Description
WAGO 787-1211 (also known as 7871211) is a compact 60W single-phase switched-mode power supply from the EPSITRON® COMPACT Power (787-12xx) series, engineered specifically for space-restricted distribution boards and building automation panels. Decoding the WAGO part nomenclature, the 787 prefix designates industrial power electronics, the 12 series identifier denotes the stepped-profile COMPACT generation, and the 11 suffix specifies a regulated 12 VDC nominal output at 5 A (60 W). Driven by a wide-range primary stage accepting 85 to 264 VAC (47–63 Hz) or 125 to 375 VDC, the supply achieves up to 88.5% typical efficiency at 230 VAC (87.5% at 110 VAC) while limiting no-load standby dissipation to ≤ 0.6 W. Its secondary control loop trims cleanly from 10 to 14 VDC via a front potentiometer, holding static and dynamic (10–90% load step) voltage deviation within ≤ 1% and output ripple and noise below 100 mVp-p.
Packaged in a UL 94V-0 flame-retardant stepped enclosure measuring 72 mm × 90 mm × 56 mm (2.835 in × 3.543 in × 2.205 in) and weighing just 63 g (2.22 oz), the unit snaps onto standard DIN-35 rails or mounts directly into flat enclosures using its removable front cover and integrated screw flanges (reducing depth to 48 mm / 1.89 in). Field wiring is accelerated by tool-free pluggable WAGO 2092 Series picoMAX® 5.0 Push-in CAGE CLAMP® connectors accommodating 24 to 12 AWG (0.2–2.5 mm²) solid or fine-stranded conductors. Comprehensive protection includes constant-power overload limiting (1.22–1.7 × Io nom), hiccup-mode short-circuit recovery, secondary overvoltage clamping at ≤ 20 VDC, and 4.242 kVDC primary-to-secondary galvanic isolation. Certified to UL 508, UL 60950-1, EN 62368-1, EN 60335-1, and EN 61204-3, it operates reliably from -25 °C to +70 °C (-13 °F to +158 °F) with an MTBF exceeding 500,000 hours per IEC 61709.
Key Features
- Stepped Distribution Board Form Factor: Engineered with a 72 × 90 × 56 mm (2.835 × 3.543 × 2.205 in) stepped profile and removable front cover for flush installation in shallow sub-distribution panels or screw-mount chassis.
- Regulated 12VDC 5A SELV/PELV Output: Delivers 60 W continuous power with a 10 to 14 VDC potentiometer adjustment range, ≤ 1% static/dynamic voltage deviation, and ≤ 100 mVp-p residual ripple for sensitive controllers.
- Universal AC/DC Input & High Efficiency: Accepts 85 to 264 VAC or 125 to 375 VDC input, reaching 88.5% typical efficiency at 230 VAC, ≤ 0.6 W no-load power loss, and ≥ 600 ms hold-up time at 230 VAC.
- Tool-Free Pluggable picoMAX® 5.0 Terminals: Equipped with WAGO 2092 Series Push-in CAGE CLAMP® connectors supporting 0.2 to 2.5 mm² (24–12 AWG) conductors for rapid pre-wiring and vibration-proof termination.
- Constant-Power Overload & Fault Protection: Features constant-power behavior between 1.22 and 1.7 × rated current (6.1–8.5 A), automatic hiccup short-circuit protection, ≤ 20 VDC secondary OVP, and internal T 3.15 A fusing.
- Parallel & Series Redundancy Ready: Supports direct parallel connection for load expansion or N+1 redundancy and two-unit series connection (up to 24 VDC) backed by ≤ 16 VDC reverse-feed resistance.
- Reinforced 4.242 kVDC Galvanic Isolation: Provides 4.242 kVDC primary-to-secondary and 2.12 kVDC primary-to-PE dielectric strength, meeting Protection Class I, Overvoltage Category II, and SELV/PELV safety requirements.
- Wide Industrial Temperature & Global Approvals: Operates from -25 °C to +70 °C (-13 °F to +158 °F) with > 500,000-hour IEC 61709 MTBF and full UL 508, EN 60335-1, EN 62368-1, and EN 61204-3 compliance.
Technical Specifications
| Manufacturer | WAGO |
|---|---|
| Manufacturer Part Number (MPN) | 787-1211 |
| Alternate Part Number | 7871211 |
| Product Series | EPSITRON® COMPACT Power (787-12xx Series) |
| Product Category | Low-Profile DIN Rail |
| Component Type | Single-Phase Stepped-Profile DIN Rail Switched-Mode Power Supply |
| Circuit Topology | Switched-Mode Power Supply (SMPS), Regulated SELV / PELV Output |
| Nominal Output Voltage | 12 VDC (Default Factory Setting, SELV / PELV) |
| Output Voltage Adjustment Range | 10 to 14 VDC (Adjustable via Front Potentiometer) |
| Rated Output Current | 5 A |
| Rated Output Power | 60 W |
| Number of Outputs | 1 Output (Single Channel, Parallel & Series Operation Capable) |
| Output Ripple & Noise (Max.) | ≤ 100 mVp-p (Residual Ripple) |
| Output Voltage Tolerance | ≤ ±1% (Static Deviation) |
| Load Regulation | ≤ ±1% (Dynamic Load Change 10% to 90%) |
| Hold-Up Time (at 115 VAC) | ≥ 12 ms (at 110 VAC Nominal Load) |
| Hold-Up Time (at 230 VAC) | ≥ 600 ms (at 230 VAC Nominal Load) |
| AC Input Voltage Range | 85 to 264 VAC (100 to 240 VAC Nominal, Single-Phase) |
| DC Input Voltage Range | 125 to 375 VDC (140 to 340 VDC Nominal; External DC Fuse Required) |
| Nominal Input Voltage | 100 to 240 VAC / 140 to 340 VDC |
| Input Frequency Range | 47 to 63 Hz (0 Hz for DC Operation) |
| Efficiency (at 115 VAC) | 87.5% typ. (at 110 VAC, Nominal Full Load) |
| Efficiency (at 230 VAC) | 88.5% typ. (at 230 VAC, Nominal Full Load) |
| AC Input Current (at 115 VAC) | ≤ 0.6 A |
| Inrush Current (Cold Start at 230 VAC) | ≤ 30 A (Active NTC Limiting) |
| Power Factor (PF at 230 VAC) | ≥ 0.5 |
| Power Factor Correction (PFC) | Passive PFC |
| No-Load Power Consumption | ≤ 0.6 W (9 W Max. Power Loss at 100 VAC / 12 VDC, 2.5 A) |
| Mounting Style | DIN Rail TS-35 (EN 60715) or Direct Chassis Screw Mount (Back / Side via Removable Front Panel) |
| Cooling Method | Free Air Convection |
| Package / Footprint Standard | Stepped Profile for Standard Distribution Boards (4 TE / 72 mm Width) |
| Overall Width (W) | 72 mm (2.835 in) |
| Overall Height (H) | 90 mm (3.543 in) |
| Overall Depth (D) | 56 mm (2.205 in) Total; 52.5 mm (2.067 in) from DIN Rail Upper Edge; 48 mm (1.890 in) without Cover |
| Net Weight | 63 g (0.063 kg / 2.22 oz / 0.139 lbs) |
| Termination / Connector Style | Pluggable Push-in CAGE CLAMP® (WAGO picoMAX® 5.0, 2092 Series, Tool-Free) |
| Input Terminal Pinout | Primary Input Connector: L, N, PE (Pluggable picoMAX® 5.0; Integrated T 3.15 A / 250 VAC Internal Fuse) |
| Output & Signal Terminal Pinout | Secondary Output Connector: DC+, DC- (Max. 30 m / 98.4 ft Secondary Cable Length) |
| Status Indicator | 1 × Green DC-OK LED (Uo Output Status) |
| Terminal Wire Gauge Range | 0.2 to 2.5 mm² / 24 to 12 AWG (Solid and Fine-Stranded Conductors; 9 to 10 mm / 0.35 to 0.39 in Strip Length) |
| Enclosure / Potting Material | Insulated Polyamide / Polycarbonate Stepped Housing (UL 94V-0) |
| Overload Protection (OLP) Threshold | 122% to 170% of Rated Output Current (1.22 to 1.7 × Io nom / 6.1 to 8.5 A) |
| Overload Protection (OLP) Mode | Constant Power Limiting in Overload Range; Hiccup Mode on Permanent Overload, Auto-Recovery |
| Overvoltage Protection (OVP) Threshold | ≤ 20 VDC (Secondary Fault Clamping; Primary Varistor Transient Suppression) |
| Short Circuit Protection (SCP) | Continuous Short-Circuit Protected & Open-Circuit Proof (Hiccup Mode with Automatic Recovery) |
| Reverse Polarity Protection | Yes (Secondary Reverse Feed Resistance ≤ 16 VDC) |
| Withstand Isolation Voltage (I/P to O/P) | 4.242 kVDC (SELV per EN 60335-1 / UL 60950-1; PELV per EN 60204) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2.12 kVDC (Protection Class I) |
| Earth Leakage Current | ≤ 0.25 mA (Discharge Current) |
| Operating Ambient Temperature Range | -25 °C to +70 °C (-13 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 230 VAC; +45 °C (+113 °F) at 90 VAC |
| High-Temperature Derating Rate | 2.3%/K above +50 °C (at 230 VAC); 3.0%/K above +45 °C (at 90 VAC) |
| Low-Line Input Derating | 2.0%/V below 100 VAC (85–100 VAC); 1.33%/V below 140 VDC (125–140 VDC) |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 20% to 90% RH (Non-Condensing) |
| Climatic Category (IEC 60068-1) | 3K3 per EN 60721 (Except Low Air Pressure); Overvoltage Category II, Pollution Degree 2 |
| Flammability Rating | UL 94V-0 |
| Ingress Protection (IP) | IP20 (per EN 60529) |
| Safety Approvals (UL / North America) | UL 508 Listed (File E255817), UL 60950-1 |
| Safety Approvals (IEC / EN / TÜV) | EN 62368-1, EN 60335-1 (Household/Building Appliances), EN 60204 (PELV) |
| Safety Approvals (Regional / Global) | CE Marked, EAC (TP TC 004/2011 CoC 03078, TP TC 020/2011 CoC 03081), GTIN 4055143804226, ETIM EC002540 |
| EMC Conducted & Radiated Emissions | EN 61204-3 Low-Voltage Switch Mode Power Supplies EMC Standard Compliant |
| EMC Immunity Standards | EN 61204-3 Industrial & Residential Electromagnetic Immunity Compliant |
| MTBF (Telcordia SR-332 / Bellcore) | > 500,000 Hours (Calculated per IEC 61709) |
| Environmental Compliance | RoHS Compliant (No Exemption), REACH Compliant |
Industrial Applications & Compatible Systems
The WAGO 787-1211 stepped-profile 12 VDC power supply is purpose-built for compact electrical sub-distribution boards and decentralized automation enclosures requiring tool-free termination:
- Building Automation & Sub-Distribution Panels: Fits directly behind standard domestic and commercial distribution board covers (52.5 mm rail depth) to power KNX/BACnet routers, HVAC actuators, and smart metering gateways.
- Access Control, Security & Household Systems: Certified to EN 60335-1 and SELV/PELV standards to safely energize 12 VDC door strikes, badge readers, intercom modules, and perimeter alarm sensors.
- Industrial Machine Control & Distributed I/O: Provides tightly regulated 12 VDC (adjustable 10–14 VDC) with ≥ 600 ms hold-up time at 230 VAC for WAGO I/O nodes, proximity sensors, and optical inspection lighting.
- Enclosed OEM Equipment & Retrofit Skids: Utilizes its removable front cover and integrated back/side screw-mount tabs (48 mm profile depth) to mount inside flat OEM machinery housings without DIN rails.
Installation, Thermal Management & MRO Guidelines
To ensure maximum service life and fault-free commissioning in industrial panels, observe these engineering practices:
- Thermal Derating & Low-Line Margins: Maintain free convection airflow and derate output load by 2.3%/K above +50 °C at 230 VAC (3.0%/K above +45 °C at 90 VAC) and by 2.0%/V when operating below 100 VAC.
- Upstream Breaker & DC Fuse Sizing: Protect the AC supply line using a 6 A or 10 A B-characteristic circuit breaker to accommodate the ≤ 30 A NTC cold-start inrush, and install an external DC-rated fuse when feeding 125–375 VDC.
- picoMAX® Wiring & Strain Relief: Strip 24–12 AWG conductors to 9–10 mm (0.35–0.39 in) for direct push-in termination, keep secondary 12 VDC cable runs under 30 m (98.4 ft), and add WAGO 2092-1601 gripping plates in high-vibration cabinets.