dielectric isolation.
- Global Safety & Class B EMC Compliance: Certified to UL 62368-1, C-UL, EN 62368-1, and DEN-AN with CISPR 32 / EN 55032 Class B conducted emissions, IEC 61000-3-2 Class A harmonics, and EN 61000-6-2 industrial immunity.
- Convection & Forced-Air Thermal Flexibility: Supports natural convection cooling up to +35 °C at 100% load (derating to +60 °C) or 0.5 m³/min forced-air cooling for full 65.4 W output up to +50 °C (derating to +70 °C).
Technical Specifications
| Manufacturer | Cosel |
|---|---|
| Manufacturer Part Number (MPN) | TECS65F-12-N |
| Alternate Part Number | TECS65F12N |
| Product Series | TECS Series (TECS65F) |
| Product Category | Thru-Hole DC-DC |
| Component Type | Open-Frame AC-DC Power Supply with Protective Cover (-N Option) |
| Circuit Topology | Flyback Converter (SMD Multilayer FR-4 PCB) |
| Nominal Output Voltage | 12 VDC |
| Output Voltage Adjustment Range | Fixed (Factory Output Voltage Setting: 11.50 to 12.50 VDC) |
| Rated Output Current | 5.45 A |
| Rated Output Power | 65.4 W |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 380 mVp-p max Ripple Noise / 300 mVp-p max Ripple (-10 °C to +40 °C, measured with 22 µF + 0.1 µF capacitors at 150 mm) |
| Line Regulation | 48 mV max |
| Load Regulation | 100 mV max (Burst mode activates at low load; measure in average mode) |
| Setup Time | 500 ms typ (at 100 / 230 VAC, 100% load) |
| Hold-Up Time (at 115 VAC) | 10 ms typ (at 100 VAC, 80% load) |
| Hold-Up Time (at 230 VAC) | 60 ms typ (at 230 VAC, 100% load) |
| AC Input Voltage Range | 85 to 264 VAC, Single-Phase (Derate linearly from 100% load at 90 VAC to 80% load at 85 VAC) |
| Input Frequency Range | 45 to 66 Hz (Nominal 50 / 60 Hz) |
| Efficiency (at 115 VAC) | 91.5% typ (at 100 VAC, 100% load) |
| Efficiency (at 230 VAC) | 93.0% typ (at 230 VAC, 100% load) |
| AC Input Current (at 115 VAC) | 1.25 A typ (at 100 VAC, 100% load) |
| AC Input Current (at 230 VAC) | 0.70 A typ (at 230 VAC, 100% load) |
| Inrush Current (Cold Start at 115 VAC) | 30 A typ (at 100 VAC, 100% load, Ta = 25 °C, Thermistor protection) |
| Inrush Current (Cold Start at 230 VAC) | 65 A typ (at 230 VAC, 100% load, Ta = 25 °C, Thermistor protection) |
| Power Factor Correction (PFC) | Passive Harmonic Attenuator Compliance (Complies with IEC 61000-3-2 Class A; no active PFC) |
| Switching Frequency | 20 to 800 kHz (Variable frequency flyback) |
| Mounting Style | Chassis / Standoff Mount (2 × Ø3.4 mm [Ø0.13 in] mounting holes for M3 screws) |
| Cooling Method | Natural Convection or Forced Air Cooling (0.5 m³/min uniform airflow) |
| Package / Footprint Standard | 1 × 3 Inch Class Covered Open-Frame Package (-N Cover Type) |
| Overall Width (W) | 30.7 mm (1.21 in) with cover [Base PCB Width: 25.4 mm (1.00 in)] |
| Overall Height (H) | 31.1 mm (1.22 in) with cover [Base Open-Frame Height: 27.0 mm (1.06 in)] |
| Overall Depth (D) | 80.3 mm (3.16 in) with cover [Base PCB Depth: 76.2 mm (3.00 in)] |
| Dimensional Tolerance | ±1.5 mm (±0.06 in) |
| Mounting Hole Pitch | 19.0 ±0.5 mm × 69.8 ±0.5 mm (0.75 in × 2.75 in) |
| Net Weight | 90 g max / 0.09 kg (3.17 oz / 0.20 lbs) with cover [Base Open-Frame: 70 g max (2.47 oz)] |
| Termination / Connector Style | JST VH Series Top-Entry PCB Pin Headers (Mates with JST VHR-3N and VHR-4N housings using SVH-21T-P1.1 / BVH-21T-P1.1 crimp terminals) |
| Input Terminal Pinout | CN1 (JST B2P3-VH, 2-Pole on 3-Pin Pitch): Pin 1 = AC(N) Neutral, Pin 2 = Removed/Keyed, Pin 3 = AC(L) Line (Internal Fuse: AC 250V 5A) |
| Output & Signal Terminal Pinout | CN2 (JST B4P-VH, 4-Pin, max 5 A per contact): Pin 1 = -Vout, Pin 2 = -Vout, Pin 3 = +Vout, Pin 4 = +Vout |
| Control & Monitoring Signals | Remote Sensing: Not provided; Series Operation: Supported; Parallel Operation: Not possible |
| Status Indicator | Not provided |
| Enclosure / Potting Material | PBT Protective Cover (-N Option) over 1.1 mm (0.04 in) Multilayer FR-4 PCB |
| Overload Protection (OLP) Threshold | >105% of rated output current |
| Overload Protection (OLP) Mode | Automatic recovery upon fault removal |
| Overvoltage Protection (OVP) Threshold | 13.20 to 15.60 VDC |
| Withstand Isolation Voltage (I/P to O/P) | 3,000 VAC for 1 minute (Cutoff current = 10 mA, Class II double/reinforced insulation) |
| Isolation Resistance (at 500 VDC) | 100 MΩ min (Input to Output at room temperature) |
| Earth Leakage Current | 0.25 mA max (at 264 VAC, 60 Hz, 100% load per IEC 62368-1 and DEN-AN) |
| Operating Ambient Temperature Range | -10 °C to +70 °C (+14 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +35 °C (+95 °F) under natural convection (Positions A–E, Curve 1); +50 °C (+122 °F) with 0.5 m³/min forced air (Positions A–F, Curve 3) |
| High-Temperature Derating Rate | Convection (Positions A–E): Derates from 100% load at +35 °C to 20% load at +60 °C; Forced Air (0.5 m³/min): Derates from 100% load at +50 °C to 60% load at +70 °C |
| Low-Line Input Derating | Derate output load linearly from 100% at 90 VAC down to 80% at 85 VAC |
| Altitude Derating | 5,000 m (16,500 ft) max operating altitude; 9,000 m (30,000 ft) max storage altitude |
| Storage Temperature Range | -20 °C to +75 °C (-4 °F to +167 °F) |
| Operating Relative Humidity | 20% to 90% RH (Non-condensing) |
| Storage Relative Humidity | 20% to 90% RH (Non-condensing) |
| Temperature Coefficient | 120 mV max across 0 °C to +40 °C / 150 mV max across -10 °C to +40 °C; 8-Hour Warm-Up Drift: 48 mV max |
| Vibration Resistance | 10 to 55 Hz, 19.6 m/s² (2G), 3-minute sweep period, 60 minutes each along X, Y, and Z axes; Mechanical Impact: 196.1 m/s² (20G), 11 ms, once per X, Y, Z axis |
| Safety Approvals (UL / North America) | UL 62368-1, C-UL (equivalent to CAN/CSA-C22.2 No. 62368-1) |
| Safety Approvals (IEC / EN / TÜV) | EN 62368-1, CE Marking (Low Voltage Directive), Class II Protection |
| Safety Approvals (Regional / Global) | DEN-AN (Japan PSE), UKCA Marking (Electrical Equipment Safety Regulations), 5-Year OEM Warranty |
| EMC Conducted & Radiated Emissions | CISPR 11 Class B, CISPR 32 Class B, EN 55011 Class B, EN 55032 Class B, FCC Part 15 Class B, FCC Part 18 Class B, VCCI Class B |
| EMC Harmonic & Flicker Compliance | IEC 61000-3-2 Class A |
| EMC Immunity Standards | EN 61204-3, EN 61000-6-2 (EN 61000-4-2 ESD, EN 61000-4-3 Radiated RF, EN 61000-4-4 EFT/Burst, EN 61000-4-5 Surge, EN 61000-4-6 Conducted RF, EN 61000-4-8 Power Frequency Magnetic Field, EN 61000-4-11 Voltage Dips & Interruptions) |
| Environmental Compliance | RoHS Directive (EU) & UK RoHS Regulations Compliant |
Industrial Applications & Compatible Systems
The Cosel TECS65F-12-N is engineered for space-constrained industrial, commercial, and laboratory equipment requiring a touch-protected 12 VDC auxiliary or main power rail in Class II enclosures.
- Compact Industrial Automation & PLC Subsystems: Powers 12 VDC embedded controllers, sensor arrays, optical inspection cameras, and HMI operator panels inside slim control housings.
- Laboratory, Test & Analytical Instrumentation: Provides low-noise 12 VDC power with Class B EMI compliance and <0.25 mA touch current for benchtop analyzers, chromatographs, and diagnostic testers.
- Semiconductor & Factory Robotics Peripherals: Supplies 5.45 A continuous current to wafer handling actuators, stepper/solenoid manifolds, and pneumatic valve banks where a protective PBT cover prevents accidental debris contact.
- Telecom, Broadcast & Edge Computing Appliances: Fits high-density 1U/2U chassis and wall-mounted gateway enclosures requiring universal 85–264 VAC input and 3,000 VAC galvanic isolation.
Installation, Thermal Management & MRO Guidelines
Follow Cosel’s mechanical mounting, wiring, and thermal derating guidelines to maximize reliability over the unit’s 5-year warranty period.
- Orientation & Forced-Air Thermal Management: Under natural convection in mounting positions A through E, apply 100% load (5.45 A) up to +35 °C and derate linearly to 20% load at +60 °C; inverted position F requires 0.5 m³/min uniform forced-air cooling, which extends full-load operation up to +50 °C.
- Dual-Pin Output Harness Wiring on CN2: Because each pin on the JST B4P-VH output header (CN2) is rated for a maximum of 5.0 A and the supply delivers 5.45 A, wire both Pin 1 and Pin 2 for -Vout and both Pin 3 and Pin 4 for +Vout using VHR-4N housings and SVH-21T-P1.1 crimp terminals.
- PCB Stress Prevention & Primary Side Insulation: Fasten the two Ø3.4 mm mounting holes using M3 screws within the 6.7 mm corner land areas without twisting or bending the multilayer SMD PCB, and maintain primary-side insulation clearance to user-accessible conductive parts.
- Upstream EMI Filter & Inrush Coordination: Pair with a Cosel EAC-03-000 (or EAP series high-pulse) line filter when the secondary DC return is earth-grounded, and size upstream AC switches and circuit breakers for the 65 A cold-start inrush peak at 230 VAC.





