Description
TDK-Lambda DRB120-24-3-A1 (also known as DRB120243A1) is a compact, industrial three-phase DIN rail power supply from the DRB120-3 to DRB960-3 series, where the -24 suffix denotes a 24 VDC regulated output, -3 specifies three-phase AC input, and -A1 designates tool-free push-in wire terminals on an uncoated PCB. Engineered for 380 to 500 VAC nominal three-phase grids (342 to 575 VAC maximum) as well as 450 to 810 VDC high-voltage DC buses, it delivers 120 W continuous output (5 A at 24 VDC, adjustable from 22.5 to 29 VDC) with an extended 150% peak boost capacity of 180 W (7.5 A) for up to 600 seconds to energize high-capacitance and inductive loads. The switching topology achieves up to 91.3% efficiency at 400 VAC, maintains ultra-low ripple and noise of 10 mV (+25 to +70 °C), and supports single-phase dropped-phase operation at full 120 W output.
Comprehensive internal protection safeguards the unit and downstream automation hardware via constant-current and hiccup overcurrent protection (>142%), auto-recovery overvoltage protection (<32.7 V), and auto-recovery overtemperature protection, reinforced by 6,400 VAC input-to-output galvanic isolation. Convection-cooled inside a narrow 55 mm (2.17 in) aluminum chassis for TS-35/7.5 and TS-35/15 DIN rails, it operates at full 120 W load from -25 to +55 °C (-40 °C cold start-up) and up to +70 °C with linear derating. Standard control features include a DC Good relay contact, remote on/off inhibit input, and a front-panel DIP switch for parallel droop current sharing, backed by IEC/EN/UL/CSA 61010-1, 61010-2-201, and 62368-1 safety certifications.
Key Features
- Wide Three-Phase & High-Voltage DC Input: Operates across 380–500 VAC nominal three-phase lines (342–575 VAC max, 620 VAC 5 s surge) and 450–810 VDC buses, sustaining full 120 W output even during a dropped phase.
- Extended 150% Peak Boost Power: Delivers 24 VDC at 5 A (120 W) continuously, adjustable from 22.5 to 29 VDC, plus 7.5 A (180 W) peak boost for up to 600 seconds for heavy inductive/capacitive loads.
- High Efficiency & Low Standby Draw: Achieves 91.3% full-load efficiency at 400 VAC (91.2% at 500 VAC) with low 1.7 W to 2.1 W no-load power consumption and 25 A / 30 A low cold-start inrush.
- Push-In Terminals & Control Integration: Features tool-free push-in spring terminals (-A1 option) for rapid robotic or panel wiring, alongside a DC Good relay contact, remote on/off, and parallel droop DIP switch.
- Reinforced 6.4 kV Isolation & Protections: Provides 6,400 VAC input-to-output withstand isolation, >142% constant-current/hiccup overload protection, <32.7 V auto-recovery OVP, and auto-recovery thermal shutdown.
- Compact 55 mm Aluminum DIN Chassis: Measures just 55 × 129 × 138.2 mm (2.17 × 5.08 × 5.44 in) with convection cooling from -25 to +55 °C full load (-40 °C start-up) and 1,100,000-hour Telcordia MTBF.
- Global Industrial Safety & Class B EMC: Certified to IEC/EN/UL/CSA 61010-1, 61010-2-201, 62368-1, CE, and UKCA, while meeting EN 55011 / CISPR 11 Class B emissions and IEC 61000-4 industrial immunity.
Technical Specifications
| Manufacturer | TDK-Lambda |
|---|---|
| Manufacturer Part Number (MPN) | DRB120-24-3-A1 |
| Alternate Part Number | DRB120243A1 |
| Product Series | DRB120-3 – DRB960-3 Series |
| Product Category | Redundancy Modules |
| Component Type | Three-Phase AC-DC / High-Voltage DC-DC DIN Rail Power Supply |
| Option Code Suffix | -A1 (Push-In Wire Terminals, Uncoated PCB) |
| Nominal Output Voltage | 24 VDC |
| Output Voltage Adjustment Range | 22.5 to 29 VDC (via Front Potentiometer) |
| Output Voltage Tolerance | ±3% Maximum |
| Rated Continuous Output Current | 5 A |
| Maximum Peak / Boost Output Current | 7.5 A (150% Boost for up to 600 Seconds) |
| Rated Continuous Output Power | 120 W |
| Maximum Peak / Boost Output Power | 180 W (150% Boost for up to 600 Seconds) |
| Dropped-Phase Output Power | 120 W (Sustains Full Rated Power on Two Phases) |
| Minimum Load Requirement | 0 A (No Minimum Load Required) |
| Ripple & Noise (+25 to +70 °C Ambient) | 10 mVp-p |
| Ripple & Noise (-25 to < +25 °C Ambient) | 120 mVp-p |
| Line Regulation | 0.06% |
| Load Regulation (Single / Non-Parallel Mode) | 0.2% |
| Load Regulation (Parallel Droop Mode) | 2.9% |
| Maximum Capacitive Load | 10,000 µF |
| Hold-Up Time (at 400 VAC) | 20 ms Minimum |
| Hold-Up Time (at 500 VAC) | 40 ms Minimum |
| Nominal AC Input Voltage Range | 3-Phase 380 to 500 VAC |
| Maximum AC Input Voltage Range | 3-Phase 342 to 575 VAC (Safety Certified for 380–500 VAC) |
| Input Surge Voltage Withstand | 620 VAC for 5 Seconds |
| Maximum DC Input Voltage Range | 450 to 810 VDC (External DC Fuse Required) |
| Input Line Frequency | 47 to 63 Hz |
| Efficiency (at 400 VAC, 100% Load) | 91.3% |
| Efficiency (at 500 VAC, 100% Load) | 91.2% |
| Average Active Efficiency (at 400 VAC, EU 2019/1782) | 89.4% (25%, 50%, 75%, 100% Load Average) |
| Average Active Efficiency (at 500 VAC, EU 2019/1782) | 88.5% (25%, 50%, 75%, 100% Load Average) |
| AC Input Current (Per Phase Max) | 0.5 A |
| DC Input Current (Max) | 0.5 A |
| Inrush Current (Cold Start at 400 VAC) | 25 A Typical |
| Inrush Current (Cold Start at 500 VAC) | 30 A Typical |
| Power Factor (Typical at 400 / 500 VAC) | 0.5 |
| No-Load Standby Power Consumption (at 400 VAC) | 1.7 W Maximum |
| No-Load Standby Power Consumption (at 500 VAC) | 2.1 W Maximum |
| Output Converter Switching Frequency | 50 to 135 kHz (Variable with Input Line & Output Load) |
| Overcurrent / Overload Protection (OCP) Threshold | >142% of Rated Current |
| Overcurrent / Overload Protection (OCP) Mode | Constant Current & Hiccup Mode |
| Overvoltage Protection (OVP) Threshold | <32.7 VDC |
| Overvoltage Protection (OVP) Mode | Auto-Recovery |
| Overtemperature Protection (OTP) Mode | Yes, Auto-Recovery |
| Withstand Isolation Voltage (Input to Output) | 6,400 VAC (1 Minute) |
| Withstand Isolation Voltage (Input to GND / PE) | 2,210 VAC (1 Minute) |
| Withstand Isolation Voltage (Output to GND & Signals) | 1,390 VAC (1 Minute) |
| Earth Leakage Current (at 575 VAC, 60 Hz) | <1 mA |
| Touch Current (at 575 VAC, 60 Hz) | <50 µA |
| Operating Ambient Temperature Range | -25 °C to +70 °C (-13 °F to +158 °F) with Derating |
| Cold Start-Up Temperature Capability | -40 °C (-40 °F) |
| Full-Load Operating Temperature Limit | +55 °C (+131 °F) |
| High-Temperature Derating Rate | 2 W/°C Linear Derating Above +55 °C up to +70 °C |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating & Storage Relative Humidity | 95% RH Maximum (Non-Condensing) |
| Operating Altitude | 3,000 m Nominal (6,000 m Maximum without UL Certification) |
| Electrolytic Capacitor Service Life | 10 Years Typical (Conservatively Rated) |
| MTBF (Telcordia SR-332 Issue 4) | 1,100,000 Hours (at +25 °C Ambient, Full Load) |
| Vibration Resistance (Non-Operating on DIN Rail) | IEC 60068-2-6: 2g, 10 to 500 Hz, 1 Hour per Axis (X, Y, Z) |
| Shock Resistance (Non-Operating on DIN Rail) | IEC 60068-2-27: 30g / 11 ms ±5 ms, 3 Shocks per Axis |
| Safety Certifications & Agency Approvals | IEC/EN/UL/CSA 61010-1, 61010-2-201, 62368-1, CE Mark, UKCA Mark |
| Additional Standards Compliance (Designed to Meet) | IEC 60950-1, EN 60204-1, IEC/EN 62477-1, 61204-7, 61558-2-16, 60068-2-60 (Mixed Gas), 60068-2-11 (Salt Mist) |
| Conducted & Radiated EMI Emissions | EN 55011 Class B, CISPR 11 Class B |
| Harmonic Current Emissions | EN 61000-3-2 Class A |
| ESD Immunity (EN 61000-4-2) | 4 kV Contact Discharge, 8 kV Air Discharge (Criterion A) |
| Radiated RF Susceptibility (EN 61000-4-3) | 10 V/m (80 MHz–1 GHz), 3 V/m (1.4–2 GHz), 1 V/m (2–2.7 GHz) (Criterion A) |
| Electrical Fast Transient / Burst (EN 61000-4-4) | Input 4 kV (5 kHz), Output 2 kV (5 kHz), Signal Contact 2 kV (5 kHz) (Criterion A) |
| Surge Immunity (EN 61000-4-5) | Input 2 kV L-L / 4 kV L-PE; Output 0.5 kV L-L / 1 kV L-PE (Criterion A) |
| Conducted RF Susceptibility (EN 61000-4-6) | 10 V (150 kHz to 80 MHz) (Criterion A) |
| Power Frequency Magnetic Field (EN 61000-4-8) | 30 A/m at 50 Hz, 60 s per Axis X, Y, Z (Criterion A) |
| Voltage Dips & Interruptions (EN 61000-4-11 / -4-34) | 70% for 500 ms (A), 40% for 200 ms (A), 0% for 20 ms (A), 0% for 5,000 ms (C) at 400 VAC 50 Hz |
| DC Good Status Output | Closed Relay Contact When Output Voltage >95% of Nominal |
| Remote On/Off Control | Closed Contact or <4 V Enables Output |
| Parallel Operation / Current Sharing | Front-Panel DIP Switch Enables Parallel Droop Mode Current Sharing |
| Status LED Indicator | Green LED Indicates DC OK |
| Termination Style | Push-In Spring Clamp Terminals (Input, Output & Control Signals) |
| Input Terminal Pinout | 4-Position Push-In Terminal Block: L1, L2, L3, PE (Earth) |
| Output & Signal Terminal Pinout | Push-In Terminals: +V, +V, -V, -V, DC OK Relay (2 Pins), Inhibit +/- |
| Cooling Method | Natural Convection Cooling |
| Mounting Style | DIN Rail Mount (TS-35/7.5 or TS-35/15) |
| Enclosure Material | Aluminum |
| Overall Width (W) | 55 mm (2.17 in) |
| Overall Height (H) | 129 mm (5.08 in) |
| Overall Depth (D, Push-In -A1 Model) | 138.2 mm (5.44 in) |
| Overall Dimensions (W × H × D) | 55 × 129 × 138.2 mm (2.17 × 5.08 × 5.44 in) |
| Net Weight | 660 g (1.46 lbs / 23.28 oz) |
| Manufacturer Warranty | 3 Years |
Industrial Applications & Compatible Systems
TDK-Lambda DRB120-24-3-A1 is engineered for three-phase industrial control cabinets and automated machinery requiring high-reliability 24 VDC auxiliary power:
- Industrial Process Control & Factory Automation: Powers 24 VDC PLCs, distributed remote I/O islands, safety relays, and HMI panels directly from 400 VAC or 480 VAC three-phase distribution buses without a step-down control transformer.
- Automated Panel Building & Robotic Wiring Lines: Tool-free push-in spring terminals (-A1 option) accelerate harness termination and resist loosening under continuous machine vibration.
- Solenoid Valve Manifolds, Contactors & Inductive Actuators: The 150% peak power boost (180 W / 7.5 A for 600 seconds) absorbs high inrush currents from pneumatic valve banks and DC motor brakes without voltage sag.
- Redundant & High-Availability 24 VDC Control Systems: Front-panel parallel droop DIP switch, DC Good relay, and remote inhibit integrate directly with TDK-Lambda DRM40 redundancy modules or DBM20 buffer modules.
Installation, Thermal Management & MRO Guidelines
Installation & Engineering Guidelines: Mount the unit vertically on standard TS-35/7.5 or TS-35/15 DIN rail with unobstructed top and bottom airflow clearance for natural convection cooling, and derate output load linearly at 2 W/°C when ambient cabinet temperatures exceed +55 °C (up to +70 °C maximum). Although the power supply tolerates 342 to 575 VAC input transients, ensure continuous steady-state operation remains within the UL/IEC safety-certified 380 to 500 VAC three-phase window; when supplying 450 to 810 VDC input, install an external UL-listed DC-rated fuse upstream. For N+1 redundant or parallel load-sharing configurations, set the front-panel DIP switch to parallel droop mode and adjust individual output voltages within 50 mV before connecting loads.